Full-Text Articles in Equipment and Supplies

Evaluation Of The Quantitative Accuracy Of A Commercially-Available Positron Emission Mammography Scanner, Adam Springer Aug 2010

Evaluation Of The Quantitative Accuracy Of A Commercially-Available Positron Emission Mammography Scanner, Adam Springer

Dissertations and Theses (Open Access)

Objective: The PEM Flex Solo II (Naviscan, Inc., San Diego, CA) is currently the only commercially-available positron emission mammography (PEM) scanner. This scanner does not apply corrections for count rate effects, attenuation or scatter during image reconstruction, potentially affecting the quantitative accuracy of images. This work measures the overall quantitative accuracy of the PEM Flex system, and determines the contributions of error due to count rate effects, attenuation and scatter.

Materials and Methods: Gelatin phantoms were designed to simulate breasts of different sizes (4 – 12 cm thick) with varying uniform background activity concentration (0.007 – 0.5 μCi/cc), cysts and …


Chronic Inflammatory Responses To Microgel-Based Implant Coatings, Amanda W. Bridges, Rachel E. Whitmire, Neetu Singh, Kellie L. Templeman, Julia E. Babensee, L. Andrew Lyon, Andrés J. García Jan 2010

Chronic Inflammatory Responses To Microgel-Based Implant Coatings, Amanda W. Bridges, Rachel E. Whitmire, Neetu Singh, Kellie L. Templeman, Julia E. Babensee, L. Andrew Lyon, Andrés J. García

Biology, Chemistry, and Environmental Sciences Faculty Articles and Research

Inflammatory responses to implanted biomedical devices elicit a foreign body fibrotic reaction that limits device integration and performance in various biomedical applications. We examined chronic inflammatory responses to microgel conformal coatings consisting of thin films of poly(N-isopropylacrylamide) hydrogel microparticles cross-linked with poly(ethylene glycol) diacrylate deposited on poly(ethylene terephthalate) (PET). Unmodified and microgel-coated PET disks were implanted subcutaneously in rats for 4 weeks and explants were analyzed by histology and immunohistochemistry. Microgel coatings reduced chronic inflammation and resulted in a more mature/organized fibrous capsule. Microgel-coated samples exhibited 22% thinner fibrous capsules that contained 40% fewer cells compared to unmodified PET disks. …


Reduced Acute Inflammatory Responses To Microgel Conformal Coatings, Amanda W. Bridges, Neetu Singh, Kellie L. Burns, Julia E. Babensee, L. Andrew Lyon, Andrés J. García Jan 2008

Reduced Acute Inflammatory Responses To Microgel Conformal Coatings, Amanda W. Bridges, Neetu Singh, Kellie L. Burns, Julia E. Babensee, L. Andrew Lyon, Andrés J. García

Biology, Chemistry, and Environmental Sciences Faculty Articles and Research

Implantation of synthetic materials into the body elicits inflammatory host responses that limit medical device integration and biological performance. This inflammatory cascade involves protein adsorption, leukocyte recruitment and activation, cytokine release, and fibrous encapsulation of the implant. We present a coating strategy based on thin films of poly(N-isopropylacrylamide) hydrogel microparticles (i.e. microgels) cross-linked with poly(ethylene glycol) diacrylate. These particles were grafted onto a clinically relevant polymeric material to generate conformal coatings that significantly reduced in vitro fibrinogen adsorption and primary human monocyte/macrophage adhesion and spreading. These microgel coatings also reduced leukocyte adhesion and expression of pro-inflammatory cytokines (TNF-alpha, IL-1 beta, …


Depth And Size Limits For The Visibility Of Veins Using The Veinviewer Imaging System, Soujanya Ganesh May 2007

Depth And Size Limits For The Visibility Of Veins Using The Veinviewer Imaging System, Soujanya Ganesh

Theses and Dissertations (ETD)

Administration of fluids or medication and blood draw procedures require the nurse or the phlebotomist to access the veins in patients at hospitals or phlebotomy centers. It is important to minimize the discomfort associated with sticking needles in the patient more than once and most often, necessary to find an appropriate vein within few minutes. However, problems involved in accessing veins in pediatric and obese patients make it very difficult to perform a successful stick in a short time. The VeinViewer Imaging System is an infrared imaging device that provides the nurses and phlebotomists a means for locating veins in …


Relationship Of Ventilation Ability And Positioning In Left-Sided Congestive Heart Failure Patients, Nancy E. Carson Mar 1971

Relationship Of Ventilation Ability And Positioning In Left-Sided Congestive Heart Failure Patients, Nancy E. Carson

Loma Linda University Electronic Theses, Dissertations & Projects

Proper positioning is used to relieve dyspnea, edema, and fatigue in congestive heart failure patients. According to the review of literature, improved ventilation as measured by specific lung volumes and lung mechanics occurred with upright positioning in normal persons. The effects of specific changes in lung volumes related to position change in congestive heart failure patients has not been documented in literature, although various recommendations related to positioning are made. This exploratory study was undertaken with nine congestive heart failure patients to see if a relationship existed between degree of head elevation and lung ventilation ability as measured by water-bell …


A Study To Demonstrate The Immediate Destination Of An Embolus Formed In The Lumen Of A Peripheral Venous Catheter, Rosemarie Morikone Emori May 1970

A Study To Demonstrate The Immediate Destination Of An Embolus Formed In The Lumen Of A Peripheral Venous Catheter, Rosemarie Morikone Emori

Loma Linda University Electronic Theses, Dissertations & Projects

This study was designed to show the immediate destination of an embolus formed in the lumen of an intravenous catheter placed in a peripheral vessel. The hypothesis stated that clots injected into a peripheral vessel will lodge in the lungs. A subhypothesis was that the clot may lodge anywhere along the circulatory pathway.

Indications of need for the study as shown by the review of literature were the following: (1) the complications resulting from the frequent use of intravenous polyethylene catheters, (2) experimental studies that showed that clots were formed around intravenous catheters, (3) the evidence that intravenous catheters predispose …