Open Access. Powered by Scholars. Published by Universities.®

Medical Biophysics Commons™

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 13 of 13

Full-Text Articles in Medical Biophysics

Ai-Driven Segmentation And Volumetric Response Modeling Of Liver Regions To Radiotherapy, Aashish Chandra Gupta Aug 2026

Ai-Driven Segmentation And Volumetric Response Modeling Of Liver Regions To Radiotherapy, Aashish Chandra Gupta

Dissertations and Theses (Open Access)

In liver-directed radiotherapy (RT), liver regions receiving higher doses typically undergo atrophy while contralateral/adjacent lower-dose regions may exhibit compensatory hypertrophy through regeneration of healthy tissue. Optimizing the RT plan to promote regional hypertrophy while minimizing the risk of developing atrophy has the potential to enhance post-RT liver function and long-term survivorship. However, current clinical practice largely relies on global liver dose-volume metrics during RT-planning, which may obscure favorable dose-response correlation and limit actionable guidance for clinicians. Therefore, we hypothesized that post-RT regional liver response is governed by a combination of region-specific dose-volume and patient clinical features, and that these responses …


Health Effects Of Cadmium And Manganese Exposure On Luteinizing Hormone Levels: A Pilot Study Of Female Infertility, Shatha F. Alhous, Anees A. Al-Hamzawi, Murtadha Sh. Aswood Mar 2026

Health Effects Of Cadmium And Manganese Exposure On Luteinizing Hormone Levels: A Pilot Study Of Female Infertility, Shatha F. Alhous, Anees A. Al-Hamzawi, Murtadha Sh. Aswood

Al-Bahir

Female infertility occurs for many reasons, some unknown. Exposure to heavy metals is a risk factor that negatively impacts on female reproductive system. Therefore, this study aimed to evaluate the effect of cadmium Cd and manganese Mn on luteinizing hormone LH levels for females’ infertility. This study included a healthy group (n = 20), primary infertile females (n = 40), and secondary infertile females (n = 20) collected from Al-Zahraa hospital in Najaf center, Iraq. The Atomic Absorption Spectroscopy (AAS) was used to measure the cadmium and manganese concentrations and LH levels were measured by a Maglumi 800 from Snibe …


Seizure Prediction In Epilepsy Patients, Gary Dean Cravens Feb 2022

Seizure Prediction In Epilepsy Patients, Gary Dean Cravens

NSU REACH and IPE Day

Purpose/Objective: Characterize rigorously the preictal period in epilepsy patients to improve the development of seizure prediction techniques. Background/Rationale: 30% of epilepsy patients are not well-controlled on medications and would benefit immensely from reliable seizure prediction. Methods/Methodology: Computational model consisting of in-silico Hodgkin-Huxley neurons arranged in a small-world topology using the Watts-Strogatz algorithm is used to generate synthetic electrocorticographic (ECoG) signals. ECoG data from 18 epilepsy patients is used to validate the model. Unsupervised machine learning is used with both patient and synthetic data to identify potential electrophysiologic biomarkers of the preictal period. Results/Findings: The model has shown states corresponding to …


Thermal Properties Of 18f-Fdg Uptake And Imaging In Positron Emission Tomography Scans Of Cancerous Cells, Carleigh R. Eagle Aug 2021

Thermal Properties Of 18f-Fdg Uptake And Imaging In Positron Emission Tomography Scans Of Cancerous Cells, Carleigh R. Eagle

PANDION: The Osprey Journal of Research and Ideas

Positron Emission Tomography (PET) scans can utilize a radioactive tracer, in this case 2-deoxy2-[fluorine-18] fluoro-D-glucose (18F-FDG), to visualize malignant tumors in cancer patients. The uptake was compared to glucose to understand the difference in thermal properties, which contribute to the ability to image the cancerous cells. The uptake of 18F-FDG by cancer cells and the imaging process of positron emission tomography were reviewed from a thermodynamic perspective. Gastrointestinal and neurological imaging techniques were reviewed to understand the role of PET imaging in different areas of the human body.


Advancement Of A 3d Computational Phantom And Its Age Scaling Methodologies For Retrospective Dose Reconstruction Studies, Aashish Gupta Aug 2021

Advancement Of A 3d Computational Phantom And Its Age Scaling Methodologies For Retrospective Dose Reconstruction Studies, Aashish Gupta

Dissertations and Theses (Open Access)

We have used a 3D age-scalable computational phantom for over two decades for retrospective dose reconstruction studies of childhood cancer survivors (CCS) treated with 2D historic radiotherapy (RT). However, our phantom and its age scaling functions (ASF) must be updated so that it can be used in studies that include survivors treated with contemporary RT. We aimed to implement our phantom and its age scaling functions in DICOM format and determine the feasibility of applying our ASFs to accurately scale the whole-body CT-based anatomies.

In the implementation study, we developed Python scripts that model the phantom and ASFs in a …


Remotely Controlled Enzyme Behavior Using Localized Thermal Gradients, Sarah Brown Mar 2021

Remotely Controlled Enzyme Behavior Using Localized Thermal Gradients, Sarah Brown

UNO Student Research and Creative Activity Fair

No existing model describes an identified special case of enzyme behavior when directly stimulated with thermal energy via an RF field.

The ability to remotely influence cellular functions and outcomes is a new approach to targeted medicine. Nano-medicine and biotechnology are the future of medical diagnostics and treatment. The ability to remotely influence cellular functions and outcomes is a new approach to targeted medicine. Direct heating of an enzyme vs bulk heating changes the enzyme activity.

I tested how direct transfer of thermal energy changes rates of enzyme reactions. We created samples of enzymes, attached to ferrous (magnetic) nano-particles, and …


Hyperpolarized Carbon-13 Magnetic Resonance Measurements Of Tissue Perfusion And Metabolism, Keith Michel Dec 2020

Hyperpolarized Carbon-13 Magnetic Resonance Measurements Of Tissue Perfusion And Metabolism, Keith Michel

Dissertations and Theses (Open Access)

Hyperpolarized Magnetic Resonance Imaging (HP MRI) is an emerging modality that enables non-invasive interrogation of cells and tissues with unprecedented biochemical detail. This technology provides rapid imaging measurements of the activity of a small quantity of molecules with a strongly polarized nuclear magnetic moment. This polarization is created in a polarizer separate from the imaging magnet, and decays continuously towards a non-detectable thermal equilibrium once the imaging agent is removed from the polarizer and administered by intravenous injection. Specialized imaging strategies are therefore needed to extract as much information as possible from the HP signal during its limited lifetime.

In …


Pharmacodynamics Of Monoamine Transporter Releasing Agents And Reuptake Inhibitors, Alexa Holloway Jan 2019

Pharmacodynamics Of Monoamine Transporter Releasing Agents And Reuptake Inhibitors, Alexa Holloway

Theses and Dissertations

Ligands of the human monoamine transporters encompass a wide range of both illicit and therapeutic drugs that act upon neural circuitry related to reward, motivation, and the processing of salient stimuli. The present study utilizes two methods for analyzing transporter substrates and inhibitors in order to characterize activity and assess potency. The first measures transient changes in intracellular calcium as a surrogate for transporter activity by harnessing the electrical coupling of monoamine transporters and L-type calcium channels. This is used to analyze novel chimera of the strong hDAT inhibitors methylphenidate and ��-PPP in order to assess the contribution of specific …


Evaluation And Adaptation Of Live-Cell Interferometry For Applications In Basic, Translational, And Clinical Research, Kevin A. Leslie Jan 2018

Evaluation And Adaptation Of Live-Cell Interferometry For Applications In Basic, Translational, And Clinical Research, Kevin A. Leslie

Theses and Dissertations

Cell mass is an important indicator of cell health and status. A diverse set of techniques have been developed to precisely measure the masses of single cells, with varying degrees of technical complexity and throughput. Here, the development of a non-invasive, label-free optical technique, termed Live-Cell Interferometry (LCI), is described. Several applications are presented, including an evaluation of LCI’s utility for assessing drug response heterogeneity in patient-derived melanoma lines and the measurement of CD3+ T cell kinetics during hematopoietic stem cell transplantation. The characterization of mast cells during degranulation, the measurement of viral reactivation kinetics in Kaposi’s Sarcoma, and drug …


Volumetric, Magnetic Resonance-Visible, And Radiation-Sensitive Detectors For Magnetic Resonance Image-Guided Radiation Therapy, Hannah J. Lee Aug 2017

Volumetric, Magnetic Resonance-Visible, And Radiation-Sensitive Detectors For Magnetic Resonance Image-Guided Radiation Therapy, Hannah J. Lee

Dissertations and Theses (Open Access)

VOLUMETRIC, MAGNETIC RESONANCE-VISIBLE, AND RADIATION-SENSITIVE DETECTORS FOR MAGNETIC RESONANCE IMAGE-GUIDED RADIATION THERAPY

Hannah Jungeun Lee

Advisory Professor: Geoffrey S. Ibbott, Ph.D.

Due to the superior soft-tissue contrast of magnetic resonance imaging (MRI) compared to conventional computed tomography (CT) and other on-board imaging techniques, several groups have integrated MRI and radiation treatment machine systems. The advent of MR image-guided radiation therapy (MR-IGRT) using systems, such as the 1.5 MRI – 7 MV linear accelerator (MR-Linac), now allow for improved soft-tissue on-board imaging for patient position and tumor target localization verification and the ability to assess functional biological tissue characteristics with MRI, …


Strategies Of Balancing: Regulation Of Posture As A Complex Phenomenon, Allison Leich Hilbun May 2016

Strategies Of Balancing: Regulation Of Posture As A Complex Phenomenon, Allison Leich Hilbun

Electronic Theses and Dissertations

The complexity of the interface between the muscular system and the nervous system is still elusive. We investigated how the neuromuscular system functions and how it is influenced by various perturbations. Postural stability was selected as the model system, because this system provides complex output, which could indicate underlying mechanisms and feedback loops of the neuromuscular system. We hypothesized that aging, physical pain, and mental and physical perturbations affect balancing strategy, and based on these observations, we constructed a model that simulates many aspects of the neuromuscular system. Our results show that aging changes the control strategy of balancing from …


Characterization Of Low Density Intracranial Lesions Using Dual-Energy Computed To Mography, Jessica L. Nute May 2015

Characterization Of Low Density Intracranial Lesions Using Dual-Energy Computed To Mography, Jessica L. Nute

Dissertations and Theses (Open Access)

Calcific and hemorrhagic foci of susceptibility are frequently encountered on routine brain MR studies. Both etiologies cause variations in local magnetic field strength, leading to dark regions on the MR images that cannot be classified. Single-energy CT (SECT) can be used to identify lesions with attenuation over 100 HU as calcific, however lesions with lower attenuation cannot be reliably identified. While calcific lesions are unlikely to cause harm, hemorrhagic lesions carry a risk of subsequent intracranial bleeding; as such, identification of hemorrhage is vital in preventing the inappropriate use of anticoagulant medications in patients with hemorrhagic lesions.

Given there currently …


New To Ols For Monitoring Gamma Camera Uniformity, Brad K. Lofton Dec 2010

New To Ols For Monitoring Gamma Camera Uniformity, Brad K. Lofton

Dissertations and Theses (Open Access)

Detector uniformity is a fundamental performance characteristic of all modern gamma camera systems, and ensuring a stable, uniform detector response is critical for maintaining clinical images that are free of artifact. For these reasons, the assessment of detector uniformity is one of the most common activities associated with a successful clinical quality assurance program in gamma camera imaging. The evaluation of this parameter, however, is often unclear because it is highly dependent upon acquisition conditions, reviewer expertise, and the application of somewhat arbitrary limits that do not characterize the spatial location of the non-uniformities. Furthermore, as the goal of any …