Open Access. Powered by Scholars. Published by Universities.®
- Institution
-
- Rowan University (6)
- Chapman University (3)
- HCA Healthcare (3)
- Old Dominion University (3)
- Thomas Jefferson University (3)
-
- University of Connecticut (2)
- Virginia Commonwealth University (2)
- West Virginia University (2)
- Advocate Health - Midwest (1)
- Boise State University (1)
- Butler University (1)
- Chulalongkorn University (1)
- Jacksonville State University (1)
- James Madison University (1)
- Louisiana State University (1)
- Munster Technological University (1)
- Nova Southeastern University (1)
- Otterbein University (1)
- Purdue University (1)
- Southern Illinois University Edwardsville (1)
- The Lahey Journal (1)
- The Texas Medical Center Library (1)
- The University of San Francisco (1)
- University of Central Florida (1)
- University of Kentucky (1)
- University of Lynchburg (1)
- University of Nevada, Las Vegas (1)
- University of New Hampshire (1)
- University of Rhode Island (1)
- University of Texas Rio Grande Valley (1)
- Keyword
-
- Case Reports (2)
- Fall risk (2)
- Humans (2)
- Machine learning (2)
- Microfluidics (2)
-
- Operating room (2)
- Patient Care Management (2)
- Quality improvement (2)
- 1.6 BIOLOGICAL SCIENCES (1)
- 12-Lead EKG (1)
- 3.3 HEALTH SCIENCES (1)
- 3.4 HEALTH BIOTECHNOLOGY (1)
- 3D Printing (1)
- 80 and over (1)
- APP (1)
- Acoustic (1)
- Acoustic Streaming (1)
- Acute promyelocytic leukemia (1)
- Adult (1)
- Advanced Practice Providers (1)
- Adverse event (1)
- Aged (1)
- Aged, 80 and over (1)
- Agitation (1)
- Airway Management (1)
- Anemia (1)
- Anesthesia (1)
- Angioedema (1)
- Angioedema Protocol/Guideline/Procedure/Policy (1)
- Anterior shoulder instability (1)
- Publication Year
- Publication
-
- Rowan-Virtua Research Day (6)
- Doctor of Nursing Practice Projects (2)
- Graduate Theses, Dissertations, and Problem Reports (ETD) (2)
- Abington Jefferson Health Papers (1)
- BU Well (1)
-
- Biology, Chemistry, and Environmental Sciences Faculty Articles and Research (1)
- Center for Bioelectronics Publications (1)
- Chulalongkorn Medical Journal (1)
- Communication Sciences and Disorders Faculty Articles and Research (1)
- DNP Projects (1)
- Dental Hygiene Student Scholarship (1)
- Department of Biological Sciences Publications (1)
- Department of Medicine Faculty Publications (1)
- Department of Neurosurgery Faculty Papers (1)
- Dissertations and Theses (Open Access) (1)
- Doctor of Nursing Practice Scholarly Projects (1)
- Engineering Technology Faculty Publications (1)
- HCA Healthcare Journal of Medicine (1)
- Honors Scholar Theses (1)
- Honors Theses and Capstones (1)
- Honors Undergraduate Theses (1)
- Internal Medicine (1)
- Journal of Patient-Centered Research and Reviews (1)
- LSU Doctoral Dissertations (1)
- MEDI 9331 Scholarly Activities Clinical Years (1)
- Mako: NSU Undergraduate Student Journal (1)
- Master's Projects and Capstones (1)
- Master's Theses (1)
- North Texas GME Research Forum 2026 (1)
- Physical Therapy Faculty Articles and Research (1)
- Publication Type
Articles 31 - 47 of 47
Full-Text Articles in Equipment and Supplies
Chlorhexidine Gluconate Vs Povidone-Iodine In The Prevention Of Clean-Contaminated Surgical Site Infections, Erin Layne, Abigail Stone
Chlorhexidine Gluconate Vs Povidone-Iodine In The Prevention Of Clean-Contaminated Surgical Site Infections, Erin Layne, Abigail Stone
Physician Assistant Capstones, 2016 to 2019
Abstract
Background:
A patient’s skin is the major source of pathogens that can cause post-operative complications such as surgical site infections (SSIs). Optimization of pre-operative skin antisepsis is obtained with chlorhexidine gluconate (CG) and povidone-iodine (PI). These two solutions are the most widely used antiseptics for pre-operative purposes.
Objective:
Among surgical patients greater than 18 years of age undergoing clean-contaminated surgery, which antiseptic, iodophors or chlorhexidine gluconate, is more effective at reducing postoperative surgical site infections?
Methods:
A search was done in PubMed utilizing the terms chlorhexidine, infection control, iodophors, and surgical site infection. The limits applied included randomized …
Utilizing Simulation To Implement Cognitive Aids In The Operating Room, Kaitlyn Brown
Utilizing Simulation To Implement Cognitive Aids In The Operating Room, Kaitlyn Brown
Doctor of Nursing Practice Projects
Background: Operating room crises require prompt, efficient action to avoid detrimental outcomes. Research shows that crisis checklists or other cognitive aids assist anesthesia providers in taking prompt action while improving efficiency by decreasing treatment steps missed during critical events.
Objectives: The purpose of this project was to evaluate the effectiveness of incorporating cardiac arrest and malignant hyperthermia crisis checklists into the operating room using high-fidelity simulation-based education.
Methods: Researchers implemented the Stanford Emergency Manual Cognitive Aids for cardiac arrest and malignant hyperthermia to anesthesia staff at a community hospital in southern Illinois with 18 participants. Implementation consisted of an education …
Acute Promyelocytic Leukemia: A Case Study Correlating Cytogenetic Abnormality With Prognosis, Alyssa Lamond, Theresa Tellier-Castellone
Acute Promyelocytic Leukemia: A Case Study Correlating Cytogenetic Abnormality With Prognosis, Alyssa Lamond, Theresa Tellier-Castellone
Senior Honors Projects
Advancements in medical technology today have positively impacted the diagnosis, treatment, and prognosis of cancers. Particularly acute promyelocytic leukemia (APL) has completely improved from having the poorest prognosis to one of the best. Acute promyelocytic leukemia is a malignant disease of hematopoietic tissue classified by WHO as leukemia with >20% blasts from the myeloid lineage, specifically promyelocytes. Determined in 1976, FAB classified AML subtypes M1-M7, with APL being M3. Specific characteristics classify the subtype of AML, with each resulting from a different genetic abnormality. The focus of APL diagnosis, treatment, and prognosis occurs around the known PML-RARα fusion gene. Flow …
Seeing Eye To Eye: A Machine Learning Approach To Automated Saccade Analysis, Maigh Attre
Seeing Eye To Eye: A Machine Learning Approach To Automated Saccade Analysis, Maigh Attre
Honors Scholar Theses
Abnormal ocular motility is a common manifestation of many underlying pathologies particularly those that are neurological. Dynamics of saccades, when the eye rapidly changes its point of fixation, have been characterized for many neurological disorders including concussions, traumatic brain injuries (TBI), and Parkinson’s disease. However, widespread saccade analysis for diagnostic and research purposes requires the recognition of certain eye movement parameters. Key information such as velocity and duration must be determined from data based on a wide set of patients’ characteristics that may range in eye shapes and iris, hair and skin pigmentation [36]. Previous work on saccade analysis has …
Rethinking Intravenous Catheter Size And Location For Computed Tomography Pulmonary Angiography, Travis Marshall, Nae Meng Chen, Eric Nguyen, David E. Slattery, Tony Zitek
Rethinking Intravenous Catheter Size And Location For Computed Tomography Pulmonary Angiography, Travis Marshall, Nae Meng Chen, Eric Nguyen, David E. Slattery, Tony Zitek
School of Medicine Faculty Research
Introduction: Computed tomography pulmonary angiography (CTPA) is the test of choice for diagnosis of pulmonary embolism (PE) in the emergency department (ED), but this test may be indeterminate for technical reasons such as inadequate contrast filling of the pulmonary arteries. Many hospitals have requirements for intravenous (IV) catheter size or location for CTPAs to reduce the chances of inadequate filling, but there is a lack of clinical data to support these requirements. The objective of this study was to determine if a certain size or location of IV catheter used for contrast for CTPA is associated with an increased chance …
Direct Quantification Of Deubiquitinating Enzyme Activity In Single Intact Cells, Nora Safabakhsh
Direct Quantification Of Deubiquitinating Enzyme Activity In Single Intact Cells, Nora Safabakhsh
LSU Doctoral Dissertations
Challenges in drug efficacy occur during the treatment of most types of cancer due to the heterogeneity of the tumor microenvironment. This has led to the development of personalized medicine. Due to the clinical success of the proteasome inhibitors Bortezomib and Carfilzomib in treatment of multiple myeloma, interest has shifted towards molecularly-targeted chemotherapeutics for ubiquitin-proteasome system (UPS). Deubiquitinating enzymes (DUBs) are an essential part of this pathway which have been found to promote Bortezomib resistance in multiple myeloma patients. Unfortunately, there is a lack of specific, high throughput biochemical assays to characterize DUB activity in patient samples before and after …
Assessment Of Falls On A Medical-Telemetry Unit, Andie Reed
Assessment Of Falls On A Medical-Telemetry Unit, Andie Reed
Master's Projects and Capstones
The purpose of this quality improvement project aimed at reducing falls on a medical-telemetry unit in a large metropolitan Magnet hospital. It was important for the MSN/CNL students to focus on falls because it is not just a concern for this institution, it is a national dilemma that needs to be addressed. Due to the complexities and intricate details of the IRB process, the MSN/CNL students were unable to collect data or further advance their project into the microsystem. Instead, information was attained from the University of San Francisco database to allow the MSN/CNL students to continue with the steps …
A Novel Hybrid Imaging System To Aid In Surgical Decision Making, Lawrence Yip, Madeleine Van De Kleut, Ivan Kosik, Astrid Chamson-Reig, Jeffrey Jl Carson
A Novel Hybrid Imaging System To Aid In Surgical Decision Making, Lawrence Yip, Madeleine Van De Kleut, Ivan Kosik, Astrid Chamson-Reig, Jeffrey Jl Carson
Western Research Forum
Background:
Breast cancer accounts for 25% of all cancer cases among women. In breast-conserving surgery, a common treatment, the tumour is excised with a healthy tissue margin. However, detection of the margin can be difficult. Current techniques to guide excision are often insufficient, and re-excision can occur up to 25% of the time.
Methods:
Photoacoustic imaging is a hybrid imaging modality that combines the advantages of optical imaging and ultrasound while using safe non-ionizing light. This project involves the development of a novel imaging system with a new scanner design to overcome common limitations and provide images to aid in …
Changing Diagnostic Methods And Increased Detection Of Verotoxigenic Escherichia Coli, Ireland, Thomas Rice, Noreen Quinn, Roy D. Sleator, Brigid Lucey
Changing Diagnostic Methods And Increased Detection Of Verotoxigenic Escherichia Coli, Ireland, Thomas Rice, Noreen Quinn, Roy D. Sleator, Brigid Lucey
Department of Biological Sciences Publications
The recent paradigm shift in infectious disease diagnosis from culture-based to molecular-based approaches is exemplified in the findings of a national study assessing the detection of verotoxigenic Escherichia coli infections in Ireland. The methodologic changes have been accompanied by a dramatic increase in detections of non-O157 verotoxigenic E. coli serotypes.
"What's App?" Utilizing Evidence Based Medicine Apps In The Clinical Setting, Kathryn C. O'Donovan
"What's App?" Utilizing Evidence Based Medicine Apps In The Clinical Setting, Kathryn C. O'Donovan
BU Well
The medical community has utilized evidence-based medicine, or EBM, in practice for decades, and healthcare personnel are used to the idea of utilizing research and statistics to determine the treatment of patients. However, as technology advances, the use of electronics and EBM apps has increased in the clinical setting. While there are advantages to clinicians having resources at their fingertips as they talk with patients, there are also hurdles that could harm or offend patients. So as healthcare inevitably becomes more and more electronic, can providers strike the balance needed to effectively use EBM apps in practice to provide optimum …
The Value Of Contrast Echocardiography, Shannon C. Treiber, Bijoy K. Khandheria
The Value Of Contrast Echocardiography, Shannon C. Treiber, Bijoy K. Khandheria
Journal of Patient-Centered Research and Reviews
Purpose
There is much evidence-based research proving the effectiveness of contrast echocardiography, but there are still questions and concerns about its specific uses. This study tested the effectiveness of contrast echocardiography in defining the left ventricular endocardial border.
Methods
From 30 patients, a total of 60 echocardiograms –– 30 with and 30 without use of contrast –– were retrospectively reviewed by four blinded cardiologists with advanced training in echocardiography. No single cardiologist reviewed contrast and noncontrast images of the same patient. Each set of 30 echocardiograms was then studied for wall-motion scoring. Visualization of left ventricular wall segments and a …
A Non-Invasive Method Of Measuring Respiration While Providing Wireless Power For Rodents With Implantable Devices, Jynx O. Boyne, Daniel J. Pederson, Zhi Wang, Pedro Irazoqui Dr.
A Non-Invasive Method Of Measuring Respiration While Providing Wireless Power For Rodents With Implantable Devices, Jynx O. Boyne, Daniel J. Pederson, Zhi Wang, Pedro Irazoqui Dr.
The Summer Undergraduate Research Fellowship (SURF) Symposium
Respiratory measurements can be used as diagnostic and research tools. Spirometry is the gold standard for gaining these measurements, but is difficult to use in rodents as it requires an invasive procedure. Total Body Plethysmograpy (TBP) is a non-invasive way to measure respiration rates that does not cause stress to the rodent. In this system, the subject is encased in a solid, constant volume chamber with measurements determining the subject’s respiration. When using TBP in medical or research settings, challenges occur in powering devices within the TBP chamber as wires and other recording equipment compromise the airtightness of the chamber. …
Disposable Platform Provides Visual And Color-Based Point-Of-Care Anemia Self-Testing, Erika A. Tyburski, Scott E. Gillespie, William A. Stoy, Robert G. Mannino, Alexander J. Weiss, Alexa F. Siu, Rayford H. Bulloch, Karthik Thota, Anyela Cardenas, Wilena Session, Hanna J. Khoury, Siobhán O'Connor, Silvia T. Bunting, Jeanne Boudreaux, Craig R. Forest, Manila Gaddh, Traci Leong, L. Andrew Lyon, Wilbur A. Lam
Disposable Platform Provides Visual And Color-Based Point-Of-Care Anemia Self-Testing, Erika A. Tyburski, Scott E. Gillespie, William A. Stoy, Robert G. Mannino, Alexander J. Weiss, Alexa F. Siu, Rayford H. Bulloch, Karthik Thota, Anyela Cardenas, Wilena Session, Hanna J. Khoury, Siobhán O'Connor, Silvia T. Bunting, Jeanne Boudreaux, Craig R. Forest, Manila Gaddh, Traci Leong, L. Andrew Lyon, Wilbur A. Lam
Biology, Chemistry, and Environmental Sciences Faculty Articles and Research
Anemia, or low blood hemoglobin (Hgb) levels, afflicts 2 billion people worldwide. Currently, Hgb levels are typically measured from blood samples using hematology analyzers, which are housed in hospitals, clinics, or commercial laboratories and require skilled technicians to operate. A reliable, inexpensive point-of-care (POC) Hgb test would enable cost-effective anemia screening and chronically anemic patients to self-monitor their disease. We present a rapid, standalone, and disposable POC anemia test that, via a single drop of blood, outputs color-based visual results that correlate with Hgb levels.
METHODS. We tested blood from 238 pediatric and adult patients with anemia of varying …
Biomedical Photoacoustic Imaging Using Gas-Coupled Laser Acoustic Detection, Jami Johnson
Biomedical Photoacoustic Imaging Using Gas-Coupled Laser Acoustic Detection, Jami Johnson
Student Research Initiative
Several detection methods have been explored for photoacoustic and ultrasound imaging of biological tissues. Piezoelectric transducers are commonly used, which require contact with the sample to be imaged and have limiting bandwidth characteristics. Interferometry detection exhibits improved bandwidth characteristics and resolution, yet generally require complicated optics and the incorporation of a contacting reflective medium. In this paper, we report the use of a noncontact photoacoustic imaging system that does not require the use of a reflective layer. A simple, robust technique known as gas-coupled laser acoustic detection is used, which has previously been applied to evaluation of composite materials. This …
Investigation Of Emergency Medical Technicians Practice And Beliefs Regarding The Recognition And Treatment Of Exertional Heat Stroke, Kristin Applegate
Investigation Of Emergency Medical Technicians Practice And Beliefs Regarding The Recognition And Treatment Of Exertional Heat Stroke, Kristin Applegate
Master's Theses
Context: Current Evidence Based Practice (EBP) supports the use of rectal thermometry (Tre) for an accurate diagnosis and cold water-immersion (CWI) for the treatment of Exertional Heat Stroke (EHS) for an optimal outcome. Emergency Medical Services (EMS) play a critical role for the diagnosis and treatment of EHS as they may be the first to arrive on scene, however there is limited data regarding their implementation of EBP. Objective: Investigate current practice regarding EHS by EMS professionals and explore the relationship that exists between EMS and Athletic Trainers (ATs). Design: A basic qualitative design using in-person focus groups. …
Evaluation Of The Quantitative Accuracy Of A Commercially-Available Positron Emission Mammography Scanner, Adam Springer
Evaluation Of The Quantitative Accuracy Of A Commercially-Available Positron Emission Mammography Scanner, Adam Springer
Dissertations and Theses (Open Access)
Objective: The PEM Flex Solo II (Naviscan, Inc., San Diego, CA) is currently the only commercially-available positron emission mammography (PEM) scanner. This scanner does not apply corrections for count rate effects, attenuation or scatter during image reconstruction, potentially affecting the quantitative accuracy of images. This work measures the overall quantitative accuracy of the PEM Flex system, and determines the contributions of error due to count rate effects, attenuation and scatter.
Materials and Methods: Gelatin phantoms were designed to simulate breasts of different sizes (4 – 12 cm thick) with varying uniform background activity concentration (0.007 – 0.5 μCi/cc), cysts and …
The Effectiveness Of Shoulder Injury Assessment Techniques: Analyzing The Occurrences Of False Positives, Alec Cianfichi
The Effectiveness Of Shoulder Injury Assessment Techniques: Analyzing The Occurrences Of False Positives, Alec Cianfichi
Undergraduate Theses and Capstone Projects
Shoulder injuries are very common in sports such as baseball, football, and tennis due to high impact and stress placed on the shoulder joint. Due to the greater chance of shoulder injuries in these types of sports, it is imperative for shoulder injury assessments to be accurate in order to ensure that the athlete does not participate with an injured shoulder or lose participation time due to an incorrect assessment. In order to assess the validity of the Apprehension, Relocation, and Surprise test for shoulder instability, student athletes with no known shoulder injuries were evaluated. Tests were conducted under the …