Open Access. Powered by Scholars. Published by Universities.®

Radiation Medicine Commons™

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 14 of 14

Full-Text Articles in Radiation Medicine

Influence Of Background Music On Proton Dose Monitors, Julia Colangeli, Rachel Felder, Nicole Geer, Favour Ihenwe, Shermineh Roodi, Sandra John Baptiste Apr 2026

Influence Of Background Music On Proton Dose Monitors, Julia Colangeli, Rachel Felder, Nicole Geer, Favour Ihenwe, Shermineh Roodi, Sandra John Baptiste

Research Methods Poster Session 2026

This study examines the effects of background music, particularly varying bass frequencies, on dose monitor accuracy in proton therapy using the Hitachi PROBEAT-FR proton accelerator.


Computed Tomography For Four-Dimensional Dose Calculation: Effect Of Detector Array Length, Inhwan Yeo, Qianyi Xu Apr 2026

Computed Tomography For Four-Dimensional Dose Calculation: Effect Of Detector Array Length, Inhwan Yeo, Qianyi Xu

Department of Radiation Oncology Faculty Papers

PURPOSE: Four-dimensional computed tomography (4DCT) is susceptible to a geometrical error when respiration changes upon patient shift. 4DCT using 16-cm detector arrays, not needing the shift, has been shown to improve geometrical accuracy, compared with a conventional 4DCT (4-cm array), albeit with some Hounsfield unit discrepancies. The 4DCTs were validated for 4D planning.

MATERIALS AND METHODS: A lung-mimicking phantom containing a spherical target with ten respiratory traces and three tumor-shaped targets with their traces was respectively imaged when, to each of the ten-positions/phases, the lung was moved (1) step-wisely by helical scan at each movement (ground truth; 4DCTGT), …


High-Density Glass Scintillators For Proton Radiography-Relative Luminosity, Proton Response, And Spatial Resolution, Ethan Stolen, Ryan Fullarton, Rain Hein, Robin L Conner, Luiz G Jacobsohn, Charles-Antoine Collins-Fekete, Sam Beddar, Ugur Akgun, Daniel Robertson Mar 2024

High-Density Glass Scintillators For Proton Radiography-Relative Luminosity, Proton Response, And Spatial Resolution, Ethan Stolen, Ryan Fullarton, Rain Hein, Robin L Conner, Luiz G Jacobsohn, Charles-Antoine Collins-Fekete, Sam Beddar, Ugur Akgun, Daniel Robertson

Faculty, Staff and Student Publications

Proton radiography is a promising development in proton therapy, and researchers are currently exploring optimal detector materials to construct proton radiography detector arrays. High-density glass scintillators may improve integrating-mode proton radiography detectors by increasing spatial resolution and decreasing detector thickness. We evaluated several new scintillators, activated with europium or terbium, with proton response measurements and Monte Carlo simulations, characterizing relative luminosity, ionization quenching, and proton radiograph spatial resolution. We applied a correction based on Birks's analytical model for ionization quenching. The data demonstrate increased relative luminosity with increased activation element concentration, and higher relative luminosity for samples activated with europium. …


Investigate The Delivery Efficiency Improvement For Sparc Compared To Impt, Peilin Liu, B A. De Jong, S Chang, Lewei Zhao, G Liu, Craig Stevens, Rohan Deraniyagala, E W. Korevaar, J A. Langendijk, Xiaoqiang Li, Xuanfeng Ding Jun 2023

Investigate The Delivery Efficiency Improvement For Sparc Compared To Impt, Peilin Liu, B A. De Jong, S Chang, Lewei Zhao, G Liu, Craig Stevens, Rohan Deraniyagala, E W. Korevaar, J A. Langendijk, Xiaoqiang Li, Xuanfeng Ding

Conference Presentation Abstracts

Purpose: To assess the efficiency improvement of SPArc compared to IMPT in proton clinical operation.Methods: A random clinical operation day at a proton therapy center with a two room system. Aa total of 10 Head & Neck cancer cases treated on Jan 6th, 2021were selected and SPArc plans were generated for all the cases with similar target coverage and dose constraints of organ at risk (OARs). 3% range uncertainties and 3mm setup uncertainties were applied for robust optimization. The log files of clinical IMPT were exported to calculate true treatment delivery time. The machine-specific delivery sequence model was utilized to …


Develop A Novel Beam Orientation Optimization Algorithm For Let (Linear Energy Transfer) Incorporated Impt (Intensity Modulated Proton Therapy) (Imptlet, R Dao, Y Qian, Xiaoqiang Li, H Quan, Xuanfeng Ding, G Liu Jun 2023

Develop A Novel Beam Orientation Optimization Algorithm For Let (Linear Energy Transfer) Incorporated Impt (Intensity Modulated Proton Therapy) (Imptlet, R Dao, Y Qian, Xiaoqiang Li, H Quan, Xuanfeng Ding, G Liu

Conference Presentation Abstracts

Purpose: To improve the dose and LET distribution in the IMPTLET, we introduce a new optimization algorithm to search for the optimal beam orientation and count through the arc trajectory (BOC-IMPTLET). Methods: We introduce kmeans clustering analysis in the BOC-IMPTLET algorithm by analyzing the distribution of LET in the target from the full arc trajectory. The optimal of cluster count was used as beam count, which was determined based on the SSE (Sum of Square Error) value and the angle of the corresponding centroid of each cluster was used as beam orientation, respectively. The BOC-IMPTLET algorithm was implemented in the …


Improving Dose-Response Correlations For Locally Advanced Nsclc Patients Treated With Imrt Or Pspt, Yulun He May 2023

Improving Dose-Response Correlations For Locally Advanced Nsclc Patients Treated With Imrt Or Pspt, Yulun He

Dissertations and Theses (Open Access)

The standard of care for locally advanced non-small cell lung cancer (NSCLC) is concurrent chemo-radiotherapy. Despite recent advancements in radiation delivery methods, the median survival time of NSCLC patients remains below 28 months. Higher tumor dose has been found to increase survival but also a higher rate of radiation pneumonitis (RP) that affects breathing capability. In fear of such toxicity, less-aggressive treatment plans are often clinically preferred, leading to metastasis and recurrence. Therefore, accurate RP prediction is crucial to ensure tumor coverage to improve treatment outcome. Current models have associated RP with increased dose but with limited accuracy as they …


Comparison Of Reconstructed Prompt Gamma Emissions Using Maximum Likelihood Estimation And Origin Ensemble Algorithms For A Compton Camera System Tailored To Proton Range Monitoring, Ingrid Valencia Lozano, George Dedes, Steve Peterson, Dennis Mackin, Andreas Zoglauer, Sam Beddar, Stephen Avery, Jerimy Polf, Katia Parodi May 2023

Comparison Of Reconstructed Prompt Gamma Emissions Using Maximum Likelihood Estimation And Origin Ensemble Algorithms For A Compton Camera System Tailored To Proton Range Monitoring, Ingrid Valencia Lozano, George Dedes, Steve Peterson, Dennis Mackin, Andreas Zoglauer, Sam Beddar, Stephen Avery, Jerimy Polf, Katia Parodi

Faculty, Staff and Student Publications

Compton-based prompt gamma (PG) imaging is being investigated by several groups as a potential solution for in vivo range monitoring in proton therapy. The performance of this technique depends on the detector system as well as the ability of the reconstruction method to obtain good spatial resolution to establish a quantitative correlation between the PG emission and the proton beam range in the patient. To evaluate the feasibility of PG imaging for range monitoring, we quantitatively evaluated the emission distributions reconstructed by a Maximum Likelihood Expectation Maximization (MLEM) and a Stochastic Origin Ensemble (SOE) algorithm. To this end, we exploit …


Stereotactic Body Proton Therapy For Early Stage Non-Small Cell Lung Cancer – Technical Challenges And Solutions: The Md Anderson Experience, X Ronald Zhu, Yuting Li, Ming Yang, Thomas J Whitaker, Paige A Taylor, Xiaodong Zhang, Falk Poenisch, Narayan Sahoo, Zhongxing Liao, Joe Y Chang Jan 2023

Stereotactic Body Proton Therapy For Early Stage Non-Small Cell Lung Cancer – Technical Challenges And Solutions: The Md Anderson Experience, X Ronald Zhu, Yuting Li, Ming Yang, Thomas J Whitaker, Paige A Taylor, Xiaodong Zhang, Falk Poenisch, Narayan Sahoo, Zhongxing Liao, Joe Y Chang

Faculty, Staff and Student Publications

Our randomized clinical study comparing stereotactic body radiotherapy (SBRT) and stereotactic body proton therapy (SBPT) for early stage non-small cell lung cancer (NSCLC) was closed prematurely owing to poor enrollment, largely because of lack of volumetric imaging and difficulty in obtaining insurance coverage for the SBPT group. In this article, we describe technology improvements in our new proton therapy center, particularly in image guidance with cone beam CT (CBCT) and CT on rail (CTOR), as well as motion management with real-time gated proton therapy (RGPT) and optical surface imaging. In addition, we have a treatment planning system that provides better …


The First Modeling Of The Spot-Scanning Proton Arc(Sparc) Delivery Sequence And Investigating Its Efficiency Improvement, Xuanfeng Ding, Gang Liu, Lewei Zhao, Rohan Deraniyagala, Craig Stevens, Di Yan, Xiaoqiang Li Apr 2022

The First Modeling Of The Spot-Scanning Proton Arc(Sparc) Delivery Sequence And Investigating Its Efficiency Improvement, Xuanfeng Ding, Gang Liu, Lewei Zhao, Rohan Deraniyagala, Craig Stevens, Di Yan, Xiaoqiang Li

Conference Presentation Abstracts

Purpose: Introduce an experimental approach to model a precise prototype arc system and quantitatively assess its efficiency improvement in the routine proton clinical operation. Methods: The SPArc delivery sequence model(DSMSPArc) includes two kinds of parameters:(1) mechanical parameters. (2) irradiation parameters. Log files and an independent gantry inclinometer were used to derive the irradiation parameters through a series of test plans. The in-house DSMSPArc was established by fitting both mechanical and irradiation parameters. Eight SPArc plans from different disease sites were used to validate the model’s accuracy. To assess the treatment efficiency improvement, the DSMSPArc was used to simulate the SPArc …


A Direct Machine-Specific Parameters Incorporated Spot-Scanning Proton Arc (Sparc) Algorithm, Gang Liu, Lewei Zhao, Di Yan, Xiaoqiang Li, Xuanfeng Ding Apr 2022

A Direct Machine-Specific Parameters Incorporated Spot-Scanning Proton Arc (Sparc) Algorithm, Gang Liu, Lewei Zhao, Di Yan, Xiaoqiang Li, Xuanfeng Ding

Conference Presentation Abstracts

Purpose: To address the challenges of generating a deliverable and efficient spot-scanning proton arc (SPArc) plan for a proton therapy system. We developed a novel SPArc optimization algorithm (SPArcDMSP) by directly incorporating machinespecific parameters such as mechanical constraints and delivery sequence. Method and Material: A SPArc delivery sequence model (DSMarc) was built based on the machine-specific parameters of the prototype arc delivery system IBA ProteusONEt. The SPArcDMSP resamples and adjusts each control point’s delivery speed based on the DSMarc calculation through the iterative approach (Fig1). Users could set the expected delivery time and gantry max acceleration as a mechanical constraint …


Toward Online Adaptive Proton Therapy Of Sinonasal Cancer: The Dosimetric Accuracy Of Utilizing Deep-Learning Synthetic Ct From Cbct For Daily Treatment Dose Verification, An Qin, Lewei Zhao, Shupeng Chen, Xiaoqiang Li, Weili Zheng, Di Yan, Rohan Deraniyagala, Xuanfeng Ding Jun 2021

Toward Online Adaptive Proton Therapy Of Sinonasal Cancer: The Dosimetric Accuracy Of Utilizing Deep-Learning Synthetic Ct From Cbct For Daily Treatment Dose Verification, An Qin, Lewei Zhao, Shupeng Chen, Xiaoqiang Li, Weili Zheng, Di Yan, Rohan Deraniyagala, Xuanfeng Ding

Conference Presentation Abstracts

No abstract provided.


Assess The Interplay Effect Based On The Cyclotron Accelerator Proton Therapy System Machine-Specific Delivery Sequence Model, Lewei Zhao, Gang Liu, J Shen, A Lee, Di Yan, Rohan Deraniyagala, Craig Stevens, Weili Zheng, Xiaoqiang Li, S Tang, Xuanfeng Ding Jun 2021

Assess The Interplay Effect Based On The Cyclotron Accelerator Proton Therapy System Machine-Specific Delivery Sequence Model, Lewei Zhao, Gang Liu, J Shen, A Lee, Di Yan, Rohan Deraniyagala, Craig Stevens, Weili Zheng, Xiaoqiang Li, S Tang, Xuanfeng Ding

Conference Presentation Abstracts

No abstract provided.


Structure Sparsity Of The Spot Optimization In Proton Arc Therapy, Lewei Zhao Apr 2021

Structure Sparsity Of The Spot Optimization In Proton Arc Therapy, Lewei Zhao

Conference Presentation Abstracts

Radiation therapy is one of the main cancer treatments that uses radiation to kill cancer cells. Proton therapy, or proton radiotherapy, is a type of particle therapy that uses a beam of protons to irradiate tumor volume. Beaumont proton therapy center research group invented the first robust and delivery-efficient spot-scanning proton arc (SPArc) therapy in 2016. Based on our beam modeling platform, we have found that the spot switching time (SSWT) is proportional to spot numbers. We aim to develop a direct mathematical optimization method to reduce the spot numbers for SPArc based on an independent optimization method to reduce …


Modeling Proton Relative Biological Effectiveness Using Monte Carlo Simulations Of Microdosimetry, Mark A. Newpower Aug 2019

Modeling Proton Relative Biological Effectiveness Using Monte Carlo Simulations Of Microdosimetry, Mark A. Newpower

Dissertations and Theses (Open Access)

Proton therapy is a radiotherapy modality that can offer a better physical dose distribution when compared to photon radiotherapy by taking advantage of the Bragg peak, a narrow region of rapid energy loss. Proton therapy is also known to offer an enhanced relative biological effectiveness (RBE) compared to photons. In the current clinical standard, RBE is fixed at 1.1 at all points along the proton beam, meaning protons are assumed to require 10% less dose than photons to achieve target coverage and organ at risk (OAR) sparing. However, there is mounting clinical evidence, and a significant number of in vitro …