Open Access. Powered by Scholars. Published by Universities.®

Equipment and Supplies

Institution
Keyword
Publication Year
Publication
Publication Type

Articles 31 - 42 of 42

Full-Text Articles in Surgical Procedures, Operative

Intraabdominal Fire During Emergency Laparotomy, Heather Christopherson Md, Alan Kroll Md Oct 2019

Intraabdominal Fire During Emergency Laparotomy, Heather Christopherson Md, Alan Kroll Md

Anesthesiology

72 yo obese male presented to ED for 2 day history abdominal pain: sharp, radiating bilateral upper quadrants, n/v/constipation. Patient took entire bottle magnesium citrate, pain became unbearable. On arrival SaO2 88% RA, other vitals stable, Lactic Acid 1.85 mg/dl, CT abdomen massive free air. Taken to OR, intubated, general anesthesia, peritoneal cavity entered with cautery device. Upon entering peritoneum abdomen, flames erupted from the cavity. Flames spontaneously extinguished. No thermal injury sustained by patient. Surgeon’s eyebrows where singed, no other injuries sustained by OR staff. Patient remained hemodynamically stable, surgery proceeded without incident.


Utilizing Simulation To Implement Cognitive Aids In The Operating Room, Kaitlyn Brown May 2019

Utilizing Simulation To Implement Cognitive Aids In The Operating Room, Kaitlyn Brown

Doctor of Nursing Practice Projects

Background: Operating room crises require prompt, efficient action to avoid detrimental outcomes. Research shows that crisis checklists or other cognitive aids assist anesthesia providers in taking prompt action while improving efficiency by decreasing treatment steps missed during critical events.

Objectives: The purpose of this project was to evaluate the effectiveness of incorporating cardiac arrest and malignant hyperthermia crisis checklists into the operating room using high-fidelity simulation-based education.

Methods: Researchers implemented the Stanford Emergency Manual Cognitive Aids for cardiac arrest and malignant hyperthermia to anesthesia staff at a community hospital in southern Illinois with 18 participants. Implementation consisted of an education …


Left Atrial Model, Borna Sobati, Sarah Porello, Tess Pate May 2019

Left Atrial Model, Borna Sobati, Sarah Porello, Tess Pate

Biomedical Engineering

The objective is to produce an electrophysiological model of an adult human left atrium. This model will be used to test mapping probe catheters used for locating cardiac arrhythmias against current technology used in practice. Dr. Chris Porterfield requested this model and other physicians or probe catheter manufacturers may also use this product in the future. Dr. Porterfield also discussed the possibility of future senior project groups using the model as a bench test for designing new catheter tips. The model will precisely simulate electrical behaviors of the heart in normal as well as arrhythmic conditions. Ideally, the model will …


Effects Of Revision Surgery On Grade Of Adverse Local Tissue Reaction Following Recall Of A Modular Hip Implant, Joseph F. Davies, Danielle M. Greer, Susan Truchan Nov 2017

Effects Of Revision Surgery On Grade Of Adverse Local Tissue Reaction Following Recall Of A Modular Hip Implant, Joseph F. Davies, Danielle M. Greer, Susan Truchan

Journal of Patient-Centered Research and Reviews

Background: The Stryker Rejuvenate modular hip implant device allows for greater versatility in matching a patient’s anatomy than conventional implants. Device recalls and in vivo metal hypersensitivity after total hip arthroplasty (THA) are common. However, recall of the Rejuvenate implant represents one of the largest recall volumes to date, highlighting our uncertainty regarding causes of device metal fretting/corrosion and adverse local tissue reaction (ALTR). While devices with metal-on-metal bearings historically were culprits for release of metal debris, more recently developed modular-neck devices add opportunity for adjacent metal components to rub together. With the Rejuvenate device, corrosion or fretting likely occurs …


A Novel Hybrid Imaging System To Aid In Surgical Decision Making, Lawrence Yip, Madeleine Van De Kleut, Ivan Kosik, Astrid Chamson-Reig, Jeffrey Jl Carson Mar 2017

A Novel Hybrid Imaging System To Aid In Surgical Decision Making, Lawrence Yip, Madeleine Van De Kleut, Ivan Kosik, Astrid Chamson-Reig, Jeffrey Jl Carson

Western Research Forum

Background:

Breast cancer accounts for 25% of all cancer cases among women. In breast-conserving surgery, a common treatment, the tumour is excised with a healthy tissue margin. However, detection of the margin can be difficult. Current techniques to guide excision are often insufficient, and re-excision can occur up to 25% of the time.

Methods:

Photoacoustic imaging is a hybrid imaging modality that combines the advantages of optical imaging and ultrasound while using safe non-ionizing light. This project involves the development of a novel imaging system with a new scanner design to overcome common limitations and provide images to aid in …


Changing Diagnostic Methods And Increased Detection Of Verotoxigenic Escherichia Coli, Ireland, Thomas Rice, Noreen Quinn, Roy D. Sleator, Brigid Lucey Sep 2016

Changing Diagnostic Methods And Increased Detection Of Verotoxigenic Escherichia Coli, Ireland, Thomas Rice, Noreen Quinn, Roy D. Sleator, Brigid Lucey

Department of Biological Sciences Publications

The recent paradigm shift in infectious disease diagnosis from culture-based to molecular-based approaches is exemplified in the findings of a national study assessing the detection of verotoxigenic Escherichia coli infections in Ireland. The methodologic changes have been accompanied by a dramatic increase in detections of non-O157 verotoxigenic E. coli serotypes.


Towards Highly-Integrated Stereovideoscopy For In Vivo Surgical Robots, Jay Carlson Aug 2014

Towards Highly-Integrated Stereovideoscopy For In Vivo Surgical Robots, Jay Carlson

Department of Electrical and Computer Engineering: Dissertations, Theses, and Student Research

When compared to traditional surgery, laparoscopic procedures result in better patient outcomes: shorter recovery, reduced post-operative pain, and less trauma to incisioned tissue. Unfortunately, laparoscopic procedures require specialized training for surgeons, as these minimally-invasive procedures provide an operating environment that has limited dexterity and limited vision. Advanced surgical robotics platforms can make minimally-invasive techniques safer and easier for the surgeon to complete successfully. The most common type of surgical robotics platforms -- the laparoscopic robots -- accomplish this with multi-degree-of-freedom manipulators that are capable of a diversified set of movements when compared to traditional laparoscopic instruments. Also, these laparoscopic robots …


Measurement And Description Of Dynamics Required For In Vivo Surgical Robotics Via Kinematic Methods, Jacob G. Greenburg Aug 2013

Measurement And Description Of Dynamics Required For In Vivo Surgical Robotics Via Kinematic Methods, Jacob G. Greenburg

Department of Mechanical and Materials Engineering: Dissertations, Theses, and Student Research

With the goal of improved recovery times and reduced trauma to the patient there has been a substantial shift in the medical community’s demand for minimally invasive surgical (MIS) techniques. With the standardization of MIS becoming more commonplace in the medical field there are still many improvements that are desired. Traditional, manual methods of these surgeries require multiple incisions on the abdomen for the tools and instruments to be inserted. The more recent demand has been to localize the incisions into what is being referred to as a Laparoendoscopic Single-Site (LESS) surgery. Furthermore, the manual instruments that are commonly used …


Adaptive Support Ventilation Reduces The Number Of Ventilator Changes From Initiation To Liberation, Bryn S. Pencil Bs, Rrt-Accs, Kenneth Miller Med, Rrt-Nps, Courtney Edwards Md Jan 2013

Adaptive Support Ventilation Reduces The Number Of Ventilator Changes From Initiation To Liberation, Bryn S. Pencil Bs, Rrt-Accs, Kenneth Miller Med, Rrt-Nps, Courtney Edwards Md

Patient Care Services / Nursing

No abstract provided.


Effects Of Arterial Strain And Stress In The Prediction Of Restenosis Risk: Computer Modeling Of Stent Trials, Shijia Zhao, Linxia Gu, Stacey R. Froemming Jan 2012

Effects Of Arterial Strain And Stress In The Prediction Of Restenosis Risk: Computer Modeling Of Stent Trials, Shijia Zhao, Linxia Gu, Stacey R. Froemming

Department of Mechanical and Materials Engineering: Faculty Publications

Purpose — In-stenting restenosis is one of the major complications after stenting. Clinical trials of various stent designs have reported different restenosis rates. However, quantitative correlation between stent features and restenosis statistics is scant. In this work, it is hypothesized that stress concentrations on arterial wall caused artery injury, which initiates restenosis. The goal is to assess the correlation between stent-induced arterial stress and strain and the documented restenosis rates.

Methods — Six commercially available stents, including balloon-expandable stents and self-expanding stents, were virtually implanted into the arteries through finite element method. The resulted peak Von Mises stress, principal stress, …


Biomechanical Comparison Of Lumbar Disc Replacements, Peter Wong May 2009

Biomechanical Comparison Of Lumbar Disc Replacements, Peter Wong

Theses and Dissertations (ETD)

Surgical options for lumbar spinal disorders are rapidly expanding. One seemingly promising area is the lumbar disc replacement. Design specifications vary among the manufacturers based upon differing perceptions of ideal motion. Comparison studies are important in quantifying different features for future improvements but are currently lacking. The objective of this study was to compare the biomechanical properties of three currently available treatments: disc replacement with ProDisc-L, disc replacement with Maverick, and a pedicle screw fixation. It was hypothesized that structural designs differences of ProDisc-L and Maverick could be distinguished in both motion and loading patterns. It was also hypothesized that …


Impact Of Suture Choice On Stricture Formation Following Repair Of Esophageal Atresia, Shawn D. St Peter, Patricia A. Valusek, Charles L. Snyder, G W. Holcomb Iii, Daniel J. Ostlie Apr 2007

Impact Of Suture Choice On Stricture Formation Following Repair Of Esophageal Atresia, Shawn D. St Peter, Patricia A. Valusek, Charles L. Snyder, G W. Holcomb Iii, Daniel J. Ostlie

Manuscripts, Articles, Book Chapters and Other Papers

Background/ Purpose: The most common complication following repair of esophageal atresia is anastomotic stricture. Despite strong opinions of pediatric surgeons regarding the type of suture used for the anastomosis, these opinions remain unsubstantiated by any data present in the literature. Therefore, we investigated the rate and severity of stricture formation relative to the suture size and material.
Materials & Methods: A retrospective analysis of our most recent 20-year experience with repair of esophageal atresia and tracheoesophageal fistula (EA/TEF) was performed. Stricture was defined as the need for dilation. Outcomes were analyzed based on absorbability, texture, and type of …