Instrumental Assessment Of Aero-Resistive Expiratory Muscle Strength Rehabilitation Devices, Angela M. Dietsch, Rahul Krishnamurthy, Kelsey Young, Steven M. Barlow Jan 2024

Instrumental Assessment Of Aero-Resistive Expiratory Muscle Strength Rehabilitation Devices, Angela M. Dietsch, Rahul Krishnamurthy, Kelsey Young, Steven M. Barlow

Department of Special Education and Communication Disorders: Faculty Publications

Purpose

Expiratory muscle strength training (EMST) is increasingly being used to treat voice, cough, and swallowing deficits in a wide range of conditions. However, a multitude of aero-resistive EMST models are commercially available, and the absence of side-by-side comparative data interferes with clinicians’ ability to assess which model is best suited to a particular client’s needs. The primary aim of this research was to test and compare the pressure and flow parameters of six currently available EMST models to help inform clinical decision making.

Method

We identified and tested five devices of each of six different EMST models to generate …


A Preliminary Study Of A Spanish Graphic Novella Targeting Hearing Loss Prevention, Mark Guiberson, Emily Wakefield Sep 2017

A Preliminary Study Of A Spanish Graphic Novella Targeting Hearing Loss Prevention, Mark Guiberson, Emily Wakefield

Department of Special Education and Communication Disorders: Faculty Publications

Purpose: This preliminary study developed a digital graphic novella targeting hearing protection beliefs of Spanish-speaking agricultural workers. Researchers used pretest–posttest interview surveys to establish if the novella had an immediate influence on the participants’ beliefs about noise-induced hearing loss and usage of hearing protection devices.

Method: Researchers developed a digital graphic novella directed to increase knowledge about noise-induced hearing loss and increase the proper use of hearing protection devices. The novella was tailored to meet the specific linguistic and literacy needs of Spanish-speaking agricultural workers. Thirty-one Spanish-speaking farmworkers of Mexican nationality participated. This study included an interview survey with specific …


Towards Highly-Integrated Stereovideoscopy For In Vivo Surgical Robots, Jay Carlson Aug 2014

Towards Highly-Integrated Stereovideoscopy For In Vivo Surgical Robots, Jay Carlson

Department of Electrical and Computer Engineering: Dissertations, Theses, and Student Research

When compared to traditional surgery, laparoscopic procedures result in better patient outcomes: shorter recovery, reduced post-operative pain, and less trauma to incisioned tissue. Unfortunately, laparoscopic procedures require specialized training for surgeons, as these minimally-invasive procedures provide an operating environment that has limited dexterity and limited vision. Advanced surgical robotics platforms can make minimally-invasive techniques safer and easier for the surgeon to complete successfully. The most common type of surgical robotics platforms -- the laparoscopic robots -- accomplish this with multi-degree-of-freedom manipulators that are capable of a diversified set of movements when compared to traditional laparoscopic instruments. Also, these laparoscopic robots …


Measurement And Description Of Dynamics Required For In Vivo Surgical Robotics Via Kinematic Methods, Jacob G. Greenburg Aug 2013

Measurement And Description Of Dynamics Required For In Vivo Surgical Robotics Via Kinematic Methods, Jacob G. Greenburg

Department of Mechanical and Materials Engineering: Dissertations, Theses, and Student Research

With the goal of improved recovery times and reduced trauma to the patient there has been a substantial shift in the medical community’s demand for minimally invasive surgical (MIS) techniques. With the standardization of MIS becoming more commonplace in the medical field there are still many improvements that are desired. Traditional, manual methods of these surgeries require multiple incisions on the abdomen for the tools and instruments to be inserted. The more recent demand has been to localize the incisions into what is being referred to as a Laparoendoscopic Single-Site (LESS) surgery. Furthermore, the manual instruments that are commonly used …


Micromechanical Analysis Of Nanoparticle-Reinforced Dental Composites, Yi Hua, Linxia Gu, Hidehiko Watanabe Jan 2013

Micromechanical Analysis Of Nanoparticle-Reinforced Dental Composites, Yi Hua, Linxia Gu, Hidehiko Watanabe

Department of Mechanical and Materials Engineering: Faculty Publications

The mechanical behavior of TiO2 nanoparticle-reinforced resin-based dental composites was characterized in this work using a three-dimensional nanoscale representative volume element. The impacts of nanoparticle volume fraction, aspect ratio, stiffness, and interphase zone between the resin matrix and nanoparticle on the bulk properties of the composite were characterized. Results clearly demonstrated the mechanical advantage of nanocomposites in comparison to microfiber-reinforced composites. The bulk response of the nanocomposite could be further enhanced with the increased nanoparticle volume fraction, or aspect ratio, while the influence of nanoparticle stiffness was minimal. The effective Young’s modulus and yield strength of the composite was …


Effects Of Arterial Strain And Stress In The Prediction Of Restenosis Risk: Computer Modeling Of Stent Trials, Shijia Zhao, Linxia Gu, Stacey R. Froemming Jan 2012

Effects Of Arterial Strain And Stress In The Prediction Of Restenosis Risk: Computer Modeling Of Stent Trials, Shijia Zhao, Linxia Gu, Stacey R. Froemming

Department of Mechanical and Materials Engineering: Faculty Publications

Purpose — In-stenting restenosis is one of the major complications after stenting. Clinical trials of various stent designs have reported different restenosis rates. However, quantitative correlation between stent features and restenosis statistics is scant. In this work, it is hypothesized that stress concentrations on arterial wall caused artery injury, which initiates restenosis. The goal is to assess the correlation between stent-induced arterial stress and strain and the documented restenosis rates.

Methods — Six commercially available stents, including balloon-expandable stents and self-expanding stents, were virtually implanted into the arteries through finite element method. The resulted peak Von Mises stress, principal stress, …


An In Vitro Evaluation Of Commercially Available Disposable Prophylaxis Angles, Caren M. Barnes, Lisa S. Fleming, Carl M. Russell Nov 1991

An In Vitro Evaluation Of Commercially Available Disposable Prophylaxis Angles, Caren M. Barnes, Lisa S. Fleming, Carl M. Russell

College of Dentistry: Faculty Publications

Although a number of manufacturers are marketing disposable prophylaxis angles, no literature exists regarding the mechanical efficacy and efficiency of these products. It was the purpose of this in vitro evaluation to compare and evaluate five brands of commercially available disposable prophylaxis angles for vibration, noise, heat rise, and torque. Random samples of each brand of disposable prophylaxis angle were utilized. Vibration was measured with a height gauge and running motor; noise was measured with a sound meter and heat rise was measured from 68°F on the head and body of the disposable prophylaxis angles, and torque required to destroy …


An In Vivo Comparison Of Commercially Available Disposable Prophylaxis Angles, Lisa S. Fleming, Caren M. Barnes, Carl M. Russell Nov 1991

An In Vivo Comparison Of Commercially Available Disposable Prophylaxis Angles, Lisa S. Fleming, Caren M. Barnes, Carl M. Russell

College of Dentistry: Faculty Publications

A wide variety of disposable infection control products is being marketed including disposable prophylaxis angles. It was the purpose of this in vivo investigation to evaluate the clinical efficacy of five different brands of commercially available disposable prophylaxis angles. Utilizing a splitmouth design. 11 dental hygienists evaluated disposable prophylaxis angles while completing a routine oral prophylaxis. Fifty samples each of Brahler. Ash/Dentsply, Denticator. and Young Dental angles were compared to a control angle (Teledyne Getz). A questionnaire was completed by each operator following patient treatment (a total of 161 patients was treated). The questionnaire asked questions in which the four …


The Management Of Aerosols With Airpolishing Delivery Systems, Caren M. Barnes Jul 1991

The Management Of Aerosols With Airpolishing Delivery Systems, Caren M. Barnes

College of Dentistry: Faculty Publications

In summary. aerosol production is inherent with airpolishers. as well as other dental equipment such as handpieces, ultrasonic scalers, and air/water syringes. By practicing prudent infection control techniques and utilizing proper operating techniques, the clinician can continue to enjoy the time-efficient and efficacious benefits of airpolishers, while ensuring a maximum protection from aerosols for the patient and the operator.