Open Access. Powered by Scholars. Published by Universities.®
- Discipline
- Keyword
-
- Prostate cancer (2)
- Treatment planning (2)
- VMAT (2)
- Air gap (1)
- Bellyboard (1)
-
- Bolus (1)
- CTV (1)
- Chest wall (1)
- Communication Errors (1)
- Dosimetric comparison (1)
- Emergency Department (1)
- Flattening filter free (1)
- Halcyon (1)
- Handover (1)
- High-risk prostate cancer (1)
- Hypofractionated (1)
- Interventional Radiology (1)
- Jaw Tracking (1)
- Knowledge based planning software (1)
- Margins (1)
- Medical Dosimetry (1)
- PTV (1)
- Pancreatic cancer (1)
- Pancreatic treatment (1)
- Planning techniques (1)
- Prone breast irradiation (1)
- Quality Improvement (1)
- Radiation (1)
- Radiation Oncology (1)
- Radiation Therapy (1)
- Publication
Articles 1 - 9 of 9
Full-Text Articles in Radiology
A Dosimetric Comparison Of Halcyon 6x-Fff And Truebeam 6x In Prone Left Whole Breast Radiation Therapy, Maritza Soto, Kelly Labant, M.S., Cmd, Rt(T), Kristen Vu, M.S., Cmd, Rt(T)
A Dosimetric Comparison Of Halcyon 6x-Fff And Truebeam 6x In Prone Left Whole Breast Radiation Therapy, Maritza Soto, Kelly Labant, M.S., Cmd, Rt(T), Kristen Vu, M.S., Cmd, Rt(T)
Masters Projects
Purpose:
This retrospective study compared dosimetric differences between prone left whole breast radiation (WBRT) treatment plans originally generated for Halcyon using 6X flattening- filter-free (FFF) beams and replanned for a conventional TrueBeam using 6X beams.
Methods:
Ten prone whole left breast treatment plans were paired and retrospectively analyzed. Clinically treated Halcyon 6X flattening filter free plans were replanned on TrueBeam using flattened 6X beams in Eclipse v16.1. Contours for all plans were generated using artificial intelligence-based autosegmentation, reviewed by a medical dosimetrist and radiation oncologist, and forward planned with a tangent technique in EZFluence to achieve identical planning objectives. Dose …
A Dosimetric Comparison Of Treatment Techniques For Stereotactic Body Radiotherapy For Pancreatic Patients, Kameron Lemley
A Dosimetric Comparison Of Treatment Techniques For Stereotactic Body Radiotherapy For Pancreatic Patients, Kameron Lemley
Masters Projects
Stereotactic body radiotherapy (SBRT) is utilized in radiation therapy to deliver ablative radiation doses to tumor volumes while achieving high conformity and minimal dose to surrounding critical structures. This treatment technique allows for faster dose fall-off which allows tighter treatment margins. SBRT for pancreatic cancer has been investigated for its efficacy and has proven to be an effective treatment choice for neoadjuvant radiation therapy. Since pancreatic cancer is extremely aggressive with a high mortality rate, it is important to have a treatment option that can reduce cost and increase convenience for the patient while simultaneously providing a conformal treatment plan. …
Improving Handover Process For Stroke Patients Transferring From Emergency Department To Interventional Radiology: A Quality Improvement Project, Megan Buchman
Doctoral Projects
Background: A standardized handover process is needed for stroke patients transferring from the Emergency Department to Interventional Radiology.
Local Problem: Emergency Department and Interventional Radiology had different handover processes.
Methods: A quality improvement project was conducted in a large Magnet® designated midwestern health system. Participants included emergency department and interventional radiology nurses and stroke patients. Pre/post-quality and post implementation measures were obtained.
Interventions: The interventions included utilizing a standardized handover tool between departments, calling report prior to patient transfer, and turning in handover tool following stroke case to ensure compliance. Two cycles of the Plan-Do-Study-Act Cycle were completed.
Results: No …
A Comparison Between Rectal Dose In Prostate Radiotherapy Patients Treated With Spaceoar Hydrogel Present Versus Patients Treated Without Spaceoar Hydrogel., David Desano
Masters Projects
Introduction: External beam radiation therapy is a common treatment option for prostate cancer patients with localized disease. Radiation-induced side effects associated with the rectum can impact a patient’s ability to complete treatment or affect the quality of life years after radiation treatment. Spaceoar hydrogel has been developed to reduce radiation dose to nearby pelvis structures, and therefore decreasing potential side effects.
Methods: A total of 20 patients who received definitive radiation therapy to the prostate and seminal vesicles were selected and placed into 2 groups (10 spaceoar, 10 non-spaceoar). The individuals’ age ranged from 60 to 79 years old with …
Dosimetric Comparison Of Hypofractionated Prostate Radiation With Simultaneous Integrated Boost And Conventional Fractionation With Sequential Boost, Kristina Sammon
Dosimetric Comparison Of Hypofractionated Prostate Radiation With Simultaneous Integrated Boost And Conventional Fractionation With Sequential Boost, Kristina Sammon
Masters Projects
Introduction: Hypofractionated treatment delivery regimens are associated with better overall long-term disease control for prostate cancer. For patients with high-risk disease, there may be an indication for treatment of the surrounding pelvic lymph nodes for better over-all disease control. In order to achieve a hypofractionated regimen with treatment to the surrounding pelvic lymph nodes a simultaneous integrated boost technique is employed. There are concerns regarding achievability of target dose coverage and limitation of dose to the surrounding organs at risk with this fractionation.
Methods: This study is a retrospective dosimetric analysis of 7 randomly selected patients with high-risk prostate cancer. …
Dosimetric Effect When Treating Multiple Lesion Srs Using Vmat With And Without Jaw Tracking, Mindy Bui
Dosimetric Effect When Treating Multiple Lesion Srs Using Vmat With And Without Jaw Tracking, Mindy Bui
Masters Projects
The main purpose of this study was to determine if jaw tracking or non-jaw tracking is the superior technique for patients with multiple brain metastasis that are treated with Volumetric Modulated Radiation Therapy (VMAT) Stereotactic Radiosurgery (SRS). Doses to the organs at risk (OAR) and the target volumes were analyzed using the dose volume histogram (DVH) and dose statistics for each plan. The goal of this study included analyzing the dosimetric effect on the organs at risk and the normal tissue when using jaw tracking versus non jaw tracking. The pros and cons for each technique were identified as well …
The Air Gap Effect Between A Bolus And The Skin Surface For Chest Wall Irradiation, Marisa Clark
The Air Gap Effect Between A Bolus And The Skin Surface For Chest Wall Irradiation, Marisa Clark
Masters Projects
Planning technique and bolus choice are important aspects in planning chest wall irradiation (CWI). Many previous studies have tested various combinations of photon energies, electron energies, bolus types and sizes, air gaps sizes, and treatment methods. This study aims to assess the effect of smaller, clinically relevant air gap sizes on specific chest wall treatments using a variety of common bolus types. Due to the Covid-19 pandemic, no data was able to be collected and was instead fabricated by the researcher. Four different treatment plans were created on a phantom patient using various energies of photons (6MV and 10MV) and …
Analysis Of Ptv Margins For Vmat Treatment Of Rectal Cancers Utilizing Prone Bellyboard Device., Ben Armbuster
Analysis Of Ptv Margins For Vmat Treatment Of Rectal Cancers Utilizing Prone Bellyboard Device., Ben Armbuster
Masters Projects
Utilization of a bellyboard device reduces small bowel dose for patients receiving radiation therapy for rectal cancer. The reduction of small bowel dose with the bellyboard is even more significant in intensity modulated radiation therapy rectal treatments, as opposed to conventional 3D treatments. However, there is evidence of increased setup variation with prone bellyboard positioning, especially in pitch and roll. The purpose of this study is to determine the margin needed between the clinical target volume and the planning target volume to adequately account for these setup variations when planning volumetric modulated arc therapy rectal cases utilizing the bellyboard device. …
A Multiple Comparison Study That Test The Validity Of Varian’S Rapidplan For Prostate Cancer Cases Based On Models Built From Outside Institution., La'rone Reid
Masters Projects
In radiation oncology treatment planning techniques and outcomes can differ from one institution to the next. With knowledge-based planning (KBP) the experience of larger institutions could help smaller institutions who may not have the opportunity to encounter certain types of cancer cases. However, this scenario is only true if the KBP software is consistent with its algorithmic output. Varian's KBP software called Rapid Plan (RP) will be analyzed for algorithmic consistency. This study investigates the validity and consistency of RP models from two different radiation oncology institutions, and compare data to determine RP quality, and consistency when planning prostate cancer …