Open Access. Powered by Scholars. Published by Universities.®
- Discipline
-
- Engineering (8)
- Biomedical Engineering and Bioengineering (5)
- Biomedical Devices and Instrumentation (3)
- Diseases (3)
- Cardiology (2)
-
- Cardiovascular Diseases (2)
- Mechanical Engineering (2)
- Medical Specialties (2)
- Other Biomedical Engineering and Bioengineering (2)
- Rehabilitation and Therapy (2)
- Sports Sciences (2)
- Surgical Procedures, Operative (2)
- Alternative and Complementary Medicine (1)
- Anatomy (1)
- Biological Engineering (1)
- Biology and Biomimetic Materials (1)
- Biomechanical Engineering (1)
- Biomedical (1)
- Body Regions (1)
- Electrical and Computer Engineering (1)
- Engineering Science and Materials (1)
- Health and Medical Administration (1)
- Homeopathy (1)
- International Public Health (1)
- Kinesiotherapy (1)
- Manufacturing (1)
- Materials Science and Engineering (1)
- Keyword
-
- 3D printing (1)
- Ablation Therapy (1)
- Angiogenesis (1)
- Atrial Fibrillation (1)
- Ballistic Gel (1)
-
- Bamboo (1)
- Beach (1)
- Bridge II Sports (1)
- Calibrated Cuff Plethysmography (1)
- Cardiovascular Disease (1)
- Catheter (1)
- Cold-Water Immersion (1)
- Composites (1)
- Conductive Gel (1)
- DNA extraction (1)
- Device (1)
- ET (1)
- Endothelial Dysfunction (1)
- Finger (1)
- Glove (1)
- Glucose (1)
- Hand (1)
- Hemp (1)
- Interdisciplinary (1)
- Isotachophoresis (1)
- Lancet (1)
- Left atrial appendage (1)
- Macro Button Toolbar (1)
- Medical (1)
- Microfluidics (1)
- Publication
- Publication Type
Articles 1 - 10 of 10
Full-Text Articles in Equipment and Supplies
Hand Tremor Stabilizer, Krishna Sai Bathini, Ryan Herrmann, Madeleine A. Beaupre
Hand Tremor Stabilizer, Krishna Sai Bathini, Ryan Herrmann, Madeleine A. Beaupre
Biomedical Engineering
The Hand Tremor Stabilizer project represents a significant advancement in assistive device technology, aimed at improving the lives of individuals affected by hand tremors due to conditions such as essential tremor or Parkinson's disease. Throughout the design process, our team engaged in a comprehensive approach that included rapid prototyping, iterative testing, and direct feedback collection from potential users. This process was instrumental in refining the device to meet specific user needs effectively.
Key customer requirements that guided the design of the Hand Tremor Stabilizer included ease of use, portability, washability, accuracy of motion control, comfortable grip, breathability, a natural feel …
Using Noninvasive Calibrated Cuff Plethysmography To Observe The Effects Of Cold-Water Immersion On Arterial Compliance, Rita M. Grigorian
Using Noninvasive Calibrated Cuff Plethysmography To Observe The Effects Of Cold-Water Immersion On Arterial Compliance, Rita M. Grigorian
Biomedical Engineering: Graduate Reports and Projects
As the prevalence of cardiovascular diseases continues to exponentially grow in populations across the globe, the necessity of determining underlying factors, effective methods of diagnoses, and universally available preventive measures also grows. Early detection of endothelial dysfunction, a proven precursor of cardiovascular diseases, can be extremely impactful in encouraging preventative measures and early intervention before medical conditions become chronic. In recent years, ice plunging, a form of cryotherapy involving full body immersion in cold water, has gained popularity within circles of fitness and health practitioners, gaining the interest of people of all backgrounds. Certain parallels observed between the human physiological …
Validation Of Macro Button Toolbar System For Radiology Report Composition, Brennan L. Chow
Validation Of Macro Button Toolbar System For Radiology Report Composition, Brennan L. Chow
College of Engineering Summer Undergraduate Research Program
The macro button toolbar system was developed to enhance radiologist report composition and improve group productivity in response to a rise in imaging volume and an impending radiologist workforce shortage. This research aims to validate the proposed benefits of the macro button toolbar system using an analysis of a time study and the radiology group’s historical wRVU productivity data. The study found that radiologists using this system achieved significantly higher productivity compared to national averages, with high toolbar users experiencing a 29% increase in wRVU productivity and a 52.6% reduction in report completion time for X-ray exams. The reduced report …
3-In-1 Medical Lancet, Jonathan J. Panella, Gage Vogtlin, Marissa Koski, Benjamin Neyland
3-In-1 Medical Lancet, Jonathan J. Panella, Gage Vogtlin, Marissa Koski, Benjamin Neyland
Mechanical Engineering
First responders need a quick, sterile, and convenient way to sample blood for glucose testing because glucose levels are a vital metric in assessing time-critical emergency situations. The blood sampling process consists of pre-sterilizing the sample site on the skin with an alcohol pad, pricking the skin with a lancet, and lastly, after sampling, putting a bandage over the prick site. The scope of this project is to design a device which integrates and streamlines the use of the three sub-processes (sterilization, lancing, and bandaging) while upholding the necessary requirements of a single-use medical device and considering other factors which …
Non-Invasive Peripheral Venous And Arterial Line Air Detector For Embolization Prevention, Alexandria Kwong, Kevin Shu, Dylan Meinster
Non-Invasive Peripheral Venous And Arterial Line Air Detector For Embolization Prevention, Alexandria Kwong, Kevin Shu, Dylan Meinster
Biomedical Engineering
The scope of this project includes designing a non-invasive bubble detector for peripheral venous and arterial lines. For minimally invasive cardiac procedures, arterial and venous access is necessary for these procedures as is constant flow through the tubing to prevent clotting and to administer drugs. Air bubbles are common in these lines and can be consequential if enough air is introduced into the human system. Air embolisms are the most common and relevant issues during these procedures. The goal of this device is to create an attachable detector for air bubbles in saline that can also terminate flow and alert …
Left Atrial Appendage Printing Process, Areli Reyes, Brandon James Mukai, Mia Noelle Von Knorring
Left Atrial Appendage Printing Process, Areli Reyes, Brandon James Mukai, Mia Noelle Von Knorring
Biomedical Engineering
The left atrial appendage senior design team aims to assist in closing off the left atrial appendage that is susceptible to coagulation due to non-valvular atrial fibrillation. Coagulation in the left atrial appendage (LAA) can be life threatening as it can lead to a stroke. Dr. Chris Porterfield performs a procedure that uses the Boston Scientific Watchman to close the appendage. He finds that sizing the Watchman properly is difficult with limited visuals from live CT scans. He proposed converting the CT scans into a 3D printed model of the left atrial appendage and left atrium so he can visually …
Left Atrial Model, Borna Sobati, Sarah Porello, Tess Pate
Left Atrial Model, Borna Sobati, Sarah Porello, Tess Pate
Biomedical Engineering
The objective is to produce an electrophysiological model of an adult human left atrium. This model will be used to test mapping probe catheters used for locating cardiac arrhythmias against current technology used in practice. Dr. Chris Porterfield requested this model and other physicians or probe catheter manufacturers may also use this product in the future. Dr. Porterfield also discussed the possibility of future senior project groups using the model as a bench test for designing new catheter tips. The model will precisely simulate electrical behaviors of the heart in normal as well as arrhythmic conditions. Ideally, the model will …
Low-Cost Strider For Guatemala, Nicole Catherine Cooper, Gonzalo Hernandez, Jared W. Tower
Low-Cost Strider For Guatemala, Nicole Catherine Cooper, Gonzalo Hernandez, Jared W. Tower
Mechanical Engineering
The purpose of this project was to create a strider, a type of standing rehabilitation device, for children in developing countries who have trouble walking and supporting their full body weight. The project was initially brought to us by Cal Poly professor Brian Self, who had visited a clinic in San Marcos and determined that there were children there who had difficulties with walking and were a need for a rehabilitation device. The team discussed the problem with Dr. Self, Matt Robinson (a local San Luis Obispo prosthetist), and Cal Poly physics professor Pete Schwartz, all of whom had visited …
Beach Wheelchair Project, Rory Aronson, Joshua Marcum, Samuel Coyne, Alex Hayes, Alexa Colburn, Max Hessel, Benedikt Strauss, Marvin Rimmele, Marco Pietsch
Beach Wheelchair Project, Rory Aronson, Joshua Marcum, Samuel Coyne, Alex Hayes, Alexa Colburn, Max Hessel, Benedikt Strauss, Marvin Rimmele, Marco Pietsch
Mechanical Engineering
The Beach Wheelchair, Sandcrawler, is a machine intended to help give people with disabilities the full beach experience. The non-profit organization Bridge II Sports sponsored this project, and tasked us with developing the design and fabricating a prototype. This chair has several features including a linkage mechanism that raises and lowers a chair relative to an external frame, hand crank drive with Gates Carbondrive belt and sprockets, buoyant Wheeleez balloon tires, and much more.
Design And Experimental Validation Of Continuous Dna Separation Using Itp-Based Microfluidic Device, Nora C. M. Goscinski, Mary E. Rosa, Elizabeth K. Wheeler, Maxim Shusteff
Design And Experimental Validation Of Continuous Dna Separation Using Itp-Based Microfluidic Device, Nora C. M. Goscinski, Mary E. Rosa, Elizabeth K. Wheeler, Maxim Shusteff
Chemistry and Biochemistry
We have demonstrated a chip-based microfluidic device suitable for rapid and high-throughput DNA separation and purification for downstream analysis. The glass-based device incorporates a transverse free-flow isotachophoresis (tFF-ITP) that overcomes the volume limitations of CE approaches, and allows continuous sample processing in contrast to batch-mode solid-phase extraction (SPE). The device is able to focus DNA at flow rates up to 100 uL/min, and sample conductivity up to 2 mS/cm. Downstream of the chip, 30-40% of DNA from the input sample is recovered as a result of ITP focusing, and preliminary results indicate that this design is able to purify DNA …