Open Access. Powered by Scholars. Published by Universities.®

Other Physics Commons™

Open Access. Powered by Scholars. Published by Universities.®

The Texas Medical Center Library

Discipline
Keyword
Publication Year

Articles 61 - 63 of 63

Full-Text Articles in Other Physics

Commissioning An Anthropomorphic Spine And Lung Phantom For Remote Dose Verification Of Institutions Participating In Rtog 0631, Douglas F. Caruthers May 2010

Commissioning An Anthropomorphic Spine And Lung Phantom For Remote Dose Verification Of Institutions Participating In Rtog 0631, Douglas F. Caruthers

Dissertations and Theses (Open Access)

The RPC developed a new phantom to ensure comparable and consistent radiation administration in spinal radiosurgery clinical trials. This study assessed the phantom’s dosimetric and anatomic utility. The ‘spine phantom’ is a water filled thorax with anatomy encountered in spinal radiosurgery: target volume, vertebral column, spinal canal, esophagus, heart, and lungs. The dose to the target volume was measured with axial and sagittal planes of radiochromic film and thermoluminescent dosimeters (TLD). The dose distributions were measured with the radiochromic film calibrated to the absolute dose measured by the TLD. Four irradiations were administered: a four angle box plan, a seven …


Range Adaptive Proton Therapy For Prostate Cancer, Adam D. Melancon May 2010

Range Adaptive Proton Therapy For Prostate Cancer, Adam D. Melancon

Dissertations and Theses (Open Access)

Purpose: The rapid distal falloff of a proton beam allows for sparing of normal tissues distal to the target. However proton beams that aim directly towards critical structures are avoided due to concerns of range uncertainties, such as CT number conversion and anatomy variations. We propose to eliminate range uncertainty and enable prostate treatment with a single anterior beam by detecting the proton’s range at the prostate-rectal interface and adaptively adjusting the range in vivo and in real-time.

Materials and Methods: A prototype device, consisting of an endorectal liquid scintillation detector and dual-inverted Lucite wedges for range compensation, was designed …


Thoracic Radiotherapy Treatment Planning With Cine Pet/Ct, Adam C. Riegel May 2010

Thoracic Radiotherapy Treatment Planning With Cine Pet/Ct, Adam C. Riegel

Dissertations and Theses (Open Access)

Purpose: Respiratory motion causes substantial uncertainty in radiotherapy treatment planning. Four-dimensional computed tomography (4D-CT) is a useful tool to image tumor motion during normal respiration. Treatment margins can be reduced by targeting the motion path of the tumor. The expense and complexity of 4D-CT, however, may be cost-prohibitive at some facilities. We developed an image processing technique to produce images from cine CT that contain significant motion information without 4D-CT. The purpose of this work was to compare cine CT and 4D-CT for the purposes of target delineation and dose calculation, and to explore the role of PET in target …