Open Access. Powered by Scholars. Published by Universities.®

Orthodontics and Orthodontology Commons

Open Access. Powered by Scholars. Published by Universities.®

Orthodontics

Discipline
Institution
Publication Year
Publication
Publication Type
File Type

Articles 61 - 90 of 114

Full-Text Articles in Orthodontics and Orthodontology

Microleakage - The Main Culprit In Bracket Bond Failure?, Ioana Roxana Bordea, Adina Sîrbu, Ondine Lucaciu, Aranka Ilea, Radu Septimiu Câmpian, Doina Adina Todea, Teodora Gabriela Alexescu, Maria Aluaș, Corina Budin, Andreea Simona Pop Apr 2019

Microleakage - The Main Culprit In Bracket Bond Failure?, Ioana Roxana Bordea, Adina Sîrbu, Ondine Lucaciu, Aranka Ilea, Radu Septimiu Câmpian, Doina Adina Todea, Teodora Gabriela Alexescu, Maria Aluaș, Corina Budin, Andreea Simona Pop

Journal of Mind and Medical Sciences

Microleakage is the most common cause of bracket debonding. Moreover, different thermal expansion coefficients between the enamel, the adhesive, and the bracket bases will cause repeated expansion and contraction, adding more stress to the bonding strength. Debonding represents the failure of the adhesion between the brackets and the tooth enamel. The debonding of brackets from the enamel surface is the result of several factors, such as acid-etching and drying, adhesive application, and the time and type of photo activation. The under polymerization process of composite photo activation may lead to early bracket debonding. Objective. The aim of this research …


Comparison Of Patient Factors Influencing The Selection Of An Orthodontist, General Dentist, Or Direct-To-Consumer Aligners For Orthodontic Treatment, Jeffrey C. Olson Jan 2019

Comparison Of Patient Factors Influencing The Selection Of An Orthodontist, General Dentist, Or Direct-To-Consumer Aligners For Orthodontic Treatment, Jeffrey C. Olson

Theses and Dissertations

Purpose: To evaluate the factors that influence potential orthodontic patients choosing between an orthodontist, general dentist, and direct-to-consumer (DTC) aligners for their treatment, and to determine the demand for each provider type.

Methods: An electronic survey was administered to 250 individuals among the general population of adults in the United States. Questions were designed to determine the respondent’s level of interest in pursuing orthodontic treatment with each provider type, evaluate their current level of knowledge concerning provider options, and identify factors influencing their selection. Pearson’s chi-squared test and ANOVA were used to evaluate the factors influencing patients in …


Comparison Of Immediate Vs. Delayed Recall Of Orthodontic Information Following An Electronic Reminder, Michael Lenz Jul 2018

Comparison Of Immediate Vs. Delayed Recall Of Orthodontic Information Following An Electronic Reminder, Michael Lenz

Master's Theses (2009 -)

Patients and parents in dentistry often do not remember important information disclosed during the informed consent process, so improvement in the delivery of information is needed. This study explored the effect of an emailed narrated instructional PowerPoint on the immediate vs. delayed recall and comprehension of informed consent information in orthodontics. Thirty-two subjects were recruited from a university and private practice orthodontic clinic. At the initial visit, subjects were alternately assigned to one of two groups and were presented with a mock orthodontic treatment plan and informed consent presentation for a pretend patient. Immediately following the presentation, the subjects’ verbal …


Evaluation Of Fit For 3d Printed Retainers As Compared To Thermoform Retainers, David J. Cole Jan 2018

Evaluation Of Fit For 3d Printed Retainers As Compared To Thermoform Retainers, David J. Cole

Theses and Dissertations

ABSTRACT

EVALUATION OF FIT FOR 3D PRINTED RETAINERS AS COMPARED TO THERMOFORM RETAINERS

By David Cole, D.M.D.

A thesis submitted in partial fulfillment of the requirements for the degree of Master of Science in Dentistry at Virginia Commonwealth University

Thesis Directors: Eser Tüfekçi, D.D.S., M.S., Ph.D., M.S.H.A.

Professor, Department of Orthodontics

Sompop Bencharit, D.D.S., M.S., Ph.D.

Associate Professor and Director of Digital Dentistry, Department of General Practice

Introduction: Despite recent advances in three-dimensional (3D) printing, little information is available on 3D printed retainers

Methods: Three reference models were used to fabricate traditional vacuum formed, commercially-available vacuum formed, and 3D printed …


Orthodontists’ And Patients’ Preferences In Website Design In The Selection Of An Orthodontic Practice: A Comparative Study, Taylor R. Brown Jan 2018

Orthodontists’ And Patients’ Preferences In Website Design In The Selection Of An Orthodontic Practice: A Comparative Study, Taylor R. Brown

Theses and Dissertations

Objective: To determine which website characteristics are preferred by orthodontists, adult patients, and parents of patients.

Materials and Methods: 1,000 active members of the American Association of Orthodontists and 750 active orthodontic patients/parents were sampled. Participants rated the importance of website characteristics, indicated presence of those characteristics on the current website, and ranked sample website images. Preferences were compared between orthodontist and the patient/parent group using t-tests and sample websites were compared using ANOVA models and Tukey’s adjusted post-hoc tests. Significance level was set at 0.05.

Results: 11 of the 16 website features showed significant differences between patients/parents and orthodontists. …


Direct Visual Approximation Of Arch Length Discrepancy And Cephalometric Measurements, Bradley J. Wurm Jul 2017

Direct Visual Approximation Of Arch Length Discrepancy And Cephalometric Measurements, Bradley J. Wurm

Master's Theses (2009 -)

Introduction: Arch length discrepancy and cephalometric analysis are critical components of orthodontic treatment planning. Both have direct effects on the decision to extract teeth or not and treatment mechanics as well. Visual approximation is the most common method used to analyze arch length discrepancy among practitioners. Current trends show a decrease in the amount of orthodontists completing a cephalometric analysis. Previous studies have shown a tendency for orthodontists to overestimate the degree of crowding when visually approximating on dental casts. No previous study has assessed the ability to visually approximate cephalometric angle measurements. The purpose of this survey was to …


Orthodontists' And Parents' Perspective Of Occlusion In Varying Anterior-Posterior Positions: A Comparative Study, David H. Lindsey Jan 2017

Orthodontists' And Parents' Perspective Of Occlusion In Varying Anterior-Posterior Positions: A Comparative Study, David H. Lindsey

Theses and Dissertations

Objective: The purpose was to compare orthodontists’ and parents’ perception of orthodontic treatment outcomes in the anterior-posterior (AP) dimension. Assessment of treatment time and compliance were also investigated.

Material and Methods: Parallel surveys for orthodontists (n=1000) and parents (n=750) displayed occlusions from 3 mm Class III (Cl III:3) to 3 mm Class II. Participants rated occlusal relationships on a 100 mm VAS from least to most acceptable (0-100).

Results: 233 orthodontists (23%) and 243 parents (32%) responded. Orthodontists (mean=93.9, 25.9) and parents (mean=80.7, 40.9) rated Class I (Cl I) occlusion most and Cl III:3 least acceptable. No significant difference was …


An Investigation Of Surface Characteristics Of Enamel Treated With Infiltrative Resin: A Scanning Electron Microscopy Study, Danielle E. Easterly Jan 2017

An Investigation Of Surface Characteristics Of Enamel Treated With Infiltrative Resin: A Scanning Electron Microscopy Study, Danielle E. Easterly

Theses and Dissertations

AN INVESTIGATION OF SURFACE CHARACTERISTICS OF ENAMEL TREATED WITH INFILTRATIVE RESIN: A SCANNING ELECTRON MICROSCOPY STUDY

Danielle E. Easterly, Doctorate of Dental Surgery.

A thesis submitted in partial fulfillment of the requirements for the degree of Master of Science in Dentistry at Virginia Commonwealth University.

Virginia Commonwealth University. 2017.

Director: Dr. Eser Tüfekçi

D.D.S., M.S., Ph.D., M.S.H.A.

Objective: To evaluate the microstructural changes of a resin infiltrant (ICON®, DMG America LLC, Englewood, NJ) after six months of simulated toothbrushing.

Materials and Methods: Ten extracted third molars (n=10) were collected. Artificial white spot lesions were created and resin applied. Environmental SEM …


Work-Related Musculoskeletal Disorders Among Dentists And Orthodontists, Natalie R. La Rochelle Jan 2017

Work-Related Musculoskeletal Disorders Among Dentists And Orthodontists, Natalie R. La Rochelle

Theses and Dissertations

WORK-RELATED MUSCULOSKELETAL DISORDERS AMONG DENTISTS AND ORTHODONTISTS

A thesis submitted in partial fulfillment of the requirements for the degree of

Master of Science in Dentistry at Virginia Commonwealth University.

by

Natalie R. La Rochelle

Thesis Director: Dr. Eser Tüfekçi, D.D.S., M.S., Ph.D., M.S.H.A.

Professor, Department of Orthodontics

Virginia Commonwealth University

Richmond, Virginia

May 2017

The practice of dentistry is physically demanding due to static and dynamic postures sustained daily throughout careers. Previous literature suggests that work-related musculoskeletal disorders (WMSD) are not solely the result of work habits, but also due to the individual, his or her physical makeup, genetics, and …


Comparison Of Intraoral And Extraoral Scanners On The Accuracy Of Digital Model Articulation, Jason L. Porter Jan 2017

Comparison Of Intraoral And Extraoral Scanners On The Accuracy Of Digital Model Articulation, Jason L. Porter

Theses and Dissertations

Introduction: Orthodontists increasingly rely on digital models in clinical practice. The ability of modern scanners to articulate digital models must be scientifically evaluated. Methods:Twenty five digital articulated models were produced from four digital scanners in five experimental groups. The resulting inter-arch measurements were compared to the gold standard. An acceptable range of 0.5mm more or less than the gold standard was used for evaluation. Results: iTero® and iTero® Element yielded all acceptable inter-arch measurements. The 3M™ True Definition and Ortho Insight 3D® with Regisil® bite registration produced four of six acceptable inter-arch measurements. The Ortho Insight 3D® with Coprwax ™ …


Thermal Properties Of Copper Nickel-Titanium Orthodontic Archwires, Joshua Gilbert Jul 2016

Thermal Properties Of Copper Nickel-Titanium Orthodontic Archwires, Joshua Gilbert

Master's Theses (2009 -)

Introduction: Copper Nickel-Titanium (CuNiTi) is a relatively new composition of Nickel-Titanium (NiTi) archwires that was originally patented in 1991 as part of the Ormco line of wires. The patent has now recently expired and many other orthodontic companies are making their own CuNiTi wires. Advertisement claims have focused on the laboratory benefits of adding Copper (Cu) to the NiTi, however few independent laboratory testings have been conducted on these new wires to verify claims. The purpose of this study was to conduct thermal analysis of CuNiTi for all currently available wires in two Austenite Finish (Af) variants and two commonly …


Mechanical Properties Of Copper-Nickel-Titanium Archwires, Margaret Amelia Rosen Jul 2016

Mechanical Properties Of Copper-Nickel-Titanium Archwires, Margaret Amelia Rosen

Master's Theses (2009 -)

Introduction: The initial phase of orthodontic therapy relies on flexible wires, usually composed of a nickel-titanium alloy, to apply a substantially constant load during tooth movement. Copper has been added to nickel-titanium archwires, resulting in an alloy with potential clinical advantages such as a lower stress hysteresis. Many orthodontic companies claim that their copper-nickel-titanium manufacturing process allows for the production of more consistent transition temperatures in the wires, allowing the orthodontist to customize treatment to various patients based on the force level needed. There are currently many manufacturers of these wires, creating a wide range of copper-nickel-titanium archwires from which …


The Effect Of Orthodontic Appliances On The Evaluation Of The Professionalism And Esthetics Of An Adult Employee, Laura Hanson Vaccariello Jul 2016

The Effect Of Orthodontic Appliances On The Evaluation Of The Professionalism And Esthetics Of An Adult Employee, Laura Hanson Vaccariello

Master's Theses (2009 -)

This study explored the influence of fixed and removable orthodontic appliances on participants’ ratings of the job performance, intelligence, and attractiveness of an adult female. Ninety-four adult subjects were recruited from the Graduate School of Management at Marquette University. Each subject received an identical employee performance review with an attached photograph of a female employee. The smile of the photo was manipulated to represent one of four conditions: no orthodontic appliance, a metal orthodontic appliance, a ceramic orthodontic appliance, or a clear aligner. Subjects then rated the employee on three continuous Likert scales. Ratings of job performance, intelligence, and attractiveness …


Perception Of Differences In Lip Profile Between 2-D And 3-D, Andrew Hansen Jan 2016

Perception Of Differences In Lip Profile Between 2-D And 3-D, Andrew Hansen

Theses and Dissertations

Past studies evaluating the esthetics of orthodontic treatment have been done using 2-D images. New 3-D imaging offers an improved, real-life representation of a subject. The purpose of this study was to determine how laypeople perceived differences in lip position (flat versus ideal lip fullness) in 2-D compared to 3-D.

3dMD images of 8 Caucasian subjects were adjusted to an ideal and flat lip position in 3-D and then in 2-D from the profile view. 2 surveys were created with paired ideal and flat images on the screen, either in 2-D or 3-D, and evaluators were asked to choose which …


Twitter Analysis Of The Orthodontic Patient Experience With Braces Versus Invisalign, Daniel A. Noll Jan 2016

Twitter Analysis Of The Orthodontic Patient Experience With Braces Versus Invisalign, Daniel A. Noll

Theses and Dissertations

The purpose of this study was to examine the orthodontic patient experience with braces compared to Invisalign® by means of a large-scale Twitter sentiment analysis. A custom data collection program was created to collect tweets containing the words “braces” or “Invisalign.” A hierarchal Naïve Bayes sentiment classifier was developed to sort the tweets into one of five categories: positive, negative, neutral, advertisement, or not applicable. Among the 419,363 tweets applicable to orthodontics collected, users posted significantly more positive tweets (61%) than negative tweets (39%) (p-value = ® tweets (p-value=0.4189). In conclusion, Twitter users express more positive than negative sentiment …


The Direct Effect Of Low-Magnitude High-Frequency Mechanical Vibration On Osteoclast Formation From Raw267.4 Monocytes, Maxwell Antonio Abraham Jul 2015

The Direct Effect Of Low-Magnitude High-Frequency Mechanical Vibration On Osteoclast Formation From Raw267.4 Monocytes, Maxwell Antonio Abraham

Master's Theses (2009 -)

Low-magnitude high-frequency (LMHF) mechanical vibration has been demonstrated to enhance bone formation possibly through inhibition of osteoclastogenesis of bone. Earlier research has demonstrated osteoclast formation from RAW264.7 monocytes was inhibited by a chewing cycle mimicking vibration through inhibition of dendritic cell-specific transmembrane protein (DC-STAMP). We hypothesize that application of LMHF mechanical vibration directly inhibits osteoclast formation from RAW264.7 monocytes in a frequency dependent manner. RAW264.7 monocytes (ATCC) were cultured in alpha minimal essential medium (MEM) with 10% fetal bovine serum (FBS ) and 1% Pen/Strep at 37°C and 5% CO2. The cells were seeded at a density of 2000 cells/well …


Influence Of Fluoride And Stress On The Electrochemical Properties Of Nickel-Titanium Coils, Ashley Barnes Jul 2015

Influence Of Fluoride And Stress On The Electrochemical Properties Of Nickel-Titanium Coils, Ashley Barnes

Master's Theses (2009 -)

The aim of this study was to examine the effects of fluoride and stress on the electrochemical properties of nickel-titanium coils. Forty Dentsply GAC NiTi coils were divided into four groups of ten and individually tested. Twenty coils were placed in a solution of artificial saliva, where ten of the twenty were compressed and the other ten were not stressed. The other twenty coils were placed in a 1500 ppm NaF solution, where ten were compressed and ten were not. The coils were connected to a computer driven potentiostat and three tests were conducted: open circuit potential monitoring for 2 …


Influence Of Fluoride And Stress On The Mechanical Properties Of Nickel-Titanium Coils, Jennifer Ann Fehrman Roloff Jul 2015

Influence Of Fluoride And Stress On The Mechanical Properties Of Nickel-Titanium Coils, Jennifer Ann Fehrman Roloff

Master's Theses (2009 -)

Objective: The objective of this study was to determine the influence of fluoride and stress on the mechanical properties of nickel-titanium open coil springs. Materials and Methods: Sentalloy nickel-titanium open coil springs (15 mm length) were divided into five groups. A control group was tested mechanically in as-received condition. The other four experimental groups were exposed to artificial saliva (Fusayama-Meyer solution) at 37oC for 12 weeks in a 2x2 factorial design with fluoride exposure and stress (compression) as the two factors. Those springs which were under compression were held at 5 mm in length for the entirety of the testing …


Mechanical Properties And Patient Perceptions Of Commonly Used Clear Aligner Systems As-Received And After Clinical Use, Lauren Evan Montoure Teske Jul 2015

Mechanical Properties And Patient Perceptions Of Commonly Used Clear Aligner Systems As-Received And After Clinical Use, Lauren Evan Montoure Teske

Master's Theses (2009 -)

Background/Objectives: This study aimed to investigate the viscoelastic properties of two clear aligner systems, Invisalign (Align Technology, Inc, Santa Clara, CA, USA) and Simpli5 (Allesee Orthodontic Appliances, Sturtevant, WI, USA), and determine if there was a difference after use. A survey assessed patients’ perceptions of the aligner material and post-treatment satisfaction. Materials/Methods: Mandibular aligners were collected from two patients after 2-3 weeks of use (n=6). Duplicate, unused aligners were obtained for each patient (n=6). Dynamic mechanical analysis (DMA) characterized the viscoelastic properties of the materials. Three tests were done on separate specimens: frequency scan (0.1-10 Hz under 25 μm displacement …


Restoring Lateral Incisors And Orthodontic Treatment: Perceptions Among General Dentists And Othodontists, Matthew A. Sandretti, Bhavna Shroff, Steven J. Lindauer, Al M. Best Jan 2015

Restoring Lateral Incisors And Orthodontic Treatment: Perceptions Among General Dentists And Othodontists, Matthew A. Sandretti, Bhavna Shroff, Steven J. Lindauer, Al M. Best

Theses and Dissertations

The purpose of this study was to identify and compare preferences and perceptions of orthodontists and general dentists when restoring peg-shaped lateral incisors. The investigation sought to summarize these preferences with regard to treatment planning, tooth preparation and interdisciplinary communication. A pair of mailed and electronic surveys was distributed to 1,500 general dentists and orthodontists, respectively. The results indicated that general dentists perceived that general dentists held the primary decision-making responsibility, while orthodontists disagreed (P<0.0001). Orthodontists prioritized the treatment goals of Class I canine relationship and overbite/overjet more significantly than general dentists, whom valued tooth proportions more highly (P<0.0001). General dentists reported receiving significantly less input than orthodontists report seeking (P<0.0001).The consensus of both groups showed that the tooth should be positioned centered mesiodistally and guided by the gingival margins incisogingivally. Both groups agree that orthodontists must improve communication to improve treatment results.


Microstructure And Mechanical Properties Of Nickel-Free And Nickel-Containing Stainless Steel Orthodontic Wires, Amanda Olejniczak Jul 2014

Microstructure And Mechanical Properties Of Nickel-Free And Nickel-Containing Stainless Steel Orthodontic Wires, Amanda Olejniczak

Master's Theses (2009 -)

Introduction: In orthodontics, contact dermatitis caused by nickel allergy should be of concern with the number of nickel-containing appliances and wires used. Stainless steel archwires are commonly used throughout orthodontic treatment. With the release of nickel from these wires, some manufacturers have turned to nickel-free stainless steel alternatives. The goal of this research was to compare nickel-free stainless steel with traditional stainless steel archwires with regard to mechanical properties and microstructure. Materials and Methods: Nickel-free stainless steel and regular stainless steel archwires from four companies were included. Five random samples of each wire, vertically mounted in fast-set acrylic, were indented …


Dimensional Changes Of Facial Soft Tissue Associated With Rapid Palatal Expansion, Peter Charles Longo Jul 2014

Dimensional Changes Of Facial Soft Tissue Associated With Rapid Palatal Expansion, Peter Charles Longo

Master's Theses (2009 -)

Introduction: Orthodontic treatment demands excellent outcomes in both function and esthetics. Despite the popularity of rapid palatal expansion in orthodontic treatment, few studies have examined its consequences on facial soft tissue using direct anthropometric measurements. The primary goal of this study was to determine facial soft tissue changes immediately following rapid palatal expansion. Materials and Methods: Twenty-eight patients (age range, 8-17 years) attending Marquette Dental School Orthodontic Post-Graduate Clinic were enrolled in the study. Facial soft tissue measurements were taken with digital calipers at two separate time points (T0: initial exam and T1: thirty days following expansion); measurements were recorded …


An Investigation Into The Bonding Properties Of New Generation Ceramic Brackets As Compared To A Stainless Steel Bracket, Ami Inoue Jul 2014

An Investigation Into The Bonding Properties Of New Generation Ceramic Brackets As Compared To A Stainless Steel Bracket, Ami Inoue

Master's Theses (2009 -)

Introduction: More patients are seeking esthetic alternatives for their orthodontic treatment options, which has led to increased use of ceramic brackets in recent years. These brackets were marketed before independent scientific research was completed. Many of the early ceramic brackets used a silane coupling agent to allow for a chemical bond between the bracket and the adhesive resin. Early reports from clinicians of increased bond strengths and iatrogenic tooth damage after bracket removal were common. Manufacturers have made changes to their base designs, relying more on mechanical retention for bond strength. The goal of this study was to test the …


Frictional Forces Of A Fixed, Esthetic Orthodontic Appliance System, Brady Michael Nance Dec 2012

Frictional Forces Of A Fixed, Esthetic Orthodontic Appliance System, Brady Michael Nance

UNLV Theses, Dissertations, Professional Papers, and Capstones

Purpose: The demands of an all esthetic fixed orthodontic appliance system are ever increasing in today's world. Frictional values of an esthetic, fixed orthodontic appliance system are needed to evaluate their clinical effectiveness for orthodontic treatment. The aim of this study is to evaluate the frictional values of various esthetic orthodontic archwires ligated to an esthetic orthodontic bracket.

Methods: Three types of stainless steel and nickel titanium alloy (niti) esthetic orthodontic archwires (epoxy, poly, plastic) in four sizes (.016, .018, .017 x .025, .019 x .025 inches) were ligated to both a stainless steel bracket system and a ceramic (esthetic) …


Effectiveness Of Resin Infiltration And Mi Paste Cpp-Acp In Masking White Spot Lesions, Melissa Wu Bailey Aug 2012

Effectiveness Of Resin Infiltration And Mi Paste Cpp-Acp In Masking White Spot Lesions, Melissa Wu Bailey

Loma Linda University Electronic Theses, Dissertations & Projects

The development of decalcification around orthodontic brackets and bands, commonly called white spot lesions (WSLs), is often observed in patients with poor oral hygiene during treatment (Behnan et al., 2010, Rodgers et al., 2010). In many instances, these WSLs continue to be visible after the removal of fixed appliances and after natural remineralization. The purpose of this in vitro study was to compare the effectiveness of two treatment modalities, resin infiltration (RI) and Casein Phosphopeptide Amorphous Calcium Phosphate (CPP-ACP), at improving the light reflectivity and thus the appearance of WSLs using spectrophotometric analysis. Sixty extracted human third molars were partially …


Evaluation Of Apical, Coronal And Occlusal Form Diffrences With Conventional Orthodontic Treatment, Tamar Sardarian Aug 2012

Evaluation Of Apical, Coronal And Occlusal Form Diffrences With Conventional Orthodontic Treatment, Tamar Sardarian

Loma Linda University Electronic Theses, Dissertations & Projects

Introduction: Cone-beam computed tomography (CBCT) can be used to accurately identify dental landmarks in order to detect changes in dental arch forms. Purpose: The objective of this study was to determine how apical, coronal and occlusal arch forms change following orthodontic treatment with fixed appliances and to establish a base for future studies. Material and Methods: Maxillary and mandibular apical, coronal and occlusal landmarks of 27 subjects were selected on their respective CBCT images at two time points: pre-orthodontic treatment (T1) and post-orthodontic treatment (T2). Comparisons were made between the two time points to evaluate how each arch form changed …


Effect Of Gingival Margin Design On Retention Of Thermoformed Orthodontic Aligners, Daniel P. Cowley Aug 2012

Effect Of Gingival Margin Design On Retention Of Thermoformed Orthodontic Aligners, Daniel P. Cowley

UNLV Theses, Dissertations, Professional Papers, and Capstones

Purpose: The aim of this study was evaluate the effect of gingival margin design (scalloped vs. straight cut at gingival zenith vs. straight cut 2mm above gingival zenith) on the retention of thermoformed aligners. Retention of aligners is a critical requirement for efficient tooth movement.

Methods: Two thermoform aligner materials were used, Invisacryl A and Invisacryl C, in 0.040 mil (1mm) thickness. Six aligner designs were fabricated for each of the two aligner materials (12 total aligner designs). Aligner designs are scalloped, straight cut at gingival zenith (0mm), and straight cut 2mm above gingival zenith on a model with attachments. …


Three-Dimensional Force Systems Produced By Vertical V-Bends In An Arch Wire, Raja Shah Jul 2012

Three-Dimensional Force Systems Produced By Vertical V-Bends In An Arch Wire, Raja Shah

Master's Theses

No abstract provided.


New High Intensity Light-Emitting Diode (Led) Curing Lights: An In Vitro Evaluation Of Increased Power Density At Reduced Curing Times, Jeff Mirrielees Jan 2012

New High Intensity Light-Emitting Diode (Led) Curing Lights: An In Vitro Evaluation Of Increased Power Density At Reduced Curing Times, Jeff Mirrielees

MUSC Theses and Dissertations

Introduction: The purpose of this study was to evaluate two new light-emitting diode (LED) curing lights with increased power densities at reduced curing times. Methods: Ninety extracted bovine incisors were examined in vitro. The incisors were divided into six test groups and metallic adhesive pre-coated brackets were bonded using either the Valo Otho (Opal Orthodontics, Ultradent) @ 3200 mW/ cm 2 or the Ortholux Luminous {3M Unitek)@ 1600 mW/ cm 2 at curing intervals of 3-, 6-, or 12-seconds. The samples were stored for 24 hours in 37 degree Celsius water and debonded. Brackets were tested using an MTS Mini-Bionix …


Effects Of Synthetic Cortical Bone Thickness And Force Vector Application On Temporary Anchorage Device Pull-Out Strength As Related To Clinical Perspectives Of Practicing Orthodontists, Ira Rothstein Dec 2011

Effects Of Synthetic Cortical Bone Thickness And Force Vector Application On Temporary Anchorage Device Pull-Out Strength As Related To Clinical Perspectives Of Practicing Orthodontists, Ira Rothstein

Student Theses, Dissertations and Capstones

December 2011.

A thesis submitted to the College of Dental Medicine of Nova Southeastern University of the degree of Master of Science in Dentistry.

Background: Temporary anchorage devices (TADs) provide a versatile means by which orthodontic anchorage can be established without the need for patient compliance and complex force systems. Their use is predicated on their ability to remain stable throughout the course of treatment in which they are needed. This has been shown to be the result of "primary stability" which is achieved through mechanical interlocking of the screw threads with the surrounding bone immediately upon placement. Therefore, evaluating …