Open Access. Powered by Scholars. Published by Universities.®

Biomedical Engineering and Bioengineering Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 30 of 51

Full-Text Articles in Biomedical Engineering and Bioengineering

Subject-Specific Human Knee Fea Models For Transtibial Amputees Vs Control Tibial Cartilage Pressure In Gait, Cycling And Elliptical Training, Ali Yazdkhasti Aug 2023

Subject-Specific Human Knee Fea Models For Transtibial Amputees Vs Control Tibial Cartilage Pressure In Gait, Cycling And Elliptical Training, Ali Yazdkhasti

Master's Theses

Millions of individuals around the globe are impacted by osteoarthritis, which is the prevailing type of arthritis. This condition arises as a result of gradual deterioration of the protective cartilage that safeguards the ends of the bones. This is especially true of transtibial amputees, who have a significantly higher incidence of osteoarthritis of the knee in their intact limb than non-amputees. Engaging in regular physical activity, managing weight effectively, and undergoing specific treatments can potentially slow down the advancement of the disease and enhance pain relief and joint function. Nevertheless, the relationship between the type of exercise and its impact …


Bespoke Bicycle Enclosure, Thomas Link, Kyle Mcafee, Marc Monier, Hunter Walden Jun 2023

Bespoke Bicycle Enclosure, Thomas Link, Kyle Mcafee, Marc Monier, Hunter Walden

Mechanical Engineering

Brian Higgins is an American veteran with retinitis pigmentosa who relies on cycling for transportation. The motivation for this project is to design and manufacture a refined prototype bicycle attachment to support him while biking in the rain and cold. The attachment will serve to enclose him for optimal protection from inclement weather, while maintaining sufficient mobility for daily cycling. Mr. Higgins’ bicycle is equipped with an attached sensor system which assists his visual impairment by using an ultrasonic sensor. Therefore, the attachment cannot adversely affect the function of the sensor system. The project timeline is set at approximately 7 …


Insole Fall Prevention Device, Nick M. Hughes, Andrew M. Slaboda May 2022

Insole Fall Prevention Device, Nick M. Hughes, Andrew M. Slaboda

Biomedical Engineering

Falls among the aging population occur every single day, with 1 in every 5 resulting in some injury and 300,000 hospitalized every year with a hip fracture [1]. The most popular and effective way to mitigate these falls is through physical therapist intervention. However, with the increased popularity in telerehab, many patients at risk for falls cannot accurately convey their gait tendencies to their physical therapists from the comfort of their home or while not in direct contact with the PT. A device like an insole, implanted with force sensors, which measures different parts of a patient’s foot, could convey …


Acl Risk Data Comparison And Turnout Analysis Of Female Dancers Trained In Ballet And Female Traditional Jumping Sport Athletes, Samantha A. Campbell Mar 2022

Acl Risk Data Comparison And Turnout Analysis Of Female Dancers Trained In Ballet And Female Traditional Jumping Sport Athletes, Samantha A. Campbell

Master's Theses

INTRODUCTION: An increase in participation in females sports has created an increase of female athletes at risk for injuring their Anterior Cruciate Ligament(ACL)[12,21,29,44]. Traditional jumping sports have the highest rate of non contact ACL injuries, due to the use of movements of cutting, pivoting and landing on one foot[5,8,32,33,38]. ACL injuries can also be attributed to neuromuscular deficits such as the ‘Ligament Dominance Theory’, ‘Quadricep Dominance Theory’, ‘Trunk Dominance Theory’ and the ‘Leg Dominance Theory’[24,33]. The neuromuscular deficits are muscle strength, power or activation patterns that can cause an individual to have an increased risk of ACL injury[33]. Female traditional …


Pickleball Paddle For Minimizing Elbow/Shoulder Joint Forces, Kaley Sapper, Nick Rodgers, Claire Steines Mar 2022

Pickleball Paddle For Minimizing Elbow/Shoulder Joint Forces, Kaley Sapper, Nick Rodgers, Claire Steines

Biomedical Engineering

The goal of this project was to design a pickleball paddle to prevent overuse injuries. This was accomplished through a design that minimizes joint forces experienced by the player during backhand strokes.


Bone And Cartilage Compression Simulator, Karoline M. Wucherer, Benjamin A. Parmentier, Thomasina E. Hinkle Mar 2022

Bone And Cartilage Compression Simulator, Karoline M. Wucherer, Benjamin A. Parmentier, Thomasina E. Hinkle

Biomedical Engineering

A device was developed that delivers mechanical loads to bone and soft tissue samples under physiological conditions to aid in the research of tissue engineering bone and cartilage. To begin the design process, a Network Diagram and Gantt Chart were produced to create a general timeline for the project to follow. This allowed us to measure our progress and determine what effects (if any) delays could have on our project.


Youth Pitching Kinematics: Associations With Body Overweight Parameters, Christina K. Fong Mar 2022

Youth Pitching Kinematics: Associations With Body Overweight Parameters, Christina K. Fong

Master's Theses

The objective of this study was to investigate associations between injury-related kinematic parameters and overweight measures for youth baseball pitchers. The injury-related kinematic parameters considered were measurements 1) at foot contact: stride length, front foot position, shoulder external rotation, shoulder abduction, and elbow flexion; 2) between FC and ball release: peak knee extension; and 3) at BR: shoulder abduction. Data from three separate collection sites examined pitching mechanics of 18 10- to 11-year-old pitchers, 11 14- to 16-year-old pitchers, and 104 16- to 18-year-old pitchers Linear regression analyses were performed to determine significant correlations between kinematic parameters and body mass …


Subclinical Atherosclerosis Quantified Through Cumulative Shear Measurement, Margaret Lynne Papka Aug 2021

Subclinical Atherosclerosis Quantified Through Cumulative Shear Measurement, Margaret Lynne Papka

Master's Theses

With the high mortality rate of cardiovascular disease, it is important to study the early signs. The early detection of cardiovascular disease can lead to saved lives. Currently the most prevalent detection methods are the Framingham Risk Score and the carotid intima media thickness, both of which are insufficient. The necessary tool for early detection requires a uniform quantification system. The stimulus leading to endothelial dysfunction, the most significant predictor of a major adverse cardiovascular event (MACE)—and subsequently subclinical atherosclerosis—is reduced shear stress. Increased surface relative roughness affects the flow profile transition from laminar to turbulent resulting in reduced shear …


Smartphone-Tape Method For Calculating Body Segment Inertial Parameters For Analysis Of Pitching Arm Kinetics, Jay Sterner Jun 2020

Smartphone-Tape Method For Calculating Body Segment Inertial Parameters For Analysis Of Pitching Arm Kinetics, Jay Sterner

Master's Theses

The objectives of this study were to (1) develop a non-invasive method (referred to as Smart Photo-Tape) to calculate participant-specific upper arm, forearm, and hand segment inertial properties (SIPs) (e.g. mass, center of mass, and radii of gyration) and (2) use those Smart Photo-Tape properties in inverse dynamics (ID) analyses to calculate injury-related pitching arm kinetics. Five 20- to 23- year-old baseball pitchers were photographed holding a baseball and analyzed using the Smart Photo-Tape method to obtain 3-D inertial properties for their upper arm, forearm, and hand. The upper arm and forearm segments were modelled as stacked elliptic cylinders and …


Design Of Prototype Prosthesis For A Canine With A Right Front Limb Deformity As An Alternate Approach To Stabilize Gait And Withstand Gait Forces, Tayler R. Kastlunger Jun 2020

Design Of Prototype Prosthesis For A Canine With A Right Front Limb Deformity As An Alternate Approach To Stabilize Gait And Withstand Gait Forces, Tayler R. Kastlunger

Master's Theses

Congenital and developmental limb deformities in canines are rare and can occur as a genetic disorder or be caused by extrinsic factors. Without surgery to correct the deformity, conservative management can be implemented to manage exercise and restrict high-intensity activity of the canine. However, any alteration to the normal gait and locomotive biomechanics of a canine can have significant long-term effects on the musculoskeletal health and quality of life of the canine. To improve quality of life and provide an alternative and more cost-effective approach to surgery, a custom prosthetic was designed and developed for a canine born with a …


On-Body Pressure For Subcutaneous Infusion Of Drug, Hannah Cole, Kayla Meacham, Eleanor Moran, Kaylee Voss Mar 2020

On-Body Pressure For Subcutaneous Infusion Of Drug, Hannah Cole, Kayla Meacham, Eleanor Moran, Kaylee Voss

Biomedical Engineering

No abstract provided.


Solostand, Hau Nhat Doan, Sydney Gray, Celina Dioso Mar 2020

Solostand, Hau Nhat Doan, Sydney Gray, Celina Dioso

Biomedical Engineering

The purpose of this scope of work is to highlight the progress and development of SoloStand sponsored by Derek Herrera, chief technical officer and founder of SpinalSingularity. SoloStand is an attachment to a wheelchair that will benefit paraplegics that use wheelchairs. A portable and customizable attachment to a wheelchair will allow the user to do everyday tasks without transferring into a separate standing wheelchair and travel more easily. This document outlines everything that has been done in fulfillment of our senior project requirements.


Cumulative Shear In Vitro Model, Jared Olson, Alex Deppe, Braden Andrews Mar 2020

Cumulative Shear In Vitro Model, Jared Olson, Alex Deppe, Braden Andrews

Biomedical Engineering

The purpose of our project is to find a reliable method of Subclinical Atherosclerosis detection by measuring the pressure drop across an artery. This model is intended to display how a pressure change correlates with arterial shear rate, and how a decrease in shear rate is ultimately related to atherosclerosis wherein early detection could prove life saving for millions of patients worldwide.


Subject-Specific Finite Element Models Of The Human Knee For Transtibial Amputees To Analyze Tibial Cartilage Pressure For Gait, Cycling, And Elliptical Training, Jonathon Stearns Mar 2020

Subject-Specific Finite Element Models Of The Human Knee For Transtibial Amputees To Analyze Tibial Cartilage Pressure For Gait, Cycling, And Elliptical Training, Jonathon Stearns

Master's Theses

It is estimated that approximately 10-12% of the adult population suffers from osteoarthritis (OA), with long reaching burdens personally and socioeconomically. OA also causes mild discomfort to severe pain in those suffering from the disease. The incidence rate of OA for individuals with transtibial amputations is much than average in the tibiofemoral joint (TF). It is well understood that abnormal articular cartilage stress, whether that be magnitude or location, increases the risk of developing OA. Finite element (FE) simulations can predict stress in the TF joint, many studies throughout the years have validated the technology used for this purpose. This …


Skier's Edge: Biomechanical Analysis, Benjamin T. Johannes Mar 2020

Skier's Edge: Biomechanical Analysis, Benjamin T. Johannes

Master's Theses

ABSTRACT

Skier’s Edge: Biomechanical Analysis

Benjamin T. Johannes

The Skier’s Edge trainer can be used by novice or expert skiers. Testing was performed to analyze if the use of the Skier’s Edge could reduce in shear forces of the valgus moment on the knee joint and anterior cruciate ligament (ACL) due to lesser fatigue of muscle and a higher hamstring to quadricep (H/Q) ratio activity. This leads to a reduction of improper form and an increase in balance. Experiments performed observed the change in muscle activity with the use of the Skier’s Edge over time when compared to other forms …


Transmission Probability Of Embolic Debris Through The Aortic Arch And Daughter Vessels During A Transcatheter Aortic Valve Replacement Procedure, Jessica Lena Wirth Jun 2019

Transmission Probability Of Embolic Debris Through The Aortic Arch And Daughter Vessels During A Transcatheter Aortic Valve Replacement Procedure, Jessica Lena Wirth

Master's Theses

Cerebral ischemia leading to an ischemic stroke is a possible complication of a transcatheter aortic valve replacement (TAVR) procedure. This is because embolic debris can become dislodged and travel through the aortic arch, where they either continue to the descending aorta and join the systemic circulation or travel into the cerebral vasculature through the three daughter vessels that branch off the top of the aortic arch. These three vessels are the brachiocephalic artery, the left subclavian artery, and the left common carotid artery. These three vessels lead either directly or indirectly to the cerebral vasculature, where the diameter of vessels …


Sand Foot: A Prosthesis For Walking On Sand, Samantha A. Galicinao, John Dewing, Daniel Dugan Dotson, Christopher Urasaki Jun 2019

Sand Foot: A Prosthesis For Walking On Sand, Samantha A. Galicinao, John Dewing, Daniel Dugan Dotson, Christopher Urasaki

Biomedical Engineering

This critical design report describes the product development of a prosthesis for use on sand. Quality of Life Plus (QL+), a national non-profit organization aimed to develop prostheses for veterans and people with disabilities, introduced this project and its accompanying challenger, Sgt. Brady, to Cal Poly’s Interdisciplinary Senior Project class in September 2018. After consulting with Sgt. Brady and QL+ and performing extensive research, the Sand Foot team defined customer requirements and engineering specifications to meet these requirements. Comfortability, durability, and sandproof were key customer requirements. Several conceptual models were brainstormed and a final design was selected based on the …


Fluid Delivery System For A Cell Culture On A Microfluidic Chip, Austin J. Roeder, Colleen A. Richards, Emily A. Matteson Mar 2019

Fluid Delivery System For A Cell Culture On A Microfluidic Chip, Austin J. Roeder, Colleen A. Richards, Emily A. Matteson

Biomedical Engineering

This project report provides a description of the progress made in the development of a fluid delivery system for a microfluidic cell culture on a chip. The system is intended to be used in a humidified incubator in a university laboratory and the fluid delivery system is required to exist and operate within that incubator for extended periods of time. Therefore, the system will be gravity-driven and contain no electronic components. The key specification of the system is to provide fluid flow at a constant velocity.

After manufacturing and testing the device, all specifications were met except for the fluid …


Hip And Knee Biomechanics For Transtibial Amputees In Gait, Cycling, And Elliptical Training, Greg Orekhov Dec 2018

Hip And Knee Biomechanics For Transtibial Amputees In Gait, Cycling, And Elliptical Training, Greg Orekhov

Master's Theses

Transtibial amputees are at increased risk of contralateral hip and knee joint osteoarthritis, likely due to abnormal biomechanics. Biomechanical challenges exist for transtibial amputees in gait and cycling; particularly, asymmetry in ground/pedal reaction forces and joint kinetics is well documented and state-of-the-art passive and powered prostheses do not fully restore natural biomechanics. Elliptical training has not been studied as a potential exercise for rehabilitation, nor have any studies been published that compare joint kinematics and kinetics and ground/pedal reaction forces for the same group of transtibial amputees in gait, cycling, and elliptical training. The hypothesis was that hip and knee …


Microfluidic Electrical Impedance Spectroscopy, John J. Foley Sep 2018

Microfluidic Electrical Impedance Spectroscopy, John J. Foley

Master's Theses

The goal of this study is to design and manufacture a microfluidic device capable of measuring changes in impedance valuesof microfluidic cell cultures. Tocharacterize this, an interdigitated array of electrodes was patterned over glass, where it was then bonded to a series of fluidic networks created in PDMS via soft lithography. The device measured ethanol impedance initially to show that values remain consistent over time. Impedance values of water and 1% wt. saltwater were compared to show that the device is able to detect changes in impedance, with up to a 60% reduction in electrical impedance in saltwater. Cells were …


Inverse Dynamic Analysis Of Acl Reconstructed Knee Joint Biomechanics During Gait And Cycling Using Opensim, Megan V. Pottinger Aug 2018

Inverse Dynamic Analysis Of Acl Reconstructed Knee Joint Biomechanics During Gait And Cycling Using Opensim, Megan V. Pottinger

Master's Theses

ACL (anterior cruciate ligament) injuries of the knee joint alter biomechanics and may cause abnormal loading conditions that place patients at a higher risk of developing osteoarthritis (OA). There are multiple types of ACL reconstruction (ACLR), but all types aim to restore anterior tibial translation and internal tibial rotation following surgery. Analyzing knee joint contact loads provide insight into the loading conditions following ACLR that may contribute to the long-term development of OA. Ten ACLR subjects, who underwent the same reconstruction, performed gait and cycling experiments while kinematic and kinetic data were collected. Inverse dynamic analyses were performed on processed …


Characterization Of Arterial Flow For Junctional Bleeding Control, Nick Bosio Jun 2018

Characterization Of Arterial Flow For Junctional Bleeding Control, Nick Bosio

Master's Theses

This study investigated reducing volumetric flowrate under steady flow conditions by varying lengths of compression with constant cross-sectional area and varying cross-sectional area reduction with constant length in order to better understand how to control junctional hemorrhaging. The hypotheses of this study were that length reduction will have little effect on volumetric flowrate and that cross-sectional area reduction would need to be approximately 80 percent in order to obtain bleeding control. The study found that length reduction has little effect on changing the flowrate. However, in order to obtain at least 80 percent reduction in flow, the area needs to …


Detection Method Of Subclinical Atherosclerosis Of The Carotid Artery With A Hemodynamics Modeling Approach, Marisa Peressini Jun 2018

Detection Method Of Subclinical Atherosclerosis Of The Carotid Artery With A Hemodynamics Modeling Approach, Marisa Peressini

Master's Theses

Subclinical atherosclerosis is an important area of research to evaluate stroke risk and predict localization of plaque. The current methods for detecting atherosclerosis risk are insufficient because it is based on The Framingham Risk Score and carotid intima media thickness, therefore an engineering detection model based on quantifiable data is needed. Laminar and turbulent flow, dictated by Reynolds number and relative roughness, was modeled through the carotid artery bifurcation to compare shear stress and shear rate. Computer-aided design and fluid flow software were used to model hemodynamics through the carotid artery. Data from the model was derived from governing equations …


Usa Boccia Ball Ramp For Athletes With Quadriplegia, Alissa A. Koukourikos, Matthew Lee, Nathan Bernards Dec 2017

Usa Boccia Ball Ramp For Athletes With Quadriplegia, Alissa A. Koukourikos, Matthew Lee, Nathan Bernards

Mechanical Engineering

In this report, the design process in creating an assistive device for Boccia Classification 3 (BC3) players is outlined. The initial research steps, including research into the rules of the game, capabilities of the players, and existing products is documented to show where ideas for the product stemmed from. This transitions into requirements that the sponsor requested, and preliminary designs and ideas for the product. Finally, this report explains the details of the final design, which has been analyzed for safety, ease of use, and ability to function under different conditions. The processes of manufacturing and testing will also be …


Fluid Flow Characterization And In Silico Validation In A Rapid Prototyped Abdominal Aortic Aneurysm Model, Dean Thomas Wampler Mar 2017

Fluid Flow Characterization And In Silico Validation In A Rapid Prototyped Abdominal Aortic Aneurysm Model, Dean Thomas Wampler

Master's Theses

Aortic aneurysms are the 14th leading cause of death in the United States. Annually, abdominal aortic aneurysm (AAA) ruptures are responsible for 4500 deaths. There are another 45,000 repair procedures performed to prevent rupture, and of these approximately 1400 lead to deaths. With proper detection, the aneurysm may be treated using endovascular aneurysm repair (EVAR). Understanding how the flow of the blood within the artery is affected by the aneurysm is important in determining the growth of the aneurysm, as well as how to properly treat the aneurysm. The goal of this project was to develop a physical construct …


Functional 3-D Cellulose And Nitrocellulose Paper-Based, Microfluidic Device Utilizing Elisa Technology For The Detection/Distinction Between Hemorrhagic And Ischemic Strokes, Alicia Leanne Holler Dec 2016

Functional 3-D Cellulose And Nitrocellulose Paper-Based, Microfluidic Device Utilizing Elisa Technology For The Detection/Distinction Between Hemorrhagic And Ischemic Strokes, Alicia Leanne Holler

Master's Theses

The purpose of this thesis project is to demonstrate and evaluate an enzyme-linked immunosorbent assay (ELISA) on a paper microfluidic device platform. The integration of ELISA technology onto paper microfluidic chips allows for a quantitative detection of stroke biomarkers, such as glial fibrillary acidic protein (GFAP). Dye experiments were performed to confirm fluid connectivity throughout the 3D chips. Several chip and housing designs were fabricated to determine an optimal design for the microfluidic device. Once this design was finalized, development time testing was performed. The results confirmed that the paper microfluidic device could successfully route fluid throughout its channels at …


Fluid Flow Characterization And In Silico Validation In A Rapid Prototyped Aortic Arch Model, Alexandra Mariel Knauer Aug 2016

Fluid Flow Characterization And In Silico Validation In A Rapid Prototyped Aortic Arch Model, Alexandra Mariel Knauer

Master's Theses

Transcatheter aortic heart valve replacement (TAVR) is a procedure to replace a failing aortic valve and is becoming the new standard of care for patients that are not candidates for open-heart surgery [2]. However, this minimally invasive technique has shown to cause ischemic brain lesions, or “silent infarcts”, in 90% of TAVR patients, which can increase the patient’s risk for stroke by two to four times in future years [3]. Claret Medical Inc., a medical device company, has developed a cerebral protection system that filters and captures embolic debris released during endovascular procedures, such as TAVR. This thesis utilized CT …


Prosthetic Leg Kit For Deployment In Developing Countries, Brian Murphy, Dominique Porcincula, Derek Morgan, Kendall Ruggles, Christian Aguayo Jun 2016

Prosthetic Leg Kit For Deployment In Developing Countries, Brian Murphy, Dominique Porcincula, Derek Morgan, Kendall Ruggles, Christian Aguayo

Biomedical Engineering

The World Health Organization estimates that over 30 million people require some sort of prosthetic technology. However, traditional prosthetic fitting practices take a lot of time and cost a lot of money, making them inaccessible to millions of people around the world. StandUP Worldwide is an interdisciplinary project team devoted to creating low-cost prosthetic technologies for use around the world, especially in resource poor areas. They are currently developing a low cost, below-the-knee prosthetic kit that can be easily deployed in a resource-poor area. The following presents their solution for a below-the-knee prosthetic socket, foot, and leg.


The Effects Of Obesity On Resultant Knee Joint Loads For Gait And Cycling, Juan Gutierrez-Franco Jun 2016

The Effects Of Obesity On Resultant Knee Joint Loads For Gait And Cycling, Juan Gutierrez-Franco

Master's Theses

Osteoarthritis (OA) is a degenerative disease of cartilage and bone tissue and the most common form of arthritis, accounting for US$ 10.5 billion in hospital charges in 2006. Obesity (OB) has been linked to increased risk of developing knee OA due to increased knee joint loads and varus-valgus misalignment. Walking is recommended as a weight-loss activity but it may increase risk of knee OA as OB gait increases knee loads. Cycling has been proposed as an alternative weight-loss measure, however, lack of studies comparing normal weight (NW) and OB subjects in cycling and gait hinder identification of exercises that may …


Fluid Flow Characterization In Rapid Prototyped Common Iliac Artery Aneurysm Molds, Daniel Cole Greinke Mar 2016

Fluid Flow Characterization In Rapid Prototyped Common Iliac Artery Aneurysm Molds, Daniel Cole Greinke

Master's Theses

The goal of this project was to determine whether i) fused deposition modeling could be employed to manufacture molds for vascular constructs, ii) whether vascular constructs could be created from these molds, and iii) to verify practical equivalence between observed fluid velocities. Dye tracking was to be employed to characterize fluid velocity profiles through the in vitro vascular constructs, including a half-vessel model and a full vessel model of an iliac artery aneurysm. A PDMS half-vessel construct was manufactured, and the movement of dye through the construct was tracked by a cellphone camera. Thresholds were applied to each video in …