Open Access. Powered by Scholars. Published by Universities.®
- Institution
-
- The Texas Medical Center Library (19)
- Louisiana State University (4)
- East Tennessee State University (2)
- University of Tennessee Health Science Center (2)
- Virginia Commonwealth University (2)
-
- Nova Southeastern University (1)
- Old Dominion University (1)
- Portland State University (1)
- Rowan University (1)
- Thomas Jefferson University (1)
- University of Alkafeel (1)
- University of Louisville (1)
- University of Nebraska at Omaha (1)
- University of North Florida (1)
- Western Kentucky University (1)
- Western University (1)
- Keyword
-
- Apoptosis (2)
- Cancer (2)
- Female (2)
- Humans (2)
- IROC (2)
-
- Lung (2)
- MRgRT (2)
- Machine learning (2)
- Motion (2)
- PET/CT (2)
- Proton therapy (2)
- Quantum DNA (2)
- Radiation therapy (2)
- Radiotherapy (2)
- Second cancer (2)
- Tomography (2)
- 3D dosimetry (1)
- 3D printed (1)
- 4D CT (1)
- 4D optimization (1)
- 4D-CT (1)
- AI (1)
- Acoustic imaging (1)
- Adaptive Radiation Therapy (1)
- Algorithms (1)
- Anthropomorphic head and neck phantom (1)
- Anthropomorphic thorax phantom (1)
- Area Under Curve (1)
- Artifacts (1)
- Artificial intelligence (1)
- Publication Year
- Publication
-
- Dissertations and Theses (Open Access) (19)
- Faculty Publications (2)
- LSU Doctoral Dissertations (2)
- LSU Master's Theses (2)
- Theses and Dissertations (2)
-
- Al-Bahir (1)
- Department of Medicine Faculty Papers (1)
- Dissertations and Theses (1)
- Electrical & Computer Engineering Faculty Publications (1)
- Electronic Theses and Dissertations (1)
- Journal of Wellness (1)
- Mahurin Honors College Capstone Experience/Thesis Projects (1)
- Medical Biophysics Publications (1)
- NSU REACH and IPE Day (1)
- PANDION: The Osprey Journal of Research and Ideas (1)
- Rowan-Virtua Research Day (1)
- UNO Student Research and Creative Activity Fair (1)
- Undergraduate Honors Theses (1)
- Publication Type
- File Type
Articles 31 - 40 of 40
Full-Text Articles in Medical Biophysics
Strategies Of Balancing: Regulation Of Posture As A Complex Phenomenon, Allison Leich Hilbun
Strategies Of Balancing: Regulation Of Posture As A Complex Phenomenon, Allison Leich Hilbun
Electronic Theses and Dissertations
The complexity of the interface between the muscular system and the nervous system is still elusive. We investigated how the neuromuscular system functions and how it is influenced by various perturbations. Postural stability was selected as the model system, because this system provides complex output, which could indicate underlying mechanisms and feedback loops of the neuromuscular system. We hypothesized that aging, physical pain, and mental and physical perturbations affect balancing strategy, and based on these observations, we constructed a model that simulates many aspects of the neuromuscular system. Our results show that aging changes the control strategy of balancing from …
Improving Attenuation Correction In Hybrid Positron Emission To Mography, Hua Asher Ai
Improving Attenuation Correction In Hybrid Positron Emission To Mography, Hua Asher Ai
Dissertations and Theses (Open Access)
Hybrid positron emission tomography imaging techniques such as PET/CT and PET/MR have undergone significant developments over the last two decades and have played increasingly more important roles both in research and in the clinic. A unique advantage PET has over other clinical imaging modalities is its capability of accurate quantification. However, as the most critical component of PET quantification, attenuation correction in hybrid PET systems is challenged in several different aspects, including the spatial- temporal mismatch between the PET emission images and the associated attenuation images provided by the complementary modality, and the difficulty in bone identification in the MR-based …
Characterization Of Low Density Intracranial Lesions Using Dual-Energy Computed To Mography, Jessica L. Nute
Characterization Of Low Density Intracranial Lesions Using Dual-Energy Computed To Mography, Jessica L. Nute
Dissertations and Theses (Open Access)
Calcific and hemorrhagic foci of susceptibility are frequently encountered on routine brain MR studies. Both etiologies cause variations in local magnetic field strength, leading to dark regions on the MR images that cannot be classified. Single-energy CT (SECT) can be used to identify lesions with attenuation over 100 HU as calcific, however lesions with lower attenuation cannot be reliably identified. While calcific lesions are unlikely to cause harm, hemorrhagic lesions carry a risk of subsequent intracranial bleeding; as such, identification of hemorrhage is vital in preventing the inappropriate use of anticoagulant medications in patients with hemorrhagic lesions.
Given there currently …
Development Of A New Independent Monte Carlo Dose Calculation Quality Assurance Audit To Ol For Clinical Trials, Austin M. Faught
Development Of A New Independent Monte Carlo Dose Calculation Quality Assurance Audit To Ol For Clinical Trials, Austin M. Faught
Dissertations and Theses (Open Access)
Introduction: Commercially available treatment planning systems (TPS) may use a number of different radiation dose calculation algorithms during the planning process. The Radiological Physics Center (RPC), tasked with ensuring clinically comparable and consistent dose delivery amongst institutions participating in NCI funded multi-institutional clinical trials, has traditionally relied upon measurements to achieve this objective. As a supplement to the tools used by the RPC, an independent dose calculation tool is needed to determine patient dose distributions in three dimensions so as to act as a quality assurance tool for the dose calculations.
Methods: Multiple source models representing the output of Elekta …
Evaluation Of Artifacts In Experimental Cine 4d Ct Acquisition Methods, Sarah Joy
Evaluation Of Artifacts In Experimental Cine 4d Ct Acquisition Methods, Sarah Joy
Dissertations and Theses (Open Access)
Four-dimensional computed tomography (4D CT) has increased the accuracy of radiation treatment planning for patients in whom the extent of target motion is large. 4D CT has become a standard of care for radiation treatment simulation, allowing decreased motion artifacts and increased spatiotemporal localization of anatomical structures that move. However, motion artifacts may still remain. These artifacts, or artificial anatomic spatial distributions, add a systematic uncertainty to the treatment process and limit the accuracy of lung function images derived from CT. We proposed to reduce the motion artifacts in cine 4D CT by using three novel investigational 4D CT acquisition …
Scanned Ion Beam Therapy For Thoracic Tumors, John Gordon Eley
Scanned Ion Beam Therapy For Thoracic Tumors, John Gordon Eley
Dissertations and Theses (Open Access)
Although frequently cured of Hodgkin lymphoma, adolescents and young adults can develop radiation induced second cancers. These patients could potentially benefit from scanned ion radiotherapy yet likely would require motion mitigation strategies. In theory, four-dimensional (4D) optimization of ion beam fields for individual motion states of respiration can enable superior sparing of healthy tissue near moving targets, compared to other motion mitigation strategies. Furthermore, carbon-ion therapy can sometimes provide greater relative biological effectiveness (RBE) for cell sterilization in a target but nearly equivalent RBE in tissue upstream of the target, compared to proton therapy. Thus, we expected that for some …
Development And Implementation Of Acoustic Feedback Control For Scanning Probe Microscopy, Rodolfo Fernandez Rodriguez
Development And Implementation Of Acoustic Feedback Control For Scanning Probe Microscopy, Rodolfo Fernandez Rodriguez
Dissertations and Theses
A remote-sensing acoustic method for implementing position control feedback in Scanning Probe Microscopy (SPM) is presented. The capabilities of this feedback control using the new Whispering Gallery Acoustic Sensing (WGAS) method is demonstrated in a Shear-force Scanning Probe Microscope that uses a sharp probe attached to a piezoelectric Quartz Tuning Fork (QTF) firmly mounted on the microscope's frame. As the QTF is electrically driven its mechanical response reaches the SPM frame which then acts as a resonant cavity producing acoustic modes measured with an acoustic sensor strategically placed on the SPM head. The novelty of the WGAS resides in using …
Risk Of Second Malignant Neoplasms Following Proton Arc Therapy And Volumetric Modulated Arc Therapy For Prostate Cancer, Laura A. Rechner
Risk Of Second Malignant Neoplasms Following Proton Arc Therapy And Volumetric Modulated Arc Therapy For Prostate Cancer, Laura A. Rechner
Dissertations and Theses (Open Access)
The risk of second malignant neoplasms (SMNs) following prostate radiotherapy is a concern due to the large population of survivors and decreasing age at diagnosis. It is known that parallel-opposed beam proton therapy carries a lower risk than photon IMRT. However, a comparison of SMN risk following proton and photon arc therapies has not previously been reported. The purpose of this study was to predict the ratio of excess relative risk (RRR) of SMN incidence following proton arc therapy to that after volumetric modulated arc therapy (VMAT). Additionally, we investigated the impact of margin size and the effect …
New To Ols For Monitoring Gamma Camera Uniformity, Brad K. Lofton
New To Ols For Monitoring Gamma Camera Uniformity, Brad K. Lofton
Dissertations and Theses (Open Access)
Detector uniformity is a fundamental performance characteristic of all modern gamma camera systems, and ensuring a stable, uniform detector response is critical for maintaining clinical images that are free of artifact. For these reasons, the assessment of detector uniformity is one of the most common activities associated with a successful clinical quality assurance program in gamma camera imaging. The evaluation of this parameter, however, is often unclear because it is highly dependent upon acquisition conditions, reviewer expertise, and the application of somewhat arbitrary limits that do not characterize the spatial location of the non-uniformities. Furthermore, as the goal of any …
Thoracic Radiotherapy Treatment Planning With Cine Pet/Ct, Adam C. Riegel
Thoracic Radiotherapy Treatment Planning With Cine Pet/Ct, Adam C. Riegel
Dissertations and Theses (Open Access)
Purpose: Respiratory motion causes substantial uncertainty in radiotherapy treatment planning. Four-dimensional computed tomography (4D-CT) is a useful tool to image tumor motion during normal respiration. Treatment margins can be reduced by targeting the motion path of the tumor. The expense and complexity of 4D-CT, however, may be cost-prohibitive at some facilities. We developed an image processing technique to produce images from cine CT that contain significant motion information without 4D-CT. The purpose of this work was to compare cine CT and 4D-CT for the purposes of target delineation and dose calculation, and to explore the role of PET in target …