Frame It - Thoughts On Education, Reducing Carbon And Vapour, Joseph Little, Robbie Cousins Jun 2008

Frame It - Thoughts On Education, Reducing Carbon And Vapour, Joseph Little, Robbie Cousins

Articles

Joseph Little believes timber frame can be the backbone of a new generation of low-carbon, energy-efficient housing, and be used as an intelligent response to Climate Change and fuel prices. But he tells Robbie Cousins that timber frame manufacturers, suppliers and architects need to gear-up and work more closely together if the true potential of this vision is to be realised.

Joseph Little’s chief bugbear is poor construction standards & details on site and the core of this issue is how the knowledge set of architects and builders and how standards are controlled. The seeds of this idea may have …


Baugruppe - Lessons From Freiburg On Cooperative Housing : Lessons From Freiburg On Cooperative Housing, Joseph Little Jan 2007

Baugruppe - Lessons From Freiburg On Cooperative Housing : Lessons From Freiburg On Cooperative Housing, Joseph Little

Articles

Creating Sustainable Communities in the UK and Ireland

The Genesis of Quartier Vauban


Improving Access To Housing For People With Disabilities., Myles Keaveney Jan 2007

Improving Access To Housing For People With Disabilities., Myles Keaveney

Articles

No abstract provided.


Thermal Performance Of Low Approach Evaporative Cooling Systems In Buildings, Ben Costelloe, Donal Finn Apr 2006

Thermal Performance Of Low Approach Evaporative Cooling Systems In Buildings, Ben Costelloe, Donal Finn

Conference Papers

Meteorological enthalpy analysis of temperate and maritime climates above 45˚N suggests that the water-side evaporative cooling technique has considerable unrealised potential with contemporary "high temperature" building cooling systems - such as chilled ceilings. As low approach conditions are the key to exploiting the cooling potential of the ambient air, thermal performance at such conditions needs to be investigated. To address the research issues a test rig, based on an open cooling tower and plate heat exchanger and designed to maximise evaporative cooling potential, has been constructed at DIT. A combination of experimental measurement and analysis is used in the investigations. …


A Critical Appraisal Of The Opportunities Currently Available For A More Energy Conscious Approach To Residential Building In Ireland, John Mcdonagh, Louis Gunnigan Jan 2006

A Critical Appraisal Of The Opportunities Currently Available For A More Energy Conscious Approach To Residential Building In Ireland, John Mcdonagh, Louis Gunnigan

Conference papers

This paper focuses on the particular advantages which off-site housing construction has over the more traditional methods of building especially where the efficient use and conservation of energy is concerned. It will explain why modern innovative methods of house construction not only have a clear advantage environmentally (big reductions in CO2 emissions) but also deliver substantial benefits to the end user or householder especially in the form of lower energy bills.

The ecological argument for off-site systems is a very powerful one but on its own is still unlikely to be the prime driver for widespread implementation. That growth is …


Access To Buildings For People With Disabilities, Myles Keaveney Jan 2006

Access To Buildings For People With Disabilities, Myles Keaveney

Articles

No abstract provided.


Thermal Efficiency Characteristics Of Indirect Evaporative Cooling Systems, Ben Costelloe, Donal Finn May 2005

Thermal Efficiency Characteristics Of Indirect Evaporative Cooling Systems, Ben Costelloe, Donal Finn

Conference Papers

Recent developments in enhancing heat transfer in cooling towers, together with the success of chilled ceilings, have prompted a review of the evaporative cooling technique. in temperate maritime climates. The thermal efficiency of such systems is a key parameter, as a measure of the degree to which the system has succeeded in exploiting the cooling potential of the ambient air. This paper presents the results of experimental research into the thermal efficiency of a water-side open indirect evaporative cooling test rig designed to achieve low (1-4 K) approach conditions. Secondary efficiencies in the range 0.24-0.76 have been achieved.


Research Into Evaporative Cooling Of Buildings In Maritime Climates, Ben Costelloe, Donal Finn Sep 2002

Research Into Evaporative Cooling Of Buildings In Maritime Climates, Ben Costelloe, Donal Finn

Reports

Concern with environmental emissions has focused attention on traditional forms of energy use in buildings, with a view to reducing and making more rational use of energy consumption. One area of concern is the traditional, refrigeration based, commercial air conditioning system, which has high levels of electrical power consumption in fans and refrigeration compressors. There is also concern among building owners and design teams, supported by the PROBE series of post occupancy studies, conducted by the CIBSE, that many buildings, with traditional forms of air conditioning, under perform in terms of occupant satisfaction, ease of operation and control, maintenance costs …


Evaporative Cooling Availability In Water Based Sensible Cooling Systems, Ben Costelloe, Donal Finn Sep 2001

Evaporative Cooling Availability In Water Based Sensible Cooling Systems, Ben Costelloe, Donal Finn

Conference Papers

Recent developments have prompted a review of evaporative cooling technology as an effective means of cooling modern deep plan buildings. Prominent among these developments is the success of high temperature sensible cooling systems, such as chilled ceilings, which require a supply of cooling water at 14 to 18°C. Crucial to the success of evaporative cooling technology, as a significant means of cooling in modern applications, is the ability to generate cooling water, in an indirect circuit, at a temperature which closely approaches the ambient adiabatic saturation temperature or wet bulb temperature. Recent research in this area has shown that it …