Open Access. Powered by Scholars. Published by Universities.®

Cardiology Commons

Open Access. Powered by Scholars. Published by Universities.®

Radiology

Institution
Keyword
Publication Year
Publication
Publication Type

Articles 61 - 90 of 91

Full-Text Articles in Cardiology

Modeling Of Patient-Specific Periaortic Mechanics And Pulmonary Artery Hemodynamics Based On Phase-Contrast Magnetic Resonance Imaging Sequences., Johane H. Bracamonte Jan 2022

Modeling Of Patient-Specific Periaortic Mechanics And Pulmonary Artery Hemodynamics Based On Phase-Contrast Magnetic Resonance Imaging Sequences., Johane H. Bracamonte

Theses and Dissertations

Inverse modeling in cardiovascular medicine is a collection of methodologies that can provide non-invasive patient-specific estimations of clinical risk factors using medical imaging as inputs. Its incorporation into clinical practice has the potential to improve diagnosis and treatment planning with low associated risks and costs.

Herein, three different phase contrast magnetic resonance imaging (MRI) modalities were implemented as input data, displacement encoding with stimulated echoes (DENSE MRI) applied, and time-resolved velocity encoding phase-contrast MRI, in 1D and 3D, applied to pulmonary artery (PA) hemodynamics.

A model to account for the effect of periaortic interactions due to static and dynamic structures …


Incidental Finding Of Anomalous Pulmonary Venous Return Of The Left Upper Lobe, A Rare Anatomical Variation, Anika Dutta, Loren Zuiderveld Jul 2021

Incidental Finding Of Anomalous Pulmonary Venous Return Of The Left Upper Lobe, A Rare Anatomical Variation, Anika Dutta, Loren Zuiderveld

Journal of Patient-Centered Research and Reviews

Partial anomalous pulmonary venous return (PAPVR) is a rare congenital abnormality in which 1 to 3 of the pulmonary veins connect to the right atrium rather than the left atrium. In this synthesis of the literature on PAPVR of the left upper lobe, we attempt to illustrate this clinical entity using a case detected incidentally on chest computed tomography, explain the anatomical aspects of this anomaly, and summarize the reported incidence and etiology of left-sided PAPVR. Lastly, differential diagnoses, clinical relevance, and management of left-sided PAPVR are presented. The identification of this variant is important, as it may have serious …


Pediatric Pulmonary Artery Aneurysms Causing Pulmonary Hemorrhage: A Case Of Transcatheter Intervention While On Va Ecmo Support, Igor Areinamo May 2021

Pediatric Pulmonary Artery Aneurysms Causing Pulmonary Hemorrhage: A Case Of Transcatheter Intervention While On Va Ecmo Support, Igor Areinamo

Research Days

Background: The incidence of pulmonary artery aneurysm (PAA) in children remains unknown. There are few reports of a transcutaneous interventional approach to address this type of pathology. Management of PAAs while on VA ECMO has not been described in pediatrics.

Objectives/Goal:

Methods/Design:

Case: 9-year-old previously healthy male presented with MRSA associated ARDS and sepsis requiring urgent VA ECMO cannulation. Chest CT done on ECMO day 22 showed development of right sided PAAs. Patient had an episode of significant pulmonary hemorrhage. Angiogram demonstrated two fusiform right PAAs, one of which had ruptured and was bleeding into the lung parenchyma. Patient had …


Transcatheter Aortic Valve Replacement (Tavr), Emily Wentzel Jan 2021

Transcatheter Aortic Valve Replacement (Tavr), Emily Wentzel

Student Research Poster Presentations 2021

Transcatheter Aortic Valve Replacement (TAVR)

Emily Wentzel

Lynn Blazaskie

Abstract

Transcatheter Aortic Valve Replacement, or TAVR, is a procedure that is performed when a patient is in need of a new aortic valve. This is a procedure done to relieve symptoms of aortic stenosis. TAVR first began in France in 2002 and came to the United States in 2005. Cardiac Catheterization is the modality that is utilized in order to perform this procedure along with a cardiac catheterization team. The team includes cardiac catheterization technologists, doctors, nurses, cardiovascular surgeons, and ultrasound technologists. Cardiac Catheterization is a minor surgical procedure that …


Conference Proceedings: Aurora Scientific Day 2020 Oct 2020

Conference Proceedings: Aurora Scientific Day 2020

Journal of Patient-Centered Research and Reviews

Abstracts published in this supplement were among those presented at the 46th annual Aurora Scientific Day research symposium, held virtually on May 20, 2020. The symposium provides a forum for describing research studies conducted by faculty, fellows, residents, and allied health professionals affiliated with Wisconsin-based Aurora Health Care, a part of the Advocate Aurora Health health system, which publishes the Journal of Patient-Centered Research and Reviews.


Detection Of Left Ventricular Thrombi On Cardiac Magnetic Resonance Viability Studies, Donya Ahmed Alhassan, Khawaja Bilal Waheed, Muhammad Nasim Sharif, Muhammad Zia Ulhassan, Fazal Ghaffar, Khaled Saleh Saleem, Emad Fouad Mahmoud Said, Bayan Mohammed Altalaq, Zechariah Jebakumar Arulanantham, Ahmad Omar Qarmash Aug 2020

Detection Of Left Ventricular Thrombi On Cardiac Magnetic Resonance Viability Studies, Donya Ahmed Alhassan, Khawaja Bilal Waheed, Muhammad Nasim Sharif, Muhammad Zia Ulhassan, Fazal Ghaffar, Khaled Saleh Saleem, Emad Fouad Mahmoud Said, Bayan Mohammed Altalaq, Zechariah Jebakumar Arulanantham, Ahmad Omar Qarmash

Journal of the Saudi Heart Association

Objective: To highlight detection of left ventricular thrombi on cardiac magnetic resonance (CMR) viability studies.

Method: This retrospective observational study was conducted in the Radiology Department at our Hospital in Dhahran, from April 2015-2019. All recently re-perfused (post-percutaneous coronary intervention/ PCI) patients with ST-segment elevation myocardial infarctions (STEMI), having low ejection fractions (

Results: Of the 125 patients, most were men (71.2%) with a mean age of 56.78 years. Eleven patients had left ventricular thrombi (8.8%), and most of these were anterior wall infarctions with low ejection fractions (

Conclusion: Left ventricular thrombi can be detected on cardiac viability studies …


Effect Of Contrast-Enhanced Echocardiograms On The Prognosis Of Infective Endocarditis, D. Arias, E. Halpern, F. Forsberg, J. R. Eisenbrey Jan 2020

Effect Of Contrast-Enhanced Echocardiograms On The Prognosis Of Infective Endocarditis, D. Arias, E. Halpern, F. Forsberg, J. R. Eisenbrey

Phase 1

Objective - Infective endocarditis (IE) is an infectious disease of the cardiac valves where bacteria colonize the valves; typically, via the formation of vegetations. Recent research has shown that the microbubbles in a contrast-enhanced ultrasound (CEUS) examination can move and dislodge bacterial vegetations in vitro. This study investigated whether CEUS resulted in faster resolution of IE in vivo by dislodging the vegetations.

Methods - This IRB approved retrospective study reviewed 36 patients who were diagnosed with IE via echocardiography. Data was sourced from patients within the Jefferson University Hospital’s Cardiology EMR system by searching for contrast and vegetation from …


Changes In Ventricular Depolarisation Vectors During Exercise Caused By Regional Myocardial Ischaemia, Cameruddin Vellani, Satwat Hashmi, Sadia Mahmud, Mohammad Yusuf, Safia Awan, Khawar Kazmi Nov 2019

Changes In Ventricular Depolarisation Vectors During Exercise Caused By Regional Myocardial Ischaemia, Cameruddin Vellani, Satwat Hashmi, Sadia Mahmud, Mohammad Yusuf, Safia Awan, Khawar Kazmi

Section of Cardiology

Research at the Aga Khan University for several years has been directed to find a reliable, low-cost, portable, non-invasive method for identification of coronary artery disease, its location and extent. A new method has been devised to measure the magnitude and direction of cardiac electrical vectors in three perpendicular planes during physical exercise to identify reduction in myocardial excitability as the electrophysiological marker of hypoxia. This report shows that changes in electrical forces due to exercise-induced regional hypoxia serve as indicators of reversible myocardial ischaemia. Changes in the magnitude and direction of vectors at stages of the Bruce protocol were …


It’S Not Always Occam's Razor – The Case Of A Young Man With Subaortic Membrane With Superimposed Pulmonary Thromboembolism And Left Main Coronary Artery Disease, Hunaina Shahab, Abdul Baqi, Yusra Askari, Qurrat Ul Ain Aqeel, Kumail Khandwala Oct 2019

It’S Not Always Occam's Razor – The Case Of A Young Man With Subaortic Membrane With Superimposed Pulmonary Thromboembolism And Left Main Coronary Artery Disease, Hunaina Shahab, Abdul Baqi, Yusra Askari, Qurrat Ul Ain Aqeel, Kumail Khandwala

Section of Cardiology

Subaortic membrane (SAM) is a discrete fibromuscular structure which causes left ventricular outflow tract obstruction and leads to the symptomatology of valvular aortic stenosis. It is known to be associated with other congenital cardiac defects in around 30% of cases. However, it has not been associated with chronic pulmonary thromboembolism in the past. We present a case of a middle-aged Pakistani man who presented with dyspnea and hemoptysis. He was found to have a SAM and severe pulmonary hypertension on transthoracic echocardiogram. A coronary angiogram revealed non-obstructive left main coronary artery disease. A computed tomography (CT) scan chest was done …


Scintillation Event Localization In Novel Hemi-Ellipsoid Detector For Spect, Hanif R. Soysal May 2019

Scintillation Event Localization In Novel Hemi-Ellipsoid Detector For Spect, Hanif R. Soysal

LSU Master's Theses

A high sensitivity Cardiac SPECT system using hemi-ellipsoid crystals with pinhole collimation was previously proposed by Dey et al. To investigate detector resolution for this design, the scintillation light spread on a monolithic hemi-ellipsoidal CsI crystal was simulated using Geant4 Monte Carlo. The expected distribution of scintillation light on the outer surface of the crystal from photoelectric absorption events was obtained from the simulations for selected points inside the crystal. Two sets of simulations were performed. For the first set, a look-up table (LUT) of 12 points was created and each point mapped to its expected light distribution—four points at …


Progress Of In-Stent Restenosis After Vertebral Artery Ostium Stenosis And Imaging Assessments, Jingzhi Li, Md, John R. Eisenbrey, Phd, Yang Hua, Md Aug 2018

Progress Of In-Stent Restenosis After Vertebral Artery Ostium Stenosis And Imaging Assessments, Jingzhi Li, Md, John R. Eisenbrey, Phd, Yang Hua, Md

Department of Radiology Faculty Papers

Stenting has become one of the primary procedure to treat vertebral artery ostium stenosis patients. Postoperative in­stent restenosis (ISR) of the stenting is still one of the unsolved issues and requires systematic and further investigation. Through imaging assessments, ISR could be identified and evaluated in clinical practice and researches.


Going Beyond The Final Impression With Radiologic Data In The Era Of Clerical Medicine: A Case Report Of Coronary Artery Disease Found Incidentally On Computed Tomography, Andrea M. Lauffer Apr 2018

Going Beyond The Final Impression With Radiologic Data In The Era Of Clerical Medicine: A Case Report Of Coronary Artery Disease Found Incidentally On Computed Tomography, Andrea M. Lauffer

Marshall Journal of Medicine

Introduction:

Given the challenges in modern healthcare, physicians find themselves devoting a great deal of mental and emotional energy into executing the appropriate care for patients as well as performing their daily clerical duties. Many clinicians have resorted to innovative ways to minimize their tasks which often leads to narrowing the focus of a patient’s overall care and the birth of medical errors described in the Swiss cheese effect model.

Case Description:

A 66 year old male established care with a new primary care physician. Previous radiologic data revealed a pulmonary nodule that did not have appropriate follow up imaging. …


Influence Of Longitudinal Position On The Evolution Of Steady-State Signal In Cardiac Cine Balanced Steady-State Free Precession Imaging, Tyler J. Spear, Tori A. Stromp, Steve W. Leung, Moriel H. Vandsburger Nov 2017

Influence Of Longitudinal Position On The Evolution Of Steady-State Signal In Cardiac Cine Balanced Steady-State Free Precession Imaging, Tyler J. Spear, Tori A. Stromp, Steve W. Leung, Moriel H. Vandsburger

Saha Cardiovascular Research Center Faculty Publications

Background: Emerging quantitative cardiac magnetic resonance imaging (CMRI) techniques use cine balanced steady-state free precession (bSSFP) to measure myocardial signal intensity and probe underlying physiological parameters. This correlation assumes that steady-state is maintained uniformly throughout the heart in space and time.

Purpose: To determine the effects of longitudinal cardiac motion and initial slice position on signal deviation in cine bSSFP imaging by comparing two-dimensional (2D) and three-dimensional (3D) acquisitions.

Material and Methods: Nine healthy volunteers completed cardiac MRI on a 1.5-T scanner. Short axis images were taken at six slice locations using both 2D and 3D cine bSSFP. 3D acquisitions …


Ventricular Depolarisation Vectors In Exercise Induced Myocardial Ischaemia, Cameruddin W. Vellani, Mohammad Yusuf, Sadia Mahmud, Satwat Hashmi Nov 2017

Ventricular Depolarisation Vectors In Exercise Induced Myocardial Ischaemia, Cameruddin W. Vellani, Mohammad Yusuf, Sadia Mahmud, Satwat Hashmi

Section of Cardiology

Ischaemia reduces membrane excitability and conduction of myocardial depolarisation. This would alter the synergy of electromotive forces that contribute to a resultant force at any instant. Changes in magnitude and direction of resultant forces are reflected in electrocardiographic signals. Here we show a method for obtaining the coordinates of resultant electrical forces during exercise derived from a bipolar orthogonal lead system for calculation of electrical vectors in three planes. In a trial, analysis of changes in vectors indicated that the extent of reduction in magnitude with exercise was significantly greater in groups of patients categorized by impaired effort tolerance and …


Improving Cardiology Patient Flow In Nuclear Medicine, Kelly Haar, Hannah Sullivan, Kathryn Laverdiere, Nuclear Medicine Department, Haley Pelletier, Stephen Tyzik, Suneela Nayak, Ruth Hanselman Aug 2017

Improving Cardiology Patient Flow In Nuclear Medicine, Kelly Haar, Hannah Sullivan, Kathryn Laverdiere, Nuclear Medicine Department, Haley Pelletier, Stephen Tyzik, Suneela Nayak, Ruth Hanselman

MaineHealth Maine Medical Center

At baseline, a nuclear medicine department found it difficult to complete cardiac stress tests within scheduled times. Using the performance improvement process, a nuclear medicine department looked to improve patient experience related to wait times for this test.

Two goals were identified and a root cause analysis was initiated. After identifying some process issues, two KPIs were developed to address them.

A root cause analysis identified some processing issues and two KPIs were instituted to address them.

As a result, one outcome was to hire an additional physician assistant to address the barrier of inadequate cardiology coverage. Next steps include …


The Use Of Intraosseous Needles For Injection Of Contrast Media For Computed Tomographic Angiography Of The Thoracic Aorta, Michael A. Winkler, Cynthia Talley, Connor Woodward, Alexander Kingsbury, Frank Appiah, Hossam Elbelasi, Kevin P. Landwehr, Xingzhe Li, Dominik Fleischmann May 2017

The Use Of Intraosseous Needles For Injection Of Contrast Media For Computed Tomographic Angiography Of The Thoracic Aorta, Michael A. Winkler, Cynthia Talley, Connor Woodward, Alexander Kingsbury, Frank Appiah, Hossam Elbelasi, Kevin P. Landwehr, Xingzhe Li, Dominik Fleischmann

Radiology Faculty Publications

Background

The objective of this study is to evaluate the safety and quality of computed tomographic angiography of the thoracic aorta (CTA-TA) exams performed using intraosseous needle intravenous access (ION-IVA) for contrast media injection (CMI).

Methods

All CTA-TA exams at the study institution performed between 1/1/2013 and 8/14/2015 were reviewed retrospectively to identify those exams which had been performed using ION-IVA (ION-exams). ION-exams were then analyzed to determine aortic attenuation and contrast-to-noise ratio (CNR). Linear regression was used to determine how injection rate and other variables affected image quality for ION-exams. Patient electronic medical records were reviewed to identify any …


Early Gadolinium Enhancement For Area At Risk Determination: A Preclinical Validation Study, Sophia Hammer-Hansen, Steve W. Leung, Li-Yueh Hsu, Joel R. Wilson, Joni Taylor, Anders M. Greve, Jens Jakob Thune, Lars Køber, Peter Kellman, Andrew E. Arai Feb 2017

Early Gadolinium Enhancement For Area At Risk Determination: A Preclinical Validation Study, Sophia Hammer-Hansen, Steve W. Leung, Li-Yueh Hsu, Joel R. Wilson, Joni Taylor, Anders M. Greve, Jens Jakob Thune, Lars Køber, Peter Kellman, Andrew E. Arai

Internal Medicine Faculty Publications

Objectives—The aim of this study was to determine if early gadolinium enhancement (EGE) by cardiovascular magnetic resonance (CMR) imaging in a canine model of reperfused myocardial infarction depicts the area at risk (AAR) as determined by microsphere blood flow analysis.

Background—It remains controversial whether only the irreversibly injured myocardium enhances when performing CMR imaging in the setting of acute myocardial infarction. Recently, EGE has been proposed as a measure of the AAR in acute myocardial infarction as it correlates well with T2-weighted imaging of the AAR, but still requires pathological validation.

Methods—Eleven dogs underwent 2 hours of …


Validation, Optimization, And Image Processing Of Spiral Cine Dense Magnetic Resonance Imaging For The Quantification Of Left And Right Ventricular Mechanics, Gregory J. Wehner Jan 2017

Validation, Optimization, And Image Processing Of Spiral Cine Dense Magnetic Resonance Imaging For The Quantification Of Left And Right Ventricular Mechanics, Gregory J. Wehner

Theses and Dissertations--Biomedical Engineering

Recent evidence suggests that cardiac mechanics (e.g. cardiac strains) are better measures of heart function compared to common clinical metrics like ejection fraction. However, commonly-used parameters of cardiac mechanics remain limited to just a few measurements averaged over the whole left ventricle. We hypothesized that recent advances in cardiac magnetic resonance imaging (MRI) could be extended to provide measures of cardiac mechanics throughout the left and right ventricles (LV and RV, respectively).

Displacement Encoding with Stimulated Echoes (DENSE) is a cardiac MRI technique that has been validated for measuring LV mechanics at a magnetic field strength of 1.5 T but …


Cardiac Chemical Exchange Saturation Transfer Mr Imaging Tracking Of Cell Survival Or Rejection In Mouse Models Of Cell Therapy, Ashley L. Pumphrey, Shaojing Ye, Zhengshi Yang, Jennifer Simkin, John C. Gensel, Ahmed Abdel-Latif, Moriel H. Vandsburger Jan 2017

Cardiac Chemical Exchange Saturation Transfer Mr Imaging Tracking Of Cell Survival Or Rejection In Mouse Models Of Cell Therapy, Ashley L. Pumphrey, Shaojing Ye, Zhengshi Yang, Jennifer Simkin, John C. Gensel, Ahmed Abdel-Latif, Moriel H. Vandsburger

Saha Cardiovascular Research Center Faculty Publications

Purpose:

To examine whether cardiac chemical exchange saturation transfer (CEST) imaging can be serially and noninvasively used to probe cell survival or rejection after intramyocardial implantation in mice.

Materials and Methods:

Experiments were compliant with the National Institutes of Health Guidelines on the Use of Laboratory Animals and approved by the Institutional Animal Care and Use Committee. One million C2C12 cells labeled with either europium (Eu) 10-(2-hydroxypropyl)-1,4,7-tetraazacyclododecane-1,4,7-triacetic acid (HP-DO3A) or saline via the hypotonic swelling technique were implanted into the anterior-lateral left ventricular wall in C57BL/6J (allogeneic model, n = 17) and C3H (syngeneic model, n = 13) mice. Imaging …


Properties And Optimization Of Respiratory Navigator Gating For Spiral Cine Dense Cardiac Mri, Sean Michael Hamlet Jan 2017

Properties And Optimization Of Respiratory Navigator Gating For Spiral Cine Dense Cardiac Mri, Sean Michael Hamlet

Theses and Dissertations--Electrical and Computer Engineering

Cardiac magnetic resonance (MR) imaging can non-invasively assess heart function. Displacement encoding with stimulated echoes (DENSE) is an advanced cardiac MR imaging technique that measures tissue displacement and can be used to quantify cardiac mechanics (e.g. strain and torsion). When combined with clinical risk factors, cardiac mechanics have been shown to be better predictors of mortality than traditional measures of heart function.

End-expiratory breath-holds are typically used to minimize respiratory motion artifacts. Unfortunately, requiring subjects to breath-hold introduces limitations with the duration of image acquisition and quality of data acquired, especially in patients with limited ability to hold their breath. …


Proceedings Of 2016 Aurora Scientific Day Nov 2016

Proceedings Of 2016 Aurora Scientific Day

Journal of Patient-Centered Research and Reviews

This supplement includes select abstracts presented at the 42nd annual Aurora Scientific Day research symposium, held May 25, 2016, in Milwaukee, Wisconsin. Aurora Scientific Day provides a forum for original research conducted by faculty, fellows, residents, students and other allied health professionals affiliated with Aurora Health Care, a not-for-profit health system comprised of integrated hospitals and clinics across eastern Wisconsin and northeastern Illinois.


Task Force 2: Pediatric Cardiology Fellowship Training In Noninvasive Cardiac Imaging., Shubhika Srivastava, Beth F. Printz, Tal Geva, Girish S. Shirali, Paul M. Weinberg, Pierre C. Wong, Peter Lang Aug 2015

Task Force 2: Pediatric Cardiology Fellowship Training In Noninvasive Cardiac Imaging., Shubhika Srivastava, Beth F. Printz, Tal Geva, Girish S. Shirali, Paul M. Weinberg, Pierre C. Wong, Peter Lang

Manuscripts, Articles, Book Chapters and Other Papers

No abstract provided.


Task Force 2: Pediatric Cardiology Fellowship Training In Noninvasive Cardiac Imaging. Spctpd/Acc/Aap/Aha., Shubhika Srivastava, Beth F Printz, Tal Geva, Girish S. Shirali, Paul M Weinberg, Pierre C Wong, Peter Lang, Society Of Pediatric Cardiology Training Program Directors, American College Of Cardiology, American Academy Of Pediatrics, American Heart Association Aug 2015

Task Force 2: Pediatric Cardiology Fellowship Training In Noninvasive Cardiac Imaging. Spctpd/Acc/Aap/Aha., Shubhika Srivastava, Beth F Printz, Tal Geva, Girish S. Shirali, Paul M Weinberg, Pierre C Wong, Peter Lang, Society Of Pediatric Cardiology Training Program Directors, American College Of Cardiology, American Academy Of Pediatrics, American Heart Association

Manuscripts, Articles, Book Chapters and Other Papers

No abstract provided.


Cost-Effectiveness Of Coronary Artery Calcium Testing For Coronary Heart And Cardiovascular Disease Risk Prediction To Guide Statin Allocation: The Multi-Ethnic Study Of Atherosclerosis (Mesa), Khurram Nasir Mar 2015

Cost-Effectiveness Of Coronary Artery Calcium Testing For Coronary Heart And Cardiovascular Disease Risk Prediction To Guide Statin Allocation: The Multi-Ethnic Study Of Atherosclerosis (Mesa), Khurram Nasir

All Publications

BACKGROUND: The Multi-Ethnic Study of Atherosclerosis (MESA) showed that the addition of coronary artery calcium (CAC) to traditional risk factors improves risk classification, particularly in intermediate risk asymptomatic patients with LDL cholesterol levels /dL. However, the cost-effectiveness of incorporating CAC into treatment decision rules has yet to be clearly delineated.OBJECTIVE: To model the cost-effectiveness of CAC for cardiovascular risk stratification in asymptomatic, intermediate risk patients not taking a statin. Treatment based on CAC was compared to (1) treatment of all intermediate-risk patients, and (2) treatment on the basis of United States guidelines.METHODS: We developed a Markov model of first coronary …


Is Metabolic Syndrome Predictive Of Prevalence, Extent, And Risk Of Coronary Artery Disease Beyond Its Components? Results From The Multinational Coronary Ct Angiography Evaluation For Clinical Outcome: An International Multicenter Registry (Confirm), Ricardo Cury Mar 2015

Is Metabolic Syndrome Predictive Of Prevalence, Extent, And Risk Of Coronary Artery Disease Beyond Its Components? Results From The Multinational Coronary Ct Angiography Evaluation For Clinical Outcome: An International Multicenter Registry (Confirm), Ricardo Cury

All Publications

No abstract provided.


Promoting Comfort During Ct-Coronary Angiogram, Margo Archer, Dawn Arevalo, Kelly Vazquez Jan 2015

Promoting Comfort During Ct-Coronary Angiogram, Margo Archer, Dawn Arevalo, Kelly Vazquez

All Publications

No abstract provided.


Characterization And Normal Measurements Of The Left Ventricular Outflow Tract By Ecg-Gated Cardiac Ct: Implications For Disorders Of The Outflow Tract And Aortic Valve., Ethan J Halpern, Shiva Gupta, David J Halpern, David H Wiener, Alyson N Owen Oct 2012

Characterization And Normal Measurements Of The Left Ventricular Outflow Tract By Ecg-Gated Cardiac Ct: Implications For Disorders Of The Outflow Tract And Aortic Valve., Ethan J Halpern, Shiva Gupta, David J Halpern, David H Wiener, Alyson N Owen

Department of Radiology Faculty Papers

RATIONALE AND OBJECTIVES: Studies suggest that electrocardiographically gated coronary computed tomographic angiography provides a clear definition of the left ventricular outflow tract (LVOT), and normal LVOT morphology may not be round, as assumed when the continuity equation is applied during echocardiography. The aims of this study were to demonstrate the morphology of the LVOT on coronary computed tomographic angiography and to establish normal values for LVOT measurements.

MATERIALS AND METHODS: Two independent readers retrospectively measured anterior-posterior (AP) and transverse diameters of the LVOT and performed LVOT planimetry on coronary computed tomographic angiographic studies of 106 consecutive patients with normal aortic …


Infectious Intracranial Aneurysms: Collaboration For Treatment Success, Erin M. Conahan Rn, Bsn, Cnrn Jan 2012

Infectious Intracranial Aneurysms: Collaboration For Treatment Success, Erin M. Conahan Rn, Bsn, Cnrn

Patient Care Services / Nursing

No abstract provided.


Carotid Artery Disease In Patients Undergoing Elective Coronary Artery Bypass Surgery, Waseem Akhtar, Ayan Sabih, Arif Ali, Mubashir Aslam, Nadeem Ahmad Dec 2009

Carotid Artery Disease In Patients Undergoing Elective Coronary Artery Bypass Surgery, Waseem Akhtar, Ayan Sabih, Arif Ali, Mubashir Aslam, Nadeem Ahmad

Department of Radiology

OBJECTIVE: To determine frequency of carotid artery disease in patients undergoing elective coronary artery bypass grafting (CABG) using Doppler sonography.STUDY DESIGN: Observational study.

PLACE AND DURATION OF STUDY: Radiology Department, The Aga Khan University Hospital, Karachi, from January 2005 to September 2008.

METHODOLOGY: Patients with known cardiovascular disease waiting for CABG surgery were enrolled for carotid artery Doppler sonography. A predefined data entry form was used for data collection. Coronary angiography findings, carotid artery findings and other associated factors were noted from medical and radiological records. Frequency and pattern of carotid artery disease along with associated risk factors were evaluated. …


Sir/Rsna/Cirse Joint Medical Simulation Task Force Strategic Plan: Executive Summary, Derek Gould, Aalpen Patel, Gary Becker, Buddy Conners, John Cardella, Steven Dawson, Craig Glaiberman, David Kessel, Mick Lee, Mark Scerbo Jan 2007

Sir/Rsna/Cirse Joint Medical Simulation Task Force Strategic Plan: Executive Summary, Derek Gould, Aalpen Patel, Gary Becker, Buddy Conners, John Cardella, Steven Dawson, Craig Glaiberman, David Kessel, Mick Lee, Mark Scerbo

Psychology Faculty Publications

(First paragraph) The Executive Councils of the Society of Interventional Radiology (SIR), Radiological Society of North America (RSNA), and Cardiovascular and Interventional Radiological Society of Europe (CIRSE) have charged their Medical Simulation Task Forces and Work Groups to cooperate to achieve excellence and safety in interventional radiology patient care by jointly recommending and guiding implementation of a robust infrastructure and process to support Interventional Radiology (IR) simulation development, assessment, validation, application, and dissemination.