Open Access. Powered by Scholars. Published by Universities.®

Medical Biophysics Commons™

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 11 of 11

Full-Text Articles in Medical Biophysics

Imaging Of Lung Function Using Hyperpolarized Helium-3 Magnetic Resonance Imaging: Review Of Current And Emerging Translational Methods And Applications, Sean Fain, Mark L Schiebler, David G Mccormack, Grace Parraga Dec 2010

Imaging Of Lung Function Using Hyperpolarized Helium-3 Magnetic Resonance Imaging: Review Of Current And Emerging Translational Methods And Applications, Sean Fain, Mark L Schiebler, David G Mccormack, Grace Parraga

Medical Biophysics Publications

During the past several years there has been extensive development and application of hyperpolarized helium-3 (HP (3)He) magnetic resonance imaging (MRI) in clinical respiratory indications such as asthma, chronic obstructive pulmonary disease, cystic fibrosis, radiation-induced lung injury, and transplantation. This review focuses on the state-of-the-art of HP (3)He MRI and its application to clinical pulmonary research. This is not an overview of the physics of the method, as this topic has been covered previously. We focus here on the potential of this imaging method and its challenges in demonstrating new types of information that has the potential to influence clinical …


New To Ols For Monitoring Gamma Camera Uniformity, Brad K. Lofton Dec 2010

New To Ols For Monitoring Gamma Camera Uniformity, Brad K. Lofton

Dissertations and Theses (Open Access)

Detector uniformity is a fundamental performance characteristic of all modern gamma camera systems, and ensuring a stable, uniform detector response is critical for maintaining clinical images that are free of artifact. For these reasons, the assessment of detector uniformity is one of the most common activities associated with a successful clinical quality assurance program in gamma camera imaging. The evaluation of this parameter, however, is often unclear because it is highly dependent upon acquisition conditions, reviewer expertise, and the application of somewhat arbitrary limits that do not characterize the spatial location of the non-uniformities. Furthermore, as the goal of any …


Hyperpolarized (3)He Magnetic Resonance Imaging-Derived Pulmonary Pressure-Volume Curves, Stephen Choy, Andrew Wheatley, David G Mccormack, Grace Parraga Aug 2010

Hyperpolarized (3)He Magnetic Resonance Imaging-Derived Pulmonary Pressure-Volume Curves, Stephen Choy, Andrew Wheatley, David G Mccormack, Grace Parraga

Medical Biophysics Publications

We aimed to evaluate the potential for the use of hyperpolarized helium-3 magnetic resonance imaging (MRI) apparent diffusion coefficient (ADC) surrogates of alveolar size, together with literature-based morphological parameters in a theoretical model of lung mechanics to simulate noninvasive transpulmonary pressure-volume curves. Fourteen ex-smokers with chronic obstructive pulmonary disease (COPD) (n = 8 stage II, n = 6 stage III/IV COPD) and five age-matched never-smokers, provided written, informed consent and were evaluated at baseline and 26 + or - 2 mo later (n = 15 subjects) using plethysmography, spirometry, and (3)He MRI at 3.0 T. Total lung capacity, residual volume, …


Volumetric Modulated Arc Therapy Evaluation With The Radiological Physics Center Head And Neck Phantom, Kelly Kisling Aug 2010

Volumetric Modulated Arc Therapy Evaluation With The Radiological Physics Center Head And Neck Phantom, Kelly Kisling

Dissertations and Theses (Open Access)

Validation of treatment plan quality and dose calculation accuracy is essential for new radiotherapy techniques, including volumetric modulated arc therapy (VMAT). VMAT delivers intensity modulated radiotherapy treatments while simultaneously rotating the gantry, adding an additional level of complexity to both the dose calculation and delivery of VMAT treatments compared to static gantry IMRT. The purpose of this project was to compare two VMAT systems, Elekta VMAT and Varian RapidArc, to the current standard of care, IMRT, in terms of both treatment plan quality and dosimetric delivery accuracy using the Radiological Physics Center (RPC) head and neck (H&N) phantom. Clinically relevant …


Chronic Obstructive Pulmonary Disease: Longitudinal Hyperpolarized (3)He Mr Imaging, Miranda Kirby, Lindsay Mathew, Andrew Wheatley, Giles E Santyr, David G Mccormack, Grace Parraga Jul 2010

Chronic Obstructive Pulmonary Disease: Longitudinal Hyperpolarized (3)He Mr Imaging, Miranda Kirby, Lindsay Mathew, Andrew Wheatley, Giles E Santyr, David G Mccormack, Grace Parraga

Medical Biophysics Publications

PURPOSE: To quantitatively evaluate a small pilot group of ex-smokers with chronic obstructive pulmonary disease (COPD) and healthy volunteers during approximately 2 years by using hyperpolarized helium 3 ((3)He) magnetic resonance (MR) imaging.

MATERIALS AND METHODS: All subjects provided written informed consent to the study protocol, which was approved by the local research ethics board and Health Canada and was compliant with the Personal Information Protection and Electronic Documents Act and HIPAA. Hyperpolarized (3)He MR imaging, hydrogen 1 MR imaging, spirometry, and plethysmography were performed in 15 ex-smokers with COPD and five healthy volunteers (with the same mean age and …


Prostaglandin E(2) Is Crucial In The Response Of Podocytes To Fluid Flow Shear Stress., Tarak Srivastava, Ellen T. Mccarthy, Ram Sharma, Patricia A. Cudmore, Mukut Sharma, Mark L. Johnson, Lynda F. Bonewald Jun 2010

Prostaglandin E(2) Is Crucial In The Response Of Podocytes To Fluid Flow Shear Stress., Tarak Srivastava, Ellen T. Mccarthy, Ram Sharma, Patricia A. Cudmore, Mukut Sharma, Mark L. Johnson, Lynda F. Bonewald

Manuscripts, Articles, Book Chapters and Other Papers

Podocytes play a key role in maintaining and modulating the filtration barrier of the glomerulus. Because of their location, podocytes are exposed to mechanical strain in the form of fluid flow shear stress (FFSS). Several human diseases are characterized by glomerular hyperfiltration, such as diabetes mellitus and hypertension. The response of podocytes to FFSS at physiological or pathological levels is not known. We exposed cultured podocytes to FFSS, and studied changes in actin cytoskeleton, prostaglandin E(2) (PGE(2)) production and expression of cyclooxygenase-1 and-2 (COX-1, COX-2). FFSS caused a reduction in transversal F-actin stress filaments and the appearance of cortical actin …


Measurement Of The Vascular Input Function In Mice For Dce-Mri, Dustin K. Ragan May 2010

Measurement Of The Vascular Input Function In Mice For Dce-Mri, Dustin K. Ragan

Dissertations and Theses (Open Access)

DCE-MRI is an important technique in the study of small animal cancer models because its sensitivity to vascular changes opens the possibility of quantitative assessment of early therapeutic response. However, extraction of physiologically descriptive parameters from DCE-MRI data relies upon measurement of the vascular input function (VIF), which represents the contrast agent concentration time course in the blood plasma. This is difficult in small animal models due to artifacts associated with partial volume, inflow enhancement, and the limited temporal resolution achievable with MR imaging. In this work, the development of a suite of techniques for high temporal resolution, artifact resistant …


Thoracic Radiotherapy Treatment Planning With Cine Pet/Ct, Adam C. Riegel May 2010

Thoracic Radiotherapy Treatment Planning With Cine Pet/Ct, Adam C. Riegel

Dissertations and Theses (Open Access)

Purpose: Respiratory motion causes substantial uncertainty in radiotherapy treatment planning. Four-dimensional computed tomography (4D-CT) is a useful tool to image tumor motion during normal respiration. Treatment margins can be reduced by targeting the motion path of the tumor. The expense and complexity of 4D-CT, however, may be cost-prohibitive at some facilities. We developed an image processing technique to produce images from cine CT that contain significant motion information without 4D-CT. The purpose of this work was to compare cine CT and 4D-CT for the purposes of target delineation and dose calculation, and to explore the role of PET in target …


Schedule For Ct Image Guidance In Treating Prostate Cancer With Helical Tomotherapy., G Beldjoudi, S Yartsev, G Bauman, Jerry J. Battista Dr., Jacob Van Dyk Mar 2010

Schedule For Ct Image Guidance In Treating Prostate Cancer With Helical Tomotherapy., G Beldjoudi, S Yartsev, G Bauman, Jerry J. Battista Dr., Jacob Van Dyk

Oncology Publications

The aim of this study was to determine the effect of reducing the number of image guidance sessions and patient-specific target margins on the dose distribution in the treatment of prostate cancer with helical tomotherapy. 20 patients with prostate cancer who were treated with helical tomotherapy using daily megavoltage CT (MVCT) imaging before treatment served as the study population. The average geometric shifts applied for set-up corrections, as a result of co-registration of MVCT and planning kilovoltage CT studies over an increasing number of image guidance sessions, were determined. Simulation of the consequences of various imaging scenarios on the dose …


Beyond The Dvh - Spatial And Biological Radiotherapy Treatment Planning, Bo Zhao Jan 2010

Beyond The Dvh - Spatial And Biological Radiotherapy Treatment Planning, Bo Zhao

Wayne State University Dissertations

Purpose: Both spatial and biological information are necessary in order to perform true optimization of a treatment plan and for predicting clinical outcome. The goal of this work is to develop an enhanced treatment plan evaluation tool which incorporates biological parameters and retains spatial dose information.

Methods: A software system named SABER (Spatial And Biological Evaluation for Radiotherapy) is developed which provides biological plan evaluation with a novel combination of features. It incorporates hyperradiosensitivity using the induced-repair model and applies the new concept of Dose Convolution Filter (DCF) to simulate dose wash-out …


Raman Spectroscopic Modeling Of T- Lymphocyte Activation And Detection Of Acute Renal Allograft Rejection, Kristian L. Brown Jan 2010

Raman Spectroscopic Modeling Of T- Lymphocyte Activation And Detection Of Acute Renal Allograft Rejection, Kristian L. Brown

Wayne State University Dissertations

ABSTRACT

RAMAN SPECTROSCOPIC MODELING OF T-LYMPHOCYTE ACTIVATION AND DETECTION OF ACUTE RENAL ALLOGRAFT REJECTION

By

KRISTIAN L. BROWN

2010

Advisor: Gregory Auner, PhD

Major: Biomedical Engineering

Degree: Doctor of Philosophy

Despite the advances made in the area of kidney transplantation, the disparity between the demand and available donated organs remains a dominant and unresolved issue. Given the paucity of available renal allografts the preservation of existing grafts is vital. One factor that has negatively impacted renal allograft survival is acute rejection (AR). Traditionally, kidney transplant centers have used elevations in serum creatinine as a screening tool for detecting AR. However, …