Articles 1 - 12 of 12

Full-Text Articles in Medical Biophysics

Development Of Low Frequency Electron Paramagnetic Resonance Methods And Instrumentation For Biological Applications, Laura A. Buchanan Jan 2018

Development Of Low Frequency Electron Paramagnetic Resonance Methods And Instrumentation For Biological Applications, Laura A. Buchanan

Electronic Theses and Dissertations

EPR is a powerful biophysical tool that can be used to measure tumor physiology. With the addition of magnetic field gradients, the spectral properties of paramagnetic species can be mapped. To facilitate EPR imaging, methods and instrumentation at frequencies between 250 MHz and 1 GHz were developed.

At low spin concentrations, the rapid scan background signal is often many times larger than the EPR signal of interest. To help remove the background contribution, a data acquisition procedure that takes advantage of a cross-loop resonator and bipolar power supplies was developed at 250 MHz. In this procedure, two scans are collected. …


Design And Evaluation Of An Mri-Compatible Linear Motion Stage., Mohammad Ali Tavallaei, Patricia M Johnson, Junmin Liu, Maria Drangova Jan 2016

Design And Evaluation Of An Mri-Compatible Linear Motion Stage., Mohammad Ali Tavallaei, Patricia M Johnson, Junmin Liu, Maria Drangova

Medical Biophysics Publications

PURPOSE: To develop and evaluate a tool for accurate, reproducible, and programmable motion control of imaging phantoms for use in motion sensitive magnetic resonance imaging (MRI) appli cations.

METHODS: In this paper, the authors introduce a compact linear motion stage that is made of nonmagnetic material and is actuated with an ultrasonic motor. The stage can be positioned at arbitrary positions and orientations inside the scanner bore to move, push, or pull arbitrary phantoms. Using optical trackers, measuring microscopes, and navigators, the accuracy of the stage in motion control was evaluated. Also, the effect of the stage on image signal-to-noise …


Characterization Of Low Density Intracranial Lesions Using Dual-Energy Computed To Mography, Jessica L. Nute May 2015

Characterization Of Low Density Intracranial Lesions Using Dual-Energy Computed To Mography, Jessica L. Nute

Dissertations and Theses (Open Access)

Calcific and hemorrhagic foci of susceptibility are frequently encountered on routine brain MR studies. Both etiologies cause variations in local magnetic field strength, leading to dark regions on the MR images that cannot be classified. Single-energy CT (SECT) can be used to identify lesions with attenuation over 100 HU as calcific, however lesions with lower attenuation cannot be reliably identified. While calcific lesions are unlikely to cause harm, hemorrhagic lesions carry a risk of subsequent intracranial bleeding; as such, identification of hemorrhage is vital in preventing the inappropriate use of anticoagulant medications in patients with hemorrhagic lesions.

Given there currently …


Three-Dimensional Carotid Ultrasound Plaque Texture Predicts Vascular Events, Arna Van Engelen, Thapat Wannarong, Grace Parraga, Wiro J Niessen, Aaron Fenster, J David Spence, Marleen De Bruijne Jul 2014

Three-Dimensional Carotid Ultrasound Plaque Texture Predicts Vascular Events, Arna Van Engelen, Thapat Wannarong, Grace Parraga, Wiro J Niessen, Aaron Fenster, J David Spence, Marleen De Bruijne

Medical Biophysics Publications

BACKGROUND AND PURPOSE: Carotid ultrasound atherosclerosis measurements, including those of the arterial wall and plaque, provide a way to monitor patients at risk of vascular events. Our objective was to examine carotid ultrasound plaque texture measurements and the change in carotid plaque texture during 1 year in patients at risk of events and to compare these with measurements of plaque volume and other risk factors as predictors of vascular events.

METHODS: We evaluated 298 patients with carotid atherosclerosis using 3-dimensional (3D) ultrasound at baseline and after 1 year and measured carotid plaque volume and 376 measures of plaque texture. Patients …


Three-Dimensional Segmentation Of Three-Dimensional Ultrasound Carotid Atherosclerosis Using Sparse Field Level Sets., E Ukwatta, J Yuan, D Buchanan, B Chiu, J Awad, W Qiu, G Parraga, A Fenster May 2013

Three-Dimensional Segmentation Of Three-Dimensional Ultrasound Carotid Atherosclerosis Using Sparse Field Level Sets., E Ukwatta, J Yuan, D Buchanan, B Chiu, J Awad, W Qiu, G Parraga, A Fenster

Medical Biophysics Publications

PURPOSE: Three-dimensional ultrasound (3DUS) vessel wall volume (VWV) provides a 3D measurement of carotid artery wall remodeling and atherosclerotic plaque and is sensitive to temporal changes of carotid plaque burden. Unfortunately, although 3DUS VWV provides many advantages compared to measurements of arterial wall thickening or plaque alone, it is still not widely used in research or clinical practice because of the inordinate amount of time required to train observers and to generate 3DUS VWV measurements. In this regard, semiautomated methods for segmentation of the carotid media-adventitia boundary (MAB) and the lumen-intima boundary (LIB) would greatly improve the time to train …


A Magnetic-Resonance-Imaging-Compatible Remote Catheter Navigation System., Mohammad Ali Tavallaei, Yogesh Thakur, Syed Haider, Maria Drangova Apr 2013

A Magnetic-Resonance-Imaging-Compatible Remote Catheter Navigation System., Mohammad Ali Tavallaei, Yogesh Thakur, Syed Haider, Maria Drangova

Medical Biophysics Publications

A remote catheter navigation system compatible with magnetic resonance imaging (MRI) has been developed to facilitate MRI-guided catheterization procedures. The interventionalist's conventional motions (axial motion and rotation) on an input catheter - acting as the master - are measured by a pair of optical encoders, and a custom embedded system relays the motions to a pair of ultrasonic motors. The ultrasonic motors drive the patient catheter (slave) within the MRI scanner, replicating the motion of the input catheter. The performance of the remote catheter navigation system was evaluated in terms of accuracy and delay of motion replication outside and within …


The Effects Of Field-Of-View And Patient Size On Ct Numbers From Cone-Beam Computed Tomography., Katrina Y T Seet, Arvand Barghi, Slav Yartsev, Jacob Van Dyk Oct 2009

The Effects Of Field-Of-View And Patient Size On Ct Numbers From Cone-Beam Computed Tomography., Katrina Y T Seet, Arvand Barghi, Slav Yartsev, Jacob Van Dyk

Oncology Publications

Cone-beam computed tomography (CBCT) is used for patient alignment before treatment and is ideal for use in adaptive radiotherapy to account for tumor shrinkage, organ deformation and weight loss. However, CBCT images are prone to artifacts such as streaking and cupping effects, reducing image quality and CT number accuracy. Our goal was to determine the optimum combination of cone-beam imaging options to increase the accuracy of image CT numbers. Several phantoms with and without inserts of known relative electron densities were imaged using the Varian on-board imaging system. It was found that CT numbers are most influenced by the selection …


Analysis Of Carotid Lumen Surface Morphology Using Three-Dimensional Ultrasound Imaging, Bernard Chiu, Vadim Beletsky, J David Spence, Grace Parraga, Aaron Fenster Mar 2009

Analysis Of Carotid Lumen Surface Morphology Using Three-Dimensional Ultrasound Imaging, Bernard Chiu, Vadim Beletsky, J David Spence, Grace Parraga, Aaron Fenster

Medical Biophysics Publications

Carotid plaque surface irregularity and ulcerations play an important role in the risk of ischemic stroke. Ulcerated or fissured plaque, characterized by irregular surface morphology, exposes thrombogenic materials to the bloodstream, possibly leading to life- or brain-threatening thrombosis and embolization. Therefore, the quantification of plaque surface irregularity is important to identify high-risk plaques that would likely lead to vascular events. Although a number of studies have characterized plaque surface irregularity using subjective classification schemes with two or more categories, only a few have quantified surface irregularity using an objective and continuous quantity, such as Gaussian or mean curvature. In this …


Nonrigid Registration Of Three-Dimensional Ultrasound And Magnetic Resonance Images Of The Carotid Arteries, Nuwan D Nanayakkara, Bernard Chiu, Abbas Samani, J David Spence, Jagath Samarabandu, Grace Parraga, Aaron Fenster Feb 2009

Nonrigid Registration Of Three-Dimensional Ultrasound And Magnetic Resonance Images Of The Carotid Arteries, Nuwan D Nanayakkara, Bernard Chiu, Abbas Samani, J David Spence, Jagath Samarabandu, Grace Parraga, Aaron Fenster

Medical Biophysics Publications

Atherosclerosis at the carotid bifurcation can result in cerebral emboli, which in turn can block the blood supply to the brain causing ischemic strokes. Noninvasive imaging tools that better characterize arterial wall, and atherosclerotic plaque structure and composition may help to determine the factors which lead to the development of unstable lesions, and identify patients at risk of plaque disruption and stroke. Carotid magnetic resonance (MR) imaging allows for the characterization of carotid vessel wall and plaque composition, the characterization of normal and pathological arterial wall, the quantification of plaque size, and the detection of plaque integrity. On the other …


Consistency Check Of Planned Adaptive Option On Helical Tomotherapy., M Schirm, S Yartsev, G Bauman, Jerry J. Battista Dr., Jacob Van Dyk Dec 2008

Consistency Check Of Planned Adaptive Option On Helical Tomotherapy., M Schirm, S Yartsev, G Bauman, Jerry J. Battista Dr., Jacob Van Dyk

Oncology Publications

This study aims to evaluate a new Planned Adaptive software (TomoTherapy Inc., Madison, WI) of the helical tomotherapy system by retrospective verification and adaptive re-planning of radiation treatment. Four patients with different disease sites (brain, nasal cavity, lungs, prostate) were planned in duplicate using the diagnostic planning kVCT data set and MVCT studies of the first treatment fraction with the same optimization parameters for both plan types. The dosimetric characteristics of minimum, maximum, and mean dose to the targets as well as to organs at risk were compared. Both sets of plans were used for calculation of dose distributions in …


Quantification Of Carotid Vessel Wall And Plaque Thickness Change Using 3d Ultrasound Images, Bernard Chiu, Micaela Egger, J David Spence, Grace Parraga, Aaron Fenster Aug 2008

Quantification Of Carotid Vessel Wall And Plaque Thickness Change Using 3d Ultrasound Images, Bernard Chiu, Micaela Egger, J David Spence, Grace Parraga, Aaron Fenster

Medical Biophysics Publications

Quantitative measurements of carotid plaque burden progression or regression are important in monitoring patients and in evaluation of new treatment options. 3D ultrasound (US) has been used to monitor the progression or regression of carotid artery plaques. This paper reports on the development and application of a method used to analyze changes in carotid plaque morphology from 3D US. The technique used is evaluated using manual segmentations of the arterial wall and lumen from 3D US images acquired in two imaging sessions. To reduce the effect of segmentation variability, segmentation was performed five times each for the wall and lumen. …


Quality Assurance Of Radiation Therapy Planning Systems: Current Status And Remaining Challenges., Jacob Van Dyk May 2008

Quality Assurance Of Radiation Therapy Planning Systems: Current Status And Remaining Challenges., Jacob Van Dyk

Oncology Publications

Computerized radiation therapy planning systems (RTPSs) are pivotal for treatment planning. The acceptance, commissioning, and quality control of RTPSs are uniquely complex and are described in the American Association of Physicists in Medicine Task Group Report 53 (1998) and International Atomic Energy Agency Technical Report Series No. 430 (2004). The International Atomic Energy Agency also developed a document and data package for use by vendors and purchasers to aid with acceptance testing of RTPSs. This document is based on International Electrotechnical Commission standard 62083 (2000) and describes both "type" tests to be performed in the factory and "site" tests to …