Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 8 of 8

Full-Text Articles in Equipment and Supplies

Magnification In Images Produced By Five Popular Digital Lateral Cephalometric Machines, Gretchen Marie Schnepper Sep 2005

Magnification In Images Produced By Five Popular Digital Lateral Cephalometric Machines, Gretchen Marie Schnepper

Loma Linda University Electronic Theses, Dissertations & Projects

Modern digital lateral cephalometric images are produced by machines that vary in a number of critical features such as: 1) machine geometry, 2) movement (or lack of movement) of the x-ray source, 3) movement (or lack of movement) or x-ray detectors, 4) cephalostat geometry and 5) digital data manipulations by proprietary software. The purpose of this study was to evaluate the magnification characteristics of images produced by five commercial digital lateral cephalometric machines. These digital image magnification characteristics were then compared with images produced by an analog cephalometric machine. The two goals of this study were to: 1) measure the …


The Effects Of Second Molar Extractions In Conjunction With Bionator Treatment, Mohammed Toufic Jeiroudi Apr 1982

The Effects Of Second Molar Extractions In Conjunction With Bionator Treatment, Mohammed Toufic Jeiroudi

Loma Linda University Electronic Theses, Dissertations & Projects

The intent of this paper is to evaluate the effects of second molar extractions in conjunction with Bionator treatments. Eighteen Orthodontic patients were used in this study. All had had second molars extracted. Lateral cephalometric radiographs were traced and used to evaluate the treatment. The average age at time of extraction was 13 years, 3 months. The average treatment time was 38.3 months.

There were some orthopedic changes. The convexity decreased significantly, the condyle axis increased more than expected in normal growth. Also, the lower facial height and facial axis both became more dolichotype (open).

The upper and lower incisors …


Kinesiology Of Knee Flexion Deformity Using Electromyography, Paul J. Roby Mar 1973

Kinesiology Of Knee Flexion Deformity Using Electromyography, Paul J. Roby

Loma Linda University Electronic Theses, Dissertations & Projects

A kinesiological electromyographic study was completed to determine the relative changes in muscle activity as a person walks and stands with different degrees of knee flexion deformity. The ultimate aim was to establish criteria for appropriate preventive and corrective measures relating to knee flexion deformity.

Six different muscles were implanted with wire electrodes. The subjects performed a series of walking and standing experiments with the knee flexed at selected angles by a locking leg brace to simulate knee flexion deformity. The electromyographic action potentials were monitored by analog tapes, oscilloscopes and closed circuit television. The analog tapes were displayed on …


Patient Preference In Two Types Of Colostomy Irrigations, Mildred Ann Marks Jun 1972

Patient Preference In Two Types Of Colostomy Irrigations, Mildred Ann Marks

Loma Linda University Electronic Theses, Dissertations & Projects

The purposes of this study were threefold: (1) to find which method of colostomy irrigation (enema bag vs. bulb syringe) was best accepted by colostomy patients; (2) to functionally evaluate the two types of colostomy irrigation methods; and (3) to report the results of this study to medical personnel interested in advancements for colostomy irrigations. The population in this study consisted of colostomy patients who had irrigated on a regular basis with the bag technique for a minimum of six months. Twelve colostomates completed this study by recording the parameter of time, amount of irrigation fluid used, quality of return, …


An Evaluation Of Cuspid And Anterior Retraction Using Burstone Mechanics In First Bicuspid Extraction Cases, George Rodney Heath May 1972

An Evaluation Of Cuspid And Anterior Retraction Using Burstone Mechanics In First Bicuspid Extraction Cases, George Rodney Heath

Loma Linda University Electronic Theses, Dissertations & Projects

This study was conducted to clinically evaluate cuspid and anterior retraction in first bicuspid extraction cases using the Burstone segmented arch technique. More specifically interest was centered on rate of cuspid and anterior retraction, anchorage preservation or control, difficulty of appliance adjustments, time involved and frequency of adjustments, total retraction time, patient discomfort, root resorption, as well as a complete cephalometric appraisal. Six patients were treated for seven months with measurements and records taken to asses (sic) the above desired information.

The results of the patients undergoing lower cuspid retraction showed a mean percentage of 26.0% for the molars and …


Relationship Of Ventilation Ability And Positioning In Left-Sided Congestive Heart Failure Patients, Nancy E. Carson Mar 1971

Relationship Of Ventilation Ability And Positioning In Left-Sided Congestive Heart Failure Patients, Nancy E. Carson

Loma Linda University Electronic Theses, Dissertations & Projects

Proper positioning is used to relieve dyspnea, edema, and fatigue in congestive heart failure patients. According to the review of literature, improved ventilation as measured by specific lung volumes and lung mechanics occurred with upright positioning in normal persons. The effects of specific changes in lung volumes related to position change in congestive heart failure patients has not been documented in literature, although various recommendations related to positioning are made. This exploratory study was undertaken with nine congestive heart failure patients to see if a relationship existed between degree of head elevation and lung ventilation ability as measured by water-bell …


A Study To Demonstrate The Immediate Destination Of An Embolus Formed In The Lumen Of A Peripheral Venous Catheter, Rosemarie Morikone Emori May 1970

A Study To Demonstrate The Immediate Destination Of An Embolus Formed In The Lumen Of A Peripheral Venous Catheter, Rosemarie Morikone Emori

Loma Linda University Electronic Theses, Dissertations & Projects

This study was designed to show the immediate destination of an embolus formed in the lumen of an intravenous catheter placed in a peripheral vessel. The hypothesis stated that clots injected into a peripheral vessel will lodge in the lungs. A subhypothesis was that the clot may lodge anywhere along the circulatory pathway.

Indications of need for the study as shown by the review of literature were the following: (1) the complications resulting from the frequent use of intravenous polyethylene catheters, (2) experimental studies that showed that clots were formed around intravenous catheters, (3) the evidence that intravenous catheters predispose …


Biochemical Properties Of Salmonella Potsdam Bacteriophage P4/2, Clyde L. Roggenkamp Sep 1966

Biochemical Properties Of Salmonella Potsdam Bacteriophage P4/2, Clyde L. Roggenkamp

Loma Linda University Electronic Theses, Dissertations & Projects

Over 90% recovery of phage P4/2 was realized with differential centrifugation concentration and purification, whereas only about 16% was recovered from the aqueous two-phase polymer - Genetron - ECTEOLA-cellulose column system. Purity of preparations was greatest with the density gradient centrifugation (A260 = 2.66 and A280 = 1.80 per 1012 plaque-forming units). With the chemical system of concentration and purification followed by an ECTEOLA anion exchange run, the A260 was 6.6 and the A280 was 4.3.

Three tests were employed to determine the configuration of P4/2 DNA: (1) a formalin denaturation test, (2) a thermal …