Open Access. Powered by Scholars. Published by Universities.®

Études primaires

Discipline
Keyword
Publication Year

Articles 1 - 13 of 13

Full-Text Articles in Investigative Techniques

Development Of A New Spe Uplc–Ms/Ms Method For Extraction And Quantitation Of Toluene Diamine On Gloves Following Toluene Diisocyanate Exposure, Asma Daoud, Pierre-Luc Cloutier, Sébastien Gagné, Livain Breau, Jacques Lesage Jan 2022

Development Of A New Spe Uplc–Ms/Ms Method For Extraction And Quantitation Of Toluene Diamine On Gloves Following Toluene Diisocyanate Exposure, Asma Daoud, Pierre-Luc Cloutier, Sébastien Gagné, Livain Breau, Jacques Lesage

Études primaires

Rationale

Toluene diisocyanate (TDI) is a highly reactive isocyanate commonly used as a mixture of 2,4- and 2,6- isomers in the production of flexible foams. Exposure to TDI occurs primarily through vapour inhalation in workplaces where TDI is produced or used, but dermal exposure is also possible during some tasks. To ensure workplace safety, accurate monitoring of TDI and toluene diamine (TDA) levels is required. Methods of quantifying field effectiveness of gloves in preventing dermal exposure have not been established. Therefore, there is a need to develop a new practical method for assessing glove effectiveness for TDI/TDA.

Method

A new …


Development And Characterization Of An Adaptable Aerosolized Methylene Diphenyl Diisocyanate Generation System, Simon Aubin, Loïc Wingert, Sébastien Gagné, Livain Breau, Jacques Lesage Jan 2021

Development And Characterization Of An Adaptable Aerosolized Methylene Diphenyl Diisocyanate Generation System, Simon Aubin, Loïc Wingert, Sébastien Gagné, Livain Breau, Jacques Lesage

Études primaires

Reactive semivolatile contaminants, such as isocyanates, can be particularly difficult to assess in occupational environments. While standard methods exist for isocyanates, there are still significant differences between the results they provide for various occupational environments or processes. This study presents the validation of a laboratory system for the generation of controlled atmospheres of isocyanates. A system consisting of different modules generated airborne methylene diphenyl diisocyanate (MDI) by nebulizing a solution into mixing and exposure chambers with control of flow rate, temperature, and relative humidity. Sampling was performed through an eight-port flow splitter that allowed only very slight within-test variability. MDI …


Development Of A Method For Quantification Of Toluene Diisocyanate And Methylenediphenyl Diisocyanate Migration From Polyurethane Foam Sample Surface To Artificial Sweat By Hplc-Uv-Ms, Aleksandra Donchenko, Simon Aubin, Sébastien Gagné, Mark Spence, Livain Breau, Jacques Lesage Jan 2020

Development Of A Method For Quantification Of Toluene Diisocyanate And Methylenediphenyl Diisocyanate Migration From Polyurethane Foam Sample Surface To Artificial Sweat By Hplc-Uv-Ms, Aleksandra Donchenko, Simon Aubin, Sébastien Gagné, Mark Spence, Livain Breau, Jacques Lesage

Études primaires

The US Environmental protection agency (EPA) has published guidance that includes test procedures for evaluating indoor exposure to chemicals from products. One of the test procedures represents the migration test for evaluating potential dermal exposure from home furniture. Such an evaluation involves the chemical measurement of the sweat which is currently unavailable in the literature. The objective of this project was to develop and validate an analytical method for quantification of migration of 4,4′-methylenediphenyl diisocyanate (MDI), 2,6-toluene diisocyanate (2,6-TDI) and 2,4-toluene diisocyanate (2,4-TDI) from a polyurethane (PU) flexible foam to artificial sweat that meets the recommendations of the EPA test …


On Site Comparison Of The Osha 42, Asset Ez4-Nco, Iso-Chek, Dan And Cip10 Methods For Measuring Toluene Diisocyanate (Tdi) At A Polyurethane Foam Factory, Simon Aubin, El Mekki Hamdi, Audrey Joly, Philippe Sarazin, Jacques Lesage, Livain Breau, Mark Spence, Sébastien Gagné Jan 2020

On Site Comparison Of The Osha 42, Asset Ez4-Nco, Iso-Chek, Dan And Cip10 Methods For Measuring Toluene Diisocyanate (Tdi) At A Polyurethane Foam Factory, Simon Aubin, El Mekki Hamdi, Audrey Joly, Philippe Sarazin, Jacques Lesage, Livain Breau, Mark Spence, Sébastien Gagné

Études primaires

Because of the semi-volatile nature of diisocyanates (being airborne in both physical vapor and particulate phases), their high reactivity and low occupational exposure limits, diisocyanate exposure evaluation has been challenging for industrial hygienists and laboratories. The objective of this study was to compare the toluene diisocyanate (2,4 and 2,6 isomers, TDI) concentration measured by five methods in a flexible polyurethane foam factory using different collection or derivatization approaches. The methods used were: OSHA 42 modified (filter, 1-(2-pyridyl)piperazine) (OSHA), Asset EZ4-NCO (denuder and filter, dibutylamine) (Asset), Iso-Chek (double-filter, 9-(N-methylaminomethyl) anthracene and 1,2-methoxyphenylpiperazine), DAN (filter, 1,8-diaminonaphthalene), and CIP10 (centrifugation, 1,2-methoxyphenylpiperazine). Particle real-time …


On-Site Comparison Of The Osha 47, Asset Ez4-Nco, Iso-Chek, Dan, And Cip10 Methods For Measuring Methylene Diphenyl Diisocyanate (Mdi) At An Oriented-Strand Board (Osb) Factory, Simon Aubin, El Mekki Hamdi, Audrey Joly, Philippe Sarazin, Jacques Lesage, Livain Breau, Mark Spence, Sébastien Gagné Jan 2020

On-Site Comparison Of The Osha 47, Asset Ez4-Nco, Iso-Chek, Dan, And Cip10 Methods For Measuring Methylene Diphenyl Diisocyanate (Mdi) At An Oriented-Strand Board (Osb) Factory, Simon Aubin, El Mekki Hamdi, Audrey Joly, Philippe Sarazin, Jacques Lesage, Livain Breau, Mark Spence, Sébastien Gagné

Études primaires

Diisocyanates are occupational contaminants and known sensitizers causing irritation (skin and respiratory tract) as well as occupational asthma. Because of their physicochemical properties (semi-volatile and high reactivity) and low occupational limits, diisocyanate exposure evaluation is still a challenge nowadays for industrial hygienists and laboratories. The objective of this study was to compare the methylene diphenyl diisocyanate (MDI) concentrations measured by five methods using different collection or derivatization approaches in an oriented-strand board (OSB) factory. The methods used were: OSHA 47 (filter, 1-(2-pyridyl)piperazine) (OSHA), Asset EZ4-NCO (denuder and filter, dibutylamine) (Asset), Iso-Chek (double-filter, 9-(N-methylaminomethyl) anthracene and 1,2-methoxyphenylpiperazine), DAN (filter, 1,8-diaminonaphthalene), and …


Validation Of A Low-Cost Inertial Motion Capture System For Whole-Body Motion Analysis, X. Robert-Lachaine, H. Mecheri, A. Muller, C. Larue, A. Plamondon Jan 2020

Validation Of A Low-Cost Inertial Motion Capture System For Whole-Body Motion Analysis, X. Robert-Lachaine, H. Mecheri, A. Muller, C. Larue, A. Plamondon

Études primaires

While some low-cost inertial motion capture (IMC) systems are now commercially available, generally, they have not been evaluated against gold standard optical motion capture (OMC). The objective was to validate the low-cost Neuron IMC system with OMC. Whole-body kinematics were recorded on five healthy subjects during manual handling of boxes for about 32 min while wearing 17 magnetic and inertial measurement units with Optotrak clusters serving as a reference. The kinematical model was calibrated anatomically for OMC and with poses for IMC. Local coordinate systems were aligned with angular velocities to dissociate differences due to technology or kinematical model. Descriptive …


Comparative Performance Of The Nanoscan And The Classic Smps In Determining N95 Filtering Facepiece Efficiency Against Nanoparticles, Clothilde Brochot, Fariborz Haghighat, Ali Bahloul Jan 2020

Comparative Performance Of The Nanoscan And The Classic Smps In Determining N95 Filtering Facepiece Efficiency Against Nanoparticles, Clothilde Brochot, Fariborz Haghighat, Ali Bahloul

Études primaires

Nanoparticles are defined as particles with at least one dimension in the range of 1–100 nm. Due to the special properties of nanoparticles, they are used in many workplaces, thus leading to occupational exposure. Filtering facepieces (FFPs) are generally used in these workplaces to reduce the exposure. Many studies have measured FFP efficiency in laboratories using a scanning mobility particle sizer (SMPS). The aim of this study was to determine whether a NanoScan could be used to measure FFP efficiency against nanoparticles in workplaces for one type of N95 FFP. The results showed that the NanoScan gave maximum penetration and …


Use Of Magnetic Resonance Image Registration To Estimate Displacement In The Human Earcanal Due To The Insertion Of In-Ear Devices, Simon Benacchio, Olivier Doutres, Arthur Varoquaux, Éric Wagnac, Arnaud Le Troter, Virginie Callot, Franck Sgard Jan 2019

Use Of Magnetic Resonance Image Registration To Estimate Displacement In The Human Earcanal Due To The Insertion Of In-Ear Devices, Simon Benacchio, Olivier Doutres, Arthur Varoquaux, Éric Wagnac, Arnaud Le Troter, Virginie Callot, Franck Sgard

Études primaires

In-ear devices are used in a wide range of applications for which the device's usability and/or efficiency is strongly related to comfort aspects that are influenced by the mechanical interaction between the device and the walls of the earcanal. Although the displacement of the earcanal walls due to the insertion of the device is an important characteristic of this interaction, existing studies on this subject are very limited. This paper proposes a method to estimate this displacement in vivo using a registration technique on magnetic resonance images. The amplitude, the location and the direction of the earcanal wall displacement are …


Estimation Of The Ear Canal Displacement Field Due To In-Ear Device Insertion Using A Registration Method On A Human-Like Artificial Ear, S. Benacchio, O. Doutres, A. Le Troter, A. Varoquaux, E. Wagnac, V. Callot, F. Sgard Jan 2018

Estimation Of The Ear Canal Displacement Field Due To In-Ear Device Insertion Using A Registration Method On A Human-Like Artificial Ear, S. Benacchio, O. Doutres, A. Le Troter, A. Varoquaux, E. Wagnac, V. Callot, F. Sgard

Études primaires

Passive and active in-ear devices (IED) occluding the ear canal are commonly used to (i) protect people from high noise levels (earplugs), (ii) assist people suffering from hearing impairment (hearing aids) or (iii) help people in listening from their sound systems (earbuds). However, the usability and/or efficiency of IEDs can be greatly affected by several discomfort components (physical, acoustical and functional). The mechanical pressure exerted by the IED onto the ear canal walls is greatly suspected to affect the aforementioned comfort components. This physical characteristic is closely related to the displacement field induced by the IED insertion, which has to …


A Comparison Of Lumbar Spine And Muscle Loading Between Male And Female Workers During Box Transfers, Denis Gagnon, André Plamondon, Christian Larivière Jan 2018

A Comparison Of Lumbar Spine And Muscle Loading Between Male And Female Workers During Box Transfers, Denis Gagnon, André Plamondon, Christian Larivière

Études primaires

There is a clear relationship between lumbar spine loading and back musculoskeletal disorders in manual materials handling. The incidence of back disorders is greater in women than men, and for similar work demands females are functioning closer to their physiological limit. It is crucial to study loading on the spine musculoskeletal system with actual handlers, including females, to better understand the risk of back disorders. Extrapolation from biomechanical studies conducted on unexperienced subjects (mainly males) might not be applicable to actual female workers. For male workers, expertise changes the lumbar spine flexion, passive spine resistance, and active/passive muscle forces. However, …


Effect Of Local Magnetic Field Disturbances On Inertial Measurement Units Accuracy, Xavier Robert-Lachaine, Hakim Mecheri, Christian Larue, André Plamondon Jan 2017

Effect Of Local Magnetic Field Disturbances On Inertial Measurement Units Accuracy, Xavier Robert-Lachaine, Hakim Mecheri, Christian Larue, André Plamondon

Études primaires

Inertial measurement units (IMUs), a practical motion analysis technology for field acquisition, have magnetometers to improve segment orientation estimation. However, sensitivity to magnetic disturbances can affect their accuracy. The objective of this study was to determine the joint angles accuracy of IMUs under different timing of magnetic disturbances of various durations and to evaluate a few correction methods. Kinematics from 12 individuals were obtained simultaneously with an Xsens system where an Optotrak cluster acting as the reference system was affixed to each IMU. A handling task was executed under normal laboratory conditions and imposed magnetic disturbances. Joint angle RMSE was …


Use Of The Novel Derivatizing Agent 1,8-Diaminonapthalene With The Cip10 Sampler To Measure 4,4'-Methylene Diphenyl Diisocyanate Atmospheres, Silvia Puscasu, Simon Aubin, Philippe Sarazin, Lucile Richard, Mark Spence, Sébastien Gagné Jan 2017

Use Of The Novel Derivatizing Agent 1,8-Diaminonapthalene With The Cip10 Sampler To Measure 4,4'-Methylene Diphenyl Diisocyanate Atmospheres, Silvia Puscasu, Simon Aubin, Philippe Sarazin, Lucile Richard, Mark Spence, Sébastien Gagné

Études primaires

DAN is a novel derivatizing agent for isocyanate sampling which targets total reactive isocyanate group (TRIG). Field evaluations have been conducted for 4,4’-Methylene diphenyl diisocyanate (MDI) sampling using DAN as the derivatizing agent in a CIP10. The perimidone formed, selective of TRIG, was analyzed in laboratory by liquid chromatography coupled to tandem mass spectrometry. Workplaces using MDI-based polyurethane spray foam and MDI wood product binder were studied. Each study compared the data obtained between the CIP10/DAN, the CIP10/MP, and a reference method. As a first evaluation, the CIP10/DAN sampled simulated MDI spray foam atmosphere in parallel with impingers (reference method) …


Particle Loading Time And Humidity Effects On The Efficiency Of An N95 Filtering Facepiece Respirator Model Under Constant And Inhalation Cyclic Flows, Alireza Mahdavi, Fariborz Haghighat, Ali Bahloul, Clothilde Brochot, Claude Ostiguy Jan 2015

Particle Loading Time And Humidity Effects On The Efficiency Of An N95 Filtering Facepiece Respirator Model Under Constant And Inhalation Cyclic Flows, Alireza Mahdavi, Fariborz Haghighat, Ali Bahloul, Clothilde Brochot, Claude Ostiguy

Études primaires

It is necessary to investigate the efficiencies of filtering facepiece respirators (FFRs) exposed to ultrafine particles (UFPs) for long periods of time, since the particle loading time may potentially affect the efficiency of FFRs. This article aims to investigate the filtration efficiency for a model of electrostatic N95 FFRs with constant and ‘inhalation-only’ cyclic flows, in terms of particle loading time effect, using different humidity conditions. Filters were exposed to generated polydisperse NaCl particles. Experiments were performed mimicking an ‘inhalation-only’ scenario with a cyclic flow of 85 l min –1 as the minute volume [or 170 l min –1 as …