Open Access. Powered by Scholars. Published by Universities.®

Instrumentation Commons™

Open Access. Powered by Scholars. Published by Universities.®

Physics

Institution
Keyword
Publication Year
Publication
Publication Type

Articles 61 - 64 of 64

Full-Text Articles in Instrumentation

The Cosmic Ray Observatory Project: A Statewide Outreach And Education Ex-Periment In Nebraska, Daniel Claes, Gregory Snow Jul 2007

The Cosmic Ray Observatory Project: A Statewide Outreach And Education Ex-Periment In Nebraska, Daniel Claes, Gregory Snow

Gregory Snow Publications

Abstract: The Cosmic Ray Observatory Project (CROP) is a statewide education and research ex-periment involving Nebraska high school students, teachers and university undergraduates in the study of extensive cosmic-ray air showers. A network of high school teams construct, install, and op-erate school-based detectors in coordination with University of Nebraska physics professors and graduate students. The detector system at each school is an array of scintillation counters recycled from the Chicago Air Shower Array in weather-proof enclosures on the school roof, with a GPS re-ceiver providing a time stamp for cosmic-ray events. The detectors are connected to triggering elec-tronics and a …


Trace Analysis Of Organic Substances, Alan Giltinan Jan 2003

Trace Analysis Of Organic Substances, Alan Giltinan

Theses

One of the major challenges facing the pharmaceutical industry is the control of the amount of trace contaminants during the manufacture of organic substances. Lowering the level of contamination improves the quality of the product and reduces possible side effects.

One of the main techniques used to detect trace contaminants is UV-VIS spectroscopy, where the unique absorption fingerprint of a chemical reveals its presence. UV-VIS absorption is based upon the Beer-Lambert Law. The critical point to note about this law is that the absorption is exponentially dependent on both the concentration of the absorber and the pathlength traversed by the …


Temperature Dependence Of Stark Width Of The 463.054 Nm Nii Spectral Line, Vladimir Milosavljevic, Ruzica Konjevic, Stevan Djenize Mar 1999

Temperature Dependence Of Stark Width Of The 463.054 Nm Nii Spectral Line, Vladimir Milosavljevic, Ruzica Konjevic, Stevan Djenize

Articles

Stark width of the 463.054 nm singly ionized nitrogen spectral line, that belong to transition, have been measured in a linear pulsed, low pressure, arc discharge. The working gas was helium-nitrogen-oxygen mixture. Electron densities of 0.751023 to 1.451023 were determined in the electron temperature range between 30000 K - 38000 K. The measured values have been compared with our calculated data, using the modified semiempirical approximation. On the basis of the agreement among experimental and theoretical Stark width data, the isolated 463.054 nm NII spectral line can be recommended as convenient spectral line for plasma diagnostics.


Aliasing Reduction In Staring Infrared Imagers Utilizing Subpixel Techniques, Joseph C. Gillette, Thomas M. Stadtmiller, Russell C. Hardie Nov 1995

Aliasing Reduction In Staring Infrared Imagers Utilizing Subpixel Techniques, Joseph C. Gillette, Thomas M. Stadtmiller, Russell C. Hardie

Electrical and Computer Engineering Faculty Publications

We introduce and analyze techniques for the reduction of aliased signal energy in a staring infrared imaging system. A standard staring system uses a fixed two-dimensional detector array that corresponds to a fixed spatial sampling frequency determined by the detector pitch or spacing. Aliasing will occur when sampling a scene containing spatial frequencies exceeding half the sampling frequency. This aliasing can significantly degrade the image quality. The aliasing reduction schemes presented here, referred to as microscanning, exploit subpixel shifts between time frames of an image sequence. These multiple images are used to reconstruct a single frame with reduced aliasing. If …