Open Access. Powered by Scholars. Published by Universities.®
- Institution
-
- The British University in Egypt (22)
- Association of Arab Universities (15)
- Loma Linda University (11)
- Saint Joseph University of Beirut (11)
- Universitas Indonesia (9)
-
- LSU Health New Orleans (6)
- A.T. Still University (5)
- City University of New York (CUNY) (3)
- Marquette University (3)
- Virginia Commonwealth University (3)
- West Virginia University (3)
- Beirut Arab University (2)
- Roseman University of Health Sciences (2)
- University of Connecticut (2)
- University of the Pacific (2)
- University of AlKafeel (1)
- University of Malaya (1)
- University of Nebraska - Lincoln (1)
- University of Nebraska Medical Center (1)
- Keyword
-
- Prosthodontics (10)
- Zirconia (6)
- Dental materials (4)
- PEEK (4)
- CAD/CAM (3)
-
- Implant (3)
- Sandblasting (3)
- Thermocycling (3)
- Translucency (3)
- Accuracy (2)
- Ceramic (2)
- Color (2)
- Color stability (2)
- Enamel opacity (2)
- Immediate implant placement (2)
- Modulus of elasticity (2)
- Molar incisor hypomineralization (2)
- Overdenture (2)
- Surface roughness (2)
- Surgical guide (2)
- Transillumination (2)
- 3D files (1)
- 3D printing (1)
- 3D tooth position (1)
- 3D-Printed; Color Change; Computer-Aided Design; Denture; Polymethyl Methacrylate; Staining. (1)
- Acetal (1)
- Adaptation (1)
- Additive manufacturing (1)
- Additive manufacturing Accuracy Lithium Disilicate CAD CAM (1)
- Adhesives; Aging; Composite Resin; In Vitro Tests; Mechanical Test; Tensile Strength. (1)
- Publication Year
- Publication
-
- Dentistry (22)
- Future Dental Journal (15)
- International Arab Journal of Dentistry (11)
- Loma Linda University Electronic Theses, Dissertations & Projects (11)
- Journal of Dentistry Indonesia (8)
-
- School of Dentistry Faculty Publications (6)
- MOSDOH Faculty Publications (5)
- Graduate Theses, Dissertations, and Problem Reports (ETD) (3)
- Publications and Research (3)
- Theses and Dissertations (3)
- Annual Research Symposium (2)
- BAU Journal - Creative Sustainable Development (2)
- Bachelors’ Theses (2)
- Master's Theses (2)
- Department of Mechanical and Materials Engineering: Dissertations, Theses, and Student Research (1)
- Excellence Day (1)
- Maaen Journal for Medical Sciences (1)
- Makara Journal of Science (1)
- Master's Theses (2009 -) (1)
- Oral Health (1)
- Student Works (2020-2029) (1)
- Theses & Dissertations (1)
- Publication Type
Articles 91 - 103 of 103
Full-Text Articles in Dental Materials
In Vivo Measurement Of Color Relationships Between The Maxillary Central Incisor And Canine As A Function Of Age, Marie E. Falcone
In Vivo Measurement Of Color Relationships Between The Maxillary Central Incisor And Canine As A Function Of Age, Marie E. Falcone
Master's Theses
Abstract
Introduction
It has long been taught that the basic shade (hue) of the patient can be taken from the canine (i.e. that tooth thought to have the highest chroma of a particular hue) and then that hue can be applied to other anterior teeth but at a lower chroma. However, this concept does not appear to derive from published measurements or observations. This study documented the color relationship between in vivo maxillary central incisors and canines to examine: (1) whether they share the same hue, but have different chromas (as commonly taught); and, (2) whether color differences (∆E values) …
The Effect Of Auxiliary Preparation Elements On The Resistance Form Of Complete Metal Crowns, Mostafa Nazari
The Effect Of Auxiliary Preparation Elements On The Resistance Form Of Complete Metal Crowns, Mostafa Nazari
Loma Linda University Electronic Theses, Dissertations & Projects
This study measured the resistance to dislodgment of complete metal crowns when they were fabricated for tooth preparations lacking resistance form. These preparations were modified with four different auxiliary preparation features.
An Ivorine mandibular first molar was prepared on a milling machine with the following characteristics: 20 degrees of total occlusal convergence (TOC), 360 degrees shoulder finish line of 1.0 mm width, and axial wall of reduced height offering no geometric resistance form. The following tooth preparation modifications were studied:
- Two proximal grooves (two lingually positioned grooves, one on the mesial and one on the distal surface) (design B) (Figures …
Effect Of Auxiliary Preparation Elements On Resistance Form Of Complete Crowns, Manuel H. Guevara
Effect Of Auxiliary Preparation Elements On Resistance Form Of Complete Crowns, Manuel H. Guevara
Loma Linda University Electronic Theses, Dissertations & Projects
This study compared the effectiveness of six different auxiliary preparation elements on the resistance to lateral dislodgment of complete crown preparation lacking resistance form.
An ivorine mandibular first molar was prepared with the following characteristics: 20° TOC, 360° shoulder finish line of 1.0 mm width and axial wall of reduced height offering no geometric resistance form (Group A: control). Preparation modifications were Group B: MD grooves, Group C: BL groves (sic), Group D: MDBL grooves, Group E: MD small boxes, Group F: MD large boxes and Group G: 8° TOC at the cervical 2 mm of the axial walls. Ten …
Immediate Loading Of Unsplinted Implants In The Anterior Mandible For Overdentures, Phillip Roe
Immediate Loading Of Unsplinted Implants In The Anterior Mandible For Overdentures, Phillip Roe
Loma Linda University Electronic Theses, Dissertations & Projects
In this one-year prospective study, eight completely edentulous patients were selected from the Loma Linda University School of Dentistry (LLUSD) patient population to participate. There were five male and three female patients, between the ages of 58 and 82 (mean age of 69.1 years). All participants received new maxillary and mandibular complete dentures prior to implant placement. Two 4.0 mm x 13 mm threaded implants with a fluoride-modified, micro-roughened, titanium surface were placed mesial to each mandibular canine position. Locator abutments were connected and torqued to 25 Ncm and primary closure was achieved with a nonresorbable suture material. The Locator …
Short-Term Clinical Evaluation Of Nobelreplace® Tapered Groovy Implant, Manouchehr Pouresmail
Short-Term Clinical Evaluation Of Nobelreplace® Tapered Groovy Implant, Manouchehr Pouresmail
Loma Linda University Electronic Theses, Dissertations & Projects
The purpose of this clinical investigation was to make comparisons and to achieve estimates of the short-term implant success, marginal bone resorption, and soft tissue responses around the immediately loaded NobelReplace® Tapered groovy implant (with groove on a rough collar portion) as compared to an implant without a groove on the collar (Replace®Select Tapered). This was a randomized controlled and prospective investigation in which subjects were consecutively included according to strict inclusion/exclusion criteria. Single stage procedure was used with immediate function. Seventeen subjects were recruited, and were randomly divided in two groups. Each group was received the predetermined type of …
An In-Vitro Investigation Of The Physical Properties Of Alginate Alternatives, Rishi Dinesh Patel
An In-Vitro Investigation Of The Physical Properties Of Alginate Alternatives, Rishi Dinesh Patel
Loma Linda University Electronic Theses, Dissertations & Projects
The purpose of this study was to evaluate the detail reproduction, gypsum compatibility and linear dimensional change of three recently introduced irreversible hydrocolloid (alginate) alternatives. The materials that were tested are Position Penta Quick® (3M ESPE™), Silgimix® (Sultan Dental) and Alginot® (Kerr™). These materials were tested in accordance with ANSI/ADA Specification No. 18 for Alginate Impression Materials and No. 19 for Dental Elastomeric Impression materials. The irreversible hydrocolloid impression material Jeltrate Plus antimicrobial® (Dentsply Caulk™) served as the control.
MATERIALS AND METHODS: The ADA specification die was used to undertake the testing of the new materials. The parameters of detail …
Immediate Provionalization Of Single Threaded Oxidized Implants On Maxillary Premolars Healed Sites: One-Year Study, Kiyotaka Umezu
Immediate Provionalization Of Single Threaded Oxidized Implants On Maxillary Premolars Healed Sites: One-Year Study, Kiyotaka Umezu
Loma Linda University Electronic Theses, Dissertations & Projects
Osseointegrated endosseous implants have been widely used and become a predictable treatment option for completely and partially edentulous patients. The viability and predictability of this treatment modality have been supported with the high success rates in numerous studies. Clinical guideline requires a healing period of 3 to 6 months without functional loading to achieve osseointegration with machine surface implants. Therefore, numerous studies on immediately loaded implants have been conducted in an attempt to minimize or eliminate this healing period. The purpose of this study was to evaluate the success rate of the immediately provisionalized oxidized-surface implants in healed sites supporting …
Immediate Provisionalization Of Single 3.0 Mm Diameter Implant In Maxillary And Mandibular Anterior Region, Kotaro Oyama
Immediate Provisionalization Of Single 3.0 Mm Diameter Implant In Maxillary And Mandibular Anterior Region, Kotaro Oyama
Loma Linda University Electronic Theses, Dissertations & Projects
Immediate provisionalization of single implants with standard (3.75 - 4.5 mm) and wide diameter (> 4.5 mm) has been well documented. When the space is limited, small diameter implants (3.0 mm) must be used. Although high success rates have been reported, they were limited to healed site and were placed as staged procedures. The purpose of this prospective study was to evaluate the success rate and peri-implant tissue response of small diameter (3.0 mm) implants undergoing immediate provisionalization in the esthetic area.
Eleven patients who had missing maxillary lateral incisor(s) and/or mandibular incisor(s) participated in this study. Thirteen 3.0 mm …
Effect Of Gutta Percha On The Retention Of A Post Using Different Cements, Saeda H. Basta
Effect Of Gutta Percha On The Retention Of A Post Using Different Cements, Saeda H. Basta
Loma Linda University Electronic Theses, Dissertations & Projects
This study evaluated the effect of residual gutta percha on the retention strength of prefabricated post cemented with four different cements. Forty intact mandibular single canal canines or premolars were selected for standardized size and quality, endodontically treated, and decoronated to the cementoenamel junction. A post space was prepared to accommodate Para post XP size 4 (Coltene, Whaledent Inc., Cuy Falls, Ohio) to a depth of 8 mm. The Obtura heated gutta percha system was used to inject a very thin line of gutta percha along one lateral wall to the depth of the future post. Forty obturated teeth were …
Evaluation Of Three Bonding Agents In The Repair Of Fractured Veneered Stainless Steel Crowns, Jennifer Liane Hoffer
Evaluation Of Three Bonding Agents In The Repair Of Fractured Veneered Stainless Steel Crowns, Jennifer Liane Hoffer
Loma Linda University Electronic Theses, Dissertations & Projects
Dentists have long been challenged with finding an esthetic yet durable treatment option to restore badly carious anterior teeth. Veneered stainless steel crowns have become one of these options, but these restorations often return with the veneer fractured. To help restore esthetics, the crown may either be replaced or the veneer must be repaired. The purpose of this study was to evaluate the use of three bonding agents (PQ1, C&B Metabond, and Panavia) and one restorative material (Filtek Z250, 3M) in the repair of these fractured stainless steel crown veneers. The clinical significance is to determine the best methods of …
Accuracy Of The Indirect Method Evaluated By Mercury Micromeasurement, Estol C. Pruett
Accuracy Of The Indirect Method Evaluated By Mercury Micromeasurement, Estol C. Pruett
Loma Linda University Electronic Theses, Dissertations & Projects
Although the indirect method for preparing dental castings has been in use for over forty-five years, very little information has appeared in dental literature relative to its accuracy. The development of a precise and quantitative method for determining the adaptation of wax patterns or castings was necessary before such an evaluation could be considered valid. It was felt the Mercury Micromeasurement test, devised in 1958 by Hollenback, should meet these requirements. A description of the test had been published. However, at the time the project was begun, no data had appeared in the literature.
In order to establish a standard …
The Modern Trend Of Prosthetics, Arlo M. Rahrig
The Modern Trend Of Prosthetics, Arlo M. Rahrig
Bachelors’ Theses
This is a short discussion on the technique of denture construction which is being employed by the most prominent and successful prosthetists of today. Since it is annoying to have a technical investigation misinterpreted because of lack of uniformly applied terms, there is a necessity to annex concise definitions to the technique. Thus a strenuous effort will be made to closely adhere to the original meaning of standard terms and to modify these or add to them as little as possible when they are comprehensive. In the past it was customary to include into an articulator technique many bombastic theories …
Celluloid And Hecolite Dentures, Gilbert Clair Wildman
Celluloid And Hecolite Dentures, Gilbert Clair Wildman
Bachelors’ Theses
Celluloid gives the most natural appearance of all the plastic vegetable bases used in making dentures. It closely resembles porcelain in the translucent live-tissue color of the mucous membrane and gums. In some cases, it proves very satisfactory while it discolors and quickly disintegrates in some mouths. Vulcanite is usually more durable. The value of celluloid depends upon the care given it by the possessor and the manipulation of the material while under construction.