Open Access. Powered by Scholars. Published by Universities.®

Radiation Medicine Commons™

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 17 of 17

Full-Text Articles in Radiation Medicine

Reirradiation Treatment Effects In The Clinic (Retec) Proposal - Proof Of Concept Based On Spinal Cord Dose Tolerance For Reirradiation With Stereotactic Body Radiotherapy, Jimm Grimm, Anand Mahadevan, Olusola Obayomi-Davies, Scott G. Soltys, Arjun Sahgal, Kristin J. Redmond, Michael T. Milano, Wolfgang A. Tomé, Kenneth Brooks, Scott Dodd, John Austin Vargo, Gopal Subedi, Jinyu Xue, Bisher Ebid, Felix Ehret, Byung-Han Andrew Rhieu, Christoph Fürweger, Rachel Grimm, Alexander Muacevic, Vitali Moiseenko, Shalom Kalnicki, Mark Mclaughlin, Lawrence R. Kleinberg, John R. Adler, Iris C. Gibbs Apr 2026

Reirradiation Treatment Effects In The Clinic (Retec) Proposal - Proof Of Concept Based On Spinal Cord Dose Tolerance For Reirradiation With Stereotactic Body Radiotherapy, Jimm Grimm, Anand Mahadevan, Olusola Obayomi-Davies, Scott G. Soltys, Arjun Sahgal, Kristin J. Redmond, Michael T. Milano, Wolfgang A. Tomé, Kenneth Brooks, Scott Dodd, John Austin Vargo, Gopal Subedi, Jinyu Xue, Bisher Ebid, Felix Ehret, Byung-Han Andrew Rhieu, Christoph Fürweger, Rachel Grimm, Alexander Muacevic, Vitali Moiseenko, Shalom Kalnicki, Mark Mclaughlin, Lawrence R. Kleinberg, John R. Adler, Iris C. Gibbs

College of Health Professions Faculty Papers

BACKGROUND: Since the inception of spinal radiosurgery decades ago, the factors influencing spinal cord recovery have remained unclear. Elucidating these factors would aid in reirradiation planning and delivery. We describe modeling reirradiation normal tissue complication probabilities (NTCP) from compiled published data, akin to the collaborative Quantitative Analysis of Normal Tissue Effects in the Clinic (QUANTEC) and High Dose per Fraction, Hypofractionated Treatment Effects in the Clinic (HyTEC) projects.

PURPOSE: Simple dose-time recovery factors for the spinal cord serve as a basis to propose the Reirradiation Treatment Effects in the Clinic (ReTEC) project. ReTEC aims to define human organ recovery factors …


Computed Tomography For Four-Dimensional Dose Calculation: Effect Of Detector Array Length, Inhwan Yeo, Qianyi Xu Apr 2026

Computed Tomography For Four-Dimensional Dose Calculation: Effect Of Detector Array Length, Inhwan Yeo, Qianyi Xu

Department of Radiation Oncology Faculty Papers

PURPOSE: Four-dimensional computed tomography (4DCT) is susceptible to a geometrical error when respiration changes upon patient shift. 4DCT using 16-cm detector arrays, not needing the shift, has been shown to improve geometrical accuracy, compared with a conventional 4DCT (4-cm array), albeit with some Hounsfield unit discrepancies. The 4DCTs were validated for 4D planning.

MATERIALS AND METHODS: A lung-mimicking phantom containing a spherical target with ten respiratory traces and three tumor-shaped targets with their traces was respectively imaged when, to each of the ten-positions/phases, the lung was moved (1) step-wisely by helical scan at each movement (ground truth; 4DCTGT), …


Evaluation Of The Intempo Path Set For Cyberknife Prostate And Lung Sbrt: A Single-Institution Experience, Yingcui Jia, Lei Fu, Shari Rudoler, Eric Gressen, Yevgeniy Vinogradskiy, Qianyi Xu Feb 2026

Evaluation Of The Intempo Path Set For Cyberknife Prostate And Lung Sbrt: A Single-Institution Experience, Yingcui Jia, Lei Fu, Shari Rudoler, Eric Gressen, Yevgeniy Vinogradskiy, Qianyi Xu

Department of Radiation Oncology Faculty Papers

PURPOSE: The InTempo adaptive imaging system is an important component of the Accuray CyberKnife System, designed to enhance the system's ability to track and correct tumor motion during treatment. However, a limitation of this feature is the reduction of available nodes for treatment planning. The impact of a reduced number of nodes on the quality of InTempo-based treatment plans has not previously been evaluated. This retrospective study aims to compare the dosimetry of CyberKnife plans with and without The InTempo path set for both prostate and lung stereotactic body radiotherapy (SBRT).

METHODS: This study included twelve consecutive prostate SBRT patients …


A Feasibility Study Of Sexual Organ-Dose Sparing Volumetric Modulated Arc Therapy In Female Low Rectal Cancer Patients Treated With Three-Dimensional Conformal Radiation Therapy, Margaret Downes, Victoria Olsen, Andre Williams, Rendi Sheu, Maria Thor, Lucy Greenwald, Vishruta Dumane, Kristin Hsieh, Ayesha Ali, Orly Morgan, Michael Buckstein, Deborah Marshall Dec 2025

A Feasibility Study Of Sexual Organ-Dose Sparing Volumetric Modulated Arc Therapy In Female Low Rectal Cancer Patients Treated With Three-Dimensional Conformal Radiation Therapy, Margaret Downes, Victoria Olsen, Andre Williams, Rendi Sheu, Maria Thor, Lucy Greenwald, Vishruta Dumane, Kristin Hsieh, Ayesha Ali, Orly Morgan, Michael Buckstein, Deborah Marshall

Department of Radiation Oncology Faculty Papers

BACKGROUND: Sexual dysfunction is a significant toxicity of pelvic radiation therapy (RT) for female rectal cancer patients and may be more common with intensity-modulated techniques compared to three-dimensional conformal radiation therapy (3D-CRT). However, limited research has evaluated dose sparing of female sexual organs at risk (OARs), particularly erectile tissues that are critical for sexual function.

PURPOSE: This feasibility study aimed to demonstrate the practicality of contouring and sparing female sexual OARs in rectal cancer RT by generating sexual organ-sparing volumetric modulated arc therapy (SO-VMAT) plans from a small 3D-CRT cohort and comparing dose distributions to guide future planning.

METHODS: Nine …


From Standard To Stratified: Modeling Ntcp And Ear To Personalize Daily Mv-Cbct In Radiotherapy., Duong Thanh Tai, Luong Tien Phat, Tran Trung Kien, Duong Tuan Linh, Nguyen Ngoc Anh, Nguyen Quang Hung, Peter Sandwall, Parham Alaei, David Bradley, James C L Chow Dec 2025

From Standard To Stratified: Modeling Ntcp And Ear To Personalize Daily Mv-Cbct In Radiotherapy., Duong Thanh Tai, Luong Tien Phat, Tran Trung Kien, Duong Tuan Linh, Nguyen Ngoc Anh, Nguyen Quang Hung, Peter Sandwall, Parham Alaei, David Bradley, James C L Chow

Oncology Articles

PURPOSE: To evaluate the cumulative radiobiological impact of daily megavoltage cone-beam computed tomography (MV-CBCT) imaging dose based on normal tissue complication probability (NTCP) and excess absolute risk (EAR) of secondary malignancies among radiotherapy patients treated for breast, pelvic, and head & neck cancers. This study investigated whether MV-CBCT imaging dose warrants protocol personalization according to patient age, anatomical treatment site, and organ-specific radiosensitivity.

METHODS: This retrospective study included cohorts of breast (n = 30), pelvic (n = 17), and head & neck (n = 20) cancer patients undergoing radiotherapy with daily MV-CBCT. Imaging dose distributions employing two common MV-CBCT protocols …


Fast And Accurate Measurement Of Small Field Dosimetry Using A Novel Scintillation Detector, Yiding Han, Jingzhu Xu, Yao Hao, Baozhou Sun Dec 2025

Fast And Accurate Measurement Of Small Field Dosimetry Using A Novel Scintillation Detector, Yiding Han, Jingzhu Xu, Yao Hao, Baozhou Sun

Faculty, Staff and Students Publications

Background: The most used instruments for small-field dosimetry have notable limitations, including the need for correction of output factors, limited scanning speeds, and challenges in alignment for percentage depth dose (PDD) measurements, particularly for extremely small fields. However, plastic scintillation detectors (PSDs) are an attractive alternative for small-field dosimetry due to their correction-free nature, linear dose response, and fast response time.

Purpose: This study evaluates the robustness and accuracy of the dosimetric measurements using a new water-equivalent PSD in small-field dosimetry. The study also aims to report accurate measurements of output factors, profiles, and an indirect method for measuring PDD …


Investigating The Necessity Of Adaptive Radiotherapy In Tomotherapy Of Head And Neck Cancer Patients, Ali Chaparian, Mahsa Kianinia, Mahnaz Roayaei, Nadia Najafizade, Abolfazl Kanani, Leili Mahani, Hamidreza Nourzadeh Jul 2025

Investigating The Necessity Of Adaptive Radiotherapy In Tomotherapy Of Head And Neck Cancer Patients, Ali Chaparian, Mahsa Kianinia, Mahnaz Roayaei, Nadia Najafizade, Abolfazl Kanani, Leili Mahani, Hamidreza Nourzadeh

Department of Radiation Oncology Faculty Papers

BACKGROUND: Anatomical variations that occur during radiation therapy in head and neck cancer (HNC) patients can lead to significant dosimetric changes. The purpose of this study is to evaluate dosimetric and volume changes in key anatomical structures for different treatment sites in HNC patients, and to determine the percentage of patients who need adaptive radiotherapy (ART) per treatment site.

METHODS: A total of 1,740 megavoltage computed tomography (MVCT) images from 58 HNC patients treated with helical tomotherapy (HT) were exported to the PreciseART™ (Accuray) software. Volume changes in the planning target volume (PTV) and the organs at risk (OARs) in …


Evaluating Artifact-Free Four-Dimensional Computer Tomography With 16 Cm Detector Array, Inhwan Yeo, Wei Nie, Jiajin Fan, Mindy Joo, Michael Correa, Qianyi Xu Apr 2025

Evaluating Artifact-Free Four-Dimensional Computer Tomography With 16 Cm Detector Array, Inhwan Yeo, Wei Nie, Jiajin Fan, Mindy Joo, Michael Correa, Qianyi Xu

Department of Radiation Oncology Faculty Papers

PURPOSE: To evaluate a 16 cm-array axial four-dimensional computer tomography (4DCT) in comparison with a 4 cm-array 4DCT in the presence of respiration irregularity.

METHOD: Ten traces of lung tumor motion from CyberKnife treatments were imported to move the lung cylinder, containing a spherical target, of a phantom. Images were acquired for the lung that moved to each of the 10-positions/phases (1) step-wisely by nominal helical scan at each movement (ground truth), (2) continuously by 4D scan with the 16 cm array, and (3) the same with the 4 cm array, involving table shift. Irregularities, consisting of baseline shift and/or …


Multi-Institution Single Geometry Plan Complexity Characteristics Based On Iroc Phantoms, Vimal Desai, Zacariah Labby, Wesley Culberson, Larry Dewerd, Stephen Kry Apr 2024

Multi-Institution Single Geometry Plan Complexity Characteristics Based On Iroc Phantoms, Vimal Desai, Zacariah Labby, Wesley Culberson, Larry Dewerd, Stephen Kry

Department of Radiation Oncology Faculty Papers

BACKGROUND: Clinical intensity modulated radiation therapy plans have been described using various complexity metrics to help identify problematic radiotherapy plans. Most previous studies related to the quantification of plan complexity and their utility have relied on institution-specific plans which can be highly variable depending on the machines, planning techniques, delivery modalities, and measurement devices used. In this work, 1723 plans treating one of only four standardized geometries were simultaneously analyzed to investigate how radiation plan complexity metrics vary across four different sets of common objectives.

PURPOSE: To assess the treatment plan complexity characteristics of plans developed for Imaging and Radiation …


Real World Clinical Experience Using Daily Intelligence-Assisted Online Adaptive Radiotherapy For Head And Neck Cancer, Philip Blumenfeld, Eduard Arbit, Robert Den, Ayman Salhab, Tal Falick Michaeli, Marc Wygoda, Yair Hillman, Raphael Pfeffer, Marcel Fang, Yael Misrati, Noam Weizman, Jon Feldman, Aron Popovtzer Mar 2024

Real World Clinical Experience Using Daily Intelligence-Assisted Online Adaptive Radiotherapy For Head And Neck Cancer, Philip Blumenfeld, Eduard Arbit, Robert Den, Ayman Salhab, Tal Falick Michaeli, Marc Wygoda, Yair Hillman, Raphael Pfeffer, Marcel Fang, Yael Misrati, Noam Weizman, Jon Feldman, Aron Popovtzer

Department of Radiation Oncology Faculty Papers

Background

Adaptive radiation therapy (ART) offers a dynamic approach to address structural and spatial changes that occur during radiotherapy (RT) for locally advanced head and neck cancers. The integration of daily ART with Cone-Beam CT (CBCT) imaging presents a solution to enhance the therapeutic ratio by addressing inter-fractional changes.

Methods

We evaluated the initial clinical experience of daily ART for patients with head and neck cancer using an online adaptive platform with intelligence-assisted workflows on daily CBCT. Treatment included auto-contour and structure deformation of Organs at Risk (OARs) and target structures, with adjustments by the treating physician. Two plans were …


Efficacy Of Scalp-Sparing Volumetric-Modulated Arc Therapy Approach In Reducing Scalp Radiation Dose For Patients With Glioblastoma: A Cross-Sectional Study, Muneeb Khan Niazi, Olga Russial, Louis Cappelli, Ryan Miller, Yingxuan Chen, Yelena Vakhnenko, Haisong Lui, Wenyin Shi Aug 2023

Efficacy Of Scalp-Sparing Volumetric-Modulated Arc Therapy Approach In Reducing Scalp Radiation Dose For Patients With Glioblastoma: A Cross-Sectional Study, Muneeb Khan Niazi, Olga Russial, Louis Cappelli, Ryan Miller, Yingxuan Chen, Yelena Vakhnenko, Haisong Lui, Wenyin Shi

Department of Radiation Oncology Faculty Papers

BACKGROUND: Radiation is integral to the treatment of glioblastoma (GBM). However, radiation-induced scalp toxicity can negatively impact patients' quality of life. Volumetric modulated arc therapy (VMAT) optimizes the dose to organs at risk (OARs). We hypothesize that a scalp-sparing VMAT (SSV) approach can significantly reduce undesirable doses to the scalp without compromising the target dose.

METHODS: This is a retrospective cross-sectional study of GBM patients who originally received radiation with non-SSV. We contoured the scalp as a 5 mm rind-like structure beneath the skin above the level of the foramen magnum. We replanned our patients using SSV techniques. We compared …


Characterizing The Interplay Of Treatment Parameters And Complexity And Their Impact On Performance On An Iroc Imrt Phantom Using Machine Learning, Hunter Mehrens, Andrea Molineu, Nadia Hernandez, Laurence Court, Rebecca Howell, David Jaffray, Christine B Peterson, Julianne Pollard-Larkin, Stephen F Kry May 2023

Characterizing The Interplay Of Treatment Parameters And Complexity And Their Impact On Performance On An Iroc Imrt Phantom Using Machine Learning, Hunter Mehrens, Andrea Molineu, Nadia Hernandez, Laurence Court, Rebecca Howell, David Jaffray, Christine B Peterson, Julianne Pollard-Larkin, Stephen F Kry

Faculty, Staff and Student Publications

AIM OF THE STUDY: To elucidate the important factors and their interplay that drive performance on IMRT phantoms from the Imaging and Radiation Oncology Core (IROC).

METHODS: IROC's IMRT head and neck phantom contains two targets and an organ at risk. Point and 2D dose are measured by TLDs and film, respectively. 1,542 irradiations between 2012-2020 were retrospectively analyzed based on output parameters, complexity metrics, and treatment parameters. Univariate analysis compared parameters based on pass/fail, and random forest modeling was used to predict output parameters and determine the underlying importance of the variables.

RESULTS: The average phantom pass rate was …


Deep Learning-Based Dose Prediction For Automated, Individualized Quality Assurance Of Head And Neck Radiation Therapy Plans, Mary P Gronberg, Beth M Beadle, Adam S Garden, Heath Skinner, Skylar Gay, Tucker Netherton, Wenhua Cao, Carlos E Cardenas, Christine Chung, David T Fuentes, Clifton D Fuller, Rebecca M Howell, Anuja Jhingran, Tze Yee Lim, Barbara Marquez, Raymond Mumme, Adenike M Olanrewaju, Christine B Peterson, Ivan Vazquez, Thomas J Whitaker, Zachary Wooten, Ming Yang, Laurence E Court Jan 2023

Deep Learning-Based Dose Prediction For Automated, Individualized Quality Assurance Of Head And Neck Radiation Therapy Plans, Mary P Gronberg, Beth M Beadle, Adam S Garden, Heath Skinner, Skylar Gay, Tucker Netherton, Wenhua Cao, Carlos E Cardenas, Christine Chung, David T Fuentes, Clifton D Fuller, Rebecca M Howell, Anuja Jhingran, Tze Yee Lim, Barbara Marquez, Raymond Mumme, Adenike M Olanrewaju, Christine B Peterson, Ivan Vazquez, Thomas J Whitaker, Zachary Wooten, Ming Yang, Laurence E Court

Faculty, Staff and Student Publications

PURPOSE: This study aimed to use deep learning-based dose prediction to assess head and neck (HN) plan quality and identify suboptimal plans.

METHODS AND MATERIALS: A total of 245 volumetric modulated arc therapy HN plans were created using RapidPlan knowledge-based planning (KBP). A subset of 112 high-quality plans was selected under the supervision of an HN radiation oncologist. We trained a 3D Dense Dilated U-Net architecture to predict 3-dimensional dose distributions using 3-fold cross-validation on 90 plans. Model inputs included computed tomography images, target prescriptions, and contours for targets and organs at risk (OARs). The model's performance was assessed on …


Fast Generation Of Lung Sbrt Plans With A Knowledge-Based Planning Model On Ring-Mounted Halcyon Linac, Justin Visak, Aaron Webster, Mark E. Bernard, Mahesh R. Kudrimoti, Marcus E. Randall, Ronald C. Mcgarry, Damodar Pokhrel Sep 2021

Fast Generation Of Lung Sbrt Plans With A Knowledge-Based Planning Model On Ring-Mounted Halcyon Linac, Justin Visak, Aaron Webster, Mark E. Bernard, Mahesh R. Kudrimoti, Marcus E. Randall, Ronald C. Mcgarry, Damodar Pokhrel

Radiation Medicine Faculty Publications

PURPOSE: To demonstrate fast treatment planning feasibility of stereotactic body radiation therapy (SBRT) for centrally located lung tumors on Halcyon Linac via a previously validated knowledge-based planning (KBP) model to support offline adaptive radiotherapy.

MATERIALS/METHODS: Twenty previously treated non-coplanar volumetric-modulated arc therapy (VMAT) lung SBRT plans (c-Truebeam) on SBRT-dedicated C-arm Truebeam Linac were selected. Patients received 50 Gy in five fractions. c-Truebeam plans were re-optimized for Halcyon manually (m-Halcyon) and with KBP model (k-Halcyon). Both m-Halcyon and k-Halcyon plans were normalized for identical or better target coverage than clinical c-Truebeam …


Predicting The Effect Of Indirect Cell Kill In The Treatment Of Multiple Brain Metastases Via Single-Isocenter/Multitarget Volumetric Modulated Arc Therapy Stereotactic Radiosurgery, Allison N. Palmiero, Denise Fabian, Marcus E. Randall, William St. Clair, Damodar Pokhrel Sep 2021

Predicting The Effect Of Indirect Cell Kill In The Treatment Of Multiple Brain Metastases Via Single-Isocenter/Multitarget Volumetric Modulated Arc Therapy Stereotactic Radiosurgery, Allison N. Palmiero, Denise Fabian, Marcus E. Randall, William St. Clair, Damodar Pokhrel

Radiation Medicine Faculty Publications

PURPOSE: Due to spatial uncertainty, patient setup errors are of major concern for radiosurgery of multiple brain metastases (m-bm) when using single-isocenter/multitarget (SIMT) volumetric modulated arc therapy (VMAT) techniques. However, recent clinical outcome studies show high rates of tumor local control for SIMT-VMAT. In addition to direct cell kill (DCK), another possible explanation includes the effects of indirect cell kill (ICK) via devascularization for a single dose of 15 Gy or more and by inducing a radiation immune intratumor response. This study quantifies the role of indirect cell death in dosimetric errors as a function of spatial patient setup uncertainty …


Conditional Survival Among Patients With Oropharyngeal Cancer Treated With Radiation Therapy And Alive Without Recurrence 5 Years After Diagnosis, Kristina R Dahlstrom, Juhee Song, Peter F Thall, Clifton D Fuller, Katherine A Hutcheson, Faye M Johnson, G Brandon Gunn, Jack Phan, Steven J Frank, William H Morrison, Renata Ferrarotto, David I Rosenthal, Erich M Sturgis, Adam S Garden Apr 2021

Conditional Survival Among Patients With Oropharyngeal Cancer Treated With Radiation Therapy And Alive Without Recurrence 5 Years After Diagnosis, Kristina R Dahlstrom, Juhee Song, Peter F Thall, Clifton D Fuller, Katherine A Hutcheson, Faye M Johnson, G Brandon Gunn, Jack Phan, Steven J Frank, William H Morrison, Renata Ferrarotto, David I Rosenthal, Erich M Sturgis, Adam S Garden

Faculty, Staff and Students Publications

BACKGROUND: Risk of recurrence among patients with oropharyngeal cancer (OPC) who survive 5 years is low. The goal of this study was to assess long-term survival of patients with OPC alive without recurrence 5 years after diagnosis.

METHODS: This study included newly diagnosed patients with OPC, who had been treated with radiation and were alive without recurrence 5 years after diagnosis. Overall survival (OS) probabilities beyond 5 years were estimated using the Kaplan-Meier method. Factors associated with OS were determined using Bayesian piecewise exponential survival regression. Standardized mortality ratios for all-cause death were estimated controlling for study year, age, and …


A Novel And Clinically Useful Dynamic Conformal Arc (Dca)-Based Vmat Planning Technique For Lung Sbrt, Damodar Pokhrel, Justin Visak, Lana Sanford Jul 2020

A Novel And Clinically Useful Dynamic Conformal Arc (Dca)-Based Vmat Planning Technique For Lung Sbrt, Damodar Pokhrel, Justin Visak, Lana Sanford

Radiation Medicine Faculty Publications

PURPOSE: Volumetric modulated arc therapy (VMAT) is gaining popularity for stereotactic treatment of lung lesions for medically inoperable patients. Due to multiple beamlets in delivery of highly modulated VMAT plans, there are dose delivery uncertainties associated with small-field dosimetry error and interplay effects with small lesions. We describe and compare a clinically useful dynamic conformal arc (DCA)-based VMAT (d-VMAT) technique for lung SBRT using flattening filter free (FFF) beams to minimize these effects.

MATERIALS AND METHODS: Ten solitary early-stage I-II non-small-cell lung cancer (NSCLC) patients were treated with a single dose of 30 Gy using 3-6 non-coplanar VMAT arcs (clinical …