Open Access. Powered by Scholars. Published by Universities.®
- Institution
- Keyword
-
- Customization (2)
- 3D Printing (1)
- Absorbable staples (1)
- Additive manufacturing (AM) (1)
- Biocompatibility (1)
-
- Burns (1)
- Cranioplasty (1)
- Decompressive craniectomy (1)
- Disruptive (1)
- Emerging (1)
- Enthesis (1)
- Finite element analysis (1)
- Healthcare (1)
- Integration (1)
- Large skull defect (1)
- Mandibular reconstructive surgery (1)
- Medical application (1)
- NPGA (1)
- PCL (1)
- PLLA (1)
- Polymethyl methacrylate (1)
- Porosity (1)
- Rotator cuff (1)
- Single point incremental forming (1)
- Skin grafts (1)
- Staple remover (1)
- Stiffness matching (1)
- Superelastic NiTi (1)
- Surgical equipment (1)
- Technology (1)
- Publication
- Publication Type
Articles 1 - 8 of 8
Full-Text Articles in Plastic Surgery
Investigation Using Single Point Incremental Forming (Spif) To Fabricate Patient-Specific, Titanium Orbital Floor Implants, Elizabeth M. Mamros, Lauren E. Blaha Md, Christian A. Kauffman Md
Investigation Using Single Point Incremental Forming (Spif) To Fabricate Patient-Specific, Titanium Orbital Floor Implants, Elizabeth M. Mamros, Lauren E. Blaha Md, Christian A. Kauffman Md
Faculty Conference Papers and Presentations
The floor of the human orbit is composed of thin bone that is prone to traumatic fracture. This leads to a loss of support for the eye, which can cause vision changes. Therefore, fractures may need surgical reconstruction using a thin, sheet-like implant. Titanium implants are available off-the-shelf in standard sizes, but fitting to each patient’s unique anatomy requires surgeons to cut, file, and bend these plates. This can be time-consuming and imprecise. To both save time and ensure a perfect fit for the patient, a custom plate can be created prior to surgery. This investigation focuses on single-point incremental …
A Customized Large Single-Piece Bifrontal Implant For Post-Craniectomy Defect Reconstruction: A Case Study, Omid Ghaderzadeh, Ehsan Amirbeyk, Seyed Roholah Ghodsi, Zahra Namazi, Lobat Tayebi
A Customized Large Single-Piece Bifrontal Implant For Post-Craniectomy Defect Reconstruction: A Case Study, Omid Ghaderzadeh, Ehsan Amirbeyk, Seyed Roholah Ghodsi, Zahra Namazi, Lobat Tayebi
Electrical & Computer Engineering Faculty Publications
Background: Large bifrontal defects pose unique reconstruction challenges due to their complex curvature and mechanical requirements. This case demonstrated how computer-aided design/manufacturing (CAD/CAM) enabled precise single-piece polymethyl methacrylate (PMMA) implant fabrication, thereby overcoming traditional limitations. Case presentation: A 25-year-old male who had undergone bifrontal decompressive craniectomy suffered a severe traumatic brain injury. The autologous bone flap had been temporarily stored in a subcutaneous fat area of the abdomen for 3 months to preserve its viability. A secondary cranioplasty was then performed using titanium miniplates and self-tapping screws for final fixation. After 2 years, the patient developed empyema and a brain …
Fibrin Glue Acutely Blocks Distal Muscle Contraction After Confirmed Polyethylene Glycol Nerve Fusion: An Animal Study., Alec H Fisher, Parker H Johnsen, Andrew Simon, Cameron J Burns, Vineeth Romiyo, Elliot B Bodofsky, Sebastian Vega, David A Fuller
Fibrin Glue Acutely Blocks Distal Muscle Contraction After Confirmed Polyethylene Glycol Nerve Fusion: An Animal Study., Alec H Fisher, Parker H Johnsen, Andrew Simon, Cameron J Burns, Vineeth Romiyo, Elliot B Bodofsky, Sebastian Vega, David A Fuller
Cooper Medical School of Rowan University Departmental Research
BACKGROUND: Polyethylene glycol (PEG) is a synthetic, biodegradable, and hyperosmotic material promising in the treatment of acute peripheral nerve injuries. Our team set out to investigate the impact of fibrin glue upon PEG fusion in a rat model.
METHODS: Eighteen rats underwent sciatic nerve transection and PEG fusion. Electrophysiologic testing was performed to measure nerve function and distal muscle twitch. Fibrin glue was applied and testing repeated. Due to preliminary findings, fibrin glue was applied to an uncut nerve in five rodents and testing was conducted before and after glue application. Mann-Whitney U tests were used to compare median values …
Degradable Staples And Delivery Device, Meha Elango, Jessica Cabrera, Makayla Scarpitti, Kareemat Melaiye
Degradable Staples And Delivery Device, Meha Elango, Jessica Cabrera, Makayla Scarpitti, Kareemat Melaiye
Williams Honors College, Honors Research Projects
The scope of this project is to design a method to secure skin grafts to healthy tissue. The ultimate goal for the proposed method is to be dissolvable in some form. Currently, skin grafts procedures utilize staples in most cases to hold a skin graft in place, but there are disadvantages that come with it. Staples are easy to place, but time consuming during the removal procedure. They also cause a lot of pain and discomfort for the patient. The goal of this project is to determine a way a secure skin grafts to healthy skin in order to reduce …
Enhancement Of Viable Adipose-Derived Stem Cells In Lipoaspirate By Buffering Tumescent With Sodium Bicarbonate, Ashish Francis Md, Wei Z. Wang Md, Joshua J. Goldman Md, Xin-Hua Fang Mt, Shelley J. Williams Ms, Richard C. Baynosa Md; Facs
Enhancement Of Viable Adipose-Derived Stem Cells In Lipoaspirate By Buffering Tumescent With Sodium Bicarbonate, Ashish Francis Md, Wei Z. Wang Md, Joshua J. Goldman Md, Xin-Hua Fang Mt, Shelley J. Williams Ms, Richard C. Baynosa Md; Facs
School of Medicine Faculty Research
Background: Fat grafting is a growing field within plastic surgery. Adipose-derived stem cells (ASCs) and stromal vascular fracture (SVF) may have a role in fat graft survival. Our group previously demonstrated a detrimental effect on ASC survival by the lidocaine used in tumescent solution. Sodium bicarbonate (SB) buffers the acidity of lidocaine. The purpose of this study was to determine whether SB buffering is a practical method to reduce ASC and SVF apoptosis and necrosis seen with common lidocaine-containing tumescent solution. Methods: Human patients undergoing bilateral liposuction for any indication were included in this study. An internally controlled, split-body design …
The Effects Of Emerging Technology On Healthcare And The Difficulties Of Integration, Skyler J. Pavlish-Carpenter
The Effects Of Emerging Technology On Healthcare And The Difficulties Of Integration, Skyler J. Pavlish-Carpenter
Honors Undergraduate Theses
Background: Disruptive technology describes technology that is significantly more advanced than previous iterations, such as: 3D printing, genetic manipulation, stem cell research, innovative surgical procedures, and computer-based charting software. These technologies often require extensive overhauls to implement into older systems and must overcome many difficult financial and societal complications before they can be widely used. In a field like healthcare that makes frequent advancements, these difficulties can mean that the technology will not be utilized to its full potential or implemented at all.
Objective: To determine the inhibiting factors that prevent disruptive technology from being implemented in conventional healthcare.
Methods: …
Finite Element Simulation And Additive Manufacturing Of Stiffness-Matched Niti Fixation Hardware For Mandibular Reconstruction Surgery, Ahmadreza Jahadakbar, Narges Shayesteh Moghaddam, Amirhesam Amerinatanzi, David Dean, Haluk E. Karaca, Mohammad Elahinia
Finite Element Simulation And Additive Manufacturing Of Stiffness-Matched Niti Fixation Hardware For Mandibular Reconstruction Surgery, Ahmadreza Jahadakbar, Narges Shayesteh Moghaddam, Amirhesam Amerinatanzi, David Dean, Haluk E. Karaca, Mohammad Elahinia
Mechanical Engineering Faculty Publications
Process parameters and post-processing heat treatment techniques have been developed to produce both shape memory and superelastic NiTi using Additive Manufacturing. By introducing engineered porosity, the stiffness of NiTi can be tuned to the level closely matching cortical bone. Using additively manufactured porous superelastic NiTi, we have proposed the use of patient-specific, stiffness-matched fixation hardware, for mandible skeletal reconstructive surgery. Currently, Ti-6Al-4V is the most commonly used material for skeletal fixation devices. Although this material offers more than sufficient strength for immobilization during the bone healing process, the high stiffness of Ti-6Al-4V implants can cause stress shielding. In this paper, …
Evaluation Of Tissue-Engineered Tendon Enthesis Polymer Constructs, Joshua A. Bundy Bs, Mary Beth Wade Phd, Hitomi Nakao Md, Phillip Mcclellan Phd, Qing Yu Phd, Robin Jacquet-Childs Ms, William J. Landis Phd
Evaluation Of Tissue-Engineered Tendon Enthesis Polymer Constructs, Joshua A. Bundy Bs, Mary Beth Wade Phd, Hitomi Nakao Md, Phillip Mcclellan Phd, Qing Yu Phd, Robin Jacquet-Childs Ms, William J. Landis Phd
Williams Honors College, Honors Research Projects
Both scientists and clinicians have proposed tissue engineering as the future of medicine. The possibilities for tissue engineering, that is, fabrication of tissues and organs in the laboratory and their translation to patients, appear to be endless, and many believe that this new approach in medicine will result in abolishing many common ailments, injuries, and congenital defects. Injuries to a tendon enthesis, the normal tissue connection between tendon and bone, are of particular concern to clinicians because of their frequency and failure to repair as a result of surgery. While these injuries may not be life threatening, they can certainly …