Open Access. Powered by Scholars. Published by Universities.®

Radiation Medicine Commons™

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 15 of 15

Full-Text Articles in Radiation Medicine

Computed Tomography For Four-Dimensional Dose Calculation: Effect Of Detector Array Length, Inhwan Yeo, Qianyi Xu Apr 2026

Computed Tomography For Four-Dimensional Dose Calculation: Effect Of Detector Array Length, Inhwan Yeo, Qianyi Xu

Department of Radiation Oncology Faculty Papers

PURPOSE: Four-dimensional computed tomography (4DCT) is susceptible to a geometrical error when respiration changes upon patient shift. 4DCT using 16-cm detector arrays, not needing the shift, has been shown to improve geometrical accuracy, compared with a conventional 4DCT (4-cm array), albeit with some Hounsfield unit discrepancies. The 4DCTs were validated for 4D planning.

MATERIALS AND METHODS: A lung-mimicking phantom containing a spherical target with ten respiratory traces and three tumor-shaped targets with their traces was respectively imaged when, to each of the ten-positions/phases, the lung was moved (1) step-wisely by helical scan at each movement (ground truth; 4DCTGT), …


Fast And Accurate Measurement Of Small Field Dosimetry Using A Novel Scintillation Detector, Yiding Han, Jingzhu Xu, Yao Hao, Baozhou Sun Dec 2025

Fast And Accurate Measurement Of Small Field Dosimetry Using A Novel Scintillation Detector, Yiding Han, Jingzhu Xu, Yao Hao, Baozhou Sun

Faculty, Staff and Students Publications

Background: The most used instruments for small-field dosimetry have notable limitations, including the need for correction of output factors, limited scanning speeds, and challenges in alignment for percentage depth dose (PDD) measurements, particularly for extremely small fields. However, plastic scintillation detectors (PSDs) are an attractive alternative for small-field dosimetry due to their correction-free nature, linear dose response, and fast response time.

Purpose: This study evaluates the robustness and accuracy of the dosimetric measurements using a new water-equivalent PSD in small-field dosimetry. The study also aims to report accurate measurements of output factors, profiles, and an indirect method for measuring PDD …


Evaluation Of Image Quality In Mobile Cone-Beam Ct With Dose Modulation Using Automatic Exposure Control: A Phantom Study, Keita Okazaki, Wenchao Cao, Reza Taleei, Firas Mourtada, Jun Li, Karen Mooney, Pramila Rani Anne, Yingxuan Chen Sep 2025

Evaluation Of Image Quality In Mobile Cone-Beam Ct With Dose Modulation Using Automatic Exposure Control: A Phantom Study, Keita Okazaki, Wenchao Cao, Reza Taleei, Firas Mourtada, Jun Li, Karen Mooney, Pramila Rani Anne, Yingxuan Chen

Department of Radiation Oncology Faculty Papers

BACKGROUND: The integration of mobile cone-beam computed tomography (CBCT) into brachytherapy workflows offers clinical advantages such as immediate verification of applicator placement and adaptive treatment planning. These benefits require sufficient image quality to delineate applicators, target volumes, and organs at risk. A systematic evaluation of automatic exposure control (AEC) settings, radiation dose, and image quality is essential to ensure clinically acceptable imaging while minimizing patient exposure.

PURPOSE: This study evaluates the characteristics of AEC and its impact on image quality and radiation dose in a mobile CBCT system used for brachytherapy.

METHODS: The Elekta ImagingRing CBCT system was used to …


Evaluating Artifact-Free Four-Dimensional Computer Tomography With 16 Cm Detector Array, Inhwan Yeo, Wei Nie, Jiajin Fan, Mindy Joo, Michael Correa, Qianyi Xu Apr 2025

Evaluating Artifact-Free Four-Dimensional Computer Tomography With 16 Cm Detector Array, Inhwan Yeo, Wei Nie, Jiajin Fan, Mindy Joo, Michael Correa, Qianyi Xu

Department of Radiation Oncology Faculty Papers

PURPOSE: To evaluate a 16 cm-array axial four-dimensional computer tomography (4DCT) in comparison with a 4 cm-array 4DCT in the presence of respiration irregularity.

METHOD: Ten traces of lung tumor motion from CyberKnife treatments were imported to move the lung cylinder, containing a spherical target, of a phantom. Images were acquired for the lung that moved to each of the 10-positions/phases (1) step-wisely by nominal helical scan at each movement (ground truth), (2) continuously by 4D scan with the 16 cm array, and (3) the same with the 4 cm array, involving table shift. Irregularities, consisting of baseline shift and/or …


Robust Automated Method Of Spatial Resolution Measurement In Radiotherapy Ct Simulation Images, Pavel Govyadinov, Rick R Layman, Tucker Netherton, Raymond Mumme, Aaron K Jones, Laurence E Court, Moiz Ahmad Mar 2025

Robust Automated Method Of Spatial Resolution Measurement In Radiotherapy Ct Simulation Images, Pavel Govyadinov, Rick R Layman, Tucker Netherton, Raymond Mumme, Aaron K Jones, Laurence E Court, Moiz Ahmad

Faculty, Staff and Student Publications

Background: Variation in imaging protocol, patient positioning, and the presence of artifacts can vary image quality in CT images used for radiotherapy planning. Automated methods for spatial resolution (SR) estimation exist but require further investigation and validation for wider adoption.

Purpose: To validated previously existing algorithm for SR estimation and introduce improvements that make it robust to patient positioning, CT protocol, site, and artifacts.

Method: A reference algorithm based on the previous gold standard was recreated and modified to improve robustness. The algorithms were tested on three different datasets: (1) a cylindrical ACR CT QC phantom scanned using a Siemens …


Optimization Processes Of Clinical Chelation-Based Radiopharmaceuticals For Pathway-Directed Targeted Radionuclide Therapy In Oncology, Katsumi Tomiyoshi, Lydia J. Wilson, Firas Mourtada, Jennifer Sims Mourtada, Yuta Namiki, Wataru Kamata, David J. Yang, Tomio Inoue Nov 2024

Optimization Processes Of Clinical Chelation-Based Radiopharmaceuticals For Pathway-Directed Targeted Radionuclide Therapy In Oncology, Katsumi Tomiyoshi, Lydia J. Wilson, Firas Mourtada, Jennifer Sims Mourtada, Yuta Namiki, Wataru Kamata, David J. Yang, Tomio Inoue

Department of Radiation Oncology Faculty Papers

Targeted radionuclide therapy (TRT) for internal pathway-directed treatment is a game changer for precision medicine. TRT improves tumor control while minimizing damage to healthy tissue and extends the survival for patients with cancer. The application of theranostic-paired TRT along with cellular phenotype and genotype correlative analysis has the potential for malignant disease management. Chelation chemistry is essential for the development of theranostic-paired radiopharmaceuticals for TRT. Among image-guided TRT,


Exploiting The Heavy Chain Glycans For The Improvement Of Radioimmunoconjugates, Cindy Rodriguez Sep 2024

Exploiting The Heavy Chain Glycans For The Improvement Of Radioimmunoconjugates, Cindy Rodriguez

Dissertations, Theses, and Capstone Projects

Radiolabeled antibodies have become indispensable tools in nuclear medicine. However, the natural roles of antibodies within the immune system mean that they have several intrinsic limitations as a platform for radiopharmaceuticals. A handful of recent preclinical studies suggest that binding by FcR and particularly FcyRI can affect the pharmacokinetic profiles of 89Zr-labeled radioimmunoconjugates. Fc receptors (FcR) are responsible for many of the interactions between immunoglobulins (IgG) and immune cells. In biomedicine, this interplay is critical to the activity of several types of immunotherapeutics; however, relatively little is known about how FcRs affect the in vivo performance of radiolabeled antibodies. Antibodies …


Ai-Assisted Segmentation Tool For Brain Tumor Mr Image Analysis, Myungeun Lee, Jong Hyo Kim, Wookjin Choi, Ki Hong Lee Jul 2024

Ai-Assisted Segmentation Tool For Brain Tumor Mr Image Analysis, Myungeun Lee, Jong Hyo Kim, Wookjin Choi, Ki Hong Lee

Department of Radiation Oncology Faculty Papers

TumorPrism3D software was developed to segment brain tumors with a straightforward and user-friendly graphical interface applied to two- and three-dimensional brain magnetic resonance (MR) images. The MR images of 185 patients (103 males, 82 females) with glioblastoma multiforme were downloaded from The Cancer Imaging Archive (TCIA) to test the tumor segmentation performance of this software. Regions of interest (ROIs) corresponding to contrast-enhancing lesions, necrotic portions, and non-enhancing T2 high signal intensity components were segmented for each tumor. TumorPrism3D demonstrated high accuracy in segmenting all three tumor components in cases of glioblastoma multiforme. They achieved a better Dice similarity coefficient (DSC) …


An International Phantom Study Of Inter-Site Variability In Technetium-99m Image Quantification: Analyses From The Target Radioembolization Study, Grace Keane, Rob Van Rooij, Marnix Lam, S Cheenu Kappadath, Bilal Kovan, Stephanie Leon, Matthew Dreher, Kirk Fowers, Hugo De Jong May 2024

An International Phantom Study Of Inter-Site Variability In Technetium-99m Image Quantification: Analyses From The Target Radioembolization Study, Grace Keane, Rob Van Rooij, Marnix Lam, S Cheenu Kappadath, Bilal Kovan, Stephanie Leon, Matthew Dreher, Kirk Fowers, Hugo De Jong

Faculty, Staff and Student Publications

BACKGROUND: Personalised multi-compartment dosimetry based on [

RESULTS: Regarding the LSF, inter-site variation with planar site-specific protocols was minimal, as determined by comparing computed LSF between sites (interquartile range 9.6-10.1%). A standardised protocol did not improve variation (interquartile range 8.4-9.0%) but did improve mean accuracy compared to the site-specific protocols (5.0% error for standardised protocol vs 8.8% error for site-specific protocols). Regarding the CRC, inter-system variation was notable for site-specific SPECT protocols and could not be improved by the standardised protocol (CRC interquartile range for 37 mm sphere 0.5-0.7 and 0.6-0.8 respectively), however the standardised protocol did improve accuracy of …


High-Density Glass Scintillators For Proton Radiography-Relative Luminosity, Proton Response, And Spatial Resolution, Ethan Stolen, Ryan Fullarton, Rain Hein, Robin L Conner, Luiz G Jacobsohn, Charles-Antoine Collins-Fekete, Sam Beddar, Ugur Akgun, Daniel Robertson Mar 2024

High-Density Glass Scintillators For Proton Radiography-Relative Luminosity, Proton Response, And Spatial Resolution, Ethan Stolen, Ryan Fullarton, Rain Hein, Robin L Conner, Luiz G Jacobsohn, Charles-Antoine Collins-Fekete, Sam Beddar, Ugur Akgun, Daniel Robertson

Faculty, Staff and Student Publications

Proton radiography is a promising development in proton therapy, and researchers are currently exploring optimal detector materials to construct proton radiography detector arrays. High-density glass scintillators may improve integrating-mode proton radiography detectors by increasing spatial resolution and decreasing detector thickness. We evaluated several new scintillators, activated with europium or terbium, with proton response measurements and Monte Carlo simulations, characterizing relative luminosity, ionization quenching, and proton radiograph spatial resolution. We applied a correction based on Birks's analytical model for ionization quenching. The data demonstrate increased relative luminosity with increased activation element concentration, and higher relative luminosity for samples activated with europium. …


Three-Dimensional Microct Imaging Of Mouse Heart Development From Early Post-Implantation To Late Fetal Stages, Nanbing Li-Villarreal, Tara L Rasmussen, Audrey E Christiansen, Mary E Dickinson, Chih-Wei Hsu Jun 2023

Three-Dimensional Microct Imaging Of Mouse Heart Development From Early Post-Implantation To Late Fetal Stages, Nanbing Li-Villarreal, Tara L Rasmussen, Audrey E Christiansen, Mary E Dickinson, Chih-Wei Hsu

Faculty, Staff and Students Publications

Comprehensive detailed characterization of new mouse models can be challenging due to the individual focus involved in developing these models. Often models are engineered to test a specific hypothesis in a limited number of tissues, stages, and/or other contexts. Whether or not the model produces the desired phenotypes, phenotyping beyond the desired context can be extremely work intensive and these studies are often not undertaken. However, the general information resulting from broader phenotyping can be invaluable to the wider scientific community. The International Mouse Phenotyping Consortium (IMPC) and its subsidiaries, like the Knockout Mouse Project (KOMP), has made great strides …


Characterizing The Interplay Of Treatment Parameters And Complexity And Their Impact On Performance On An Iroc Imrt Phantom Using Machine Learning, Hunter Mehrens, Andrea Molineu, Nadia Hernandez, Laurence Court, Rebecca Howell, David Jaffray, Christine B Peterson, Julianne Pollard-Larkin, Stephen F Kry May 2023

Characterizing The Interplay Of Treatment Parameters And Complexity And Their Impact On Performance On An Iroc Imrt Phantom Using Machine Learning, Hunter Mehrens, Andrea Molineu, Nadia Hernandez, Laurence Court, Rebecca Howell, David Jaffray, Christine B Peterson, Julianne Pollard-Larkin, Stephen F Kry

Faculty, Staff and Student Publications

AIM OF THE STUDY: To elucidate the important factors and their interplay that drive performance on IMRT phantoms from the Imaging and Radiation Oncology Core (IROC).

METHODS: IROC's IMRT head and neck phantom contains two targets and an organ at risk. Point and 2D dose are measured by TLDs and film, respectively. 1,542 irradiations between 2012-2020 were retrospectively analyzed based on output parameters, complexity metrics, and treatment parameters. Univariate analysis compared parameters based on pass/fail, and random forest modeling was used to predict output parameters and determine the underlying importance of the variables.

RESULTS: The average phantom pass rate was …


An Analytical Expression For R50% Dependent On Ptv Surface Area And Volume: A Cranial Srs Comparison, Dharmin D. Desai, Ellis Lee Johnson, Ivan L. Cordrey Jan 2021

An Analytical Expression For R50% Dependent On Ptv Surface Area And Volume: A Cranial Srs Comparison, Dharmin D. Desai, Ellis Lee Johnson, Ivan L. Cordrey

Radiation Medicine Faculty Publications

The intermediate dose spill for a stereotactic radiosurgery (SRS) plan can be quantified with the metric R50%, defined as the 50% isodose cloud volume (VIDC50%) divided by the volume of the planning target volume (PTV). By coupling sound physical principles with the basic definition of R50%, we derive an analytical expression for R50% for a spherical PTV. Our analytical expression depends on three quantities: the surface area of PTV (SAPTV), the volume of PTV (VPTV), and the distance of dose drop-off to 50% (Δr). The value of ∆r was obtained from a simple set …


Targeting Accuracy Considerations For Simultaneous Tumor Treating Fields Antimitotic Therapy During Robotic Hypofractionated Radiation Therapy., Sharmi Biswas, Irina Kapitanova, Sabrina Divekar, Jimm Grimm, Ian J Butterwick, Daniel Garren, Lawrence R Kleinberg, Kristin J Redmond, Michel Lacroix, Anand Mahadevan, Kenneth M Forster Jan 2021

Targeting Accuracy Considerations For Simultaneous Tumor Treating Fields Antimitotic Therapy During Robotic Hypofractionated Radiation Therapy., Sharmi Biswas, Irina Kapitanova, Sabrina Divekar, Jimm Grimm, Ian J Butterwick, Daniel Garren, Lawrence R Kleinberg, Kristin J Redmond, Michel Lacroix, Anand Mahadevan, Kenneth M Forster

College of Health Professions Faculty Papers

Purpose: Tumor treating fields (TTFields) is a novel antimitotic treatment that was first proven effective for glioblastoma multiforme, now with trials for several extracranial indications underway. Several studies focused on concurrent TTFields therapy with radiation in the same time period, but were not given simultaneously. This study evaluates the targeting accuracy of simultaneous radiation therapy while TTFields arrays are in place and powered on, ensuring that radiation does not interfere with TTFields and TTFields does not interfere with radiation. This is one of several options to enable TTFields to begin several weeks sooner, and opens potential for synergistic effects of …


Sub-Region Based Radiomics Analysis For Survival Prediction In Oesophageal Tumours Treated By Definitive Concurrent Chemoradiotherapy, Congying Xie, Pengfei Yang, Xuebang Zhang, Lei Xu, Xiaoju Wang, Xiadong Li, Luhan Zhang, Ruifei Xie, Ling Yang, Zhao Jing, Hongfang Zhang, Lingyu Ding, Yu Kuang, Tianye Niu, Shixiu Wu May 2019

Sub-Region Based Radiomics Analysis For Survival Prediction In Oesophageal Tumours Treated By Definitive Concurrent Chemoradiotherapy, Congying Xie, Pengfei Yang, Xuebang Zhang, Lei Xu, Xiaoju Wang, Xiadong Li, Luhan Zhang, Ruifei Xie, Ling Yang, Zhao Jing, Hongfang Zhang, Lingyu Ding, Yu Kuang, Tianye Niu, Shixiu Wu

Health Physics and Diagnostic Sciences Faculty Research

Background: Evaluating clinical outcome prior to concurrent chemoradiotherapy remains challenging for oesophageal squamous cell carcinoma (OSCC) as traditional prognostic markers are assessed at the completion of treatment. Herein, we investigated the potential of using sub-region radiomics as a novel tumour biomarker in predicting overall survival of OSCC patients treated by concurrent chemoradiotherapy. Methods: Independent patient cohorts from two hospitals were included for training (n = 87) and validation (n = 46). Radiomics features were extracted from sub-regions clustered from patients' tumour regions using K-means method. The LASSO regression for ‘Cox’ method was used for feature selection. The survival prediction model …