Open Access. Powered by Scholars. Published by Universities.®
- Discipline
-
- Anatomy (2)
- Anesthesia and Analgesia (1)
- Biological and Chemical Physics (1)
- Biotechnology (1)
- Cardiology (1)
-
- Cardiovascular System (1)
- Chemicals and Drugs (1)
- Critical Care (1)
- Critical Care Nursing (1)
- Diagnosis (1)
- Enzymes and Coenzymes (1)
- Health and Medical Administration (1)
- Investigative Techniques (1)
- Life Sciences (1)
- Medical Sciences (1)
- Medical Specialties (1)
- Nursing (1)
- Other Medical Sciences (1)
- Pediatric Nursing (1)
- Physical Sciences and Mathematics (1)
- Physics (1)
- Quality Improvement (1)
- Respiratory System (1)
- Surgery (1)
- Surgical Procedures, Operative (1)
- Keyword
- Publication
- Publication Type
Articles 1 - 4 of 4
Full-Text Articles in Equipment and Supplies
Implementation Of A Planned Extubation Nurse-Led Safety Bundle In A Pediatric Cardiac Intensive Care Unit, Broderick Sutton
Implementation Of A Planned Extubation Nurse-Led Safety Bundle In A Pediatric Cardiac Intensive Care Unit, Broderick Sutton
Doctor of Nursing Practice Final Project Abstract
Purpose: To implement and evaluate a nurse-led planned extubation safety bundle designed to improve nurse preparedness, interdisciplinary communication, workflow consistency, and confidence during planned extubation events in a pediatric Cardiac Intensive Care Unit (CICU).
Background: Planned extubation in critically ill pediatric cardiac patients requires effective interdisciplinary coordination. Variability in nurse preparation, communication, and knowledge of sedation pharmacokinetics contributed to workflow inefficiencies and patient safety concerns. Evidence supports standardized nurse-led protocols to improve extubation readiness and reduce practice variability.
Methodology: A prospective pre-post quality improvement project was conducted over eight weeks in a pediatric CICU. The intervention included a nurse-led planned …
Transcutaneous Energy Transmission: Can We Do It Now?, Yuriy Pya
Transcutaneous Energy Transmission: Can We Do It Now?, Yuriy Pya
The VAD Journal
The percutaneous driveline used in contemporary LVADs presents a continuous risk of infection for the duration of support. Minimizing infection in durable mechanical circulatory support systems requires total implantation of all components and energy transfer by means other than percutaneous drivelines. A novel coplanar energy transfer (CET) system, similar to the original transcutaneous energy transfer (TET) design, is unique by incorporating two large rings with coil-within-the-coil topology to ensure strong resonance power. The CET system consists of an internal integrated controller, a battery coupled with an internal thoracic coil ring, and the LVAD pump. External equipment includes a power transmission …
An Automated Syringe Pump System For Improving The Reproducibility Of Dynamic Hyperpolarized Mri Phantoms, Harlee G. Harrison
An Automated Syringe Pump System For Improving The Reproducibility Of Dynamic Hyperpolarized Mri Phantoms, Harlee G. Harrison
Dissertations and Theses (Open Access)
AN AUTOMATED SYRINGE PUMP SYSTEM FOR IMPROVING THE REPRODUCIBILITY OF DYNAMIC HYPERPOLARIZED MRI PHANTOMS
Harlee Grace Harrison, B.S.
Advisory Professor: James Bankson, Ph.D.
Magnetic Resonance Imaging (MRI) is a powerful tool in the diagnosis of cancer due to its ability to provide good soft tissue contrast and image resolution without the use of ionizing radiation. The use of hyperpolarized pyruvate as a contrast agent for tumor metabolism during MR scans has the potential to provide information about tumor metabolism in vivo that is not available from traditional imaging measurements or any other method. Hyperpolarization is achieved through dynamic nuclear polarization. …
Evaluation Of The Quantitative Accuracy Of A Commercially-Available Positron Emission Mammography Scanner, Adam Springer
Evaluation Of The Quantitative Accuracy Of A Commercially-Available Positron Emission Mammography Scanner, Adam Springer
Dissertations and Theses (Open Access)
Objective: The PEM Flex Solo II (Naviscan, Inc., San Diego, CA) is currently the only commercially-available positron emission mammography (PEM) scanner. This scanner does not apply corrections for count rate effects, attenuation or scatter during image reconstruction, potentially affecting the quantitative accuracy of images. This work measures the overall quantitative accuracy of the PEM Flex system, and determines the contributions of error due to count rate effects, attenuation and scatter.
Materials and Methods: Gelatin phantoms were designed to simulate breasts of different sizes (4 – 12 cm thick) with varying uniform background activity concentration (0.007 – 0.5 μCi/cc), cysts and …