Open Access. Powered by Scholars. Published by Universities.®
- Institution
- Keyword
-
- Computer-Assisted (6)
- Humans (6)
- Radiotherapy Planning (6)
- Radiotherapy Planning, Computer-Assisted (6)
- Radiotherapy (5)
-
- Radiotherapy Dosage (5)
- Oncology (4)
- Radiation (4)
- Radiation therapy (4)
- Tomography (4)
- Aged (3)
- Algorithms (3)
- Female (3)
- Imaging (3)
- Lung Neoplasms (3)
- Male (3)
- Phantoms (3)
- Phantoms, Imaging (3)
- Radiation Dosage (3)
- Radiation Therapy (3)
- Tomography, X-Ray Computed (3)
- X-Ray Computed (3)
- Artificial intelligence (2)
- CT (2)
- Cancer (2)
- Carcinoma (2)
- Deep Learning (2)
- Dose Fractionation (2)
- Dose-Response Relationship (2)
- Dose-Response Relationship, Radiation (2)
- Publication Year
- Publication
- Publication Type
Articles 31 - 37 of 37
Full-Text Articles in Medical Biophysics
The Effects Of Field-Of-View And Patient Size On Ct Numbers From Cone-Beam Computed Tomography., Katrina Y T Seet, Arvand Barghi, Slav Yartsev, Jacob Van Dyk
The Effects Of Field-Of-View And Patient Size On Ct Numbers From Cone-Beam Computed Tomography., Katrina Y T Seet, Arvand Barghi, Slav Yartsev, Jacob Van Dyk
Oncology Publications
Cone-beam computed tomography (CBCT) is used for patient alignment before treatment and is ideal for use in adaptive radiotherapy to account for tumor shrinkage, organ deformation and weight loss. However, CBCT images are prone to artifacts such as streaking and cupping effects, reducing image quality and CT number accuracy. Our goal was to determine the optimum combination of cone-beam imaging options to increase the accuracy of image CT numbers. Several phantoms with and without inserts of known relative electron densities were imaged using the Varian on-board imaging system. It was found that CT numbers are most influenced by the selection …
Effects Of Genistein Following Fractionated Lung Irradiation In Mice., Andrea E Para, Andrea Bezjak, Ivan W T Yeung, Jacob Van Dyk, Richard P Hill
Effects Of Genistein Following Fractionated Lung Irradiation In Mice., Andrea E Para, Andrea Bezjak, Ivan W T Yeung, Jacob Van Dyk, Richard P Hill
Oncology Publications
BACKGROUND AND PURPOSE: This study investigated protection of lung injury by genistein following fractionated doses of radiation and its effect on tumor response.
MATERIAL AND METHODS: C3H/HeJ mice were irradiated (100 kVp X-rays) with 9 fractions of 3.1 Gy over 30 days (approximately equivalent to 10 Gy single dose) and were maintained on a genistein diet ( approximately 10mg/kg). Damage was assessed over 28 weeks in lung cells by a cytokinesis block micronucleus (MN) assay and by changes in breathing rate and histology. Tumor protection was assessed using a colony assay to determine cell survival following in situ irradiation of …
Y27632, A Rho-Activated Kinase Inhibitor, Normalizes Dysregulation In Alpha1-Adrenergic Receptor-Induced Contraction Of Lyon Hypertensive Rat Artery Smooth Muscle., Maria Regina Freitas, Masumi Eto, Jason A Kirkbride, Christa Schott, Jean Sassard, Jean-Claude Stoclet
Y27632, A Rho-Activated Kinase Inhibitor, Normalizes Dysregulation In Alpha1-Adrenergic Receptor-Induced Contraction Of Lyon Hypertensive Rat Artery Smooth Muscle., Maria Regina Freitas, Masumi Eto, Jason A Kirkbride, Christa Schott, Jean Sassard, Jean-Claude Stoclet
Department of Molecular Physiology and Biophysics Faculty Papers
RhoA-activated kinase (ROK) is involved in the disorders of smooth muscle contraction found in hypertension model animals and patients. We examined whether the alpha1-adrenergic receptor agonist-induced ROK signal is perturbed in resistance small mesentery artery (SMA) of Lyon genetically hypertensive (LH) rats, using a ROK antagonist, Y27632. Smooth muscle strips of SMA and aorta were isolated from LH and Lyon normotensive (LN) rats. After Ca(2+)-depletion and pre-treatment with phenylephrine (PE), smooth muscle contraction was induced by serial additions of CaCl(2). In LH SMA Ca(2+) permeated cells to a lesser extent as compared with LN SMA, while CaCl(2)-induced contraction of LH …
Adaptive Radiation Therapy For Localized Mesothelioma With Mediastinal Metastasis Using Helical Tomotherapy., James Renaud, Slav Yartsev, A Rashid Dar, Jacob Van Dyk
Adaptive Radiation Therapy For Localized Mesothelioma With Mediastinal Metastasis Using Helical Tomotherapy., James Renaud, Slav Yartsev, A Rashid Dar, Jacob Van Dyk
Oncology Publications
The purpose of this study was to compare 2 adaptive radiotherapy strategies with helical tomotherapy. A patient having mesothelioma with mediastinal nodes was treated using helical tomotherapy with pretreatment megavoltage CT (MVCT) imaging. Gross tumor volumes (GTVs) were outlined on every MVCT study. Two alternatives for adapting the treatment were investigated: (1) keeping the prescribed dose to the targets while reducing the dose to the OARs and (2) escalating the target dose while maintaining the original level of healthy tissue sparing. Intensity modulated radiotherapy (step-and-shoot IMRT) and 3D conformal radiotherapy (3DCRT) plans for the patient were generated and compared. The …
Consistency Check Of Planned Adaptive Option On Helical Tomotherapy., M Schirm, S Yartsev, G Bauman, Jerry J. Battista Dr., Jacob Van Dyk
Consistency Check Of Planned Adaptive Option On Helical Tomotherapy., M Schirm, S Yartsev, G Bauman, Jerry J. Battista Dr., Jacob Van Dyk
Oncology Publications
This study aims to evaluate a new Planned Adaptive software (TomoTherapy Inc., Madison, WI) of the helical tomotherapy system by retrospective verification and adaptive re-planning of radiation treatment. Four patients with different disease sites (brain, nasal cavity, lungs, prostate) were planned in duplicate using the diagnostic planning kVCT data set and MVCT studies of the first treatment fraction with the same optimization parameters for both plan types. The dosimetric characteristics of minimum, maximum, and mean dose to the targets as well as to organs at risk were compared. Both sets of plans were used for calculation of dose distributions in …
Quality Assurance Of Radiation Therapy Planning Systems: Current Status And Remaining Challenges., Jacob Van Dyk
Quality Assurance Of Radiation Therapy Planning Systems: Current Status And Remaining Challenges., Jacob Van Dyk
Oncology Publications
Computerized radiation therapy planning systems (RTPSs) are pivotal for treatment planning. The acceptance, commissioning, and quality control of RTPSs are uniquely complex and are described in the American Association of Physicists in Medicine Task Group Report 53 (1998) and International Atomic Energy Agency Technical Report Series No. 430 (2004). The International Atomic Energy Agency also developed a document and data package for use by vendors and purchasers to aid with acceptance testing of RTPSs. This document is based on International Electrotechnical Commission standard 62083 (2000) and describes both "type" tests to be performed in the factory and "site" tests to …
Adaptive Radiotherapy Planning On Decreasing Gross Tumor Volumes As Seen On Megavoltage Computed Tomography Images., Curtis Woodford, Slav Yartsev, R. Dar, Glenn Bauman, Jacob Van Dyk
Adaptive Radiotherapy Planning On Decreasing Gross Tumor Volumes As Seen On Megavoltage Computed Tomography Images., Curtis Woodford, Slav Yartsev, R. Dar, Glenn Bauman, Jacob Van Dyk
Oncology Publications
PURPOSE: To evaluate gross tumor volume (GTV) changes for patients with non-small-cell lung cancer by using daily megavoltage (MV) computed tomography (CT) studies acquired before each treatment fraction on helical tomotherapy and to relate the potential benefit of adaptive image-guided radiotherapy to changes in GTV.
METHODS AND MATERIALS: Seventeen patients were prescribed 30 fractions of radiotherapy on helical tomotherapy for non-small-cell lung cancer at London Regional Cancer Program from Dec 2005 to March 2007. The GTV was contoured on the daily MVCT studies of each patient. Adapted plans were created using merged MVCT-kilovoltage CT image sets to investigate the advantages …