Open Access. Powered by Scholars. Published by Universities.®
- Discipline
- Keyword
-
- Microneedles (2)
- Outcomes research (2)
- Arrhythmia (1)
- Carbamazepine (1)
- Defibrillator shocks (1)
-
- Diabetes (1)
- Dissolving microneedles (1)
- Drug delivery (1)
- Epilepsy (1)
- Hydrogel-forming microneedles (1)
- Implantable cardioverter‐defibrillator (1)
- Implantable cardioverter‐defibrillators (1)
- Inappropriate shock (1)
- Insulin pumps (1)
- Sudden cardiac death (1)
- Tiagabine hydrochloride (1)
- Transdermal (1)
- Transdermal drug delivery (1)
Articles 1 - 5 of 5
Full-Text Articles in Equipment and Supplies
Device Therapies Among Patients Receiving Primary Prevention Implantable Cardioverter-Defibrillators In The Cardiovascular Research Network, Robert T. Greenlee, Alan S. Go, Pamela N. Peterson, Andrea E. Cassidy-Bushrow, Charles Gaber, Romel Garcia-Montilla, Alan H. Kadish
Device Therapies Among Patients Receiving Primary Prevention Implantable Cardioverter-Defibrillators In The Cardiovascular Research Network, Robert T. Greenlee, Alan S. Go, Pamela N. Peterson, Andrea E. Cassidy-Bushrow, Charles Gaber, Romel Garcia-Montilla, Alan H. Kadish
Office of the President Publications and Research
BACKGROUND: Primary prevention implantable cardioverter-defibrillators (ICDs) reduce mortality in selected patients with left ventricular systolic dysfunction by delivering therapies (antitachycardia pacing or shocks) to terminate potentially lethal arrhythmias; inappropriate therapies also occur. We assessed device therapies among adults receiving primary prevention ICDs in 7 healthcare systems.
METHODS AND RESULTS: We linked medical record data, adjudicated device therapies, and the National Cardiovascular Data Registry ICD Registry. Survival analysis evaluated therapy probability and predictors after ICD implant from 2006 to 2009, with attention to Centers for Medicare and Medicaid Services Coverage With Evidence Development subgroups: left ventricular ejection fraction, 31% to 35%; …
Comparison Of Inappropriate Shocks And Other Health Outcomes Between Single- And Dual-Chamber Implantable Cardioverter-Defibrillators For Primary Prevention Of Sudden Cardiac Death: Results From The Cardiovascular Research Network Longitudinal Study Of Implantable Cardioverter-Defibrillators, Pamela N. Peterson, Robert T. Greenlee, Alan S. Go, David J. Magid, Andrea Cassidy-Bushrow, Romel Garcia-Montilla, Alan H. Kadish
Comparison Of Inappropriate Shocks And Other Health Outcomes Between Single- And Dual-Chamber Implantable Cardioverter-Defibrillators For Primary Prevention Of Sudden Cardiac Death: Results From The Cardiovascular Research Network Longitudinal Study Of Implantable Cardioverter-Defibrillators, Pamela N. Peterson, Robert T. Greenlee, Alan S. Go, David J. Magid, Andrea Cassidy-Bushrow, Romel Garcia-Montilla, Alan H. Kadish
Office of the President Publications and Research
Background In US clinical practice, many patients who undergo placement of an implantable cardioverter‐defibrillator (ICD) for primary prevention of sudden cardiac death receive dual‐chamber devices. The superiority of dual‐chamber over single‐chamber devices in reducing the risk of inappropriate ICD shocks in clinical practice has not been established. The objective of this study was to compare risk of adverse outcomes, including inappropriate shocks, between single‐ and dual‐chamber ICDs for primary prevention.
Methods and Results We identified patients receiving a single‐ or dual‐chamber ICD for primary prevention who did not have an indication for pacing from 15 hospitals within 7 integrated health …
The Influence Of Solid Microneedles On The Transdermal Delivery Of Selected Antiepileptic Drugs, Julia Nguyen, Kevin B. Ita, Matthew J. Morra, Inna E. Popova
The Influence Of Solid Microneedles On The Transdermal Delivery Of Selected Antiepileptic Drugs, Julia Nguyen, Kevin B. Ita, Matthew J. Morra, Inna E. Popova
Faculty Publications & Research of the TUC College of Pharmacy
The aim of this project was to examine the effect of microneedle rollers on the percutaneous penetration of tiagabine hydrochloride and carbamazepine across porcine skin in vitro. Liquid chromatography-mass spectrometric analysis was carried out using an Agilent 1200 Series HPLC system coupled to an Agilent G1969A TOF-MS system. Transdermal flux values of the drugs were determined from the steady-state portion of the cumulative amount versus time curves. Following twelve hours of microneedle roller application, there was a 6.74-fold increase in the percutaneous penetration of tiagabine hydrochloride (86.42 ± 25.66 µg/cm2/h) compared to passive delivery (12.83 ± 6.30 µg/cm …
Transdermal Delivery Of Drugs With Microneedles—Potential And Challenges, Kevin B. Ita
Transdermal Delivery Of Drugs With Microneedles—Potential And Challenges, Kevin B. Ita
Faculty Publications & Research of the TUC College of Pharmacy
Transdermal drug delivery offers a number of advantages including improved patient compliance, sustained release, avoidance of gastric irritation, as well as elimination of pre-systemic first-pass effect. However, only few medications can be delivered through the transdermal route in therapeutic amounts. Microneedles can be used to enhance transdermal drug delivery. In this review, different types of microneedles are described and their methods of fabrication highlighted. Microneedles can be fabricated in different forms: hollow, solid, and dissolving. There are also hydrogel-forming microneedles. A special attention is paid to hydrogel-forming microneedles. These are innovative microneedles which do not contain drugs but imbibe interstitial …
Insulin Pumps: Beyond Basal-Bolus, Richard Millstein, Nancy Mora Becerra, Jay H. Shubrook
Insulin Pumps: Beyond Basal-Bolus, Richard Millstein, Nancy Mora Becerra, Jay H. Shubrook
Faculty Publications & Research of the TUC College of Osteopathic Medicine
Insulin pumps are a major advance in diabetes management, making insulin dosing easier and more accurate and providing great flexibility, safety, and efficacy for people who need basal-bolus insulin therapy. They are the preferred treatment for people with type 1 diabetes and many with type 2 diabetes who require insulin. This article reviews the basics of how insulin pumps work, who benefits from a pump, and how to manage inpatients and outpatients on insulin pumps.