Peculiarities Of Phosphatidylserine Externalization By Nano- And Microsecond Electric Pulses, Mantas Silkunas, Alayna Enos, Iurii Semenov, Giedre Silkuniene, Eleni Zivla, Olga N. Pakhomova, Andrei G. Pakhomov Jan 2026

Peculiarities Of Phosphatidylserine Externalization By Nano- And Microsecond Electric Pulses, Mantas Silkunas, Alayna Enos, Iurii Semenov, Giedre Silkuniene, Eleni Zivla, Olga N. Pakhomova, Andrei G. Pakhomov

Bioelectrics Publications

Phosphatidylserine (PS) externalization is a hallmark of apoptosis but can also be triggered within seconds by pulsed electric fields (PEFs). Whether PS reaches the outer leaflet by lateral migration through electropores or indirectly through Ca²+-dependent signaling and scramblase activation remains debated. We used total internal reflection fluorescence (TIRF) microscopy with Annexin V-Alexa Fluor 568 and/or bovine lactadherin-FITC to resolve PS externalization in HEK293 cells placed on an indium tin oxide (ITO) transparent electrode. PEF exposures produced discrete PS-positive puncta ("freckles") within ~ 10 s after a 20-µs pulse (1.2-2.5 kV/cm) or with a ~ 1-min delay after a …


Nanosecond Pulsed Electric Fields For Extracellular Vesicle Engineering: From Electro-Exocytosis To Cargo Modulation, Art Neal, Teresa Graham, Mohamadmahdi Samandari, Arash Ghorbannia, Anca Dobrian, Stephen J. Beebe, Ruben M. L. Colunga-Biancatelli Jan 2026

Nanosecond Pulsed Electric Fields For Extracellular Vesicle Engineering: From Electro-Exocytosis To Cargo Modulation, Art Neal, Teresa Graham, Mohamadmahdi Samandari, Arash Ghorbannia, Anca Dobrian, Stephen J. Beebe, Ruben M. L. Colunga-Biancatelli

Bioelectrics Publications

Extracellular vesicles (EVs), including small extracellular vesicles (sEVs) and medium/large extracellular vesicles (MVs), have emerged as promising therapeutic vectors and diagnostic biomarkers across various branches of biomedicine. However, the clinical translation of EV-based technologies remains constrained by persistent challenges in manufacturing: insufficient yield from primary cell sources, limited control over cargo composition, and the absence of scalable, standardized production platforms. Nanosecond pulsed electric fields (nsPEF) represent an emerging biophysical approach that can address several of these limitations. Unlike conventional electroporation, which targets the plasma membrane using microsecond-to-millisecond pulses, nsPEF delivers ultrashort (1–300 ns), high-amplitude (10–300 kV/cm) pulses that penetrate intracellularly …


Potentiation Of Gelonin Cytotoxicity By Pulsed Electric Fields, Olga N. Pakhomova, Eleni Zivla, Giedre Silkuniene, Mantas Silkunas, Andrei G. Pakhomov Jan 2025

Potentiation Of Gelonin Cytotoxicity By Pulsed Electric Fields, Olga N. Pakhomova, Eleni Zivla, Giedre Silkuniene, Mantas Silkunas, Andrei G. Pakhomov

Bioelectrics Publications

Gelonin is a ribosome-inactivating protein with extreme intracellular toxicity but poor permeation into cells. Targeted disruption of cell membranes to facilitate gelonin entry is explored for cancer and tissue ablation. We demonstrate a hundreds- to thousands-fold enhancement of gelonin cytotoxicity by pulsed electric fields in the T24, U-87, and CT26 cell lines. The effective gelonin concentration to kill 50% of cells (EC₅₀) after electroporation ranged from <1 nM to about 100 nM. For intact cells, the EC₅₀ was unattainable even at the highest gelonin concentration of 1000 nM, which reduced cell survival by only 5–15%. For isoeffective electroporation treatments using 300 ns, 9 µs, and 100 µs pulses, longer pulses were more efficient at lowering gelonin EC₅₀. Increasing the electric field strength of 8, 100 µs pulses from 0.65 to 1.25 kV/cm reduced gelonin EC₅₀ from 128 nM to 0.72 nM. Conversely, the presence of 100 nM gelonin enabled a more than 20-fold reduction in the number of pulses required for equivalent cell killing. Pulsed electric field-mediated delivery of gelonin shows promise for hyperplasia ablation at concentrations sufficiently low to minimize or avoid systemic toxicity.


Nanosecond Pulsed Electric Fields Increase Antibiotic Susceptibility In Methicillin-Resistant Staphylococcus Aureus, Alexandra E. Chittams-Miles, Areej Malik, Erin B. Purcell, Claudia Muratori Jan 2024

Nanosecond Pulsed Electric Fields Increase Antibiotic Susceptibility In Methicillin-Resistant Staphylococcus Aureus, Alexandra E. Chittams-Miles, Areej Malik, Erin B. Purcell, Claudia Muratori

Bioelectrics Publications

Staphylococcus aureus is the leading cause of skin and soft-tissue infections (SSTIs). SSTIs caused by bacteria resistant to antimicrobials, such as methicillin-resistant S. aureus (MRSA), are increasing in incidence and have led to higher rates of hospitalization. In this study, we measured MRSA inactivation by nanosecond pulsed electric fields (nsPEF), a promising new cell ablation technology. Our results show that treatment with 120 pulses of 600 ns duration (28 kV/cm, 1 Hz), caused modest inactivation, indicating cellular damage. We anticipated that the perturbation created by nsPEF could increase antibiotic efficacy if nsPEF were applied as a co-treatment. To test this …


Dihydroethidium-Derived Fluorescence In Electrically Stressed Cells Indicates Intracellular Microenvironment Modifications Independent Of Ros, Esin B. Sözer, Iurii Semenov, P. Thomas Vernier Jan 2024

Dihydroethidium-Derived Fluorescence In Electrically Stressed Cells Indicates Intracellular Microenvironment Modifications Independent Of Ros, Esin B. Sözer, Iurii Semenov, P. Thomas Vernier

Bioelectrics Publications

Intracellular reactive oxygen species (ROS) generation is widely suggested as a trigger for biological consequences of electric field exposures, such as those in electroporation applications. ROS are linked with membrane barrier function degradation, genetic damage, and complex events like immunological cell death. Dihydroethidium (DHE) is commonly used to monitor ROS in cells. DHE is linked to intracellular ROS by a primary oxidation product, Ethidium (Eth+), that shows increased fluorescence upon binding to polynucleotides. We observed changes in DHE-derived fluorescence in Chinese hamster ovary (CHO) cells post 300-ns electric pulse exposures, comparing them to tert-butyl-hydroperoxide (t-BHP) induced oxidative stress. …


Dynamics Of Cell Membrane Lesions And Adaptive Conductance Under The Electrical Stress, Mantas Silkunas, Olga N. Pakhomova, Giedre Silkuniene, Andrei G. Pakhomov Jan 2024

Dynamics Of Cell Membrane Lesions And Adaptive Conductance Under The Electrical Stress, Mantas Silkunas, Olga N. Pakhomova, Giedre Silkuniene, Andrei G. Pakhomov

Bioelectrics Publications

Exceeding physiological limits of the cell membrane potential compromises structural integrity, enabling the passage of normally impermeant solutes and disrupting cell function. Electropermeabilization has been studied extensively at the cellular scale, but not at the individual membrane lesion level. We employed fast total internal reflection fluorescence (TIRF) imaging of Ca(2+) entry transients to discern individual lesions in a hyperpolarized cell membrane and characterize their focality, thresholds, electrical conductance, and the lifecycle. A diffuse and momentary membrane permeabilization without a distinct pore formation was observed already at a -100 mV threshold. Polarizing down to -200 mV created focal pores with a …


Control Of The Electroporation Efficiency Of Nanosecond Pulses By Swinging The Electric Field Vector Direction, Vitalii Kim, Iurii Semenov, Allen S. Kiester, Mark A. Keppler, Bennett L. Ibey, Joel N. Bixler, Ruben M. L. Colunga Biancatelli, Andrei G. Pakhomov Jun 2023

Control Of The Electroporation Efficiency Of Nanosecond Pulses By Swinging The Electric Field Vector Direction, Vitalii Kim, Iurii Semenov, Allen S. Kiester, Mark A. Keppler, Bennett L. Ibey, Joel N. Bixler, Ruben M. L. Colunga Biancatelli, Andrei G. Pakhomov

Bioelectrics Publications

Reversing the pulse polarity, i.e., changing the electric field direction by 180°, inhibits electroporation and electrostimulation by nanosecond electric pulses (nsEPs). This feature, known as “bipolar cancellation,” enables selective remote targeting with nsEPs and reduces the neuromuscular side effects of ablation therapies. We analyzed the biophysical mechanisms and measured how cancellation weakens and is replaced by facilitation when nsEPs are applied from different directions at angles from 0 to 180°. Monolayers of endothelial cells were electroporated by a train of five pulses (600 ns) or five paired pulses (600 + 600 ns) applied at 1 Hz or 833 kHz. Reversing …


Pulsed Electric Field Ablation Of Esophageal Malignancies And Mitigating Damage To Smooth Muscle: An In Vitro Study, Emily Gudvangen, Uma Mangalanathan, Iurii Semenov, Allen S. Kiester, Mark A. Keppler, Bennett L. Ibey, Joel N. Bixler, Andrei G. Pakhomov Jan 2023

Pulsed Electric Field Ablation Of Esophageal Malignancies And Mitigating Damage To Smooth Muscle: An In Vitro Study, Emily Gudvangen, Uma Mangalanathan, Iurii Semenov, Allen S. Kiester, Mark A. Keppler, Bennett L. Ibey, Joel N. Bixler, Andrei G. Pakhomov

Bioelectrics Publications

Cancer ablation therapies aim to be efficient while minimizing damage to healthy tissues. Nanosecond pulsed electric field (nsPEF) is a promising ablation modality because of its selectivity against certain cell types and reduced neuromuscular effects. We compared cell killing efficiency by PEF (100 pulses, 200 ns–10 µs duration, 10 Hz) in a panel of human esophageal cells (normal and pre-malignant epithelial and smooth muscle). Normal epithelial cells were less sensitive than the pre-malignant ones to unipolar PEF (15–20% higher LD50, p < 0.05). Smooth muscle cells (SMC) oriented randomly in the electric field were more sensitive, with 30–40% lower LD50 (p < 0.01). Trains of ten, 300-ns pulses at 10 kV/cm caused twofold weaker electroporative uptake of YO-PRO-1 dye in normal epithelial cells than in either pre-malignant cells or in SMC oriented perpendicularly to the field. Aligning SMC with the field reduced the dye uptake fourfold, along with a twofold reduction in Ca2+ transients. A 300-ns pulse induced a twofold smaller transmembrane potential in cells aligned with the field, making them …


Identification Of Proteins Involved In Cell Membrane Permeabilization By Nanosecond Electric Pulses (Nsep), Giedre Silkuniene, Uma Mangalanathan, Alessandra Rossi, Peter A. Mollica, Andrei G. Pakhomov, Olga N. Pakhomova Jan 2023

Identification Of Proteins Involved In Cell Membrane Permeabilization By Nanosecond Electric Pulses (Nsep), Giedre Silkuniene, Uma Mangalanathan, Alessandra Rossi, Peter A. Mollica, Andrei G. Pakhomov, Olga N. Pakhomova

Bioelectrics Publications

The study was aimed at identifying endogenous proteins which assist or impede the permeabilized state in the cell membrane disrupted by nsEP (20 or 40 pulses, 300 ns width, 7 kV/cm). We employed a LentiArray CRISPR library to generate knockouts (KOs) of 316 genes encoding for membrane proteins in U937 human monocytes stably expressing Cas9 nuclease. The extent of membrane permeabilization by nsEP was measured by the uptake of Yo-Pro-1 (YP) dye and compared to sham-exposed KOs and control cells transduced with a non-targeting (scrambled) gRNA. Only two KOs, for SCNN1A and CLCA1 genes, showed a statistically significant reduction in …


Atmospheric Air Plasma Streamers Deliver Nanosecond Pulses For Focused Electroporation, Shu Xiao, Carol Zhou, Eric Appia, Shirshak Dhali Jan 2022

Atmospheric Air Plasma Streamers Deliver Nanosecond Pulses For Focused Electroporation, Shu Xiao, Carol Zhou, Eric Appia, Shirshak Dhali

Bioelectrics Publications

Background: For electrotherapies that involve electrodes and high-intensity electric fields, such as in tissue ablation, we report a method of pulse delivery that can focus the electric field away from the electrodes, as demonstrated in vitro.

Materials and Methods: To electroporate cells in a monolayer seeded in a 35 mm culture dish, two atmospheric-pressure plasma channels generated by two thin, copper foil electrodes above the surface of the solution provided the current and established the electric field.

Results: Depending on the pulse duration, the plasma channels were observed as corona (100 ns), streamer (300 ns), and mixture of streamer …


Electroporation And Cell Killing By Milli- To Nanosecond Pulses And Avoiding Neuromuscular Stimulation In Cancer Ablation, Emily Gudvangen, Vitalii Kim, Vitalij Novickij, Federico Battista, Andrei G. Pakhomov Jan 2022

Electroporation And Cell Killing By Milli- To Nanosecond Pulses And Avoiding Neuromuscular Stimulation In Cancer Ablation, Emily Gudvangen, Vitalii Kim, Vitalij Novickij, Federico Battista, Andrei G. Pakhomov

Bioelectrics Publications

Ablation therapies aim at eradication of tumors with minimal impact on surrounding healthy tissues. Conventional pulsed electric field (PEF) treatments cause pain and muscle contractions far beyond the ablation area. The ongoing quest is to identify PEF parameters efficient at ablation but not at stimulation. We measured electroporation and cell killing thresholds for 150 ns–1 ms PEF, uni- and bipolar, delivered in 10- to 300-pulse trains at up to 1 MHz rates. Monolayers of murine colon carcinoma cells exposed to PEF were stained with YO-PRO-1 dye to detect electroporation. In 2–4 h, dead cells were labeled with propidium. Electroporation and …


Peculiarities Of Neurostimulation By Intense Nanosecond Pulsed Electric Fields: How To Avoid Firing In Peripheral Nerve Fibers, Vitalii Kim, Emily Gudvangen, Oleg Kondratiev, Luis Redondo, Shu Xiao, Andrei G. Pakhomov Jan 2021

Peculiarities Of Neurostimulation By Intense Nanosecond Pulsed Electric Fields: How To Avoid Firing In Peripheral Nerve Fibers, Vitalii Kim, Emily Gudvangen, Oleg Kondratiev, Luis Redondo, Shu Xiao, Andrei G. Pakhomov

Bioelectrics Publications

Intense pulsed electric fields (PEF) are a novel modality for the efficient and targeted ablation of tumors by electroporation. The major adverse side effects of PEF therapies are strong involuntary muscle contractions and pain. Nanosecond-range PEF (nsPEF) are less efficient at neurostimulation and can be employed to minimize such side effects. We quantified the impact of the electrode configuration, PEF strength (up to 20 kV/cm), repetition rate (up to 3 MHz), bi- and triphasic pulse shapes, and pulse duration (down to 10 ns) on eliciting compound action potentials (CAPs) in nerve fibers. The excitation thresholds for single unipolar but not …


Analysis Of Ca²⁺ Mobilization Of Nanosecond Pulses In Cells, Iurii Semenov Jan 2016

Analysis Of Ca²⁺ Mobilization Of Nanosecond Pulses In Cells, Iurii Semenov

Bioelectrics Publications

Exposure to nanosecond electric pulses (nsEPs) evokes transient rise of cytosolic free Ca²⁺ concentration ([Ca²⁺]i) in the cells. We quantified the external Ca²⁺ uptake, intracellular Ca²⁺ release and uncover interplay of these processes for CHO-K1 cells upon exposure to single 60 ns pulse in the range of amplitudes from 0 to 30 kV/cm. NsEPs are distinguished by the ability to electroporate intracellular membranes. We studied how duration of nsEPs is related to efficiency of intracellular membranes electroporation comparing ability of single 300-, 60- and 10 ns pulses to recruit Ca²⁺ from endoplasmic reticulum (ER) in respect to the uptake of …


Subnanosecond Exposure Systems For Biological Studies, Jongbong Nah Oct 2012

Subnanosecond Exposure Systems For Biological Studies, Jongbong Nah

Electrical & Computer Engineering Theses & Dissertations

The research of bioelectrics has expanded to subnanosecond pulse region and entered a new domain of biophysics of cell interaction with ultra-short and intense electric fields. As subnanosecond pulses may be delivered by antennas to the human body and is very attractive to the medical community, the study of subnanosecond pulse effects calls for exposure systems for both cells and tissues. Two systems were designed in the scope of this thesis, used for cells and tissues respectively. The exposure system designed for cell exposure is a cuvette consisting of two parallel aluminum gaps. This cuvette is placed in a coaxial …