Open Access. Powered by Scholars. Published by Universities.®
- Discipline
- Keyword
-
- Atrophie blanche (1)
- Autonomic modulators (1)
- Bile ducts—Obstruction—Treatment (1)
- Biliary tract—Stents and prostheses (1)
- Buddy balloon (1)
-
- Cardiogenic shock (1)
- Cardiomyopathies—complications (1)
- Case report (1)
- Chronic venous insufficiency (1)
- Clinical trials (1)
- Comorbidity (1)
- Compression stockings (1)
- Compression wrap (1)
- Device therapy (1)
- Endoscopic retrograde cholangiopancreatography (1)
- Females (1)
- Guideline-directed medical therapy (1)
- Heart failure (1)
- Heart failure with reduced ejection fraction (1)
- Heart failure—patients—case studies (1)
- Heart valves—surgery—minimally invasive surgery (1)
- ICD (1)
- Intra-aortic balloon pump (1)
- Lipodermatosclerosis (1)
- Meta-analysis (1)
- Metallic stents (1)
- MitraClip (1)
- Mitral valve—regurgitation—treatment (1)
- Myocardial infarction (1)
- Older people—diseases—case studies (1)
Articles 1 - 7 of 7
Full-Text Articles in Equipment and Supplies
Concomitant Transcatheter Edge-To-Edge Repair For Mitral And Tricuspid Regurgitation For Polyvalvular Disease, Omar Khan, Matthew Summers
Concomitant Transcatheter Edge-To-Edge Repair For Mitral And Tricuspid Regurgitation For Polyvalvular Disease, Omar Khan, Matthew Summers
Department of Medicine Faculty Publications
This patient is a 77-year-old male with non-ischemic cardiomyopathy, severe tricuspid regurgitation, and moderate mitral regurgitation who underwent simultaneous transcatheter edge-to-edge repair of both mitral and tricuspid valves. Post-procedure, the patient exhibited significant symptomatic improvement and reduced regurgitation severity, highlighting the feasibility of dual-valve TEER in high-risk patients.
Combined Snare And Buddy-Balloon Strategy For Failed Valve Crossing In Valve-In-Valve Transcatheter Aortic Valve Replacement, Hira Sarfraz, Muhammad U. Javed, Parth K. Parikh, Joshua A. Cohen, Raymond L. Benza, Matthew R. Summers, Deepak R. Talreja
Combined Snare And Buddy-Balloon Strategy For Failed Valve Crossing In Valve-In-Valve Transcatheter Aortic Valve Replacement, Hira Sarfraz, Muhammad U. Javed, Parth K. Parikh, Joshua A. Cohen, Raymond L. Benza, Matthew R. Summers, Deepak R. Talreja
Department of Medicine Faculty Publications
Background Retrograde valve crossing during valve-in-valve transcatheter aortic valve replacement (ViV TAVR) may fail despite modern delivery systems. Case Summary A 67-year-old man with a degenerated 27-mm Magna Ease bioprosthesis and unfavorable aortic geometry (kinked ascending aorta at a prior surgical graft site) underwent ViV TAVR, where retrograde valve crossing failed despite multiple stiff guidewires and snare traction alone. Successful delivery of a 29-mm Evolut FX+ was ultimately achieved by combining gooseneck-snare traction for coaxial realignment with a partially inflated Tyshak buddy balloon acting as a mechanical ramp across the surgical valve frame. Discussion This case demonstrates a structured, stepwise …
Percutaneous Closure Of Ventricular Septal Rupture After Myocardial Infarction:, Thomas A. Cook, Simone K. Schumaecker, Anjani Patibandla, Nicholas J. Valle, Matthew R. Summers
Percutaneous Closure Of Ventricular Septal Rupture After Myocardial Infarction:, Thomas A. Cook, Simone K. Schumaecker, Anjani Patibandla, Nicholas J. Valle, Matthew R. Summers
Department of Medicine Faculty Publications
BACKGROUND: Ventricular septal rupture (VSR) following acute myocardial infarction is a rare but deadly complication with mortality rates exceeding 90% when left untreated. Coronary ischaemia leads to myocardial necrosis and friability resulting in septal rupture, most commonly 3-5 days post-infarction. The sudden development of a left-to-right shunt causes volume overload in the right ventricle, pulmonary vasculature, and left atrium, precipitating biventricular failure, and cardiogenic shock. Management requires careful consideration of timing and modality of closure along with stabilization with mechanical circulatory support in severe cases.
CASE SUMMARY: A 65-year-old female presented with anterior ST-segment elevation myocardial infarction complicated by VSR …
Comparison Of Fully Covered Self-Expandable Metal Biliary Stents With Or Without Anchoring Double-Pigtail Plastic Stents: A Systematic Review And Meta-Analysis, Samuel Tanner, Fadi Hawa, Alejandra Vargas, Priyata Dutta, Antonio Facciorusso, Jean M. Chalhoub, Jorge D. Machicado
Comparison Of Fully Covered Self-Expandable Metal Biliary Stents With Or Without Anchoring Double-Pigtail Plastic Stents: A Systematic Review And Meta-Analysis, Samuel Tanner, Fadi Hawa, Alejandra Vargas, Priyata Dutta, Antonio Facciorusso, Jean M. Chalhoub, Jorge D. Machicado
Department of Medicine Faculty Publications
Background and AIMS
Fully covered self-expandable metal stents (FcSEMSs) have become the mainstay of treatment for a variety of biliary pathologies. However, FcSEMSs have been associated with a greater rate of stent migration than other types of stents. A technique of anchoring double-pigtail plastic stents (DPPSs) has been proposed to minimize migration of biliary FcSEMSs. Herein, we evaluated the efficacy of anchoring DPPSs among patients treated with biliary FcSEMSs.
Methods
We performed a systematic review using PubMed, EMBASE, and Web of Science from database inception through August 2023. Full-text articles comparing FcSEMSs with or without anchoring DPPSs were included. We …
The Timing For Primary Prevention For Icd In The Current Era Of Pharmacotherapy, Anastasia Shchendrygina, Amin Yehya, Hadi Skouri
The Timing For Primary Prevention For Icd In The Current Era Of Pharmacotherapy, Anastasia Shchendrygina, Amin Yehya, Hadi Skouri
Department of Medicine Faculty Publications
Recent advances in the pharmacological therapy of heart failure with reduced ejection fraction (HFrEF) have significantly impacted the overall survival, heart failure hospitalisations and rates of sudden cardiac death (SCD). In this context, the relevant timing of placing ICDs as primary prevention is a matter of on-going debate. This manuscript provides evidence for an updated view regarding the timing of implanting ICD in eligible patients with HFrEF receiving optimal guideline-directed medical therapy, accounting for the timing to reverse cardiac remodelling (RCR) occurrence and residual SCD risks over time. Clinically significant RCR occurs beyond 3 months of optimal guideline-directed medical therapy, …
Role Of Device Therapy In Complementing Contemporary Medical Management, Yoel Benarroch, Natalie Tapaskar, Amin Yehya
Role Of Device Therapy In Complementing Contemporary Medical Management, Yoel Benarroch, Natalie Tapaskar, Amin Yehya
Department of Medicine Faculty Publications
Heart failure (HF) is a clinical syndrome characterized by signs and symptoms resulting from any structural or functional deficiency of ventricular filling or blood ejection. The mainstay of initial treatment remains lifestyle modifications, guideline-directed medical therapy, and addressing contributing factors. However, the past two decades have come with significant advances in device therapies to improve morbidity and mortality in HF despite evidence-based management as above. Given the rapidly evolving area of HF research and therapeutic development, it is important for clinicians to be familiar with novel therapies and how they can complement medical management. In this review we discuss the …
The Effect Of Inelastic Compression Wraps On The Quality Of Life Of People With Chronic Venous Insufficiency: A Single-Center, Single-Arm Prospective Study, Abby Hargis Smits, Marita Yaghi, Narges Maskan Bermudez, Hadar Lev-Tov
The Effect Of Inelastic Compression Wraps On The Quality Of Life Of People With Chronic Venous Insufficiency: A Single-Center, Single-Arm Prospective Study, Abby Hargis Smits, Marita Yaghi, Narges Maskan Bermudez, Hadar Lev-Tov
Department of Medicine Faculty Publications
Background/Objectives: First line therapy for all manifestations of chronic venous insufficiency (CVI) is compression. However, patients frequently report dissatisfaction with compression stockings. Therefore, there is a need to find alternative therapeutic options that can promote compliance. Here, we investigate the impact of the novel, inelastic compression wrap device on quality of life (QoL) in patients with CVI who have failed therapy with compression stockings in the past. Methods: We conducted a six-week, open-label, single-center, non-blinded, prospective cohort study. The primary endpoint was the change in QoL over 6 weeks as measured by the Chronic Venous Disease Quality of Life Questionnaire …