Open Access. Powered by Scholars. Published by Universities.®
- Institution
- Keyword
-
- Imaging (2)
- MRI (2)
- 3D printing (1)
- Acute Kidney Rejection (1)
- Acute lymphoblastic leukemia (1)
-
- Algorithms (1)
- Anisotropy (1)
- Anthropomorphic phantom (1)
- Apoptosis (1)
- Arbitrary waveform generator (1)
- Area Under Curve (1)
- Artery (1)
- Artifact (1)
- Automation (1)
- Biodegradable (1)
- Bioprinting (1)
- Blood Pressure (1)
- Blood oxygen saturation (1)
- Bone Regeneration (1)
- Brachytherapy (1)
- Brain deformation (1)
- Breast cancer (1)
- CT colonography (virtual colonoscopy) (1)
- CT dose (1)
- CTDI (1)
- Calcification (1)
- Cell receptor expression (1)
- Chemistry and Biochemistry (1)
- Compressed sensing (1)
- Computed Tomography (1)
- Publication
- Publication Type
Articles 1 - 17 of 17
Full-Text Articles in Medical Biophysics
Estimation Of Free Water-Corrected Microscopic Fractional Anisotropy., Nico J J Arezza, Tales Santini, Mohammad Omer, Corey A Baron
Estimation Of Free Water-Corrected Microscopic Fractional Anisotropy., Nico J J Arezza, Tales Santini, Mohammad Omer, Corey A Baron
Medical Biophysics Publications
Water diffusion anisotropy MRI is sensitive to microstructural changes in the brain that are hallmarks of various neurological conditions. However, conventional metrics like fractional anisotropy are confounded by neuron fiber orientation dispersion, and the relatively low resolution of diffusion-weighted MRI gives rise to significant free water partial volume effects in many brain regions that are adjacent to cerebrospinal fluid. Microscopic fractional anisotropy is a recent metric that can report water diffusion anisotropy independent of neuron fiber orientation dispersion but is still susceptible to free water contamination. In this paper, we present a free water elimination (FWE) technique to estimate microscopic …
Longitudinal Oxygen Imaging In 3d (Bio)Printed Models, Ryan Curtis O'Connell
Longitudinal Oxygen Imaging In 3d (Bio)Printed Models, Ryan Curtis O'Connell
Graduate Theses, Dissertations, and Problem Reports (ETD)
Electron paramagnetic resonance (EPR), and its molecular imaging modality, is a powerful tool to noninvasively map various biological and chemical markers within objects of interest. Reliable data acquisition is a major impeding factor for longitudinal hands-off measurements. Measurements are especially challenging in biomedical applications, as live objects are not static. Frequent changes occur that require constant fine recalibration of the EPR detection system, called the resonator. To enable longitudinal imaging, a technology permitting automatic digital control of resonator coupling, tuning, and EPR data acquisition was developed. Automation was achieved through the utilization of a microcontroller and digital peripheral components such …
Thermal Properties Of 18f-Fdg Uptake And Imaging In Positron Emission Tomography Scans Of Cancerous Cells, Carleigh R. Eagle
Thermal Properties Of 18f-Fdg Uptake And Imaging In Positron Emission Tomography Scans Of Cancerous Cells, Carleigh R. Eagle
PANDION: The Osprey Journal of Research and Ideas
Positron Emission Tomography (PET) scans can utilize a radioactive tracer, in this case 2-deoxy2-[fluorine-18] fluoro-D-glucose (18F-FDG), to visualize malignant tumors in cancer patients. The uptake was compared to glucose to understand the difference in thermal properties, which contribute to the ability to image the cancerous cells. The uptake of 18F-FDG by cancer cells and the imaging process of positron emission tomography were reviewed from a thermodynamic perspective. Gastrointestinal and neurological imaging techniques were reviewed to understand the role of PET imaging in different areas of the human body.
Development Of Quantitative Molecular Photoacoustic Imaging For Noninvasive Cancer Diagnostics, Cayla Zandbergen
Development Of Quantitative Molecular Photoacoustic Imaging For Noninvasive Cancer Diagnostics, Cayla Zandbergen
Dissertations and Theses (Open Access)
Traditional diagnostic imaging provides clinicians with anatomical information that guides both diagnosis and treatment planning; however, once a tumor has progressed enough to be visible, it has often reached an advanced stage. Molecular imaging techniques allow for real-time visualization of chemical and biological processes via imaging of specific biomarkers, which can facilitate detection of malignancies before they become visible. One biomarker of interest is blood oxygen saturation (SO2) due to its correlation with hypoxia, which is associated with increased tumor malignancy; some studies have also established SO2 as an independent biomarker of disease progression. Additionally, because cancerous …
Rapid Microscopic Fractional Anisotropy Imaging Via An Optimized Linear Regression Formulation., N J J Arezza, D H Y Tse, C A Baron
Rapid Microscopic Fractional Anisotropy Imaging Via An Optimized Linear Regression Formulation., N J J Arezza, D H Y Tse, C A Baron
Medical Biophysics Publications
Water diffusion anisotropy in the human brain is affected by disease, trauma, and development. Microscopic fractional anisotropy (μFA) is a diffusion MRI (dMRI) metric that can quantify water diffusion anisotropy independent of neuron fiber orientation dispersion. However, there are several different techniques to estimate μFA and few have demonstrated full brain imaging capabilities within clinically viable scan times and resolutions. Here, we present an optimized spherical tensor encoding (STE) technique to acquire μFA directly from the 2nd order cumulant expansion of the powder averaged dMRI signal obtained from direct linear regression (i.e. diffusion kurtosis) which requires fewer powder-averaged signals than …
Development Of Fully Balanced Ssfp And Computer Vision Applications For Mri-Assisted Radiosurgery (Mars), Jeremiah Sanders
Development Of Fully Balanced Ssfp And Computer Vision Applications For Mri-Assisted Radiosurgery (Mars), Jeremiah Sanders
Dissertations and Theses (Open Access)
Prostate cancer is the second most common cancer in men and the second-leading cause of cancer death in men. Brachytherapy is a highly effective treatment option for prostate cancer, and is the most cost-effective initial treatment among all other therapeutic options for low to intermediate risk patients of prostate cancer. In low-dose-rate (LDR) brachytherapy, verifying the location of the radioactive seeds within the prostate and in relation to critical normal structures after seed implantation is essential to ensuring positive treatment outcomes.
One current gap in knowledge is how to simultaneously image the prostate, surrounding anatomy, and radioactive seeds within the …
Artifact Identification For Blood Pressure And Photoplethysmography Signals In An Unsupervised Environment, Pooi Khoon Lim
Artifact Identification For Blood Pressure And Photoplethysmography Signals In An Unsupervised Environment, Pooi Khoon Lim
Student Works (2020-2029)
Physiological signals play a significant role in clinical diagnosis, it always acts as a major input of a decision support system. However, the physiological signal is easily corrupted by different factors especially motion artifacts. Several research works have been tried to recover the underlying physiological signal by suppressing the artifact. However, not much attention has been paid to situation where the artifact is too extreme and the artifact suppression is not possible. In this situation, physiological signal quality must be evaluated before any further assessment. In this study, an automated artifact detection algorithm was developed for Blood Pressure and PPG …
Development Of A Sonically Powered Biodegradable Nanogenerator For Bone Regeneration, Avi Patel
Development Of A Sonically Powered Biodegradable Nanogenerator For Bone Regeneration, Avi Patel
Honors Scholar Theses
Background: Reconstruction of bone fractures and defects remains a big challenge in orthopedic surgery. While regenerative engineering has advanced the field greatly using a combination of biomaterial scaffolds and stem cells, one matter of difficulty is inducing osteogenesis in these cells. Recent works have shown electricity’s ability to promote osteogenesis in stem cell lines when seeded in bone scaffolds; however, typical electrical stimulators are either (a) externally housed and require overcomplex percutaneous wires be connected to the implanted scaffold or (b) implanted non-degradable devices which contain toxic batteries and require invasive removal surgeries.
Objective: Here, we establish a biodegradable, piezoelectric …
Dynamic Light Scattering Optical Coherence Tomography To Probe Motion Of Subcellular Scatterers., Nico J J Arezza, Marjan Razani, Michael C Kolios
Dynamic Light Scattering Optical Coherence Tomography To Probe Motion Of Subcellular Scatterers., Nico J J Arezza, Marjan Razani, Michael C Kolios
Medical Biophysics Publications
Optical coherence tomography (OCT) is used to provide anatomical information of biological systems but can also provide functional information by characterizing the motion of intracellular structures. Dynamic light scattering OCT was performed on intact, control MCF-7 breast cancer cells and cells either treated with paclitaxel to induce apoptosis or deprived of nutrients to induce oncosis. Autocorrelations (ACs) of the temporal fluctuations of OCT intensity signals demonstrate a significant decrease in decorrelation time after 24 h in both the paclitaxel-treated and nutrient-deprived cell groups but no significant differences between the two groups. The acquired ACs were then used as input for …
Development Of Low Frequency Electron Paramagnetic Resonance Methods And Instrumentation For Biological Applications, Laura A. Buchanan
Development Of Low Frequency Electron Paramagnetic Resonance Methods And Instrumentation For Biological Applications, Laura A. Buchanan
Electronic Theses and Dissertations
EPR is a powerful biophysical tool that can be used to measure tumor physiology. With the addition of magnetic field gradients, the spectral properties of paramagnetic species can be mapped. To facilitate EPR imaging, methods and instrumentation at frequencies between 250 MHz and 1 GHz were developed.
At low spin concentrations, the rapid scan background signal is often many times larger than the EPR signal of interest. To help remove the background contribution, a data acquisition procedure that takes advantage of a cross-loop resonator and bipolar power supplies was developed at 250 MHz. In this procedure, two scans are collected. …
Characterization Of Low Density Intracranial Lesions Using Dual-Energy Computed To Mography, Jessica L. Nute
Characterization Of Low Density Intracranial Lesions Using Dual-Energy Computed To Mography, Jessica L. Nute
Dissertations and Theses (Open Access)
Calcific and hemorrhagic foci of susceptibility are frequently encountered on routine brain MR studies. Both etiologies cause variations in local magnetic field strength, leading to dark regions on the MR images that cannot be classified. Single-energy CT (SECT) can be used to identify lesions with attenuation over 100 HU as calcific, however lesions with lower attenuation cannot be reliably identified. While calcific lesions are unlikely to cause harm, hemorrhagic lesions carry a risk of subsequent intracranial bleeding; as such, identification of hemorrhage is vital in preventing the inappropriate use of anticoagulant medications in patients with hemorrhagic lesions.
Given there currently …
Implementation And Validation Of Aortic Remodeling In Hypertensive Rats, Shijia Zhao, Linxia Gu
Implementation And Validation Of Aortic Remodeling In Hypertensive Rats, Shijia Zhao, Linxia Gu
Department of Mechanical and Materials Engineering: Faculty Publications
A computational framework was implemented and validated to better understand the hypertensive artery remodeling in both geometric dimensions and material properties. Integrating the stress-modulated remodeling equations into commercial finite element codes allows a better control and visualization of local mechanical parameters. Both arterial thickening and stiffening effects were captured and visualized. An adaptive material remodeling strategy combined with the element birth and death techniques for the geometrical growth were implemented. The numerically predicted remodeling results in terms of the wall thickness, inner diameter, and the ratio of elastin to collagen content of the artery were compared with and fine-tuned by …
A Nonrigid Registration Method For Correcting Brain Deformation Induced By Tumor Resection, Yixun Liu, Chengjun Yao, Fotis Drakopoulos, Jinsong Wu, Liangfu Zhou, Nikos Chrisochoides
A Nonrigid Registration Method For Correcting Brain Deformation Induced By Tumor Resection, Yixun Liu, Chengjun Yao, Fotis Drakopoulos, Jinsong Wu, Liangfu Zhou, Nikos Chrisochoides
Computer Science Faculty Publications
Purpose: This paper presents a nonrigid registration method to align preoperative MRI with intraoperative MRI to compensate for brain deformation during tumor resection. This method extends traditional point-based nonrigid registration in two aspects: (1) allow the input data to be incomplete and (2) simulate the underlying deformation with a heterogeneous biomechanical model.
Methods: The method formulates the registration as a three-variable (point correspondence, deformation field, and resection region) functional minimization problem, in which point correspondence is represented by a fuzzy assign matrix; Deformation field is represented by a piecewise linear function regularized by the strain energy of a heterogeneous biomechanical …
In-Vivo Ct Dosimetry During Virtual Colonoscopy, Jonathon W. Mueller
In-Vivo Ct Dosimetry During Virtual Colonoscopy, Jonathon W. Mueller
Dissertations and Theses (Open Access)
Virtual colonoscopy (VC) is a minimally invasive means for identifying colorectal polyps and colorectal lesions by insufflating a patient’s bowel, applying contrast agent via rectal catheter, and performing multi-detector computed tomography (MDCT) scans. The technique is recommended for colonic health screening by the American Cancer Society but not funded by the Centers for Medicare and Medicaid Services (CMS) partially because of potential risks from radiation exposure. To date, no in‐vivo organ dose measurements have been performed for MDCT scans; thus, the accuracy of any current dose estimates is currently unknown.
In this study, two TLDs were affixed to the inner …
Use Of Imaging Biomarkers To Assess Perfusion And Glucose Metabolism In The Skeletal Muscle Of Dystrophic Mice, Nabeel Ahmad, Ian Welch, Robert Grange, Jennifer Hadway, Savita Dhanvantari, David Hill, Ting-Yim Lee, Lisa M Hoffman
Use Of Imaging Biomarkers To Assess Perfusion And Glucose Metabolism In The Skeletal Muscle Of Dystrophic Mice, Nabeel Ahmad, Ian Welch, Robert Grange, Jennifer Hadway, Savita Dhanvantari, David Hill, Ting-Yim Lee, Lisa M Hoffman
Robarts Imaging Publications
BACKGROUND: Duchenne muscular dystrophy (DMD) is a severe neuromuscular disease that affects 1 in 3500 boys. The disease is characterized by progressive muscle degeneration that results from mutations in or loss of the cytoskeletal protein, dystrophin, from the glycoprotein membrane complex, thus increasing the susceptibility of contractile muscle to injury. To date, disease progression is typically assessed using invasive techniques such as muscle biopsies, and while there are recent reports of the use of magnetic resonance, ultrasound and optical imaging technologies to address the issue of disease progression and monitoring therapeutic intervention in dystrophic mice, our study aims to validate …
New To Ols For Monitoring Gamma Camera Uniformity, Brad K. Lofton
New To Ols For Monitoring Gamma Camera Uniformity, Brad K. Lofton
Dissertations and Theses (Open Access)
Detector uniformity is a fundamental performance characteristic of all modern gamma camera systems, and ensuring a stable, uniform detector response is critical for maintaining clinical images that are free of artifact. For these reasons, the assessment of detector uniformity is one of the most common activities associated with a successful clinical quality assurance program in gamma camera imaging. The evaluation of this parameter, however, is often unclear because it is highly dependent upon acquisition conditions, reviewer expertise, and the application of somewhat arbitrary limits that do not characterize the spatial location of the non-uniformities. Furthermore, as the goal of any …
Raman Spectroscopic Modeling Of T- Lymphocyte Activation And Detection Of Acute Renal Allograft Rejection, Kristian L. Brown
Raman Spectroscopic Modeling Of T- Lymphocyte Activation And Detection Of Acute Renal Allograft Rejection, Kristian L. Brown
Wayne State University Dissertations
ABSTRACT
RAMAN SPECTROSCOPIC MODELING OF T-LYMPHOCYTE ACTIVATION AND DETECTION OF ACUTE RENAL ALLOGRAFT REJECTION
By
KRISTIAN L. BROWN
2010
Advisor: Gregory Auner, PhD
Major: Biomedical Engineering
Degree: Doctor of Philosophy
Despite the advances made in the area of kidney transplantation, the disparity between the demand and available donated organs remains a dominant and unresolved issue. Given the paucity of available renal allografts the preservation of existing grafts is vital. One factor that has negatively impacted renal allograft survival is acute rejection (AR). Traditionally, kidney transplant centers have used elevations in serum creatinine as a screening tool for detecting AR. However, …