Open Access. Powered by Scholars. Published by Universities.®

Other Physics Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 11 of 11

Full-Text Articles in Other Physics

Digital Twins Of The Living Knee: From Measurements To Model, Thor Erik Andreassen Nov 2023

Digital Twins Of The Living Knee: From Measurements To Model, Thor Erik Andreassen

Electronic Theses and Dissertations

Modern medicine has dramatically improved the lives of many. In orthopaedics, robotic surgery has given clinicians superior accuracy when performing interventions over conventional methods. Nevertheless, while these and many other methods are available to ensure treatments are performed successfully, far fewer methods exist to predict the proper treatment option for a given person. Clinicians are forced to categorize individuals, choosing the best treatment on “average.” However, many individuals differ significantly from the “average” person, for which many of these treatments are designed. Going forward, a method of testing, evaluating, and predicting different treatment options' short- and long-term effects on an …


Towards Clinical Microscopic Fractional Anisotropy Imaging, Nico Jj Arezza Aug 2023

Towards Clinical Microscopic Fractional Anisotropy Imaging, Nico Jj Arezza

Electronic Thesis and Dissertation Repository

Microscopic fractional anisotropy (µFA) is a diffusion-weighted magnetic resonance imaging (dMRI) metric that is sensitive to neuron microstructural features without being confounded by the orientation dispersion of axons and dendrites. µFA may potentially act as a surrogate biomarker for neurodegeneration, demyelination, and other pathological changes to neuron microstructure with greater specificity than other dMRI techniques that are sensitive to orientation dispersion, such as diffusion tensor imaging. As with many advanced imaging techniques, µFA is primarily used in research studies and has not seen use in clinical settings.

The primary goal of this Thesis was to assess the clinical viability of …


The Future Is Now In Twisted Coil Polymer Actuators (Tcpa), Ryan Ronquillo May 2023

The Future Is Now In Twisted Coil Polymer Actuators (Tcpa), Ryan Ronquillo

Electronic Theses and Dissertations

This thesis aimed to fabricate and test twisted coiled polymer actuators (TCPA) to understand the mechanical and thermal aspects of this artificial muscle fiber. The purpose of this thesis was to find a linear relationship using the LVDT sensor, fabricating TCPA fibers, and interpreting the data. The project tested whether nylon/polymer could be used as a better artificial muscle fiber.

This research accomplished three goals: (1) designing and fabricating a system capable of creating supercoiled muscle fibers consistently, (2) calibrating the Linear Variable Differential Transformer (LVDT) and Core, and (3) analyzing/interpreting the data of the Twisted Coiled Polymer Actuators (TCPA) …


Thermal Properties Of 18f-Fdg Uptake And Imaging In Positron Emission Tomography Scans Of Cancerous Cells, Carleigh R. Eagle Aug 2021

Thermal Properties Of 18f-Fdg Uptake And Imaging In Positron Emission Tomography Scans Of Cancerous Cells, Carleigh R. Eagle

PANDION: The Osprey Journal of Research and Ideas

Positron Emission Tomography (PET) scans can utilize a radioactive tracer, in this case 2-deoxy2-[fluorine-18] fluoro-D-glucose (18F-FDG), to visualize malignant tumors in cancer patients. The uptake was compared to glucose to understand the difference in thermal properties, which contribute to the ability to image the cancerous cells. The uptake of 18F-FDG by cancer cells and the imaging process of positron emission tomography were reviewed from a thermodynamic perspective. Gastrointestinal and neurological imaging techniques were reviewed to understand the role of PET imaging in different areas of the human body.


Heel Down And Toe-Off Time Measured With Ultrasonic Doppler System And Force Plate Sensor, Sabin Timsina May 2020

Heel Down And Toe-Off Time Measured With Ultrasonic Doppler System And Force Plate Sensor, Sabin Timsina

Honors Theses

Collie Box is a medical device that measures the gait parameters of the person walk- ing in front of it. This device uses the Ultrasonic Doppler system to extract the heel-contact and toe-off times of a person walking within the range of 2-10 meters. These times are used to determine the leg’s swing phase and double stance times. The ultrasonic transducer of 10mm diameter is driven at 40kHz. At the time of the heel-contact and toe-off, foot velocity is zero while the torso part of the human body is still in motion. The wide directivity of 10mm diameter ultrasonic transducer …


Can A Comprehensive Transition Plan To Barefoot Running Be The Solution To The Injury Epidemic In American Endurance Runners?, Michael A. Scarlett Jan 2018

Can A Comprehensive Transition Plan To Barefoot Running Be The Solution To The Injury Epidemic In American Endurance Runners?, Michael A. Scarlett

CMC Senior Theses

Fossils belonging to the genus Homo, dating as far back as two million years ago, exhibit uniquely efficient features suggesting that early humans had evolved to become exceptional endurance runners. Although they did not have the cushion or stability-control features provided in our modern day running shoes, our early human ancestors experienced far less of the running-related injuries we experience today. The injury rate has been estimated as high as 90% annually for Americans training for a marathon and as high as 79% annually for all American endurance runners. There is an injury epidemic in conventionally shod populations that …


System Characterizations And Optimized Reconstruction Methods For Novel X-Ray Imaging, Huifeng Guan Dec 2017

System Characterizations And Optimized Reconstruction Methods For Novel X-Ray Imaging, Huifeng Guan

McKelvey School of Engineering Theses & Dissertations

In the past decade there have been many new emerging X-ray based imaging technologies developed for different diagnostic purposes or imaging tasks. However, there exist one or more specific problems that prevent them from being effectively or efficiently employed. In this dissertation, four different novel X-ray based imaging technologies are discussed, including propagation-based phase-contrast (PB-XPC) tomosynthesis, differential X-ray phase-contrast tomography (D-XPCT), projection-based dual-energy computed radiography (DECR), and tetrahedron beam computed tomography (TBCT). System characteristics are analyzed or optimized reconstruction methods are proposed for these imaging modalities. In the first part, we investigated the unique properties of propagation-based phase-contrast imaging technique …


System Optimization And Iterative Image Reconstruction In Photoacoustic Computed Tomography For Breast Imaging, Yang Lou Dec 2017

System Optimization And Iterative Image Reconstruction In Photoacoustic Computed Tomography For Breast Imaging, Yang Lou

McKelvey School of Engineering Theses & Dissertations

Photoacoustic computed tomography(PACT), also known as optoacoustic tomography (OAT), is an emerging imaging technique that has developed rapidly in recent years. The combination of the high optical contrast and the high acoustic resolution of this hybrid imaging technique makes it a promising candidate for human breast imaging, where conventional imaging techniques including X-ray mammography, B-mode ultrasound, and MRI suffer from low contrast, low specificity for certain breast types, and additional risks related to ionizing radiation. Though significant works have been done to push the frontier of PACT breast imaging, it is still challenging to successfully build a PACT breast imaging …


Characterization Of Low Density Intracranial Lesions Using Dual-Energy Computed Tomography, Jessica L. Nute May 2015

Characterization Of Low Density Intracranial Lesions Using Dual-Energy Computed Tomography, Jessica L. Nute

Dissertations & Theses (Open Access)

Calcific and hemorrhagic foci of susceptibility are frequently encountered on routine brain MR studies. Both etiologies cause variations in local magnetic field strength, leading to dark regions on the MR images that cannot be classified. Single-energy CT (SECT) can be used to identify lesions with attenuation over 100 HU as calcific, however lesions with lower attenuation cannot be reliably identified. While calcific lesions are unlikely to cause harm, hemorrhagic lesions carry a risk of subsequent intracranial bleeding; as such, identification of hemorrhage is vital in preventing the inappropriate use of anticoagulant medications in patients with hemorrhagic lesions.

Given there currently …


Advances In Image Acquisition And Filtering For Mri Neuroimaging At 7 Tesla, Andrew T. Curtis Sep 2014

Advances In Image Acquisition And Filtering For Mri Neuroimaging At 7 Tesla, Andrew T. Curtis

Electronic Thesis and Dissertation Repository

Performing magnetic resonance imaging at high magnetic field strength promises many improvements over low fields that are of direct benefit in functional neuroimaging. This includes the possibility of improved signal-to-noise levels, and increased BOLD functional contrast and spatial specificity. However, human MRI at 7T and above suffers from unique engineering challenges that limit the achievable gains. In this thesis, three technological developments are introduced, all of which address separate issues associated with functional magnetic resonance neuroimaging at very high magnetic field strengths.

First, the image homogeneity problem is addressed by investigating methods of RF shimming — modifying the excitation portion …


New Tools For Monitoring Gamma Camera Uniformity, Brad K. Lofton Dec 2010

New Tools For Monitoring Gamma Camera Uniformity, Brad K. Lofton

Dissertations & Theses (Open Access)

Detector uniformity is a fundamental performance characteristic of all modern gamma camera systems, and ensuring a stable, uniform detector response is critical for maintaining clinical images that are free of artifact. For these reasons, the assessment of detector uniformity is one of the most common activities associated with a successful clinical quality assurance program in gamma camera imaging. The evaluation of this parameter, however, is often unclear because it is highly dependent upon acquisition conditions, reviewer expertise, and the application of somewhat arbitrary limits that do not characterize the spatial location of the non-uniformities. Furthermore, as the goal of any …