Articles 211 - 240 of 413

Full-Text Articles in Dentistry

Flexure Strength Of Methacrylate- And Ormocer-Based Bulk Fill Resin Composites: Effect Of Material Thickness And Distance To Photo-Polymerization Device., Sara Adel Botros Jan 2021

Flexure Strength Of Methacrylate- And Ormocer-Based Bulk Fill Resin Composites: Effect Of Material Thickness And Distance To Photo-Polymerization Device., Sara Adel Botros

Dentistry

This study evaluated the effect of thickness and photo-polymer- ization distance on flexure strength of two bulk fill resin compo- sites. In total, 96 rectangular-shaped resin composite bars were divided into eight experimental groups (n ¼ 12/group) according to the three experimental factors; Factor 1: Material (X-tra fil and Admira Fusion X-tra), Factor 2: Thickness (2 mm and 4 mm) and Factor 3: photo-polymerization distance (2 mm and 8 mm). The bars were prepared with fixed 2 mm width and 2 mm length but differed in thickness (2 mm or 4 mm). The bars were light cured either at 2 …


Accuracy Of Digital Impressions At Varying Implant Depths: An In-Vitro Study, Vivia Sequeira Jan 2021

Accuracy Of Digital Impressions At Varying Implant Depths: An In-Vitro Study, Vivia Sequeira

Graduate Theses, Dissertations, and Problem Reports (ETD)

Introduction: Implants placed at variable depths may vary the amount of visible scannable surface of a scan body. Intraoral scanner technology uses advanced optical principles to record the surface of the scan body to accurately capture the implant position.

Purpose: To investigate the effect implant placement depth has on the accuracy of digital implant impressions using an intraoral scanner.

Materials & Methods: A partially edentulous gypsum master model was fabricated to allow the positioning of a single implant analog at different depths. Four groups based on the planned implant depths of 0, 3, 6 and 7mm and corresponding visibility of …


Accuracy Of Implant Placement Utilizing Stereolithographic Guides Printed With And Without Cross-Arch Stabilization Struts, Caitlin Libby Dds Jan 2021

Accuracy Of Implant Placement Utilizing Stereolithographic Guides Printed With And Without Cross-Arch Stabilization Struts, Caitlin Libby Dds

Graduate Theses, Dissertations, and Problem Reports (ETD)

Objectives: The purpose of this study was to assess the accuracy of implant placement using stereolithographic guides printed with and without stabilization struts by comparing the post-operative position to the planned implant position.

Methods: A pre-operative cone-beam computed tomography (CBCT) of a drillable maxillary model was obtained and data was uploaded into coDiagnostiX for preoperative planning. The implant position was planned in an edentulous space of #5 using a 3.3x10mm Bone Level Tapered (BLT) implant (Straumann). Ten surgical guides were designed utilizing a stabilization strut (Group A), while ten guides were designed without the stabilization strut (Group B). Twenty guides …


การเปรียบเทียบสมบัติเชิงกลของซิลิโคนอีลาสโตเมอร์ในงานบูรณะใบหน้าและขากรรไกร ก่อนและหลังได้รับพลังงานไมโครเวฟ, เพ็ญชนก แสนทวีสุข Jan 2021

การเปรียบเทียบสมบัติเชิงกลของซิลิโคนอีลาสโตเมอร์ในงานบูรณะใบหน้าและขากรรไกร ก่อนและหลังได้รับพลังงานไมโครเวฟ, เพ็ญชนก แสนทวีสุข

Chulalongkorn University Theses and Dissertations (Chula ETD)

วัตถุประสงค์ของงานวิจัยเพื่อศึกษาสมบัติเชิงกลของซิลิโคนอีลาสโตเมอร์ในงานประดิษฐ์ ใบหน้าและขากรรไกรชนิด VST-50 และ M511 ที ่ใส่เม็ดสีและไม่ใส่เม็ดสี ก่อนและหลังได้รับการ แช่ในน้ำที ่ทำให้ร้อนด้วยพลังงานจากเตาไมโครเวฟโดยจำลองการใช้เตาไมโครเวฟ 18 เดือน ชิ ้นงานตัวอย่าง 80 ชิ ้นต่อซิลิโคนแต่ละชนิด ทั ้งหมด 160 ชิ ้น จัดเป็น 2 กลุ ่มตามการเติมเม็ดสีคือ ชิ ้นงานที ่ไม่มีสีและชิ ้นงานมีสี โดยเป็นเม็ดสีชนิดซิลิโคน และแบ่งออกเป็นกลุ ่มควบคุมและกลุ ่มเข้า เตาไมโครเวฟ รูปร่างชิ ้นงานถูกขึ ้นรูปตามมาตรฐาน ASTM D412 และ D624 ทั ้งหมดมี 8 กลุ่ม ย่อย (n=10) ต่อซิลิโคนแต่ละชนิด การนำชิ ้นงานเข้าไมโครเวฟร่วมกับการแช่น้ำ เป็นเวลา 6 นาที ที่ 660 วัตต์ 18 ครั ้ง เป็นการจำลองการใช้งานเดือนละ 1 ครั ้ง อุณหภูมิของน้ำภายหลังการเข้า ไมโครเวฟคือ 60 องศาเซลเซียส จากการวิเคราะห์ความแปรปรวนแบบ 2 ทาง (a=.5) พบว่า ซิลิโคน VST-50 ชนิดของเม็ดสีมีผลต่อความทนต่อแรงดึงและความแข็งของชิ ้นงานซิลิโคนอย่างมี นัยสำคัญทางสถิติ (P<.001) ทั ้งกลุ ่มควบคุมและเข้าเตาไมโครเวฟ ขณะที ่การใช้เตาไมโครเวฟมีผล ต่อความทนต่อการฉีกขาดอย่างมีนัยสำคัญทางสถิติ (P<.05) ทั ้งกลุ ่มไม่มีสีและมีสี และทั ้งสอง ปัจจัยไม่มีผลต่อร้อยละการยืดตัว ขณะที ่ซิลิโคน M511 มีปฏิสัมพันธ์กันระหว่างปัจจัยการผสมเม็ด สีและการเข้าไมโครเวฟอย่างมีนัยสำคัญทางสถิติสำหรับความแข็ง (P<.05)


The Efficacy Of Universal Ceramic Polishing Kit On The Surface Roughness Of Various Ceramic Types, Ekaluck Poosanthanasarn Jan 2021

The Efficacy Of Universal Ceramic Polishing Kit On The Surface Roughness Of Various Ceramic Types, Ekaluck Poosanthanasarn

Chulalongkorn University Theses and Dissertations (Chula ETD)

The objective of this vitro study was to determine the effect of polishing performance of a universal ceramic polishing kit on the surface roughness of various ceramics. The ceramic specimen size 5 x 7 x 4 mm of lithium disilicate glass ceramic (IPS e.max CAD, Ivoclar Vivadent, Liechtenstein), translucent zirconia (VITA YZ XT, VITA Zahnfabrik, Germany) and zirconia-reinforced lithium silicate (Celtra Duo, Dentsply Sirona, United States) (n=8) were fixed with clear resin in PVC block, 14 mm in diameter. The specimens were ground with fine diamond bur for 15 seconds to simulate clinical gross contouring.The two-step polishing process started with …


The Effects Of The Oral Exercises On The Oral Function Of People With Dementia, Kwanrutai Somsak Jan 2021

The Effects Of The Oral Exercises On The Oral Function Of People With Dementia, Kwanrutai Somsak

Chulalongkorn University Theses and Dissertations (Chula ETD)

The objective of this study was to examine the effects of the home-based oral exercises on the oral function in people with mild to moderate dementia. The patients with mild to moderate dementia at King Chulalongkorn Memorial Hospital, who were randomly allocated to an experimental group (n = 11), were asked to perform 3 home-based oral exercises for 3 months while those in a control group (n = 11) did not do any oral exercises. The oral function including maximum tongue pressure (MTP), oral diadochokinesis (ODK) rates of /ta/, /ka/, /pa/, swallowing function (modified water swallowing test: MWST), and oral …


Antifungal, Physical, And Mechanical Properties Of Tissue Conditioner Incorporated With Zinc Oxide Nanoparticles, Woraporn Homsiang Jan 2021

Antifungal, Physical, And Mechanical Properties Of Tissue Conditioner Incorporated With Zinc Oxide Nanoparticles, Woraporn Homsiang

Chulalongkorn University Theses and Dissertations (Chula ETD)

This study evaluated the antifungal, physical, and mechanical properties of tissue conditioner incorporated with different amounts of zinc oxide nanoparticles (ZnOnps) at different storage times (0, 7, and 14 days). Specimens of 0, 5, 10, 15 wt% ZnOnps, or 15 wt% nystatin incorporated into tissue conditioner were fabricated. The direct contact test (n=6) was performed to evaluate the antifungal effect against C. albicans suspension. Scanning electron microscopy and energy dispersive X-ray spectroscopy (n=6) were used to observe the amount and distribution of superficial zinc element. The penetration depth (n=6) and tensile bond strength (n=8) were evaluated following ISO 13139. The …


Retentive Force Change Of Nylon Insert In Locator R-Tx Attachment After Brushing Test, Wasita Pongwattana Jan 2021

Retentive Force Change Of Nylon Insert In Locator R-Tx Attachment After Brushing Test, Wasita Pongwattana

Chulalongkorn University Theses and Dissertations (Chula ETD)

This study aimed to evaluate the effect of brushing on the percentage change of retentive force in Locator R-Tx attachment. There were 3 types of nylon inserts; blue, pink, and clear. The nylon inserts were brushed in 2 media; water and toothpaste. Each group had 6 specimens (n=6). All specimens were soaked in deionized water at 37 ºC for 7 days, after that they were placed in the simulated brushing machine. Before and after they underwent 5,000 brushing cycles, the retention test of each specimen was measured with a universal testing machine. The retentive forces were repeatedly measured 5 times …


Care And Maintenance Of Dental Restorations, Ibeth Erazo Dec 2020

Care And Maintenance Of Dental Restorations, Ibeth Erazo

Publications and Research

Contributing to the longevity of the restoration by minimizing the effects of surface corrosion, maintaining the esthetic appearance and the smooth surface characterization, and contributing to gingival health by lessening the potential for plaque retention are the principal reasons for taking care of dental restorations. However, during oral hygiene routine procedures and prevention treatments, these desired effects are not always achieved. In many cases, the restorative materials are not identified in a patient’s record leading to damage during oral hygiene performance by dental professionals. Therefore, it is important to be able to recognize the different restorative materials and employ the …


Stress Analysis Comparing Effect Of Two Different Cad-Cam Implant Superstructure Materials (In-Vitro Study), Noura Turky Saad, Essam Osman, Ahmed M. Abdelhamid, Mohamed Shokry, Ehab A. Farghaly Nov 2020

Stress Analysis Comparing Effect Of Two Different Cad-Cam Implant Superstructure Materials (In-Vitro Study), Noura Turky Saad, Essam Osman, Ahmed M. Abdelhamid, Mohamed Shokry, Ehab A. Farghaly

BAU Journal - Creative Sustainable Development

Purpose: This study was conducted to evaluate the micro-strain around dental implant using two different CAD/CAM crown fabricated materials through strain gauge analysis. Materials and Methods: Five dental implants were fixed in a 5 previously drilled solid rigid polyurethane test blocks in the edentulous area with neighboring abutments mesial and distal printed out using special 3D Dental printer, Cyanoacrylate adhesive was then used to fix the printed-out part on to the polyurethane test blocks, creating the bounded saddle replicas. Ten CAD/CAM screw retained crowns were fabricated; five Enamic crowns from vita enamic blocks, and five zirconia crowns from presintered katana …


The Effect Of Artificial Aging And Surface Treatments On Microtensile Bond Strength Of Resin Cement To Hybrid Ceramics, Engy I. Hassan Shohdy, Shereen A. Nossair, Amina M. Hamdy Sep 2020

The Effect Of Artificial Aging And Surface Treatments On Microtensile Bond Strength Of Resin Cement To Hybrid Ceramics, Engy I. Hassan Shohdy, Shereen A. Nossair, Amina M. Hamdy

Future Dental Journal

Purpose: To assess the effect of aging and various surface treatments on the microtensile bond strength of resin cement to two hybrid esthetic materials. Materials and Methods: Zirconia-reinforced lithium silicate (Celtra Duo, Dentsply Sirona, United States) and hybrid resin nanoceramic (Cerasmart TM, GC Corporation, Japan) blocks were cut into plates of 3 mm thickness. Each ceramic material was surface treated either with hydrofluoric acid etching and silane or with sandblasting and silane. A dual-cured adhesive resin cement (Panavia TM V5, Kuraray, U.S.A.) was utilized to bond the composite resin plates to the surface treated ceramic plates. The ceramic-composite resin blocks …


Nanomaterials And Nanorobotics In Dentistry: A Review, Yelda Kasimoglu, Derya Tabakcilar, Zeynep A. Guclu, Seiko Yamamoto-Nemoto, Elif B. Tuna, Bugra Ozen, Tamer Tuzuner, Gökhan Ince Aug 2020

Nanomaterials And Nanorobotics In Dentistry: A Review, Yelda Kasimoglu, Derya Tabakcilar, Zeynep A. Guclu, Seiko Yamamoto-Nemoto, Elif B. Tuna, Bugra Ozen, Tamer Tuzuner, Gökhan Ince

Journal of Dentistry Indonesia

Nanotechnology is a branch of science focusing on the manipulation of materials measured on the nanoscale (size = 1–100 nm). Recent advances in the field of nanodentistry have resulted in the development of alternative treatment plans for common dental problems, bringing about a paradigm shift in dentistry. Nanorobots, also known as “nanites” or “nanomachines,” are theoretical microscopic devices that may be used for the diagnosis and treatment of oral health problems. This paper aims to discuss the latest innovations in the field of nanodentistry.


Oral Rehabilitation Of A Patient With Congenital Erythropoietic Porphyria: A Rare Case Report, Raif Alan, Hakkı Çelebi, Fahriye Kilinc, Recep Dursun Aug 2020

Oral Rehabilitation Of A Patient With Congenital Erythropoietic Porphyria: A Rare Case Report, Raif Alan, Hakkı Çelebi, Fahriye Kilinc, Recep Dursun

Journal of Dentistry Indonesia

Congenital erythropoietic porphyria (CEP) is an extremely rare disorder involved in chronic porphyrias. One of the recommended evaluations to determine disease severity and needs of a person with CEP is dental assessment. Objective: To present a case of CEP and its oral rehabilitation. Case Report: A 32-year-old female patient was admitted to the clinic with hyperkeratinization, skin fragility, fissures, and wounds in her perioral region and hands. Intraoral gingival bleeding, mucogingival stress, and missing teeth were recorded. After medical consultation, phase I and II periodontal therapies were performed. The patient expressed satisfaction of the results of the procedures in terms …


Effect Of Nanofiller Coating And Loading On Facial Elastomer Physical Properties, Rahmi K. Aulia Aug 2020

Effect Of Nanofiller Coating And Loading On Facial Elastomer Physical Properties, Rahmi K. Aulia

Theses & Dissertations

Current materials used for facial prostheses are far from being desirable, and improved properties with “skin-like” feel are needed. This study evaluates property changes induced by sequential additions of uncoated and hydrophobic-coated nano-SiO2 to polydimethylsiloxane (PDMS) and compares them with those measured for conventional submicron SiO2-filled materials. Each filler type was sequentially added to vinyl-terminated PDMS at 0%, 0.5%, 5%, 10%, and 15% by weight. Tensile, tear, Durometer hardness, translucency and viscoelastic properties were evaluated, with hardness and translucency also evaluated following 3000 hours of outdoor weathering. Results demonstrated that 15% coated nano-SiO2-filled PDMS materials …


Cad/Cam Milling Versus Rapid Prototyping Surgical Guide Techniques In Dental Implant Placement, Fardos N. Rizk Prof., Marwa Sabet Prof., Hebatallah Mohammed, Adham Elghamry Jul 2020

Cad/Cam Milling Versus Rapid Prototyping Surgical Guide Techniques In Dental Implant Placement, Fardos N. Rizk Prof., Marwa Sabet Prof., Hebatallah Mohammed, Adham Elghamry

Dentistry

No abstract provided.


Efficacy Of Stem Cell Allograft In Maxillary Sinus Bone Regeneration: A Randomized Controlled Clinical And Blinded Histomorphometric Study, Josh Whitt, Mohanad Al-Sabbagh, Dolph R. Dawson Iii, Ehab Shehata, Moly Housley-Smith, Alejandro G. Villasante Tezanos, Ahmad Kutkut Jun 2020

Efficacy Of Stem Cell Allograft In Maxillary Sinus Bone Regeneration: A Randomized Controlled Clinical And Blinded Histomorphometric Study, Josh Whitt, Mohanad Al-Sabbagh, Dolph R. Dawson Iii, Ehab Shehata, Moly Housley-Smith, Alejandro G. Villasante Tezanos, Ahmad Kutkut

Oral Health Practice Faculty Publications

Purpose: This study aimed to evaluate the quality and quantity of newly generated bone in the maxillary sinus grafted with stem cell-based allograft material.

Methods: This study was a single site, prospective, blinded, randomized, and controlled clinical trial. Eleven subjects with 18 edentulous posterior maxillary sites requiring sinus augmentation for delayed implant placement using a lateral window approach were enrolled. At the time of sinus augmentation, test sinus was grafted with stem cell-based allograft (Osteocel Plus; NuVasive Therapeutics), while the control sinus was grafted with conventional cortico-cancellous allograft (alloOss; ACE Surgical). Cone beam computer tomography (CBCT) scan was taken before …


Replacing A Single Tooth: Single Implant Vs. Three Unit Bridge, Ibeth Erazo, Aneeza Hussain May 2020

Replacing A Single Tooth: Single Implant Vs. Three Unit Bridge, Ibeth Erazo, Aneeza Hussain

Publications and Research

There are more than two options for restoring a single tooth but our research includes a three-unit bridge and a single-tooth implant as the main options. In this paper, we discuss the advantages and disadvantages of these methods and the factors that must be considered when choosing between them for the replacement of a single tooth. Although in some cases a three-unit bridge is the most appropriate choice, implants have the advantage of allowing preservation of the integrity of sound teeth adjacent to the edentulous area. Many factors must be considered when choosing between a three-unit bridge and an implant …


Preheating-Temperature Affects Nanoleakage And Degree Of Conversion Of Dual-Cured Adhesive/Resin-Composite, Sara Adel Botros, Farid Sabry El-Askary, Zainab Diaa Soliman, Dalia Ibrahim El-Korashy May 2020

Preheating-Temperature Affects Nanoleakage And Degree Of Conversion Of Dual-Cured Adhesive/Resin-Composite, Sara Adel Botros, Farid Sabry El-Askary, Zainab Diaa Soliman, Dalia Ibrahim El-Korashy

Dentistry

No abstract provided.


Current Status Of Magnetic Resonance On Saliva For Oral And Dental Health Early Diagnosis, Anastasia Katsavochristou, Dimitrios Koumoulis Apr 2020

Current Status Of Magnetic Resonance On Saliva For Oral And Dental Health Early Diagnosis, Anastasia Katsavochristou, Dimitrios Koumoulis

Oral Health Practice Faculty Publications

Magnetic resonance spectroscopy of biomolecules has recently gained attention for clinical diagnosis. Its combination with saliva collection and analysis can promote early disease detection and monitoring, by identifying biomarkers of specific underlying pathology or disease as detected in saliva. With this novel, non-invasive technique, certain salivary biomarkers have been linked to dental and periodontal tissues pathology, as well as to specific head and neck cancer malignancies. At present, diagnostic biomarkers are still in need for further identification (e.g., diagnosis and monitoring of Sjögren’s syndrome), and nuclear magnetic resonance spectroscopy has been found to be a promising technique to compliment the …


Effect Of Different Surface Treatments On The Shear Bond Strength Between Lithium Disilicate Glass-Ceramic And Resin Cement, Siripan Simasetha Jan 2020

Effect Of Different Surface Treatments On The Shear Bond Strength Between Lithium Disilicate Glass-Ceramic And Resin Cement, Siripan Simasetha

Chulalongkorn University Theses and Dissertations (Chula ETD)

Objective: The study aimed to evaluate the shear bond strength (SBS) of lithium disilicate glass-ceramic and resin cement using different surface treatments. Methods: Lithium disilicate blocks (Vintage LD Press ®) were prepared, etched with 4.5 % hydrofluoric acid, and randomly divided into seven groups (n=10), depending on the surface treatments: 1) no surface treatment (control), 2) Silane Primer (KS), 3) Signum® Ceramic Bond I (SGI), 4) Signum® Ceramic Bond II (SGI/SGII), 5) experimental silane (EXP), 6) experimental-silane/Signum® Ceramic Bond II (EXP/SGII), and 7) Experimental/Adper™ Scotchbond Multi-purpose Adhesive (EXP/ADP). The specimens were cemented to resin composite blocks with resin cement and …


Effect Of Surface Treatment And Storage Time On Immediate Repair Bond Strength Durability Of Methacrylate- And Ormocer-Based Bulk Fill Resin Composites., Sara Adel Botros Jan 2020

Effect Of Surface Treatment And Storage Time On Immediate Repair Bond Strength Durability Of Methacrylate- And Ormocer-Based Bulk Fill Resin Composites., Sara Adel Botros

Dentistry

The aim of this study was to evaluate the effect of surface treatment and storage time on immediate repair bond durability of methacrylate- and ormocer-based bulk fill composites. In total, 265 discs were divided into 32 groups (n = 8/group) according to: (1) Material: X-tra fil and Admira Fusion X-tra; (2) Surface treatment: oxygen inhibition; matrix; Futurabond M+; Silane/Futurabond M+; Admira Bond; Silane/Admira Bond; ceramic repair system; and Silane/Cimara bond; and (3) Storage time: 24 h and 6 months. Each disc received three micro-cylinders from the same material. Specimens were subjected to micro-shear bond strength testing either at 24 h …


Radiographic Bone Changes Surrounding Implants Of Different Attachment Systems., Sara Fikry El Shafei Dr, Fardos N Rizk Prof Jan 2020

Radiographic Bone Changes Surrounding Implants Of Different Attachment Systems., Sara Fikry El Shafei Dr, Fardos N Rizk Prof

Dentistry

This study was conducted to compare the effect of GPS attachment, OT Equator attachment and Ball and Socket attachment on crestal bone around implants in implant retained mandibular overdenture cases. Materials and Methods: Following two stage surgical protocol eighteen completely edentulous patients received two implants placed bilaterally in the canine region (36 implants) to retain mandibular overdentures. Inclusion Criteria: Patients were all healthy men, non-smokers, Following Misch rules of bone classification patients with bone density ranging from 850-1250 HU (D2) and bone height and width more than 10 mm and 5 mm respectively. Four months following the surgery patients were …


Comparative Study Of Two Fifferent Telescopic Crown Materials Retaining Lower Partial Overdenture, Fardos N. Rizk Prof., Ayman Hany Amin Dr., Gehan Fikry Prof., Amr Ismail Dr. Jan 2020

Comparative Study Of Two Fifferent Telescopic Crown Materials Retaining Lower Partial Overdenture, Fardos N. Rizk Prof., Ayman Hany Amin Dr., Gehan Fikry Prof., Amr Ismail Dr.

Dentistry

Background and Objective: This study was conducted to measure the difference between Chrome Cobalt telescopic crowns and Poly ether ether ketone (PEEK) telescopic crowns retaining implant retained partial overdenture.

Materials and Methods: This is a comparitive study that included fourteen lower kennedy class I partially edendulous patients. All patients received posterior implant in the second molar area in each side. The patients were divided into 2 groups, the first group received chrome cobalt telescopic crown and the second group received poly ether ketone telescopic crowns over the implants. Partial overdenture was constructed for all the patients in the two groups. …


Three Dimensional Biometric Guide In Determining Maxillary Tooth Position And Arch Form, Tawfiq Omar Farouq Jan 2020

Three Dimensional Biometric Guide In Determining Maxillary Tooth Position And Arch Form, Tawfiq Omar Farouq

Student Works (2020-2029)

In complete denture fabrication, when pre-extraction records are lacking, determining the denture teeth positions to where the natural predecessors occupied is essential yet challenging. Although several biometric guides were suggested to position teeth for dentures, none is providing three-dimensional (3D) positions of teeth that can be used in the recently developed computer designed digital dentures. The aim of this study was to develop new biometric guides to determine the original 3D positions of the maxillary teeth and dental arch form individualised for each given dentate or edentulous maxillary cast based on selected intraoral landmarks. The objectives were to investigate the …


Global Interest For Health Professions Education: A Geographic And Temporal Analyses Through Web Search Differences From 2010-2019, Junhel Dalanon, Yoshizo Matsuka Jan 2020

Global Interest For Health Professions Education: A Geographic And Temporal Analyses Through Web Search Differences From 2010-2019, Junhel Dalanon, Yoshizo Matsuka

Internet Journal of Allied Health Sciences and Practice

Purpose: The purpose of this study was to analyze the spatio-temporal differences in web search trends for dental degrees (DD), medical degrees (MD), and nursing degrees (ND) across 197 countries from 2010 to 2019. Method: A search string was used to initiate a search query using Google Trends. The parameters used were DD, MD, and ND as search terms; worldwide as Location; 2010 to 2019 as time range; health education & medical training as category; and web search as database. Data were downloaded and analyzed. Results: Via one-way ANOVA and post hoc Dunnett test, the searches for DD were found …


The Visual And Spectrophotometric Effect Of External Bleaching On Omnichroma Resin Composite And Natural Teeth, Michael Brian Evans Jan 2020

The Visual And Spectrophotometric Effect Of External Bleaching On Omnichroma Resin Composite And Natural Teeth, Michael Brian Evans

Graduate Theses, Dissertations, and Problem Reports (ETD)

Objective: To determine the visual and spectrophotometric effect external tooth bleaching has on natural tooth structure and OMNiCHROMA composite at various number of treatments. Variables were compared to determine if there is a detectable difference between the composite and the tooth before and after bleaching.

Methods: Preparation and restoration of 25 previously extracted teeth was completed. OMNiCHROMA composite was used. Each tooth was measured visually with a VITA shade guide and a colorimeter. Measurements were recorded before bleaching, after 5 and 10 treatments. Statistical analysis was completed and ΔE values between the composite and tooth were compared between the 3 …


Comparative Study Of Tensile Bond Strength Between Resin Cements And Hybrid Materials, Chakriya Donpinprai Jan 2020

Comparative Study Of Tensile Bond Strength Between Resin Cements And Hybrid Materials, Chakriya Donpinprai

Chulalongkorn University Theses and Dissertations (Chula ETD)

Purpose: To compare tensile bond strength among the hybrid materials (VITA ENAMIC®, SHOFU Block HC, Katana AVENCIA and Experimental material) using two primers (Universal ceramic primer and RelyX ceramic primer) and two resin cements (Super-Bond C&B and RelyXTM U200). Methods: Twenty blocks of 4×4×1 mm3 were prepared from each material type. In VITA ENAMIC® group, specimens were conditioned with 5% Hydrofluoric acid and primer. In SHOFU Block HC and Katana AVENCIA groups, specimens were treated with 50µm alumina and primer. In experimental material, specimens were etched with 65% Phosphoric acid. Ten specimens were randomly assigned to each group for different …


Gene Expression And Immunohistochemistry Analysis Of Xenograft And Allograft In Maxillary Sinus Floor Augmentation, Isaya Kungvarnchaikul Jan 2020

Gene Expression And Immunohistochemistry Analysis Of Xenograft And Allograft In Maxillary Sinus Floor Augmentation, Isaya Kungvarnchaikul

Chulalongkorn University Theses and Dissertations (Chula ETD)

Quality of bone is an important factor contributing to the success of dental implants. The bone height in maxillary posterior area sometimes is not enough and might pose risks for placing dental implants. Maxillary sinus augmentation with bone substitutes is used for filling and correcting bony defects. This study aims to determine the differences in gene expressions of TNF-alpha, RUNX2, COL1A1, ALP between xenograft (Bio-Oss®) and allograft (SureOss®). Patients who needed two-stage maxillary sinus floor augmentation were included (n=13). Patient who had dental implant at posterior maxilla without bone substitutes was also used in immunohistochemistry analysis (IHC) (n=1). Bone samples …


Effect Of Deep Margin Elevation With Resin Composite And Resin-Modified Glass Ionomer On Marginal Sealing Of Cad/Cam Ceramic Inlays: An In Vitro Study, Jaraswan Vichitgomen Jan 2020

Effect Of Deep Margin Elevation With Resin Composite And Resin-Modified Glass Ionomer On Marginal Sealing Of Cad/Cam Ceramic Inlays: An In Vitro Study, Jaraswan Vichitgomen

Chulalongkorn University Theses and Dissertations (Chula ETD)

Purpose. To evaluate the marginal sealing ability of different restorative materials used in deep margin elevation (DME) on zirconia-reinforced lithium silicate CAD/CAM ceramic restoration. Methods. A total of 30 Class II cavities were prepared in freshly extracted human molars with the proximal gingival margin located 1 mm below the cemento-enamel junction (CEJ). All specimens were randomly assigned to one of three groups (n=10): control group, resin composite group (FiltekTM Z350 XT), and resin-modified glass ionomer group (VitremerTM Tricure). In group 1, control group, no DME was performed. The inlay margin of the control group was placed directly onto dentin. In …


The Effect Of Laser Power On Mechanical And Physical Properties Of Ti-6al-4v Eli Fabricated By Selective Laser Melting, Pajaree Termrungruanglert Jan 2020

The Effect Of Laser Power On Mechanical And Physical Properties Of Ti-6al-4v Eli Fabricated By Selective Laser Melting, Pajaree Termrungruanglert

Chulalongkorn University Theses and Dissertations (Chula ETD)

This study aimed to examine the differences in mechanical and physical properties of Ti-6Al-4V extra low interstitial (ELI) fabricated by selective laser melting (SLM) between different laser power. The Ti-6Al-4V ELI alloy samples were printed in dumbbell shape by SLM machine (Trumpf/TruPrint 1000, Germany) with 3 laser powers (75, 100 and 125 W), 8 samples for each group. And the other parameters (spot size 30 µm, scanning speed 600 mm/s, layer thickness 30 µm) were kept constantly. All samples were performed under tensile test with universal testing machine. Moreover, The microhardness test was performed. All data were statistically analyzed with …