Ai-Driven Segmentation And Volumetric Response Modeling Of Liver Regions To Radiotherapy, Aashish Chandra Gupta Aug 2026

Ai-Driven Segmentation And Volumetric Response Modeling Of Liver Regions To Radiotherapy, Aashish Chandra Gupta

Dissertations and Theses (Open Access)

In liver-directed radiotherapy (RT), liver regions receiving higher doses typically undergo atrophy while contralateral/adjacent lower-dose regions may exhibit compensatory hypertrophy through regeneration of healthy tissue. Optimizing the RT plan to promote regional hypertrophy while minimizing the risk of developing atrophy has the potential to enhance post-RT liver function and long-term survivorship. However, current clinical practice largely relies on global liver dose-volume metrics during RT-planning, which may obscure favorable dose-response correlation and limit actionable guidance for clinicians. Therefore, we hypothesized that post-RT regional liver response is governed by a combination of region-specific dose-volume and patient clinical features, and that these responses …


Dose Characterization Of Galactic Cosmic Rays In The Human Brain: A Phits-Based Study With A Segmented Anatomical Phantom, Shanice N. Manning Jul 2025

Dose Characterization Of Galactic Cosmic Rays In The Human Brain: A Phits-Based Study With A Segmented Anatomical Phantom, Shanice N. Manning

LSU Master's Theses

Astronauts aboard the International Space Station (ISS) are chronically exposed to a complex space radiation environment composed of galactic cosmic rays (GCR), solar particles, and Earth's trapped radiation. These high-energy particles interact with spacecraft shielding, producing secondary particles that can penetrate inside and deposit energy in sensitive tissues. Although animal studies have been useful in assessing space radiation risks, anatomical and physiological differences limit their applicability to human anatomy especially neuroanatomy. To address this gap, we developed a computational framework to model radiation dose distribution within the human brain using Monte Carlo simulations in Particle and Heavy Ion Transport code …


Development Of Lineal Energy Spectrum-Based Biological Effects Models For Protons, Joseph M. Decunha, Fada Guan, David Grosshans, Zhongxing Liao, Dragan Mirkovic, Oleg Vassiliev, Radhe Mohan May 2025

Development Of Lineal Energy Spectrum-Based Biological Effects Models For Protons, Joseph M. Decunha, Fada Guan, David Grosshans, Zhongxing Liao, Dragan Mirkovic, Oleg Vassiliev, Radhe Mohan

Dissertations and Theses (Open Access)

In this dissertation, methods are developed and described to allow for the rapid calculation of microdosimetric spectra (specifically, lineal energy) for protons. SuperTrack, a GPU-accelerated tool for calculation of microdosimetric spectra was developed and is capable of computing lineal energy spectra up to 5000x faster than using Geant4 directly. Proton lineal energy spectra generated by SuperTrack are indistinguishable from those generated by Geant4. With SuperTrack, large libraries of lineal energy spectra for monoenergetic protons spanning 0-300 MeV have been developed. The proton lineal energy spectra calculated by SuperTrack have been compared to experimental measurements made by a tissue equivalent proportional …


Influential Factors And Predicting Dose Delivery Accuracy For Imaging And Radiation Oncology Core’S Phantom Program Using Machine Learning, Hunter Mehrens Aug 2024

Influential Factors And Predicting Dose Delivery Accuracy For Imaging And Radiation Oncology Core’S Phantom Program Using Machine Learning, Hunter Mehrens

Dissertations and Theses (Open Access)

IROC’s mission is to help ensure consistent and comparable, high-quality radiotherapy across clinics that participate in national clinical trials. To obtain this mission, IROC’s phantom program provides a third-party end-to-end check of the clinical workflow of a patient receiving radiotherapy. The goal of the phantom audit is to compare the dose delivered to the dose planned by the treatment system ensuring dose delivery accuracy. While IROC’s phantoms are better equipped to catch dose delivery errors compared to a clinic’s QA process, the end-to-end process and reporting of results is time-consuming creating a bottleneck for clinical trial participation. Furthermore, IROC’s passing …


Evaluation Of An End-To-End Radiotherapy Treatment Planning Pipeline For Prostate Cancer, Mohammad Daniel El Basha, Court Laurence, Carlos Eduardo Cardenas, Julianne Pollard-Larkin, Steven Frank, David T. Fuentes, Falk Poenisch, Zhiqian H. Yu May 2024

Evaluation Of An End-To-End Radiotherapy Treatment Planning Pipeline For Prostate Cancer, Mohammad Daniel El Basha, Court Laurence, Carlos Eduardo Cardenas, Julianne Pollard-Larkin, Steven Frank, David T. Fuentes, Falk Poenisch, Zhiqian H. Yu

Dissertations and Theses (Open Access)

Radiation treatment planning is a crucial and time-intensive process in radiation therapy. This planning involves carefully designing a treatment regimen tailored to a patient’s specific condition, including the type, location, and size of the tumor with reference to surrounding healthy tissues. For prostate cancer, this tumor may be either local, locally advanced with extracapsular involvement, or extend into the pelvic lymph node chain. Automating essential parts of this process would allow for the rapid development of effective treatment plans and better plan optimization to enhance tumor control for better outcomes.

The first objective of this work, to automate the treatment …


Quantifying The Magnitude Of To Tal Dose Deviation Caused By Various Sources Of Error Among Iroc Phantom Irradiation Results, Sharbacha S. Edward Dec 2022

Quantifying The Magnitude Of To Tal Dose Deviation Caused By Various Sources Of Error Among Iroc Phantom Irradiation Results, Sharbacha S. Edward

Dissertations and Theses (Open Access)

The Imaging and Radiation Oncology Core (IROC) phantoms are used as an end-to-end test of an institution’s radiotherapy processes, and for clinical trial credentialing. Phantoms are treated like patients, and evaluation of the doses received by the thermoluminescent dosimeters (TLDs) inside the phantom, reflects the accuracy with which an institution can image, plan and irradiate a phantom or patient. Recent phantom results show that among the hundreds of various IROC phantoms irradiated annually, 8-17% of institutions fail this test. The purpose of this work was to investigate the various types of errors that may occur during the treatment process and …


Thermal Properties Of 18f-Fdg Uptake And Imaging In Positron Emission Tomography Scans Of Cancerous Cells, Carleigh R. Eagle Aug 2021

Thermal Properties Of 18f-Fdg Uptake And Imaging In Positron Emission Tomography Scans Of Cancerous Cells, Carleigh R. Eagle

PANDION: The Osprey Journal of Research and Ideas

Positron Emission Tomography (PET) scans can utilize a radioactive tracer, in this case 2-deoxy2-[fluorine-18] fluoro-D-glucose (18F-FDG), to visualize malignant tumors in cancer patients. The uptake was compared to glucose to understand the difference in thermal properties, which contribute to the ability to image the cancerous cells. The uptake of 18F-FDG by cancer cells and the imaging process of positron emission tomography were reviewed from a thermodynamic perspective. Gastrointestinal and neurological imaging techniques were reviewed to understand the role of PET imaging in different areas of the human body.


Advancement Of A 3d Computational Phantom And Its Age Scaling Methodologies For Retrospective Dose Reconstruction Studies, Aashish Gupta Aug 2021

Advancement Of A 3d Computational Phantom And Its Age Scaling Methodologies For Retrospective Dose Reconstruction Studies, Aashish Gupta

Dissertations and Theses (Open Access)

We have used a 3D age-scalable computational phantom for over two decades for retrospective dose reconstruction studies of childhood cancer survivors (CCS) treated with 2D historic radiotherapy (RT). However, our phantom and its age scaling functions (ASF) must be updated so that it can be used in studies that include survivors treated with contemporary RT. We aimed to implement our phantom and its age scaling functions in DICOM format and determine the feasibility of applying our ASFs to accurately scale the whole-body CT-based anatomies.

In the implementation study, we developed Python scripts that model the phantom and ASFs in a …


Modeling Anatomic Changes For Adaptive Radiotherapy In Locally Advanced Lung Cancer Patient Population, James Alexander Kavanaugh Aug 2020

Modeling Anatomic Changes For Adaptive Radiotherapy In Locally Advanced Lung Cancer Patient Population, James Alexander Kavanaugh

LSU Doctoral Dissertations

Anatomic changes occurring mid-treatment for patients undergoing radiation therapy for locally advanced lung cancer can degrade the quality of the intended treatment plan. These changes include tumor regression, geometric misalignment, and lung density changes (atelectasis and pleural effusion), and are visible on the daily 3D cone beam CT (CBCT). To maintain the intended treatment quality, adaptive radiotherapy (ART) can be employed to modify the treatment plan to account for these anatomic changes. However, the evaluation on when to adapt is currently completed manually by the treating clinicians, resulting in a subjective and inconsistent application. To address these limitations, a series …


Evaluation Of Ventilation Assistance For Improving Respiratory Reproducibility In Radiation Therapy, Cameron J. Sprowls Apr 2019

Evaluation Of Ventilation Assistance For Improving Respiratory Reproducibility In Radiation Therapy, Cameron J. Sprowls

LSU Master's Theses

Background: Respiratory motion affects all tumor sites in the thorax and abdomen. Variations of the respiratory pattern cause variations of the tumor motion which can result in differences between the planned and delivered dose distributions. Previous breathing guidance techniques have been investigated to improve respiratory reproducibility; however, ventilation assistance has not been investigated. We evaluated using bi-level positive airway pressure (BIPAP) ventilation assistance for improving respiratory reproducibility in patients with tumor sites impacted by respiratory motion.

Methods: Written informed consent was obtained for 10 patients currently undergoing radiation therapy treatment. Patients participated in sessions over their course of treatment, which …


Development And Implementation Of A Homogeneous And A Heterogeneous Anthropomorphic End To End Quality Assurance Audit System Phantom For Magnetic Resonance Guided Radiotherapy Modalities Ranging From 0.35 T To 1.50 T, Angela Steinmann Aug 2018

Development And Implementation Of A Homogeneous And A Heterogeneous Anthropomorphic End To End Quality Assurance Audit System Phantom For Magnetic Resonance Guided Radiotherapy Modalities Ranging From 0.35 T To 1.50 T, Angela Steinmann

Dissertations and Theses (Open Access)

Introduction: Magnetic resonance (MR) guided radiation therapy (MRgRT) is an emerging field that integrates an MR imager with either a linear accelerator or three radioactive cobalt-60 sources. Before institutions participate in multi-institutional NCI-sponsored clinical trials, they are required to perform a credentialing test provided by IROC-Houston. During the credentialing test, end-to-end phantoms are used to evaluate the institution’s ability to perform consistent and accurate radiation treatments. IROC-Houston’s conventional anthropomorphic phantoms are not visible in MR, thus they are insufficient for MRgRT systems. The purpose of this work was to create an anthropomorphic thorax and a head and neck (H&N) phantom …


Development Of 3d-Printed Patient Specific Bolus For Clinical Use In To Tal Scalp Irradiation, Garrett Baltz May 2018

Development Of 3d-Printed Patient Specific Bolus For Clinical Use In To Tal Scalp Irradiation, Garrett Baltz

Dissertations and Theses (Open Access)

Total scalp irradiation (TSI) is a specialized radiation therapy technique that aims to deliver a uniform dose to the entire scalp. Original electron-based TSI techniques had limited homogeneity due to hot and cold spots created at field junctions due to the multiple matched fields that were required to treat the entire scalp. The transition to photon volumetric-modulated arc therapy based TSI techniques has improved homogeneity, to the point where non-conformal bolus is now a limiting factor. Bolus is required to build-up full dose to the scalp surface in total scalp irradiation. Creating bolus that is conformal to the scalp is …


Improving Attenuation Correction In Hybrid Positron Emission To Mography, Hua Asher Ai Aug 2015

Improving Attenuation Correction In Hybrid Positron Emission To Mography, Hua Asher Ai

Dissertations and Theses (Open Access)

Hybrid positron emission tomography imaging techniques such as PET/CT and PET/MR have undergone significant developments over the last two decades and have played increasingly more important roles both in research and in the clinic. A unique advantage PET has over other clinical imaging modalities is its capability of accurate quantification. However, as the most critical component of PET quantification, attenuation correction in hybrid PET systems is challenged in several different aspects, including the spatial- temporal mismatch between the PET emission images and the associated attenuation images provided by the complementary modality, and the difficulty in bone identification in the MR-based …


Characterization Of Low Density Intracranial Lesions Using Dual-Energy Computed To Mography, Jessica L. Nute May 2015

Characterization Of Low Density Intracranial Lesions Using Dual-Energy Computed To Mography, Jessica L. Nute

Dissertations and Theses (Open Access)

Calcific and hemorrhagic foci of susceptibility are frequently encountered on routine brain MR studies. Both etiologies cause variations in local magnetic field strength, leading to dark regions on the MR images that cannot be classified. Single-energy CT (SECT) can be used to identify lesions with attenuation over 100 HU as calcific, however lesions with lower attenuation cannot be reliably identified. While calcific lesions are unlikely to cause harm, hemorrhagic lesions carry a risk of subsequent intracranial bleeding; as such, identification of hemorrhage is vital in preventing the inappropriate use of anticoagulant medications in patients with hemorrhagic lesions.

Given there currently …


Development Of A New Independent Monte Carlo Dose Calculation Quality Assurance Audit To Ol For Clinical Trials, Austin M. Faught Aug 2014

Development Of A New Independent Monte Carlo Dose Calculation Quality Assurance Audit To Ol For Clinical Trials, Austin M. Faught

Dissertations and Theses (Open Access)

Introduction: Commercially available treatment planning systems (TPS) may use a number of different radiation dose calculation algorithms during the planning process. The Radiological Physics Center (RPC), tasked with ensuring clinically comparable and consistent dose delivery amongst institutions participating in NCI funded multi-institutional clinical trials, has traditionally relied upon measurements to achieve this objective. As a supplement to the tools used by the RPC, an independent dose calculation tool is needed to determine patient dose distributions in three dimensions so as to act as a quality assurance tool for the dose calculations.

Methods: Multiple source models representing the output of Elekta …


Evaluation Of Artifacts In Experimental Cine 4d Ct Acquisition Methods, Sarah Joy May 2014

Evaluation Of Artifacts In Experimental Cine 4d Ct Acquisition Methods, Sarah Joy

Dissertations and Theses (Open Access)

Four-dimensional computed tomography (4D CT) has increased the accuracy of radiation treatment planning for patients in whom the extent of target motion is large. 4D CT has become a standard of care for radiation treatment simulation, allowing decreased motion artifacts and increased spatiotemporal localization of anatomical structures that move. However, motion artifacts may still remain. These artifacts, or artificial anatomic spatial distributions, add a systematic uncertainty to the treatment process and limit the accuracy of lung function images derived from CT. We proposed to reduce the motion artifacts in cine 4D CT by using three novel investigational 4D CT acquisition …


New To Ols For Monitoring Gamma Camera Uniformity, Brad K. Lofton Dec 2010

New To Ols For Monitoring Gamma Camera Uniformity, Brad K. Lofton

Dissertations and Theses (Open Access)

Detector uniformity is a fundamental performance characteristic of all modern gamma camera systems, and ensuring a stable, uniform detector response is critical for maintaining clinical images that are free of artifact. For these reasons, the assessment of detector uniformity is one of the most common activities associated with a successful clinical quality assurance program in gamma camera imaging. The evaluation of this parameter, however, is often unclear because it is highly dependent upon acquisition conditions, reviewer expertise, and the application of somewhat arbitrary limits that do not characterize the spatial location of the non-uniformities. Furthermore, as the goal of any …


Thoracic Radiotherapy Treatment Planning With Cine Pet/Ct, Adam C. Riegel May 2010

Thoracic Radiotherapy Treatment Planning With Cine Pet/Ct, Adam C. Riegel

Dissertations and Theses (Open Access)

Purpose: Respiratory motion causes substantial uncertainty in radiotherapy treatment planning. Four-dimensional computed tomography (4D-CT) is a useful tool to image tumor motion during normal respiration. Treatment margins can be reduced by targeting the motion path of the tumor. The expense and complexity of 4D-CT, however, may be cost-prohibitive at some facilities. We developed an image processing technique to produce images from cine CT that contain significant motion information without 4D-CT. The purpose of this work was to compare cine CT and 4D-CT for the purposes of target delineation and dose calculation, and to explore the role of PET in target …