Open Access. Powered by Scholars. Published by Universities.®
Articles 1 - 8 of 8
Full-Text Articles in Medical Biophysics
Hyperpolarized Helium 3 Mri In Mild-To-Moderate Asthma: Prediction Of Postbronchodilator Reversibility, Rachel L Eddy, Sarah Svenningsen, Christopher Licskai, David G Mccormack, Grace Parraga
Hyperpolarized Helium 3 Mri In Mild-To-Moderate Asthma: Prediction Of Postbronchodilator Reversibility, Rachel L Eddy, Sarah Svenningsen, Christopher Licskai, David G Mccormack, Grace Parraga
Medical Biophysics Publications
Background: Longitudinal progression to irreversible airflow limitation occurs in approximately 10% of patients with asthma, but it is difficult to identify patients who are at risk for this transition.
Purpose: To investigate 6-year longitudinal changes in hyperpolarized helium 3 (3He) MRI ventilation defects in study participants with mild-to-moderate asthma and identify predictors of longitudinal changes in postbronchodilator forced expiratory volume in 1 second (FEV1) reversibility
Materials and Methods: Spirometry and hyperpolarized 3He MRI were evaluated in participants with mild-to-moderate asthma in two prospectively planned visits approximately 6 years apart. Participants underwent methacholine challenge at baseline (January 2010 to April 2011) …
Hyperpolarized 3he Mri Ventilatory Apparent Diffusion Coefficient Of Alpha-1 Antitrypsin, Andrew Westcott, Dante P I Capaldi, Alexei Ouriadov, David G Mccormack, Grace Parraga
Hyperpolarized 3he Mri Ventilatory Apparent Diffusion Coefficient Of Alpha-1 Antitrypsin, Andrew Westcott, Dante P I Capaldi, Alexei Ouriadov, David G Mccormack, Grace Parraga
Medical Biophysics Publications
Alpha-1 antitrypsin deficiency (AATD) leads to disabling chronic obstructive pulmonary disease (COPD). Current therapy aimed at slowing lung disease progression includes exogenous alpha-1 antitrypsin augmentation therapy, but there are few potential new treatments under development. Currently used measurements of AATD-related emphysema include the forced expiratory volume in 1 second (FEV1) and the diffusing capacity of carbon monoxide (DLCO); both are relatively insensitive to therapy, although computed tomography (CT) lung density measurements have been shown to worsen more slowly in treated patients.
Hyperpolarized 3he Magnetic Resonance Imaging Ventilation Defects In Asthma: Relationship To Airway Mechanics, Del Leary, Sarah Svenningsen, Fumin Guo, Swati Bhatawadekar, Grace Parraga, Geoffrey N Maksym
Hyperpolarized 3he Magnetic Resonance Imaging Ventilation Defects In Asthma: Relationship To Airway Mechanics, Del Leary, Sarah Svenningsen, Fumin Guo, Swati Bhatawadekar, Grace Parraga, Geoffrey N Maksym
Medical Biophysics Publications
In patients with asthma, magnetic resonance imaging (MRI) provides direct measurements of regional ventilation heterogeneity, the etiology of which is not well-understood, nor is the relationship of ventilation abnormalities with lung mechanics. In addition, respiratory resistance and reactance are often abnormal in asthmatics and the frequency dependence of respiratory resistance is thought to reflect ventilation heterogeneity. We acquiredMRIventilation defect maps, forced expiratory volume in one-second (FEV1), and airways resistance (Raw) measurements, and used a computational airway model to explore the relationship of ventilation defect percent (VDP) with simulated measurements of respiratory system resistance (Rrs) and reactance (Xrs).MRIventilation defect maps were …
Pulmonary Ct And Mri Phenotypes That Help Explain Chronic Pulmonary Obstruction Disease Pathophysiology And Outcomes, Eric A Hoffman, David A Lynch, R Graham Barr, Edwin J R Van Beek, Grace Parraga
Pulmonary Ct And Mri Phenotypes That Help Explain Chronic Pulmonary Obstruction Disease Pathophysiology And Outcomes, Eric A Hoffman, David A Lynch, R Graham Barr, Edwin J R Van Beek, Grace Parraga
Medical Biophysics Publications
Pulmonary x-ray computed tomographic (CT) and magnetic resonance imaging (MRI) research and development has been motivated, in part, by the quest to subphenotype common chronic lung diseases such as chronic obstructive pulmonary disease (COPD). For thoracic CT and MRI, the main COPD research tools, disease biomarkers are being validated that go beyond anatomy and structure to include pulmonary functional measurements such as regional ventilation, perfusion, and inflammation. In addition, there has also been a drive to improve spatial and contrast resolution while at the same time reducing or eliminating radiation exposure. Therefore, this review focuses on our evolving understanding of …
Hyperpolarized 3he And 129xe Mr Imaging In Healthy Volunteers And Patients With Chronic Obstructive Pulmonary Disease, Miranda Kirby, Sarah Svenningsen, Amir Owrangi, Andrew Wheatley, Adam Farag, Alexei Ouriadov, Giles E Santyr, Roya Etemad-Rezai, Harvey O Coxson, David G Mccormack, Grace Parraga
Hyperpolarized 3he And 129xe Mr Imaging In Healthy Volunteers And Patients With Chronic Obstructive Pulmonary Disease, Miranda Kirby, Sarah Svenningsen, Amir Owrangi, Andrew Wheatley, Adam Farag, Alexei Ouriadov, Giles E Santyr, Roya Etemad-Rezai, Harvey O Coxson, David G Mccormack, Grace Parraga
Medical Biophysics Publications
PURPOSE: To quantitatively compare hyperpolarized helium 3 (3He) and xenon 129 (129Xe) magnetic resonance (MR) images obtained within 5 minutes in healthy volunteers and patients with chronic obstructive pulmonary disease (COPD) and to evaluate the correlations between 3He and 129Xe MR imaging measurements and those from spirometry and plethysmography.
MATERIALS AND METHODS: This study was approved by an ethics board and compliant with HIPAA. Written informed consent was obtained from all subjects. Eight healthy volunteers and 10 patients with COPD underwent MR imaging, spirometry, and plethysmography. Ventilation defect percentages (VDPs) at 3He and 129Xe imaging were obtained by using semiautomated …
Evaluating Bronchodilator Effects In Chronic Obstructive Pulmonary Disease Using Diffusion-Weighted Hyperpolarized Helium-3 Magnetic Resonance Imaging, Miranda Kirby, Mohammadreza Heydarian, Andrew Wheatley, David G Mccormack, Grace Parraga
Evaluating Bronchodilator Effects In Chronic Obstructive Pulmonary Disease Using Diffusion-Weighted Hyperpolarized Helium-3 Magnetic Resonance Imaging, Miranda Kirby, Mohammadreza Heydarian, Andrew Wheatley, David G Mccormack, Grace Parraga
Medical Biophysics Publications
The objective of this study was to evaluate the regional effects of bronchodilator administration in chronic obstructive pulmonary disease (COPD) using hyperpolarized helium-3 ((3)He) MRI apparent diffusion coefficient (ADC). Ten COPD ex-smokers provided written, informed consent and underwent diffusion-weighted, hyperpolarized (3)He MRI, spirometry, and plethysmography before and 25 ± 2 min after bronchodilator administration. Pre- and postsalbutamol whole-lung (WL) ADC maps were generated and registered together to identify the lung regions containing the (3)He signal at both time points, and mean ADC within those regions of interest (ROI) was determined for a measurement of previously ventilated ROI ADC (ADC(P)). Lung …
Chronic Obstructive Pulmonary Disease: Quantification Of Bronchodilator Effects By Using Hyperpolarized ³He Mr Imaging, Miranda Kirby, Lindsay Mathew, Mohammadreza Heydarian, Roya Etemad-Rezai, David G Mccormack, Grace Parraga
Chronic Obstructive Pulmonary Disease: Quantification Of Bronchodilator Effects By Using Hyperpolarized ³He Mr Imaging, Miranda Kirby, Lindsay Mathew, Mohammadreza Heydarian, Roya Etemad-Rezai, David G Mccormack, Grace Parraga
Medical Biophysics Publications
PURPOSE: To evaluate short-acting bronchodilator effects in chronic obstructive pulmonary disease (COPD) by using hyperpolarized helium 3 (³He) magnetic resonance (MR) imaging, spirometry, and plethysmography.
MATERIALS AND METHODS: Fourteen ex-smokers with COPD provided written informed consent to a local ethics board-approved and Health Insurance and Portability Accountability Act-compliant protocol and underwent hyperpolarized ³He and hydrogen 1 MR imaging, spirometry, and plethysmography before and a mean of 25 minutes ± 2 (standard deviation) after administration of 400 μg salbutamol. Distribution of ³He gas was evaluated by using semiautomated segmentation of ³He voxel intensities, where cluster 1 represented regions of signal void …
Imaging Of Lung Function Using Hyperpolarized Helium-3 Magnetic Resonance Imaging: Review Of Current And Emerging Translational Methods And Applications, Sean Fain, Mark L Schiebler, David G Mccormack, Grace Parraga
Imaging Of Lung Function Using Hyperpolarized Helium-3 Magnetic Resonance Imaging: Review Of Current And Emerging Translational Methods And Applications, Sean Fain, Mark L Schiebler, David G Mccormack, Grace Parraga
Medical Biophysics Publications
During the past several years there has been extensive development and application of hyperpolarized helium-3 (HP (3)He) magnetic resonance imaging (MRI) in clinical respiratory indications such as asthma, chronic obstructive pulmonary disease, cystic fibrosis, radiation-induced lung injury, and transplantation. This review focuses on the state-of-the-art of HP (3)He MRI and its application to clinical pulmonary research. This is not an overview of the physics of the method, as this topic has been covered previously. We focus here on the potential of this imaging method and its challenges in demonstrating new types of information that has the potential to influence clinical …