Full-Text Articles in Engineering Physics

Secondary Electron Yield Of Electron Beam Welded Areas Of Srf Cavities, M. Basovic, S. Popovic, M. Tomovic, L. Vuskovic, A. Samolov, F. Cuckov Jan 2015

Secondary Electron Yield Of Electron Beam Welded Areas Of Srf Cavities, M. Basovic, S. Popovic, M. Tomovic, L. Vuskovic, A. Samolov, F. Cuckov

Physics Faculty Publications

Secondary Electron Emission (SEE) is a phenomenon that contributes to the total electron activity inside the Superconducting Radiofrequency (SRF) cavities during the accelerator operation. SEE is highly dependent on the state of the surface. During electron beam welding process, significant amount of heat is introduced into the material causing the microstructure change of Niobium (Nb). Currently, all simulation codes for field emission and multipacting are treating the inside of the cavity as a uniform, homogeneous surface. Due to its complex shape and fabricating procedure, and the sensitivity of the SEE on the surface state, it would be interesting to see …


Experiment And Results On Plasma Etching Of Srf Cavities, J. Upadhyay, Do Im, J. Peshl, S. Popovic, L. Vuskovic, A. -M. Valente-Feliciano, L. Phillips Jan 2015

Experiment And Results On Plasma Etching Of Srf Cavities, J. Upadhyay, Do Im, J. Peshl, S. Popovic, L. Vuskovic, A. -M. Valente-Feliciano, L. Phillips

Physics Faculty Publications

The inner surfaces of SRF cavities are currently chemically treated (etched or electro polished) to achieve the state of the art RF performance. We designed an apparatus and developed a method for plasma etching of the inner surface for SRF cavities. The process parameters (pressure, power, gas concentration, diameter and shape of the inner electrode, temperature and positive dc bias at inner electrode) are optimized for cylindrical geometry. The etch rate non-uniformity has been overcome by simultaneous translation of the gas point-of-entry and the inner electrode during the processing. A single cell SRF cavity has been centrifugally barrel polished, chemically …


Decrease Of The Surface Resistance In Superconducting Niobium Resonator Cavities By The Microwave Field, G. Ciovati, P. Dhakal, A. Gurevich Jan 2014

Decrease Of The Surface Resistance In Superconducting Niobium Resonator Cavities By The Microwave Field, G. Ciovati, P. Dhakal, A. Gurevich

Physics Faculty Publications

Measurements of the quality factor, Q, of Nb superconducting microwave resonators often show that Q increases by ≃10%–30% with increasing radio-frequency (rf) field, H, up to ∼15–20 mT. Recent high temperature heat treatments can amplify this rf field-induced increase of Q up to ≃50%–100% and extend it to much higher fields ≃100 mT, but the mechanisms of the enhancement of Q(H) remain unclear. Here, we suggest a method to reveal these mechanisms by measuring temperature dependencies of Q at different rf field amplitudes. We show that the increase of Q(H) does not …


Improved Oxygen Diffusion Model To Explain The Effect Of Low-Temperature Baking On High Field Losses In Niobium Superconducting Cavities, Gianluigi Ciovati Jan 2006

Improved Oxygen Diffusion Model To Explain The Effect Of Low-Temperature Baking On High Field Losses In Niobium Superconducting Cavities, Gianluigi Ciovati

Physics Faculty Publications

Radio-frequency (rf) superconducting cavities made of high purity niobium are widely used to accelerate charged particle beams in particle accelerators. The major limitation to achieve rf field values approaching the theoretical limit for niobium is represented by “anomalous” losses which degrade the quality factor of the cavities starting at peak surface magnetic fields of about 100mT, in the absence of field emission. These high field losses are often referred to as Q drop. It has been observed that the Q drop is drastically reduced by baking the cavities at 120°C for about 48h under ultrahigh vacuum. An improved oxygen diffusion …


Measurement Of The High-Field Q Drop In The Tm₀₁₀ And Te₀₁₁ Modes In A Niobium Cavity, Gianluigi Ciovati, Peter Kneisel Jan 2006

Measurement Of The High-Field Q Drop In The Tm₀₁₀ And Te₀₁₁ Modes In A Niobium Cavity, Gianluigi Ciovati, Peter Kneisel

Physics Faculty Publications

In the last few years superconducting radio-frequency (rf) cavities made of high-purity (residual resistivity ratio >200) niobium achieved accelerating gradients close to the theoretical limits. An obstacle towards achieving reproducibly higher fields is represented by “anomalous” losses causing a sharp degradation of the cavity quality factor when the peak surface magnetic field (Bp) is above about 90 mT, in the absence of field emission. This effect, called “Q drop” has been measured in many laboratories with single- and multicell cavities mainly in the gigahertz range. In addition, a low-temperature (100–140 °C) “in situ” baking of the cavity was found …


Surface Resistance Measurements Of Superconducting Niobium Samples With A Triaxial Cavity, Paul Martin Boccard Jan 1999

Surface Resistance Measurements Of Superconducting Niobium Samples With A Triaxial Cavity, Paul Martin Boccard

Physics Theses & Dissertations

This experimental study has revealed and investigated many of the physical issues that affect accurate measurement of the surface resistance for small samples consisting of superconducting niobium films on copper substrates. It is believed that this work provides the groundwork for future research directed towards solving this important problem. Accurate measurement of surface resistance for such samples is needed to allow the rapid evaluation and optimization of the deposition parameters necessary for manufacturing low-loss superconducting niobium films.

A superconducting niobium triaxial cavity was investigated to determine its suitability for measuring the residual surface resistance of copper samples that were sputter-coated …