Open Access. Powered by Scholars. Published by Universities.®
- Discipline
Articles 1 - 14 of 14
Full-Text Articles in Medical Biophysics
Free-Breathing Pulmonary Mr Imaging To Quantify Regional Ventilation, Dante P I Capaldi, Rachel L Eddy, Sarah Svenningsen, Fumin Guo, John S H Baxter, A Jonathan Mcleod, Parameswaran Nair, David G Mccormack, Grace Parraga
Free-Breathing Pulmonary Mr Imaging To Quantify Regional Ventilation, Dante P I Capaldi, Rachel L Eddy, Sarah Svenningsen, Fumin Guo, John S H Baxter, A Jonathan Mcleod, Parameswaran Nair, David G Mccormack, Grace Parraga
Medical Biophysics Publications
Purpose: To measure regional specific ventilation with free-breathing hydrogen 1 (1H) magnetic resonance (MR) imaging without exogenous contrast material and to investigate correlations with hyperpolarized helium 3 (3He) MR imaging and pulmonary function test measurements in healthy volunteers and patients with asthma.
Materials and Methods: Subjects underwent free-breathing 1H and static breath-hold hyperpolarized 3He MR imaging as well as spirometry and plethysmography; participants were consecutively recruited between January and June 2017. Free-breathing 1H MR imaging was performed with an optimized balanced steady-state free-precession sequence; images were retrospectively grouped into tidal inspiration or tidal expiration volumes with exponentially weighted phase interpolation. …
Pulmonary Imaging Biomarkers Of Gas Trapping And Emphysema In Copd: (3)He Mr Imaging And Ct Parametric Response Maps, Dante P I Capaldi, Nanxi Zha, Fumin Guo, Damien Pike, David G Mccormack, Miranda Kirby, Grace Parraga
Pulmonary Imaging Biomarkers Of Gas Trapping And Emphysema In Copd: (3)He Mr Imaging And Ct Parametric Response Maps, Dante P I Capaldi, Nanxi Zha, Fumin Guo, Damien Pike, David G Mccormack, Miranda Kirby, Grace Parraga
Medical Biophysics Publications
PURPOSE: To directly compare magnetic resonance (MR) imaging and computed tomography (CT) parametric response map (PRM) measurements of gas trapping and emphysema in ex-smokers both with and without chronic obstructive pulmonary disease (COPD).
MATERIALS AND METHODS: Participants provided written informed consent to a protocol that was approved by a local research ethics board and Health Canada and was compliant with the HIPAA (Institutional Review Board Reg. #00000940). The prospectively planned study was performed from March 2014 to December 2014 and included 58 ex-smokers (mean age, 73 years ± 9) with (n = 32; mean age, 74 years ± 7) and …
Functional Lung Avoidance For Individualized Radiotherapy (Flair): Study Protocol For A Randomized, Double-Blind Clinical Trial., Douglas A Hoover, Dante Pi Capaldi, Khadija Sheikh, David A Palma, George B Rodrigues, A Rashid Dar, Edward Yu, Brian Dingle, Mark Landis, Walter Kocha, Michael Sanatani, Mark Vincent, Jawaid Younus, Sara Kuruvilla, Stewart Gaede, Grace Parraga, Brian P Yaremko
Functional Lung Avoidance For Individualized Radiotherapy (Flair): Study Protocol For A Randomized, Double-Blind Clinical Trial., Douglas A Hoover, Dante Pi Capaldi, Khadija Sheikh, David A Palma, George B Rodrigues, A Rashid Dar, Edward Yu, Brian Dingle, Mark Landis, Walter Kocha, Michael Sanatani, Mark Vincent, Jawaid Younus, Sara Kuruvilla, Stewart Gaede, Grace Parraga, Brian P Yaremko
Medical Biophysics Publications
BACKGROUND: Although radiotherapy is a key component of curative-intent treatment for locally advanced, unresectable non-small cell lung cancer (NSCLC), it can be associated with substantial pulmonary toxicity in some patients. Current radiotherapy planning techniques aim to minimize the radiation dose to the lungs, without accounting for regional variations in lung function. Many patients, particularly smokers, can have substantial regional differences in pulmonary ventilation patterns, and it has been hypothesized that preferential avoidance of functional lung during radiotherapy may reduce toxicity. Although several investigators have shown that functional lung can be identified using advanced imaging techniques and/or demonstrated the feasibility and …
A Magnetic-Resonance-Imaging-Compatible Remote Catheter Navigation System., Mohammad Ali Tavallaei, Yogesh Thakur, Syed Haider, Maria Drangova
A Magnetic-Resonance-Imaging-Compatible Remote Catheter Navigation System., Mohammad Ali Tavallaei, Yogesh Thakur, Syed Haider, Maria Drangova
Medical Biophysics Publications
A remote catheter navigation system compatible with magnetic resonance imaging (MRI) has been developed to facilitate MRI-guided catheterization procedures. The interventionalist's conventional motions (axial motion and rotation) on an input catheter - acting as the master - are measured by a pair of optical encoders, and a custom embedded system relays the motions to a pair of ultrasonic motors. The ultrasonic motors drive the patient catheter (slave) within the MRI scanner, replicating the motion of the input catheter. The performance of the remote catheter navigation system was evaluated in terms of accuracy and delay of motion replication outside and within …
Hyperpolarized (3)He Magnetic Resonance Imaging-Derived Pulmonary Pressure-Volume Curves, Stephen Choy, Andrew Wheatley, David G Mccormack, Grace Parraga
Hyperpolarized (3)He Magnetic Resonance Imaging-Derived Pulmonary Pressure-Volume Curves, Stephen Choy, Andrew Wheatley, David G Mccormack, Grace Parraga
Medical Biophysics Publications
We aimed to evaluate the potential for the use of hyperpolarized helium-3 magnetic resonance imaging (MRI) apparent diffusion coefficient (ADC) surrogates of alveolar size, together with literature-based morphological parameters in a theoretical model of lung mechanics to simulate noninvasive transpulmonary pressure-volume curves. Fourteen ex-smokers with chronic obstructive pulmonary disease (COPD) (n = 8 stage II, n = 6 stage III/IV COPD) and five age-matched never-smokers, provided written, informed consent and were evaluated at baseline and 26 + or - 2 mo later (n = 15 subjects) using plethysmography, spirometry, and (3)He MRI at 3.0 T. Total lung capacity, residual volume, …
Chronic Obstructive Pulmonary Disease: Longitudinal Hyperpolarized (3)He Mr Imaging, Miranda Kirby, Lindsay Mathew, Andrew Wheatley, Giles E Santyr, David G Mccormack, Grace Parraga
Chronic Obstructive Pulmonary Disease: Longitudinal Hyperpolarized (3)He Mr Imaging, Miranda Kirby, Lindsay Mathew, Andrew Wheatley, Giles E Santyr, David G Mccormack, Grace Parraga
Medical Biophysics Publications
PURPOSE: To quantitatively evaluate a small pilot group of ex-smokers with chronic obstructive pulmonary disease (COPD) and healthy volunteers during approximately 2 years by using hyperpolarized helium 3 ((3)He) magnetic resonance (MR) imaging.
MATERIALS AND METHODS: All subjects provided written informed consent to the study protocol, which was approved by the local research ethics board and Health Canada and was compliant with the Personal Information Protection and Electronic Documents Act and HIPAA. Hyperpolarized (3)He MR imaging, hydrogen 1 MR imaging, spirometry, and plethysmography were performed in 15 ex-smokers with COPD and five healthy volunteers (with the same mean age and …
Schedule For Ct Image Guidance In Treating Prostate Cancer With Helical Tomotherapy., G Beldjoudi, S Yartsev, G Bauman, Jerry J. Battista Dr., Jacob Van Dyk
Schedule For Ct Image Guidance In Treating Prostate Cancer With Helical Tomotherapy., G Beldjoudi, S Yartsev, G Bauman, Jerry J. Battista Dr., Jacob Van Dyk
Oncology Publications
The aim of this study was to determine the effect of reducing the number of image guidance sessions and patient-specific target margins on the dose distribution in the treatment of prostate cancer with helical tomotherapy. 20 patients with prostate cancer who were treated with helical tomotherapy using daily megavoltage CT (MVCT) imaging before treatment served as the study population. The average geometric shifts applied for set-up corrections, as a result of co-registration of MVCT and planning kilovoltage CT studies over an increasing number of image guidance sessions, were determined. Simulation of the consequences of various imaging scenarios on the dose …
The Effects Of Field-Of-View And Patient Size On Ct Numbers From Cone-Beam Computed Tomography., Katrina Y T Seet, Arvand Barghi, Slav Yartsev, Jacob Van Dyk
The Effects Of Field-Of-View And Patient Size On Ct Numbers From Cone-Beam Computed Tomography., Katrina Y T Seet, Arvand Barghi, Slav Yartsev, Jacob Van Dyk
Oncology Publications
Cone-beam computed tomography (CBCT) is used for patient alignment before treatment and is ideal for use in adaptive radiotherapy to account for tumor shrinkage, organ deformation and weight loss. However, CBCT images are prone to artifacts such as streaking and cupping effects, reducing image quality and CT number accuracy. Our goal was to determine the optimum combination of cone-beam imaging options to increase the accuracy of image CT numbers. Several phantoms with and without inserts of known relative electron densities were imaged using the Varian on-board imaging system. It was found that CT numbers are most influenced by the selection …
Nonrigid Registration Of Three-Dimensional Ultrasound And Magnetic Resonance Images Of The Carotid Arteries, Nuwan D Nanayakkara, Bernard Chiu, Abbas Samani, J David Spence, Jagath Samarabandu, Grace Parraga, Aaron Fenster
Nonrigid Registration Of Three-Dimensional Ultrasound And Magnetic Resonance Images Of The Carotid Arteries, Nuwan D Nanayakkara, Bernard Chiu, Abbas Samani, J David Spence, Jagath Samarabandu, Grace Parraga, Aaron Fenster
Medical Biophysics Publications
Atherosclerosis at the carotid bifurcation can result in cerebral emboli, which in turn can block the blood supply to the brain causing ischemic strokes. Noninvasive imaging tools that better characterize arterial wall, and atherosclerotic plaque structure and composition may help to determine the factors which lead to the development of unstable lesions, and identify patients at risk of plaque disruption and stroke. Carotid magnetic resonance (MR) imaging allows for the characterization of carotid vessel wall and plaque composition, the characterization of normal and pathological arterial wall, the quantification of plaque size, and the detection of plaque integrity. On the other …
Adaptive Radiation Therapy For Localized Mesothelioma With Mediastinal Metastasis Using Helical Tomotherapy., James Renaud, Slav Yartsev, A Rashid Dar, Jacob Van Dyk
Adaptive Radiation Therapy For Localized Mesothelioma With Mediastinal Metastasis Using Helical Tomotherapy., James Renaud, Slav Yartsev, A Rashid Dar, Jacob Van Dyk
Oncology Publications
The purpose of this study was to compare 2 adaptive radiotherapy strategies with helical tomotherapy. A patient having mesothelioma with mediastinal nodes was treated using helical tomotherapy with pretreatment megavoltage CT (MVCT) imaging. Gross tumor volumes (GTVs) were outlined on every MVCT study. Two alternatives for adapting the treatment were investigated: (1) keeping the prescribed dose to the targets while reducing the dose to the OARs and (2) escalating the target dose while maintaining the original level of healthy tissue sparing. Intensity modulated radiotherapy (step-and-shoot IMRT) and 3D conformal radiotherapy (3DCRT) plans for the patient were generated and compared. The …
Consistency Check Of Planned Adaptive Option On Helical Tomotherapy., M Schirm, S Yartsev, G Bauman, Jerry J. Battista Dr., Jacob Van Dyk
Consistency Check Of Planned Adaptive Option On Helical Tomotherapy., M Schirm, S Yartsev, G Bauman, Jerry J. Battista Dr., Jacob Van Dyk
Oncology Publications
This study aims to evaluate a new Planned Adaptive software (TomoTherapy Inc., Madison, WI) of the helical tomotherapy system by retrospective verification and adaptive re-planning of radiation treatment. Four patients with different disease sites (brain, nasal cavity, lungs, prostate) were planned in duplicate using the diagnostic planning kVCT data set and MVCT studies of the first treatment fraction with the same optimization parameters for both plan types. The dosimetric characteristics of minimum, maximum, and mean dose to the targets as well as to organs at risk were compared. Both sets of plans were used for calculation of dose distributions in …
Mapping And Quantifying Hyperpolarized 3he Magnetic Resonance Imaging Apparent Diffusion Coefficient Gradients, Andrea Evans, David G Mccormack, Giles Santyr, Grace Parraga
Mapping And Quantifying Hyperpolarized 3he Magnetic Resonance Imaging Apparent Diffusion Coefficient Gradients, Andrea Evans, David G Mccormack, Giles Santyr, Grace Parraga
Medical Biophysics Publications
We measured hyperpolarized 3He magnetic resonance imaging (MRI) apparent diffusion coefficients (ADC) and quantified ADC gradients in each three-by-three voxel region of interest (ROI). Such local ADC gradients can be represented in vector maps showing the magnitude (|G3x3|) and direction of ADC gradients, providing a qualitative visualization tool and quantitative measurement of airway and air space heterogeneity. Twenty-four subjects (15 male, mean age=67+/-7 yr) with global initiative for chronic obstructive lung disease (GOLD) stage II (n=9, mean age 68+/-6 yr), GOLD stage III chronic obstructive pulmonary disease (COPD; n=7, mean age 67+/-8 yr), and age-matched healthy volunteers (n=8, mean age …
Quality Assurance Of Radiation Therapy Planning Systems: Current Status And Remaining Challenges., Jacob Van Dyk
Quality Assurance Of Radiation Therapy Planning Systems: Current Status And Remaining Challenges., Jacob Van Dyk
Oncology Publications
Computerized radiation therapy planning systems (RTPSs) are pivotal for treatment planning. The acceptance, commissioning, and quality control of RTPSs are uniquely complex and are described in the American Association of Physicists in Medicine Task Group Report 53 (1998) and International Atomic Energy Agency Technical Report Series No. 430 (2004). The International Atomic Energy Agency also developed a document and data package for use by vendors and purchasers to aid with acceptance testing of RTPSs. This document is based on International Electrotechnical Commission standard 62083 (2000) and describes both "type" tests to be performed in the factory and "site" tests to …
Adaptive Radiotherapy Planning On Decreasing Gross Tumor Volumes As Seen On Megavoltage Computed Tomography Images., Curtis Woodford, Slav Yartsev, R. Dar, Glenn Bauman, Jacob Van Dyk
Adaptive Radiotherapy Planning On Decreasing Gross Tumor Volumes As Seen On Megavoltage Computed Tomography Images., Curtis Woodford, Slav Yartsev, R. Dar, Glenn Bauman, Jacob Van Dyk
Oncology Publications
PURPOSE: To evaluate gross tumor volume (GTV) changes for patients with non-small-cell lung cancer by using daily megavoltage (MV) computed tomography (CT) studies acquired before each treatment fraction on helical tomotherapy and to relate the potential benefit of adaptive image-guided radiotherapy to changes in GTV.
METHODS AND MATERIALS: Seventeen patients were prescribed 30 fractions of radiotherapy on helical tomotherapy for non-small-cell lung cancer at London Regional Cancer Program from Dec 2005 to March 2007. The GTV was contoured on the daily MVCT studies of each patient. Adapted plans were created using merged MVCT-kilovoltage CT image sets to investigate the advantages …