Full-Text Articles in Physics
Thermal Lattice Boltzmann Simulation For Multispecies Fluid Equilibration, Linda L. Vahala, Darren Wah, George Vahala, Jonathan Carter, Pavol Pavlo
Thermal Lattice Boltzmann Simulation For Multispecies Fluid Equilibration, Linda L. Vahala, Darren Wah, George Vahala, Jonathan Carter, Pavol Pavlo
Electrical & Computer Engineering Faculty Publications
The equilibration rate for multispecies fluids is examined using thermal lattice Boltzmann simulations. Two-dimensional free-decay simulations are performed for effects of velocity shear layer turbulence on sharp temperature profiles. In particular, parameters are so chosen that the lighter species is turbulent while the heavier species is laminar-and so its vorticity layers would simply decay and diffuse in time. With species coupling, however, there is velocity equilibration followed by the final relaxation to one large co- and one large counter-rotating vortex. The temperature equilibration proceeds on a slower time scale and is in good agreement with the theoretical order of magnitude …
Resolution Of Overlapping Spectra By Wavelength Modulation Spectroscopy, Audra Michiele Bullock
Resolution Of Overlapping Spectra By Wavelength Modulation Spectroscopy, Audra Michiele Bullock
Electrical & Computer Engineering Theses & Dissertations
Wavelength modulation absorption spectroscopy is a highly sensitive, non-intrusive technique for probing gaseous species, which employs the well-known principles of modulation spectroscopy in a novel way. With this technique, parameters such as velocity, density, and temperature can be measured with a high degree of precision. The research presented here shows that wavelength modulation is a convenient means of increasing the sensitivity of an absorption spectroscopy measurement because it allows for harmonic detection. The focus of the dissertation is resolution of overlapping spectra by harmonic detection and the advantages gained by performing detection at the higher harmonics, e.g., sixth and eighth. …
Series Operation Of Direct Current Xenon Chloride Excimer Sources, Ahmed El-Habachi, Wenhui Shi, Mohamed Moselhy, Robert H. Stark, Karl H. Schoenbach
Series Operation Of Direct Current Xenon Chloride Excimer Sources, Ahmed El-Habachi, Wenhui Shi, Mohamed Moselhy, Robert H. Stark, Karl H. Schoenbach
Bioelectrics Publications
Stable, direct current microhollow cathode discharges in mixtures of hydrochloric acid, hydrogen, xenon, and neon have been generated in a pressure range of 200–1150 Torr. The cathode hole diameter was 250 μm. Sustaining voltages range from 180 to 250 V at current levels of up to 5 mA. The discharges are strong sources of xenon chloride excimer emission at a wavelength of 308 nm. Internal efficiencies of approximately 3% have been reached at a pressure of 1050 Torr. The spectral radiant power at this pressure was measured as 5 mW/nm at 308 nm for a 3 mA discharge. By using …