Open Access. Powered by Scholars. Published by Universities.®
- Discipline
-
- Dentistry (6)
- Diseases (6)
- Medical Specialties (3)
- Wounds and Injuries (3)
- Physical Sciences and Mathematics (2)
-
- Surgery (2)
- Anatomy (1)
- Artificial Intelligence and Robotics (1)
- Bacterial Infections and Mycoses (1)
- Behavior and Behavior Mechanisms (1)
- Biological Phenomena, Cell Phenomena, and Immunity (1)
- Climate (1)
- Computer Sciences (1)
- Dental Materials (1)
- Eye Diseases (1)
- Health Services Administration (1)
- Medical Sciences (1)
- Neoplasms (1)
- Oceanography and Atmospheric Sciences and Meteorology (1)
- Ophthalmology (1)
- Psychiatry and Psychology (1)
- Public Health (1)
- Surgical Procedures, Operative (1)
- Therapeutics (1)
- Tissues (1)
- Keyword
-
- 3D printing (1)
- Anterior Crown (1)
- Backfill (1)
- CD47 (1)
- Cavitation (1)
-
- Climate change (1)
- Complex retrieval (1)
- Composite Restoration (1)
- Crown Retention (1)
- Daptomycin (1)
- Dermatologic surgery (1)
- Dye Leakage (1)
- Endodontic Access (1)
- Endodontics (1)
- Gene therapy (1)
- Gutta Percha (1)
- Heating Cycles (1)
- Immunotherapy (1)
- Inferior vena cava filter (1)
- Inferior vena cava filter complication (1)
- Medical commentary (1)
- Microbubbles (1)
- Microleakage (1)
- Microspheres (1)
- Mouse model (1)
- NightGuard (1)
- Oncolytic virus (1)
- Resin-Based Barrier (1)
- Retrieval program (1)
- Root Canal Therapy (1)
Articles 1 - 13 of 13
Full-Text Articles in Equipment and Supplies
Ophthoacr (Ophthalmology Automated Chart Review): An Ai-Powered Tool For Complete Automation Of Ophthalmology Chart Reviews And Cohort Data Analysis, Karen M. Chen, Kevin W. Chen, Vlad Diaconita, Stanley Chang, Leejee H. Suh
Ophthoacr (Ophthalmology Automated Chart Review): An Ai-Powered Tool For Complete Automation Of Ophthalmology Chart Reviews And Cohort Data Analysis, Karen M. Chen, Kevin W. Chen, Vlad Diaconita, Stanley Chang, Leejee H. Suh
School of Medicine Faculty Publications
Purpose: Retrospective chart reviews in ophthalmology are essential for gaining clinical insights, but they remain labor-intensive and prone to error. Despite digitization through electronic health records, extracting and interpreting lengthy, unstructured patient histories remains challenging, particularly in ophthalmology, which relies heavily on both imaging and text-based reports. We introduce OphthoACR, a Health Insurance Portability and Accountability Act-compliant artificial intelligence (AI)-powered tool for automated chart review and cohort analyses in ophthalmology. Methods: OphthoACR was applied to extract 16 variables of increasing task difficulty from the complete chart histories of 91 patients who underwent secondary intraocular lens surgery at the Columbia University …
Establishment Of An Inferior Vena Cava Filter Retrieval Program: The Effect On Trauma And Non-Trauma Patient Populations, Katelyn Gill, Hector Ferral, Alexandra H. Fairchild, Bahri Üstünsöz, Dan F. Laney Iv, John Hunt, Jonathan E. Schoen, Alan Marr, Patrick Greiffenstein, Lance Stuke, Alison A. Smith
Establishment Of An Inferior Vena Cava Filter Retrieval Program: The Effect On Trauma And Non-Trauma Patient Populations, Katelyn Gill, Hector Ferral, Alexandra H. Fairchild, Bahri Üstünsöz, Dan F. Laney Iv, John Hunt, Jonathan E. Schoen, Alan Marr, Patrick Greiffenstein, Lance Stuke, Alison A. Smith
School of Medicine Faculty Publications
PURPOSE: This study aimed to compare the effect of establishing an inferior vena cava filter (IVCF) retrieval program (IVCFRP) on the IVCF retrieval rates in trauma and non-trauma patients. METHODS: This was an institutional review board-approved retrospective study. IVCF retrieval in trauma and non-trauma patients was compared before and after the establishment of an IVCFRP in a single Level I Trauma Center. The IVCFRP at our institution was established in April 2020. All patients who underwent IVCF placement between January 2016 and March 2020 were compared with patients who had an IVCF placed between April 2020 and June 2024. A …
The Effects Of Rubber Dam Clamps On Zirconia Crown Restorations, Haley D. Kessler, Albert F. Mcmullen Iii, Hunter Kortum, Edwin Kee, Thomas E. Lallier
The Effects Of Rubber Dam Clamps On Zirconia Crown Restorations, Haley D. Kessler, Albert F. Mcmullen Iii, Hunter Kortum, Edwin Kee, Thomas E. Lallier
School of Dentistry Faculty Publications
Rubber dam isolation is crucial in providing sterility and a controlled environment when performing root canal therapy. Rubber dam clamps have been controversial due to their rigidity and composition, which is thought to cause damage to zirconia full coverage crowns. This study evaluated three types of zirconia crowns anterior 5Y, premolar 4Y, and molar 3Y to assess their resistance to damage from rubber dam clamps. Of the 30 total zirconia crowns that were tested for damage following the usage of rubber dam clamps, no fractures or chips were observed. There was no significant difference between the negative control group, and …
Evaluation Of Different Resin-Based Barriers In Reducing Microleakage In Restoratively Compromised Posterior Teeth During Rubber Dam Isolation: An Ex Vivo Study, Carolina Becerra, Albert F. Mcmullen Iii, Joon Koh, Thomas E. Lallier
Evaluation Of Different Resin-Based Barriers In Reducing Microleakage In Restoratively Compromised Posterior Teeth During Rubber Dam Isolation: An Ex Vivo Study, Carolina Becerra, Albert F. Mcmullen Iii, Joon Koh, Thomas E. Lallier
School of Dentistry Faculty Publications
Introduction: The rubber dam has been a standard in endodontic practice for over 140 years, providing critical isolation to prevent microbial contamination during root canal therapy. However, studies indicate that microleakage between the rubber dam and tooth structure may still occur, potentially leading to bacterial infiltration. Various resin-based barriers have been introduced to enhance isolation and minimize leakage. This study aimed to evaluate the efficacy of four resin-based barriers in reducing microleakage during endodontic procedures. Methods: Forty extracted human mandibular molars were selected, stored in distilled water, and standardized for experimental conditions. Standard endodontic access was created, and the mesiobuccal …
Comparing Gutta Percha Backfill Leakage Over Multiple Heating Cycles, Hannah Battle, Thomas E. Lallier, Landon Boenke, Albert F. Mcmullen Iii
Comparing Gutta Percha Backfill Leakage Over Multiple Heating Cycles, Hannah Battle, Thomas E. Lallier, Landon Boenke, Albert F. Mcmullen Iii
School of Dentistry Faculty Publications
Introduction: Warm vertical compaction of gutta-percha is a commonly used obturation technique due to the material’s thermoplastic properties. However, gutta-percha in backfill systems is often heated, cooled, and reheated multiple times before use, potentially altering its physical properties. This study investigated whether repeated heat cycling affects the sealing ability of gutta-percha, as measured by coronal dye leakage. Methods: Forty extracted single-rooted human teeth were cleaned, shaped, and randomly divided into four groups (n = 10) based on the number of heating cycles the gutta-percha underwent prior to obturation: Group A (1 cycle), Group B (3 cycles), Group C (5 cycles), …
Effect Of Access Cavity Preparation And Cement On The Fracture Load Of Translucent Zirconia Crowns, Andrea Fenton, Amir H. Nejat, Edwin Kee, Xiaoming Xu, Albert F. Mcmullen Iii
Effect Of Access Cavity Preparation And Cement On The Fracture Load Of Translucent Zirconia Crowns, Andrea Fenton, Amir H. Nejat, Edwin Kee, Xiaoming Xu, Albert F. Mcmullen Iii
School of Dentistry Faculty Publications
Purpose: To evaluate the effect of endodontic access hole preparation and choice of luting cement on the fracture resistance of translucent zirconia (5Y) crowns. Materials and Methods: Polymethylmethacrylate (PMMA) dies, representing a prepared maxillary molar tooth, were milled. Translucent zirconia crowns were milled from 5Y (Cercon XTML) zirconia discs and sintered. Forty crowns were divided into four groups (n = 10 per group) based on access hole preparation (accessed, non-accessed) and type of luting cement (resin cement, resin modified glass ionomer (RMGI) cement). Crowns were cemented on the PMMA dies with either resin cement (Panavia SA Cement Universal, Kuraray Noritake …
Effect Of Endodontic Access Preparation On The Retention Of Zirconia Crowns With Temporary Or Permanent Access Hole Restorations: An In Vitro Study, J. Nick Sanders, Amir H. Nejat, Peter Dupree, Edwin Kee, Madeleine E. Raymond, Fred Mcmullen
Effect Of Endodontic Access Preparation On The Retention Of Zirconia Crowns With Temporary Or Permanent Access Hole Restorations: An In Vitro Study, J. Nick Sanders, Amir H. Nejat, Peter Dupree, Edwin Kee, Madeleine E. Raymond, Fred Mcmullen
School of Dentistry Faculty Publications
Objectives: To evaluate the effect endodontic access preparation had on the retention of anterior zirconia crowns after restoring the access hole with temporary versus permanent restorative materials. Methods: 30 anterior zirconia crowns were milled from 5Y-TZP zirconia and bonded to a 3D printed die with resin cement. Crowns were randomly divided into three groups including negative control (NC, n = 10) with no endodontic access preparation; positive control (PC, N = 10) received endodontic access preparation and was restored with a temporary restorative material (Cavit); composite restoration (CR, N = 10) received an endodontic access preparation and then the access …
The Effect Of Different Surface Treatments On The Roughness, Translucency, And Staining Of 3d-Printed Occlusal Device Materials, Silvia Rojas Rueda, Hanna Sepsick, Mohammed Hammamy, Amir H. Nejat, Edwin Kee, Nathaniel C. Lawson
The Effect Of Different Surface Treatments On The Roughness, Translucency, And Staining Of 3d-Printed Occlusal Device Materials, Silvia Rojas Rueda, Hanna Sepsick, Mohammed Hammamy, Amir H. Nejat, Edwin Kee, Nathaniel C. Lawson
School of Dentistry Faculty Publications
OBJECTIVES: To compare surface treatments (as-printed, optical polish, resin-coated, polished) of two 3D-printed occlusal device materials (KeySplint Soft and NightGuard Flex 2) cured with or without glycerin for surface roughness, translucency, and coffee staining. MATERIALS AND METHODS: Discs (2 mm thick) from two 3D-printed occlusal resins (KeySplint Soft and NightGuard Flex 2) were printed using a DLP 3D printer (SprintRay Pro 95), cleaned (ProWash S), and cured (ProCure 2) with or without glycerin. Some specimens were printed in an optical polish tank. Specimens were either as-printed, resin-coated, or polished. Reference milled (ProArt CAD Splint) and heat-cured (Excel Formula Heat Cure …
Reducing Medical Waste, George M. Jeha, Stanislav N. Tolkachjov
Reducing Medical Waste, George M. Jeha, Stanislav N. Tolkachjov
School of Medicine Faculty Publications
No abstract provided.
Microbubble-Protected Oncolytic Virotherapy Targeted By Sonoporation Induces Tumor Necrosis And T-Lymphocyte Infiltration In Humanized Mice Bearing Triple-Negative Breast Cancer, Juliana Sitta, Flavia De Carlo, Imani Kirven, John H. Tackett, Patrice Penfornis, George Clement Dobbins, Mallory Barbier, Luis Del Valle, Clayton T. Larsen, Ernest G. Schutt, Rhodemann Li, Candace M. Howard, Pier Paolo Claudio
Microbubble-Protected Oncolytic Virotherapy Targeted By Sonoporation Induces Tumor Necrosis And T-Lymphocyte Infiltration In Humanized Mice Bearing Triple-Negative Breast Cancer, Juliana Sitta, Flavia De Carlo, Imani Kirven, John H. Tackett, Patrice Penfornis, George Clement Dobbins, Mallory Barbier, Luis Del Valle, Clayton T. Larsen, Ernest G. Schutt, Rhodemann Li, Candace M. Howard, Pier Paolo Claudio
School of Medicine Faculty Publications
Oncolytic virotherapy has shown great promise in mediating targeted tumor destruction through tumor-selective replication and induction of anti-tumor immunity; however, obstacles remain for virus candidates to reach the clinic. These include avoiding neutralizing antibodies, preventing stimulation of the adaptive immune response during intravenous administration, and inducing sufficient apoptosis and immune activation so that the body's defense can work to eradicate systemic disease. We have developed a co-formulation of oncolytic viruses (OVs) with Imagent lipid-encapsulated, perfluorocarbon microbubbles (MBs) to protect the OVs from the innate and adaptive immune system. Once inside the MB, the viral particles become acoustically active such that …
A Novel Sequential Compression Appliance To Reduce Scarring Of The Face, Michelle N. Dwertman, Henry B. Huson
A Novel Sequential Compression Appliance To Reduce Scarring Of The Face, Michelle N. Dwertman, Henry B. Huson
School of Medicine Faculty Publications
56th Annual Meeting of the American Burn Association, ABA 2024; April 9 - 12, 2024, Chicago, IL
Select Survey Of Human Cadaver Skin Allograft Utilization By 21 Senior Academic Burn Surgeons, William Hickerson, Franco Aveau, Narayan Iyer, James Jeng, Victor Joe
Select Survey Of Human Cadaver Skin Allograft Utilization By 21 Senior Academic Burn Surgeons, William Hickerson, Franco Aveau, Narayan Iyer, James Jeng, Victor Joe
School of Medicine Faculty Publications
55th Annual Meeting of the American Burn Association, ABA 2023, May 16-19,2023, Dallas, TX
Practical Mouse Model To Investigate Therapeutics For Staphylococcus Aureus Contaminated Surgical Mesh Implants, Madison M. Collins, Brent Race, Ronald J. Messer, Chase Baune, Scott D. Kobayashi, Dan Long, Katie Williams, Aaron M. Hasenkrug, Kim Hasenkrug, Natalia Malachowa
Practical Mouse Model To Investigate Therapeutics For Staphylococcus Aureus Contaminated Surgical Mesh Implants, Madison M. Collins, Brent Race, Ronald J. Messer, Chase Baune, Scott D. Kobayashi, Dan Long, Katie Williams, Aaron M. Hasenkrug, Kim Hasenkrug, Natalia Malachowa
School of Medicine Faculty Publications
Introduction: The use of prosthetic mesh in hernia repair provides a powerful tool to increase repair longevity, decrease recurrence rates, and facilitate complex abdominal wall reconstruction. Overall infection rates with mesh are low, but for those affected there is high morbidity and economic cost. The availability of a practicable small animal model would be advantageous for the preclinical testing of prophylactics, therapeutics, and new biomaterials. To this end, we have developed a novel mouse model for implantation of methicillin-resistant Staphylococcus aureus–infected surgical mesh and provide results from antibiotic and immunotherapeutic testing. Materials and Methods: Implantation of surgical mesh between fascial …