Open Access. Powered by Scholars. Published by Universities.®

Other Physics Commons™

Open Access. Powered by Scholars. Published by Universities.®

Medical Specialties

Institution
Keyword
Publication Year
Publication
Publication Type

Articles 31 - 45 of 45

Full-Text Articles in Other Physics

Development Of 3d-Printed Patient Specific Bolus For Clinical Use In To Tal Scalp Irradiation, Garrett Baltz May 2018

Development Of 3d-Printed Patient Specific Bolus For Clinical Use In To Tal Scalp Irradiation, Garrett Baltz

Dissertations and Theses (Open Access)

Total scalp irradiation (TSI) is a specialized radiation therapy technique that aims to deliver a uniform dose to the entire scalp. Original electron-based TSI techniques had limited homogeneity due to hot and cold spots created at field junctions due to the multiple matched fields that were required to treat the entire scalp. The transition to photon volumetric-modulated arc therapy based TSI techniques has improved homogeneity, to the point where non-conformal bolus is now a limiting factor. Bolus is required to build-up full dose to the scalp surface in total scalp irradiation. Creating bolus that is conformal to the scalp is …


Motion-Induced Artifact Mitigation And Image Enhancement Strategies For Four-Dimensional Fan-Beam And Cone-Beam Computed Tomography, Matthew J. Riblett Jan 2018

Motion-Induced Artifact Mitigation And Image Enhancement Strategies For Four-Dimensional Fan-Beam And Cone-Beam Computed Tomography, Matthew J. Riblett

Theses and Dissertations

Four dimensional imaging has become part of the standard of care for diagnosing and treating non-small cell lung cancer. In radiotherapy applications 4D fan-beam computed tomography (4D-CT) and 4D cone-beam computed tomography (4D-CBCT) are two advanced imaging modalities that afford clinical practitioners knowledge of the underlying kinematics and structural dynamics of diseased tissues and provide insight into the effects of regular organ motion and the nature of tissue deformation over time. While these imaging techniques can facilitate the use of more targeted radiotherapies, issues surrounding image quality and accuracy currently limit the utility of these images clinically.

The purpose of …


On Syntropy & Precognitive Interdiction Based On Wheeler-Feynman’S Absorber Theory, Florentin Smarandache, Victor Christianto, Yunita Umniyati Aug 2017

On Syntropy & Precognitive Interdiction Based On Wheeler-Feynman’S Absorber Theory, Florentin Smarandache, Victor Christianto, Yunita Umniyati

Branch Mathematics and Statistics Faculty and Staff Publications

It has been known for long time that intuition plays significant role in many professions and human life, including in entrepreneurship, government, and also in detective or law enforcement activities. Women are known to possess better intuitive feelings or “hunch” compared to men. Despite these examples, such a precognitive interdiction is hardly accepted in established science. In this letter, we discuss briefly the advanced solutions of Maxwell equations, and then explore plausible connection between syntropy and precognition.


Improvements In Four-Dimensional And Dual Energy Computed To Mography, Rachael M. Martin Aug 2017

Improvements In Four-Dimensional And Dual Energy Computed To Mography, Rachael M. Martin

Dissertations and Theses (Open Access)

Dual energy and 4D computed tomography (CT) seek to address some of the limitations in traditional CT imaging. Dual energy CT, among other purposes, allows for the quantification and improved visualization of contrast materials, and 4D CT is often used in radiation therapy applications as it allows for the visualization and quantification of object motion. While much research has been done with these technologies, areas remain for potential improvement, both in preclinical and clinical settings, which will be explored in this dissertation. Preclinical dual energy cone-beam CT (CBCT) can benefit from wider separation between the peak energy of the two …


Identifying Treatment Planning System Errors In Iroc-Houston Head And Neck Phantom Irradiations, James Kerns Aug 2016

Identifying Treatment Planning System Errors In Iroc-Houston Head And Neck Phantom Irradiations, James Kerns

Dissertations and Theses (Open Access)

Treatment Planning System (TPS) errors can affect large numbers of cancer patients receiving radiation therapy. Using an independent recalculation system, the Imaging and Radiation Oncology Core-Houston (IROC-H) can identify institutions that have not sufficiently modelled their linear accelerators in their TPS model. Linear accelerator point measurement data from IROC-H’s site visits was aggregated and analyzed from over 30 linear accelerator models. Dosimetrically similar models were combined to create “classes”. The class data was used to construct customized beam models in an independent treatment dose verification system (TVS). Approximately 200 head and neck phantom plans from 2012 to 2015 were recalculated …


Quantification Of Imrt Severity Scores For Improvement Of Fmea Results, Jacqueline T. Faught Aug 2015

Quantification Of Imrt Severity Scores For Improvement Of Fmea Results, Jacqueline T. Faught

Dissertations and Theses (Open Access)

Accurate delivery of intensity modulation radiation therapy (IMRT) requires perfect execution of a long, complicated chain of events; failure of any component of this process may contribute to dose delivery errors, compromising treatment quality and, more importantly, patient safety. Prospective, process-wide risk mitigation techniques are becoming more prevalent in radiotherapy to establish comprehensive quality management (QM) programs, such as failure modes and effects analysis (FMEA). The subjective nature of the ordinal scores used for FMEA leads questionable reliability and validity of the results. Additionally, physics components are commonly grouped together, leaving out valuable details important to physics QM. While the …


Characterization Of Low Density Intracranial Lesions Using Dual-Energy Computed To Mography, Jessica L. Nute May 2015

Characterization Of Low Density Intracranial Lesions Using Dual-Energy Computed To Mography, Jessica L. Nute

Dissertations and Theses (Open Access)

Calcific and hemorrhagic foci of susceptibility are frequently encountered on routine brain MR studies. Both etiologies cause variations in local magnetic field strength, leading to dark regions on the MR images that cannot be classified. Single-energy CT (SECT) can be used to identify lesions with attenuation over 100 HU as calcific, however lesions with lower attenuation cannot be reliably identified. While calcific lesions are unlikely to cause harm, hemorrhagic lesions carry a risk of subsequent intracranial bleeding; as such, identification of hemorrhage is vital in preventing the inappropriate use of anticoagulant medications in patients with hemorrhagic lesions.

Given there currently …


Image-Guided Proton Therapy For Online Dose-Evaluation And Adaptive Planning, Joey P. Cheung May 2014

Image-Guided Proton Therapy For Online Dose-Evaluation And Adaptive Planning, Joey P. Cheung

Dissertations and Theses (Open Access)

The main advantage for using protons in radiotherapy is their finite range in patients, allowing for potential improved sparing of normal tissues. However, this comes at a cost of increased sensitivity to range uncertainties. Density changes along the beam path will affect the proton range and the resultant dose distribution, making it difficult to estimate the impact of visible anatomic changes to the patient dose distribution. In order to better understand the effect of anatomy change on proton dose, some form of treatment-time verification is required and methods to correct for observed changes would be beneficial. Therefore, this project aims …


Three‐Dimensional Brain Mri For Dbs Patients Within Ultra‐Low Radiofrequency Power Limits, Subhendra N. Sarkar, Efstathios Papavassiliou, David Hackney, David Alsop, Ananth Madhuranthakam, Ludy Shih, Reed Busse, Susan Laruche, Rafeeque Bhadelia Jan 2014

Three‐Dimensional Brain Mri For Dbs Patients Within Ultra‐Low Radiofrequency Power Limits, Subhendra N. Sarkar, Efstathios Papavassiliou, David Hackney, David Alsop, Ananth Madhuranthakam, Ludy Shih, Reed Busse, Susan Laruche, Rafeeque Bhadelia

Publications and Research

Background: For patients with deep brain stimulators (DBS), local absorbed radiofrequency (RF) power is unknown and is much higher than what the system estimates. We developed a comprehensive, highquality brain magnetic resonance imaging (MRI) protocol for DBS patients utilizing three-dimensional (3D) magnetic resonance sequences at very low RF power. Methods: Six patients with DBS were imaged (10 sessions) using a transmit/receive head coil at 1.5 Tesla with modified 3D sequences within ultra-low specific absorption rate (SAR) limits (0.1 W/kg) using T2, fast fluid-attenuated inversion recovery (FLAIR) and T1- weighted image contrast. Tissue signal and tissue contrast from the low-SAR images …


An Investigation Of Nurbs-Based Deformable Image Registration, Travis J. Jacobson Jan 2014

An Investigation Of Nurbs-Based Deformable Image Registration, Travis J. Jacobson

Theses and Dissertations

Deformable image registration (DIR) is an essential tool in medical image processing. It provides a means to combine image datasets, allowing for intra-subject, inter-subject, multi-modality, and multi-instance analysis, as well as motion detection and compensation. One of the most popular DIR algorithms models the displacement vector field (DVF) as B-splines, a sum of piecewise polynomials with coefficients that enable local shape control. B-splines have many advantageous properties in the context of DIR, but they often struggle to adequately model steep local gradients and discontinuities. This dissertation addresses that limitation by proposing the replacement of conventional B-splines with a generalized formulation …


The Development And Implementation Of An Anthropomorphic Head Phantom For The Assessment Of Proton Therapy Treatment Procedures, Paige A. Summers Aug 2011

The Development And Implementation Of An Anthropomorphic Head Phantom For The Assessment Of Proton Therapy Treatment Procedures, Paige A. Summers

Dissertations and Theses (Open Access)

Proton therapy has become an increasingly more common method of radiation therapy, with the dose sparing to distal tissue making it an appealing option, particularly for treatment of brain tumors. This study sought to develop a head phantom for the Radiological Physics Center (RPC), the first to be used for credentialing of institutions wishing to participate in clinical trials involving brain tumor treatment of proton therapy. It was hypothesized that a head phantom could be created for the evaluation of proton therapy treatment procedures (treatment simulation, planning, and delivery) to assure agreement between the measured dose and calculated dose within …


An Implantable Mosfet Dosimeter Modified To Act As A Fiducial Marker, Joseph S. Dick Aug 2010

An Implantable Mosfet Dosimeter Modified To Act As A Fiducial Marker, Joseph S. Dick

Dissertations and Theses (Open Access)

In external beam radiation therapy, it is imperative that the prescribed dose is administered to the correct location and in the correct amount. Though several ex vivo methods of quality assurance are currently employed to achieve this goal, verifying that the correct dose is received within the patient in situ is impossible without the capability of measuring dose inside the patient. Recently, a method of measuring dose delivered within the patient has been developed, an implantable MOSFET dosimeter. This dosimeter is implanted within the patient and records the dose received. Since the dosimeter is implanted in the patient, it could …


Benchmarking And Implementation Of A New Independent Monte Carlo Dose Calculation Quality Assurance Audit To Ol For Clinical Trials, Scott E. Davidson Aug 2010

Benchmarking And Implementation Of A New Independent Monte Carlo Dose Calculation Quality Assurance Audit To Ol For Clinical Trials, Scott E. Davidson

Dissertations and Theses (Open Access)

Introduction Commercial treatment planning systems employ a variety of dose calculation algorithms to plan and predict the dose distributions a patient receives during external beam radiation therapy. Traditionally, the Radiological Physics Center has relied on measurements to assure that institutions participating in the National Cancer Institute sponsored clinical trials administer radiation in doses that are clinically comparable to those of other participating institutions. To complement the effort of the RPC, an independent dose calculation tool needs to be developed that will enable a generic method to determine patient dose distributions in three dimensions and to perform retrospective analysis of radiation …


Dynamic Chemical Shift Imaging For Image-Guided Thermal Therapy, Brian A. Taylor Aug 2010

Dynamic Chemical Shift Imaging For Image-Guided Thermal Therapy, Brian A. Taylor

Dissertations and Theses (Open Access)

Magnetic resonance temperature imaging (MRTI) is recognized as a noninvasive means to provide temperature imaging for guidance in thermal therapies. The most common method of estimating temperature changes in the body using MR is by measuring the water proton resonant frequency (PRF) shift. Calculation of the complex phase difference (CPD) is the method of choice for measuring the PRF indirectly since it facilitates temperature mapping with high spatiotemporal resolution. Chemical shift imaging (CSI) techniques can provide the PRF directly with high sensitivity to temperature changes while minimizing artifacts commonly seen in CPD techniques. However, CSI techniques are currently limited by …


Thoracic Radiotherapy Treatment Planning With Cine Pet/Ct, Adam C. Riegel May 2010

Thoracic Radiotherapy Treatment Planning With Cine Pet/Ct, Adam C. Riegel

Dissertations and Theses (Open Access)

Purpose: Respiratory motion causes substantial uncertainty in radiotherapy treatment planning. Four-dimensional computed tomography (4D-CT) is a useful tool to image tumor motion during normal respiration. Treatment margins can be reduced by targeting the motion path of the tumor. The expense and complexity of 4D-CT, however, may be cost-prohibitive at some facilities. We developed an image processing technique to produce images from cine CT that contain significant motion information without 4D-CT. The purpose of this work was to compare cine CT and 4D-CT for the purposes of target delineation and dose calculation, and to explore the role of PET in target …