Open Access. Powered by Scholars. Published by Universities.®
- Discipline
- Keyword
-
- Case reports (1)
- Cervical spine imaging (1)
- Emergency medical services (1)
- Event medicine (1)
- Handheld ultrasound (1)
-
- Head imaging (1)
- Iatrogenic injury (1)
- Near infra-red spectroscopy (1)
- Operating room (1)
- POCUS (1)
- Patient safety (1)
- Patient transport (1)
- Pediatric anesthesia (1)
- Point of care ultrasound (1)
- Point-of-care systems (1)
- Portable computed tomography (1)
- Pre-hospital (1)
- Pressure injury (1)
- Skin assessment (1)
- Skin tone (1)
- South Carolina (1)
- Thermal burns (1)
- Tissue assessment (1)
- Transillumination (1)
- Trauma (1)
- Vein finder (1)
Articles 1 - 4 of 4
Full-Text Articles in Equipment and Supplies
Thermal Skin Burns Following Infrared Vein Finder Application In Pediatric Patients: A Report Of 2 Cases And Protocol Revision, Sujata S. Rawlani, Nandini Banad, Jenil Sheth, Raja Narsingrao
Thermal Skin Burns Following Infrared Vein Finder Application In Pediatric Patients: A Report Of 2 Cases And Protocol Revision, Sujata S. Rawlani, Nandini Banad, Jenil Sheth, Raja Narsingrao
HCA Healthcare Journal of Medicine
Background
Peripheral venous cannulation remains a cornerstone of pediatric anesthesia practice. Infrared vein finder devices have gained popularity as aids to improve venous visualization in children with difficult access. However, the thermal hazards associated with certain device types, particularly pocket flashlight-based models, remain underappreciated among clinical staff.
Case Presentation
We report 2 pediatric patients who sustained grade 2 thermal burns at peripheral venous access sites following the use of a pocket flashlight-based infrared vein finder during ophthalmic surgical procedures. The first patient, an 8-month-old girl born at term with appropriate developmental milestones undergoing congenital cataract surgery, developed a ruptured blister …
The Use Of Infra-Red Spectroscopy To Assess Intact Skin Of Various Skin Tones, Mary Lee A. Potter, Stacie Sosa, Charlott Polm, Sherry Campton, Wisam Salameh, Ronnie Klein, Yaniv Cohen
The Use Of Infra-Red Spectroscopy To Assess Intact Skin Of Various Skin Tones, Mary Lee A. Potter, Stacie Sosa, Charlott Polm, Sherry Campton, Wisam Salameh, Ronnie Klein, Yaniv Cohen
HCA Healthcare Journal of Medicine
Background
Pressure injuries (PI) continue to be a serious medical complication in the acute care setting. Industry leaders advocate for the use of objective technologies to provide accurate and quantifiable skin assessments for all patients across diverse skin tones. The Infra-Red Spectroscopy Scanner (IRSS) is a novel non-invasive decision support system (DSS) electro-optic technology that uses near infra-red spectroscopy to examine and assess physical and chemical changes prior to visual skin breakdown in real-time.
Methods
A 2-phase prospective open-label pilot device study was launched under protocol IRM-02-1123 (USA version 3.0, November 1, 2023). In both Phase 1 and Phase 2, …
Using Point-Of-Care Ultrasound For The Medical Management Of Marathoners And Spectators: A Case Series, Jacob D. Pope, Casey Wilson, Kelsey Daller, Jonathan Hardin, Steven Rickett
Using Point-Of-Care Ultrasound For The Medical Management Of Marathoners And Spectators: A Case Series, Jacob D. Pope, Casey Wilson, Kelsey Daller, Jonathan Hardin, Steven Rickett
HCA Healthcare Journal of Medicine
Background
Temporary field hospitals play a crucial role in providing medical care to individuals who experience illnesses and injuries during mass gathering events. Handheld point-of-care ultrasound (POCUS) devices offer an affordable and portable adjunct for emergency care. We present multiple patients from a field hospital during a marathon event in which handheld POCUS devices changed clinical management.
Case Presentation
A 75-year-old man who had fallen was able to be discharged after a lung exam confirmed no rib fractures or pneumothorax. A hypotensive and hypoglycemic 21-year-old man had an echocardiogram confirming volume depletion. He received treatment, and a repeat exam demonstrated …
Portable Head Computed Tomography Protocol For Trauma, Christian Quinones, Alexander Bolufer, Cory Hewitt, Sagun Tuli
Portable Head Computed Tomography Protocol For Trauma, Christian Quinones, Alexander Bolufer, Cory Hewitt, Sagun Tuli
HCA Healthcare Journal of Medicine
The use of portable computed tomography (CT) scanners has been shown to reduce risks associated with intrahospital transport and to expedite imaging in critically ill patients. While their use is established in intensive care units, their utility on intraoperative trauma patients remains underexplored. This paper reviews existing literature on portable CT use, defines appropriate clinical indications, outlines contraindications, and identifies quality metrics and implementation challenges. It also presents a proposed protocol for integrating portable head CT imaging into trauma workflows, focusing on early identification of intracranial or spinal injuries in the operating room. The development and analysis of standardized protocols …