Open Access. Powered by Scholars. Published by Universities.®
- Discipline
- Institution
- Publication Year
Articles 31 - 39 of 39
Full-Text Articles in Medical Biophysics
Chronic Obstructive Pulmonary Disease: Quantification Of Bronchodilator Effects By Using Hyperpolarized ³He Mr Imaging, Miranda Kirby, Lindsay Mathew, Mohammadreza Heydarian, Roya Etemad-Rezai, David G Mccormack, Grace Parraga
Chronic Obstructive Pulmonary Disease: Quantification Of Bronchodilator Effects By Using Hyperpolarized ³He Mr Imaging, Miranda Kirby, Lindsay Mathew, Mohammadreza Heydarian, Roya Etemad-Rezai, David G Mccormack, Grace Parraga
Medical Biophysics Publications
PURPOSE: To evaluate short-acting bronchodilator effects in chronic obstructive pulmonary disease (COPD) by using hyperpolarized helium 3 (³He) magnetic resonance (MR) imaging, spirometry, and plethysmography.
MATERIALS AND METHODS: Fourteen ex-smokers with COPD provided written informed consent to a local ethics board-approved and Health Insurance and Portability Accountability Act-compliant protocol and underwent hyperpolarized ³He and hydrogen 1 MR imaging, spirometry, and plethysmography before and a mean of 25 minutes ± 2 (standard deviation) after administration of 400 μg salbutamol. Distribution of ³He gas was evaluated by using semiautomated segmentation of ³He voxel intensities, where cluster 1 represented regions of signal void …
Hyperpolarized (3)He Magnetic Resonance Imaging-Derived Pulmonary Pressure-Volume Curves, Stephen Choy, Andrew Wheatley, David G Mccormack, Grace Parraga
Hyperpolarized (3)He Magnetic Resonance Imaging-Derived Pulmonary Pressure-Volume Curves, Stephen Choy, Andrew Wheatley, David G Mccormack, Grace Parraga
Medical Biophysics Publications
We aimed to evaluate the potential for the use of hyperpolarized helium-3 magnetic resonance imaging (MRI) apparent diffusion coefficient (ADC) surrogates of alveolar size, together with literature-based morphological parameters in a theoretical model of lung mechanics to simulate noninvasive transpulmonary pressure-volume curves. Fourteen ex-smokers with chronic obstructive pulmonary disease (COPD) (n = 8 stage II, n = 6 stage III/IV COPD) and five age-matched never-smokers, provided written, informed consent and were evaluated at baseline and 26 + or - 2 mo later (n = 15 subjects) using plethysmography, spirometry, and (3)He MRI at 3.0 T. Total lung capacity, residual volume, …
Chronic Obstructive Pulmonary Disease: Longitudinal Hyperpolarized (3)He Mr Imaging, Miranda Kirby, Lindsay Mathew, Andrew Wheatley, Giles E Santyr, David G Mccormack, Grace Parraga
Chronic Obstructive Pulmonary Disease: Longitudinal Hyperpolarized (3)He Mr Imaging, Miranda Kirby, Lindsay Mathew, Andrew Wheatley, Giles E Santyr, David G Mccormack, Grace Parraga
Medical Biophysics Publications
PURPOSE: To quantitatively evaluate a small pilot group of ex-smokers with chronic obstructive pulmonary disease (COPD) and healthy volunteers during approximately 2 years by using hyperpolarized helium 3 ((3)He) magnetic resonance (MR) imaging.
MATERIALS AND METHODS: All subjects provided written informed consent to the study protocol, which was approved by the local research ethics board and Health Canada and was compliant with the Personal Information Protection and Electronic Documents Act and HIPAA. Hyperpolarized (3)He MR imaging, hydrogen 1 MR imaging, spirometry, and plethysmography were performed in 15 ex-smokers with COPD and five healthy volunteers (with the same mean age and …
Schedule For Ct Image Guidance In Treating Prostate Cancer With Helical Tomotherapy., G Beldjoudi, S Yartsev, G Bauman, Jerry J. Battista Dr., Jacob Van Dyk
Schedule For Ct Image Guidance In Treating Prostate Cancer With Helical Tomotherapy., G Beldjoudi, S Yartsev, G Bauman, Jerry J. Battista Dr., Jacob Van Dyk
Oncology Publications
The aim of this study was to determine the effect of reducing the number of image guidance sessions and patient-specific target margins on the dose distribution in the treatment of prostate cancer with helical tomotherapy. 20 patients with prostate cancer who were treated with helical tomotherapy using daily megavoltage CT (MVCT) imaging before treatment served as the study population. The average geometric shifts applied for set-up corrections, as a result of co-registration of MVCT and planning kilovoltage CT studies over an increasing number of image guidance sessions, were determined. Simulation of the consequences of various imaging scenarios on the dose …
Scan-Rescan And Intra-Observer Variability Of Magnetic Resonance Imaging Of Carotid Atherosclerosis At 1.5 T And 3.0 T, Arvin Vidal, Yves Bureau, Trevor Wade, J David Spence, Brian K Rutt, Aaron Fenster, Grace Parraga
Scan-Rescan And Intra-Observer Variability Of Magnetic Resonance Imaging Of Carotid Atherosclerosis At 1.5 T And 3.0 T, Arvin Vidal, Yves Bureau, Trevor Wade, J David Spence, Brian K Rutt, Aaron Fenster, Grace Parraga
Medical Biophysics Publications
Carotid atherosclerosis measurements for eight subjects at baseline and 14 +/- 2 days later were examined using 1.5 T and 3.0 T magnetic resonance imaging (MRI). A single observer blinded to field strength, subject and timepoint manually segmented carotid artery wall and lumen boundaries in randomized images in five measurement trials. Mean increases in the signal-to-noise ratios (SNR) for T1-weighted images acquired at 3.0 T compared to 1.5 T were 90% (scan) and 80% (rescan). Despite significantly improved SNR and contrast-to-noise ratios (CNR) for images acquired at 3.0 T, vessel wall volume (VWV) intra-observer variability was not significantly different using …
Consistency Check Of Planned Adaptive Option On Helical Tomotherapy., M Schirm, S Yartsev, G Bauman, Jerry J. Battista Dr., Jacob Van Dyk
Consistency Check Of Planned Adaptive Option On Helical Tomotherapy., M Schirm, S Yartsev, G Bauman, Jerry J. Battista Dr., Jacob Van Dyk
Oncology Publications
This study aims to evaluate a new Planned Adaptive software (TomoTherapy Inc., Madison, WI) of the helical tomotherapy system by retrospective verification and adaptive re-planning of radiation treatment. Four patients with different disease sites (brain, nasal cavity, lungs, prostate) were planned in duplicate using the diagnostic planning kVCT data set and MVCT studies of the first treatment fraction with the same optimization parameters for both plan types. The dosimetric characteristics of minimum, maximum, and mean dose to the targets as well as to organs at risk were compared. Both sets of plans were used for calculation of dose distributions in …
Mapping And Quantifying Hyperpolarized 3he Magnetic Resonance Imaging Apparent Diffusion Coefficient Gradients, Andrea Evans, David G Mccormack, Giles Santyr, Grace Parraga
Mapping And Quantifying Hyperpolarized 3he Magnetic Resonance Imaging Apparent Diffusion Coefficient Gradients, Andrea Evans, David G Mccormack, Giles Santyr, Grace Parraga
Medical Biophysics Publications
We measured hyperpolarized 3He magnetic resonance imaging (MRI) apparent diffusion coefficients (ADC) and quantified ADC gradients in each three-by-three voxel region of interest (ROI). Such local ADC gradients can be represented in vector maps showing the magnitude (|G3x3|) and direction of ADC gradients, providing a qualitative visualization tool and quantitative measurement of airway and air space heterogeneity. Twenty-four subjects (15 male, mean age=67+/-7 yr) with global initiative for chronic obstructive lung disease (GOLD) stage II (n=9, mean age 68+/-6 yr), GOLD stage III chronic obstructive pulmonary disease (COPD; n=7, mean age 67+/-8 yr), and age-matched healthy volunteers (n=8, mean age …
Quantification Of Carotid Vessel Wall And Plaque Thickness Change Using 3d Ultrasound Images, Bernard Chiu, Micaela Egger, J David Spence, Grace Parraga, Aaron Fenster
Quantification Of Carotid Vessel Wall And Plaque Thickness Change Using 3d Ultrasound Images, Bernard Chiu, Micaela Egger, J David Spence, Grace Parraga, Aaron Fenster
Medical Biophysics Publications
Quantitative measurements of carotid plaque burden progression or regression are important in monitoring patients and in evaluation of new treatment options. 3D ultrasound (US) has been used to monitor the progression or regression of carotid artery plaques. This paper reports on the development and application of a method used to analyze changes in carotid plaque morphology from 3D US. The technique used is evaluated using manual segmentations of the arterial wall and lumen from 3D US images acquired in two imaging sessions. To reduce the effect of segmentation variability, segmentation was performed five times each for the wall and lumen. …
Adaptive Radiotherapy Planning On Decreasing Gross Tumor Volumes As Seen On Megavoltage Computed Tomography Images., Curtis Woodford, Slav Yartsev, R. Dar, Glenn Bauman, Jacob Van Dyk
Adaptive Radiotherapy Planning On Decreasing Gross Tumor Volumes As Seen On Megavoltage Computed Tomography Images., Curtis Woodford, Slav Yartsev, R. Dar, Glenn Bauman, Jacob Van Dyk
Oncology Publications
PURPOSE: To evaluate gross tumor volume (GTV) changes for patients with non-small-cell lung cancer by using daily megavoltage (MV) computed tomography (CT) studies acquired before each treatment fraction on helical tomotherapy and to relate the potential benefit of adaptive image-guided radiotherapy to changes in GTV.
METHODS AND MATERIALS: Seventeen patients were prescribed 30 fractions of radiotherapy on helical tomotherapy for non-small-cell lung cancer at London Regional Cancer Program from Dec 2005 to March 2007. The GTV was contoured on the daily MVCT studies of each patient. Adapted plans were created using merged MVCT-kilovoltage CT image sets to investigate the advantages …