Open Access. Powered by Scholars. Published by Universities.®

Anatomy

Institution
Keyword
Publication Year
Publication
Publication Type

Articles 31 - 37 of 37

Full-Text Articles in Equipment and Supplies

Effects Of Revision Surgery On Grade Of Adverse Local Tissue Reaction Following Recall Of A Modular Hip Implant, Joseph F. Davies, Danielle M. Greer, Susan Truchan Nov 2017

Effects Of Revision Surgery On Grade Of Adverse Local Tissue Reaction Following Recall Of A Modular Hip Implant, Joseph F. Davies, Danielle M. Greer, Susan Truchan

Journal of Patient-Centered Research and Reviews

Background: The Stryker Rejuvenate modular hip implant device allows for greater versatility in matching a patient’s anatomy than conventional implants. Device recalls and in vivo metal hypersensitivity after total hip arthroplasty (THA) are common. However, recall of the Rejuvenate implant represents one of the largest recall volumes to date, highlighting our uncertainty regarding causes of device metal fretting/corrosion and adverse local tissue reaction (ALTR). While devices with metal-on-metal bearings historically were culprits for release of metal debris, more recently developed modular-neck devices add opportunity for adjacent metal components to rub together. With the Rejuvenate device, corrosion or fretting likely occurs …


The Motor Cortical Representation Of A Muscle Is Not Homogeneous In Brain Connectivity, Jo Armour Smith, Alaa Albishi, Sarine Babikian, Skulpan Asavasopon, Beth E. Fisher, Jason Kutch Jun 2017

The Motor Cortical Representation Of A Muscle Is Not Homogeneous In Brain Connectivity, Jo Armour Smith, Alaa Albishi, Sarine Babikian, Skulpan Asavasopon, Beth E. Fisher, Jason Kutch

Physical Therapy Faculty Articles and Research

Functional connectivity patterns of the motor cortical representational area of single muscles have not been extensively mapped in humans, particularly for the axial musculature. Functional connectivity may provide a neural substrate for adaptation of muscle activity in axial muscles that have both voluntary and postural functions. The purpose of this study was to combine brain stimulation and neuroimaging to both map the cortical representation of the external oblique (EO) in primary motor cortex (M1) and supplementary motor area (SMA), and to establish the resting-state functional connectivity associated with this representation. Motor evoked potentials were elicited from the EO muscle in …


Reliability Of Clinical Evaluators Of Spasticity In Patients With Stroke, Tiffany Alvino, Shiney David, Chelsea Gendvil Jun 2016

Reliability Of Clinical Evaluators Of Spasticity In Patients With Stroke, Tiffany Alvino, Shiney David, Chelsea Gendvil

Dissertations, Theses, and Capstone Projects

Spasticity is characterized by hyperexcitable stretch reflexes with amplitude increases in response to velocity dependent passive movement and resistance. Spasticity is the result of abnormal function of segmental and suprasegmental neuronal circuits. The objective of this study was to determine any positive correlation between three clinical evaluators of spasticity (i.e., the pendulum test, the patellar tendon tap test (PTT), and the Modified Ashworth scale) in their reliability to assess spasticity in people post-stroke. It was hypothesized that the use of force movement sensors along with surface electromyography increases the reliability of the standardized clinical tests. The results show that all …


Lead Burden As A Factor For Higher Complication Rate In Patients With Implantable Cardiac Devices, Christopher Kolibash, Naoyo Mori, Jasbir Sra, Masood Akhtar, M. Eyman Mortada Jan 2015

Lead Burden As A Factor For Higher Complication Rate In Patients With Implantable Cardiac Devices, Christopher Kolibash, Naoyo Mori, Jasbir Sra, Masood Akhtar, M. Eyman Mortada

Journal of Patient-Centered Research and Reviews

Purpose

Lead revisions have increased over the last decade. Patients who do not undergo lead extraction face an increased lead burden. Consequences of increased lead burden have not been fully defined. We sought to characterize the complication rate and outcomes in patients with sterile redundant leads.

Methods

We retrospectively reviewed 242 consecutive patients [mean age 74 ± 12 years; 66.9% male] who underwent lead revision that resulted in an abandoned lead from January 2005 to June 2010. Patients were placed in a cohort based on number of leads after last recorded procedure (Group A: ≤2 [n=58]; Group B: 3-4 [n=168]; …


Disposable Platform Provides Visual And Color-Based Point-Of-Care Anemia Self-Testing, Erika A. Tyburski, Scott E. Gillespie, William A. Stoy, Robert G. Mannino, Alexander J. Weiss, Alexa F. Siu, Rayford H. Bulloch, Karthik Thota, Anyela Cardenas, Wilena Session, Hanna J. Khoury, Siobhán O'Connor, Silvia T. Bunting, Jeanne Boudreaux, Craig R. Forest, Manila Gaddh, Traci Leong, L. Andrew Lyon, Wilbur A. Lam Jan 2014

Disposable Platform Provides Visual And Color-Based Point-Of-Care Anemia Self-Testing, Erika A. Tyburski, Scott E. Gillespie, William A. Stoy, Robert G. Mannino, Alexander J. Weiss, Alexa F. Siu, Rayford H. Bulloch, Karthik Thota, Anyela Cardenas, Wilena Session, Hanna J. Khoury, Siobhán O'Connor, Silvia T. Bunting, Jeanne Boudreaux, Craig R. Forest, Manila Gaddh, Traci Leong, L. Andrew Lyon, Wilbur A. Lam

Biology, Chemistry, and Environmental Sciences Faculty Articles and Research

Anemia, or low blood hemoglobin (Hgb) levels, afflicts 2 billion people worldwide. Currently, Hgb levels are typically measured from blood samples using hematology analyzers, which are housed in hospitals, clinics, or commercial laboratories and require skilled technicians to operate. A reliable, inexpensive point-of-care (POC) Hgb test would enable cost-effective anemia screening and chronically anemic patients to self-monitor their disease. We present a rapid, standalone, and disposable POC anemia test that, via a single drop of blood, outputs color-based visual results that correlate with Hgb levels.

METHODS. We tested blood from 238 pediatric and adult patients with anemia of varying …


Digital And Clinical Refractometers Are Valid Instruments For The Measure Of Hydration Status, A. J. Niemann, S. W. Yeargin, L. E. Eberman, H. M. Mata, H. A. Adams, D. J. Dziedzicki May 2012

Digital And Clinical Refractometers Are Valid Instruments For The Measure Of Hydration Status, A. J. Niemann, S. W. Yeargin, L. E. Eberman, H. M. Mata, H. A. Adams, D. J. Dziedzicki

Symposium 2012

Although some instruments have been validated for clinical measure of hydration status, new and currently invalid instruments are available for purchase and clinical use. Athletic trainers commonly use these instruments to assess hydration status for weight checks and body mass loss charts due to their ease of use. However, the validity of these popular instruments has not yet been established.


Kinesiology Of Knee Flexion Deformity Using Electromyography, Paul J. Roby Mar 1973

Kinesiology Of Knee Flexion Deformity Using Electromyography, Paul J. Roby

Loma Linda University Electronic Theses, Dissertations & Projects

A kinesiological electromyographic study was completed to determine the relative changes in muscle activity as a person walks and stands with different degrees of knee flexion deformity. The ultimate aim was to establish criteria for appropriate preventive and corrective measures relating to knee flexion deformity.

Six different muscles were implanted with wire electrodes. The subjects performed a series of walking and standing experiments with the knee flexed at selected angles by a locking leg brace to simulate knee flexion deformity. The electromyographic action potentials were monitored by analog tapes, oscilloscopes and closed circuit television. The analog tapes were displayed on …