Open Access. Powered by Scholars. Published by Universities.®

Biomedical Engineering and Bioengineering Commons

Open Access. Powered by Scholars. Published by Universities.®

Biomechanical Engineering

2017

Institution
Keyword
Publication
Publication Type

Articles 1 - 18 of 18

Full-Text Articles in Biomedical Engineering and Bioengineering

Usa Boccia Ball Ramp For Athletes With Quadriplegia, Alissa A. Koukourikos, Matthew Lee, Nathan Bernards Dec 2017

Usa Boccia Ball Ramp For Athletes With Quadriplegia, Alissa A. Koukourikos, Matthew Lee, Nathan Bernards

Mechanical Engineering

In this report, the design process in creating an assistive device for Boccia Classification 3 (BC3) players is outlined. The initial research steps, including research into the rules of the game, capabilities of the players, and existing products is documented to show where ideas for the product stemmed from. This transitions into requirements that the sponsor requested, and preliminary designs and ideas for the product. Finally, this report explains the details of the final design, which has been analyzed for safety, ease of use, and ability to function under different conditions. The processes of manufacturing and testing will also be …


Material Properties Design Using Simulations And Experiments For Powder Injection Molding Of Lead Zirconate Titanate (Pzt)., Bhushan Pramod Bandiwadekar Dec 2017

Material Properties Design Using Simulations And Experiments For Powder Injection Molding Of Lead Zirconate Titanate (Pzt)., Bhushan Pramod Bandiwadekar

Electronic Theses and Dissertations

Powder injection molding (PIM) process simulations can be performed to minimize the number of injection molding experiments by estimating material properties necessary for PIM simulations. In current work, lead zirconate titanate (PZT) powder-polymer binder feedstock was compounded for 45 vol. % and 52 vol. % solids loading. PIM experiments on designed micro-pillar array geometry were performed using 52 vol. % PZT. Using PIM experiments results as basis, PIM simulations were performed on designed micro-pillar array geometries to understand the effectiveness of PIM simulations with the use of estimated feedstock properties in predicting molding behavior that have micro-features. Additionally, PIM simulations …


Effects Of Malformed Or Absent Valves To Lymphatic Fluid Transport And Lymphedema In Vivo In Mice, Akshay S. Pujari Oct 2017

Effects Of Malformed Or Absent Valves To Lymphatic Fluid Transport And Lymphedema In Vivo In Mice, Akshay S. Pujari

Masters Theses

Lymph is primarily composed of fluid and proteins from the blood circulatory system that drain into the space surrounding cells, interstitial space. From the interstitial space, the fluid enters and circulates in the lymphatic system until it is delivered into the venous system. In contrast to the blood circulatory system, the lymphatic system lacks a central pumping organ dictating the predominant driving pressure and velocity of lymph. Transport of lymph via capillaries, pre-collecting and collecting lymphatic vessels relies on the synergy between pressure gradients, local tissue motion, valves and lymphatic vessel contractility. The direction of lymph transport is regulated by …


Influence Of Scapular Notching On Contact Mechanics And Simulator Wear Of Reverse Total Shoulder Arthroplasty Implants, Michael William Griffiths Oct 2017

Influence Of Scapular Notching On Contact Mechanics And Simulator Wear Of Reverse Total Shoulder Arthroplasty Implants, Michael William Griffiths

Electronic Thesis and Dissertation Repository

Scapular notching is a common complication of reverse total shoulder arthroplasty (RTSA) wherein the predominant focus of current literature has been on changes in osseous anatomy. However, the implications on RTSA performance from the damaged humeral cup is largely unknown. Therefore the present work describes the effects of the initiation and propagation of the humeral cup defect resulting from scapular notching through the use of finite element modeling and wear simulation, in order to assess changes in RTSA contact mechanics and tribological properties. A significant decrease in articular contact area and increase in maximum contact stress values was found for …


Experimental Measurements Of Far Field Cough Airflows Produced By Healthy And Influenza- Infected Human Subjects, Ahmed Faraj Alarbi Mohamed Sep 2017

Experimental Measurements Of Far Field Cough Airflows Produced By Healthy And Influenza- Infected Human Subjects, Ahmed Faraj Alarbi Mohamed

Electronic Thesis and Dissertation Repository

The present work details an experimental study of the cough airflow fields produced by subjects infected with influenza and when they are convalescent, together with data from healthy cohorts. The PIV and HWA measurements were taken far downstream at 1 m from the source within a cough chamber, along with droplet sampling at two different locations and nasal swabs from the sick subjects. The measured data over different seasons were used to evaluate and compare the results from sick, convalescent and healthy subjects. Although a total of 8 sick participants from winter 2014 and 2017 yielded positive nasal swab analysis, …


Bacterial Motility And Its Role In Biofilm Formation, Clayton J. Culp, Arezoo M. Ardekani, Adib Ahmadzadegan Aug 2017

Bacterial Motility And Its Role In Biofilm Formation, Clayton J. Culp, Arezoo M. Ardekani, Adib Ahmadzadegan

The Summer Undergraduate Research Fellowship (SURF) Symposium

Bacterial biofilms are known to cause millions of dollars in damage in the medical industry per year via infection of central venous catheters, urinary catheters, and mechanical heart valves. Unfortunately, there are some characteristics of biofilm formation that are yet to be fully understood. Recently much work has been done to investigate the motility characteristics of bacteria with hopes of better understanding the phenomena of biofilm formation. Still, one of the least understood stages is bacterial attachment or adhesion, a process designed to anchor bacteria in an advantageous environment. Providing a better understanding of bacterial motility near solid interfaces will …


Intrinsic Regulators Of Actomyosin Contractility Engendering Pulsatile Behaviors, Qilin Yu, Jing Li, Taeyoon Kim Aug 2017

Intrinsic Regulators Of Actomyosin Contractility Engendering Pulsatile Behaviors, Qilin Yu, Jing Li, Taeyoon Kim

The Summer Undergraduate Research Fellowship (SURF) Symposium

Actomyosin contractility regulates various biological processes including cell migration, muscle contraction, and tissue morphogenesis. Cell cortex underlying a membrane, which is a representative actomyosin network in eukaryote cells, exhibits dynamic contractile behaviors. Interestingly, the cell cortex shows reversible aggregation of actin and myosin called pulsatile contraction in diverse cellular phenomena, such as embryogenesis and tissue morphogenesis. While contractile behaviors have been studied in several in vitro experiments and computational studies, none of them demonstrated the pulsatile contraction of actomyosin networks observed in vivo. Here, we used an agent-based computational model based on Brownian dynamics to identify factors facilitating the pulsatile …


A Parametric Study Of The Mechanics Of Different Skin Flap Techniques, Steven J. Meza, Adrián Tepole Buganza Aug 2017

A Parametric Study Of The Mechanics Of Different Skin Flap Techniques, Steven J. Meza, Adrián Tepole Buganza

The Summer Undergraduate Research Fellowship (SURF) Symposium

In modern day plastic and reconstructive surgeries numerous skin flap designs have been developed and are used to close open wounds. Skin flaps are developed with the intention of imposing minimal tension in skin closure. Excessive tension can lead to poor blood flow that result in post-surgery complications such as necrosis. Currently there is no standard in choosing a skin flap design and a surgeon's choice is based personal experience. A comparison of the mechanical loading in these various designs has not yet been done. We have developed a parametric study, using finite element analysis, of two advancement skin flaps …


Optimization Of Prosthetic Hands: Utilizing Modularity To Improve Grip Force, Grasp, And Versatility, Jordan William Harris Aug 2017

Optimization Of Prosthetic Hands: Utilizing Modularity To Improve Grip Force, Grasp, And Versatility, Jordan William Harris

UNLV Theses, Dissertations, Professional Papers, and Capstones

It has been demonstrated that although many varieties of upper limb prosthetics exist, commercially available prosthetics are outdated and unsatisfactory. Ineffectiveness and limitations have led to some prosthesis wearers having to own multiple devices, whereas others have given up on them entirely. Even though ample research has been conducted to design and test new hand designs, the industry appears to rest in an overall stagnated state.

It was proposed here, that one problem with prosthetic research is an excess of variables involved in testing, and therefore the improper application of the scientific method. It seems that each time a research …


Biomechanical Testing Of An Exercise For Strengthening The Proximal Femur., Alyssa Osbourne Aug 2017

Biomechanical Testing Of An Exercise For Strengthening The Proximal Femur., Alyssa Osbourne

Electronic Theses and Dissertations

Based on the principles of cutting edge bone remodeling research, a unique therapeutic exercise device was designed specifically to improve bone quality at the most critical location of the proximal femur prone to fracture: the superior-lateral femoral neck where the fracture first initiates during a fall. The exercise/device is intended to work by inducing enough strain in the bone to stimulate the body’s natural bone remodeling mechanisms to increase bone density in the proximal femur and consequently prevent a fracture from arising if a fall to the side does occur.

In order to test the proposed exercise, experiments simulating the …


A Magnetic Resonance Compatible Knee Extension Ergometer, Youssef Jaber Jul 2017

A Magnetic Resonance Compatible Knee Extension Ergometer, Youssef Jaber

Masters Theses

The product of this thesis aims to enable the study of the biochemical and physical dynamics of the lower limbs at high levels of muscle tension and fast contraction speeds. This is accomplished in part by a magnetic resonance (MR) compatible ergometer designed to apply a load as a torque of up to 420 Nm acting against knee extension at speeds as high as 4.7 rad/s. The system can also be adapted to apply the load as a force of up to 1200 N acting against full leg extension. The ergometer is designed to enable the use of magnetic resonance …


Development And Evaluation Of A Biocompatible Electroactive Sensor For Continuous Blood Pressure Measurement., Scott D. Cambron May 2017

Development And Evaluation Of A Biocompatible Electroactive Sensor For Continuous Blood Pressure Measurement., Scott D. Cambron

Electronic Theses and Dissertations

Piezo-active composites have been implemented for sensing and transduction for decades. The 0-3 ceramic/polymer composite is one of the most common composite types used for sensing applications, owing to their tailorable properties of the two-phase composition, consisting of a three-dimensionally connected polymer/rubber matrix (inactive phase) with a dispersion of isolated piezo-ceramic particles (active phase). This thesis describes a method to develop novel biocompatible perivascular band comprised of a two-phase piezo-active composite to be fabricated using simple manufacturing processes. Biomaterials such as tissue scaffolds comprised of silk fibroin (SF) and chitosan (CS), and biocompatible soft rubbers will be implemented as the …


Design And Validation Of An In Vivo Long-Term Attachment Capsule Robot, Wanchuan Xie May 2017

Design And Validation Of An In Vivo Long-Term Attachment Capsule Robot, Wanchuan Xie

Department of Mechanical and Materials Engineering: Dissertations, Theses, and Student Research

The invention of capsule endoscopy (CE) made the non-invasive monitoring of the entire small bowel possible and became the primary means for diagnosing small bowel pathology. In the last decade, capsule robots have been transformed from diagnostic devices into a widely studied biomedical platform with the potential for active locomotion, drug delivery and therapeutic capabilities. To perform accurate on-site drug release and therapy, it is necessary for a capsule robot to be able to attach to the intestinal tissue and maintain its position long-term. Design challenges derive from the task of long-term mucosal adhesion which requires firm, quick-response attachment without …


Estimation Of The Centre Of Mass From Motion Capture And Force Plate Recordings: A Study On The Elderly, Sebastien Cotton, Michele Vanoncini, Philippe Fraisse, Nacim Ramdani, Emel Demircan, Andrew P. Murray, Thierry Keller Feb 2017

Estimation Of The Centre Of Mass From Motion Capture And Force Plate Recordings: A Study On The Elderly, Sebastien Cotton, Michele Vanoncini, Philippe Fraisse, Nacim Ramdani, Emel Demircan, Andrew P. Murray, Thierry Keller

Andrew P. Murray

The estimation of the centre of mass position in humans is usually based on biomechanical models developed from anthropometric tables. This method can potentially introduce errors in studies involving elderly people, since the ageing process is typically associated with a modification of the distribution of the body mass. In this paper, an alternative technique is proposed, and evaluated with an experimental study on 9 elderly volunteers. The technique is based on a virtual chain, identified from experimental data and locating the subject's centre of mass. Its configuration defines the location of the centre of mass, and is a function of …


Biophysical Tools To Study Cellular Mechanotransduction, Ismeel Muhamed, Farhan Chowdhury, Venkat Maruthamuthu Feb 2017

Biophysical Tools To Study Cellular Mechanotransduction, Ismeel Muhamed, Farhan Chowdhury, Venkat Maruthamuthu

Mechanical & Aerospace Engineering Faculty Publications

The cell membrane is the interface that volumetrically isolates cellular components from the cell's environment. Proteins embedded within and on the membrane have varied biological functions: reception of external biochemical signals, as membrane channels, amplification and regulation of chemical signals through secondary messenger molecules, controlled exocytosis, endocytosis, phagocytosis, organized recruitment and sequestration of cytosolic complex proteins, cell division processes, organization of the cytoskeleton and more. The membrane's bioelectrical role is enabled by the physiologically controlled release and accumulation of electrochemical potential modulating molecules across the membrane through specialized ion channels (e.g., Na, Ca2+, K channels). …


Design And Control Of A Powered Rowing Machine With Programmable Impedance, Jose Humberto De La Casas Zolezzi Jan 2017

Design And Control Of A Powered Rowing Machine With Programmable Impedance, Jose Humberto De La Casas Zolezzi

ETD Archive

Due to the rise of obesity, diabetes and cardiovascular disease, research in human performance and physical activity has received increased attention. Rowing machines are used for performance improvements through concentric exercises, however a combination of concentric and eccentric actions is known to improve the effectiveness of training. In this work, a conventional rowing machine was modified to include an electric motor and a robust impedance control system, enabling programmable impedance with concentric and eccentric capabilities. Eccentric exercises are known to contribute significantly to the efficacy of training and to diminish the detrimental effects of humans operating in microgravity for long …


Age-Related Differences In The Lumbopelvic Kinematics During The Trunk Motions In The Anatomical Planes, Milad Vazirian Jan 2017

Age-Related Differences In The Lumbopelvic Kinematics During The Trunk Motions In The Anatomical Planes, Milad Vazirian

Theses and Dissertations--Biomedical Engineering

Management and control of the low back pain as an important health problem in the industrial societies necessitates to investigate how the risk of this disease is affected by aging. Since the abnormalities of the lumbopelvic kinematics are related to the existence or risk of low back injuries, the objective of this dissertation was set to find the age-related differences in lumbopelvic kinematics when performing basic trunk motions reaching to range of motion in different anatomical planes.

A cross-sectional study was designed where sixty asymptomatic individuals between 20–70 years old with no confounding health condition, no current or previous highly …


Skintronics: Wireless, Skin-Wearable Electronics For Monitoring Of Electrocardiogram, Matthew B. Piper, Woon-Hong Yeo, Yongkuk Lee Jan 2017

Skintronics: Wireless, Skin-Wearable Electronics For Monitoring Of Electrocardiogram, Matthew B. Piper, Woon-Hong Yeo, Yongkuk Lee

Undergraduate Research Posters

The ECGs I micro-fabricate are designed to be flexible, stretchable and wireless circuits that can be applied to the skin directly. The device is encased in a conformal, silicon-like substrate, that allows the ECG to be attached with the electrodes. Each electrode has been previously measured and verified that it will be correctly placed for an accurate reading. Prototyping this ECG/electrode device allows the user to mount the prototype directly to the patient without having to attach and wire ten other electrodes. This prototype solves the issue that comes about when a doctor, nurse or emergency medical technician must attach …