Open Access. Powered by Scholars. Published by Universities.®

Biomechanics Commons

Open Access. Powered by Scholars. Published by Universities.®

Mechanical Engineering

Institution
Keyword
Publication Year
Publication
Publication Type
File Type

Articles 31 - 60 of 85

Full-Text Articles in Biomechanics

Broadening The Capability Of Kinetics Analysis In Biomechanics, Nicholas Nelson Jan 2021

Broadening The Capability Of Kinetics Analysis In Biomechanics, Nicholas Nelson

Electronic Theses and Dissertations

Two studies are discussed in this manuscript each preceded by a literature review of the topic. The first review and study explore agility movements and the effect that alternative upper designs in shoes might have on ground reaction force measures of performance. The second review and study evaluate methods of predicting ground reaction forces without the use of a force platform. A method of using effective forces and ways of improving its accuracy are evaluated in depth.


Swimming Of Pelagic Snails: Kinematics And Fluid Dynamics, Ferhat Karakas Oct 2020

Swimming Of Pelagic Snails: Kinematics And Fluid Dynamics, Ferhat Karakas

USF Tampa Graduate Theses and Dissertations

Pteropods (also known as sea butterflies or sea angels), are holoplanktonic marine snails which swim by flapping a pair of extremely flexible wings. The wings are modified from the molluscan foot and the wing motions are supported by the fluid pressure without any rigid support. Sea angels (gymnosome pteropods) are completely naked; in contrast, sea butterflies (thecosome pteropods) have negatively buoyant aragonite shells which vary in geometry and size among different species. Pteropods are seasonally abundant in the ocean, and an important food source for the other zooplanktons, fishes, and whales. Though studies have been conducted regarding their biology, ecology, …


Atv Dynamics And Pediatric Rider Safety, James T. Auxier Ii Jan 2020

Atv Dynamics And Pediatric Rider Safety, James T. Auxier Ii

Theses and Dissertations--Biomedical Engineering

It has been observed through numerous academic and governmental agency studies that pediatric all-terrain vehicle ridership carries significant risk of injury and death. While no doubt valuable to safety, the post-hoc approach employed in these studies does little to explain the why and how behind the risk factors. Furthermore, there has been no prolonged, widespread, organized, and concerted effort to reconstruct and catalog the details and causes of the large (20,000+) number of ATV-related injuries that occur each year as has been done for road-based motor vehicle accidents. This dissertation takes the opposite approach from a meta-analysis and instead examines …


Tracking Center Of Mass With Limited Inertial Measurement Units, Connor Nathaniel Morrow Sep 2019

Tracking Center Of Mass With Limited Inertial Measurement Units, Connor Nathaniel Morrow

Dissertations and Theses

Wearable motion tracking systems pose an opportunity to study and correct human balance and posture during movement. Currently, these observations are either being conducted in laboratories with the use of camera systems and markers placed on the body, or through the use of suits containing large numbers (15-20) of inertial measurement units. However, to aid with rehabilitation of individuals with impaired balance, there needs to be an option to collect these observations outside of clinics and without incurring much cost from the user. I have focused on three inertial measurement units, one placed on each shank and one placed on …


Development And Application Of New Methods For Magnetic Resonance Elastography Of The Brain, Charlotte Anne Guertler Aug 2019

Development And Application Of New Methods For Magnetic Resonance Elastography Of The Brain, Charlotte Anne Guertler

McKelvey School of Engineering Graduate Student Theses & Dissertations

Accurate mechanical properties of the intact, living brain are essential for modeling traumatic brain injury (TBI). However, the properties of brain tissue in vivo have traditionally been measured in ex vivo samples. Magnetic resonance elastography (MRE) can be used to measure motion and estimate material properties of soft tissues in vivo, but MRE typically assumes tissue isotropy and homogeneity. The objective of this thesis is to improve MRE of soft tissue, like the brain, by developing and evaluating methods for in vivo estimation of heterogeneous, anisotropic properties. This was achieved through pursuit of the following aims: (1) quantifying the differences …


Estimation Of Arterial Wall Parameters Via Model-Based Analysis Of Noninvasively Measured Arterial Pulse Signals, Dan Wang Apr 2019

Estimation Of Arterial Wall Parameters Via Model-Based Analysis Of Noninvasively Measured Arterial Pulse Signals, Dan Wang

Mechanical & Aerospace Engineering Theses & Dissertations

This dissertation presents a model-based method for estimating arterial wall parameters from noninvasively measured arterial pulse signals via a microfluidic-based tactile sensor. The sensor entails a polydimethylsiloxane (PDMS) microstructure embedded with 5×1 transducer array built on Pyrex/Polyethylene terephthalate (PET) substrate. The arterial pulse causes a time-varying deflection on the top of the PDMS microstructure, which registers as a resistance change by the transducer at the site of the artery.

Owing to the time-harmonic nature of its radial motion, the arterial wall is modeled as a second-order dynamic system. By combining this dynamic model with a hemodynamic model of blood flow, …


Design And Testing Of A Passive Prosthetic Ankle Foot Optimized To Mimic An Able-Bodied Gait, Millicent Schlafly Jun 2018

Design And Testing Of A Passive Prosthetic Ankle Foot Optimized To Mimic An Able-Bodied Gait, Millicent Schlafly

USF Tampa Graduate Theses and Dissertations

Currently there are nearly 2 million people living with limb loss in the United States [1]. Many of these individuals are either transtibial (below knee) or transfemoral (above knee) amputees and require an ankle-foot prosthesis for basic mobility. While there are an abundance of options available for individuals who require an ankle-foot prosthesis, these options fail to mimic an intact ankle when it comes to key evaluation criteria such as range of motion, push-off force, and roll over shape. The roll over shape is created by plotting the center of pressure during a step in a shank-based coordinate system. To …


Biomimetic Design And Construction Of A Bipedal Walking Robot, Alexander Gabriel Steele Jun 2018

Biomimetic Design And Construction Of A Bipedal Walking Robot, Alexander Gabriel Steele

Dissertations and Theses

Human balance and locomotion control is highly complex and not well understood. To understand how the nervous system controls balance and locomotion works, we test how the body responds to controlled perturbations, the results are analyzed, and control models are developed. However, to recreate this system of control there is a need for a robot with human-like kinematics. Unfortunately, such a robotic testbed does not exist despite the numerous applications such a design would have in mobile robotics, healthcare, and prosthetics.

This thesis presents a robotic testbed model of human lower legs. By using MRI and CT scans, I designed …


Exploring The Use Of 3d Scanning To Determine Whole-Body Volume While Wearing A Triathlon Wetsuit, Leland Barker, Diego Medoza, John A. Mercer Apr 2018

Exploring The Use Of 3d Scanning To Determine Whole-Body Volume While Wearing A Triathlon Wetsuit, Leland Barker, Diego Medoza, John A. Mercer

Kinesiology and Nutrition Sciences Faculty Research

Background: Commercial 3 Dimension (3D) scanners are relatively new to anthropometry. The purpose of this study was to explore ability of using a 3D imaging instrument to measure body volume with and without wearing a wetsuit. Three experiments were conducted to achieve this purpose: (1) to determine if the 3D imaging instrument could accurately measure volume of static objects; (2) to determine the resolution of accuracy of measuring volume of static objects; and (3) to compare whole-body volume of wearing a wetsuit using 3D imaging as well as another body volume measure (air displacement technique). Methods: Three experiments were performed: …


Developing Motion Platform Dynamics For Studying Biomechanical Responses During Exercise For Human Spaceflight Applications, Kaitlin Lostroscio Mar 2018

Developing Motion Platform Dynamics For Studying Biomechanical Responses During Exercise For Human Spaceflight Applications, Kaitlin Lostroscio

USF Tampa Graduate Theses and Dissertations

In future human spaceflight missions, with prolonged exposure to microgravity, resistive and aerobic exercises will be countermeasures for bone loss, muscle loss, and decreased aerobic capacity. Two of the exercises of interest are squats and rowing. The cyclic forces produced during these exercises are at relatively low frequencies which are likely to excite structural resonances of space vehicles. Vibration Isolation Systems (VIS) are being designed to be paired with future exploration exercise devices in order to prevent these cyclic exercise forces from impacting the space vehicle. The VIS may be configured such that a platform supports the human and exercise …


Characterizing Anisotropy In Fibrous Soft Materials By Mr Elastography Of Slow And Fast Shear Waves, John Larson Schmidt Dec 2017

Characterizing Anisotropy In Fibrous Soft Materials By Mr Elastography Of Slow And Fast Shear Waves, John Larson Schmidt

McKelvey School of Engineering Graduate Student Theses & Dissertations

The general objective of this work was to develop experimental methods based on magnetic resonance elastography (MRE) to characterize fibrous soft materials. Mathematical models of tissue biomechanics capable of predicting injury, such as traumatic brain injury (TBI), are of great interest and potential. However, the accuracy of predictions from such models depends on accuracy of the underlying material parameters. This dissertation describes work toward three aims. First, experimental methods were designed to characterize fibrous materials based on a transversely isotropic material model. Second, these methods are applied to characterize the anisotropic properties of white matter brain tissue ex vivo. Third, …


Rehabilitating Asymmetric Gait Using Asymmetry, Tyagi Ramakrishnan Nov 2017

Rehabilitating Asymmetric Gait Using Asymmetry, Tyagi Ramakrishnan

USF Tampa Graduate Theses and Dissertations

Human gait is a complex process that involves the coordination of the central nervous and muscular systems. A disruption to the either system results in the impairment of a person’s ability to walk. Impairments can be caused by neurological disorders such as stroke and physical conditions like amputation. There is not a standardized method to quantitatively assess the gait asymmetry of affected subjects. The purpose of this research is to understand the fundamental aspects of asymmetrical effects on the human body and improve rehabilitation techniques and devices. This research takes an interdisciplinary approach to address the limitations with current rehabilitation …


Optimization Of Prosthetic Hands: Utilizing Modularity To Improve Grip Force, Grasp, And Versatility, Jordan William Harris Aug 2017

Optimization Of Prosthetic Hands: Utilizing Modularity To Improve Grip Force, Grasp, And Versatility, Jordan William Harris

UNLV Theses, Dissertations, Professional Papers, and Capstones

It has been demonstrated that although many varieties of upper limb prosthetics exist, commercially available prosthetics are outdated and unsatisfactory. Ineffectiveness and limitations have led to some prosthesis wearers having to own multiple devices, whereas others have given up on them entirely. Even though ample research has been conducted to design and test new hand designs, the industry appears to rest in an overall stagnated state.

It was proposed here, that one problem with prosthetic research is an excess of variables involved in testing, and therefore the improper application of the scientific method. It seems that each time a research …


Biomechanics Of Concussion: The Importance Of Neck Tension, Ron Jadischke Jan 2017

Biomechanics Of Concussion: The Importance Of Neck Tension, Ron Jadischke

Wayne State University Dissertations

Linear and angular velocity and acceleration of the head are typically correlated to concussion. Despite improvements in helmet performance to reduce accelerations, a corresponding reduction in the incidence of concussion has not occurred (National Football League [NFL] 1996 – present).

There is compelling research that forces on and deformation to the brain stem are related to concussion. The brain stem is the center of control for respiration, blood pressure and heart rate and is the root of most cranial nerves. Injury to the brain stem is consistent with most symptoms of concussion reported in the National Football League and the …


Development Of A Finite Element Pelvis And Lower Extremity Model With Growth Plates For Pediatric Pedestrian Protection, Ming Shen Jan 2017

Development Of A Finite Element Pelvis And Lower Extremity Model With Growth Plates For Pediatric Pedestrian Protection, Ming Shen

Wayne State University Dissertations

Finite element (FE) model is a useful tool frequently used for investigating the injury mechanisms and designing protection countermeasures. At present, no 10 years old (YO) pedestrian FE model has been developed from appropriate anthropometries and validated against limitedly available impact response data. A 10 YO child FE pelvis and lower extremities (PLEX) model was established to fill the gap of lacking such models in this age group. The baseline model was validated against available pediatric postmortem human subjects (PMHS) test data and additional scaled adult data, then the PLEX model was integrated to build a whole-body FE model representing …


Effect Of Local Magnetic Field Disturbances On Inertial Measurement Units Accuracy, Xavier Robert-Lachaine, Hakim Mecheri, Christian Larue, André Plamondon Jan 2017

Effect Of Local Magnetic Field Disturbances On Inertial Measurement Units Accuracy, Xavier Robert-Lachaine, Hakim Mecheri, Christian Larue, André Plamondon

Études primaires

Inertial measurement units (IMUs), a practical motion analysis technology for field acquisition, have magnetometers to improve segment orientation estimation. However, sensitivity to magnetic disturbances can affect their accuracy. The objective of this study was to determine the joint angles accuracy of IMUs under different timing of magnetic disturbances of various durations and to evaluate a few correction methods. Kinematics from 12 individuals were obtained simultaneously with an Xsens system where an Optotrak cluster acting as the reference system was affixed to each IMU. A handling task was executed under normal laboratory conditions and imposed magnetic disturbances. Joint angle RMSE was …


A Framework For Studying Meshfree Geometry And A Method For Explicit Boundary Determination, Joseph Bradley Alford Nov 2016

A Framework For Studying Meshfree Geometry And A Method For Explicit Boundary Determination, Joseph Bradley Alford

USF Tampa Graduate Theses and Dissertations

Patient-specific biomechanical analysis is an important tool used to understand the complex processes that occur in the body due to physical stimulation. Patient-specific models are generated by processing medical images; once an object from the image is identified via segmentation, a point cloud representation of the object is extracted. Generating an analysis suitable representation from the point cloud has traditionally required generating a finite element mesh, which often requires a well defined surface to accomplish. Point clouds lack a well defined geometry, meaning that the surface definition is incomplete at best. Point clouds that have been generated from images have …


Molybdenum Disulfide-Conducting Polymer Composite Structures For Electrochemical Biosensor Applications, Hongxiang Jia Nov 2016

Molybdenum Disulfide-Conducting Polymer Composite Structures For Electrochemical Biosensor Applications, Hongxiang Jia

USF Tampa Graduate Theses and Dissertations

Lactic acid is widely existing in human bodies, animals and microorganisms. Recently, using biosensor to detect the concentration of lactic acid and diagnose disease have attracted great research and development interests. Nanocomposites is one of the best material used for biosensor because their wonderful conductivity, optical and electrochemical properties. In the study, MoS2 and polypyrrole (PPY) are used for the composite material electrode. To determine whether lactate oxidase (LOD) was helpful for the biosensor’s detective properties, both PPY-MoS2 film with LOD and PPY-MoS2 film without LOD are being tested. The fourier transform infrared spectroscopy (FTIR) and Raman …


The Development Of A Prosthetic Training Software For Upper Limb Amputees, Tyler Kayne Sullins Jun 2016

The Development Of A Prosthetic Training Software For Upper Limb Amputees, Tyler Kayne Sullins

USF Tampa Graduate Theses and Dissertations

The purpose of this study was to develop an intuitive software that aids in the field of prosthetic training and rehabilitation by creating an individualized visualization of joint angles. This software is titled “the prosthetic training software (PTS) for individualized joint angle representation”, and it enables the individualized portrayal of predicted or pre-recorded joint angles. The PTS is an intuitive program for clinicians and prosthesis users that produces an animation of a virtual avatar reflecting the user’s segment lengths and amputation for rehabilitation and training purposes.

The PTS consists of a graphical user interface (GUI) and a 3D visualization of …


Prosthetic Socket Cooling System, Benjamin K. Kraw, Kathy Ha, Derek Piastrelli, Cuong Lai Jun 2016

Prosthetic Socket Cooling System, Benjamin K. Kraw, Kathy Ha, Derek Piastrelli, Cuong Lai

Mechanical Engineering

A team of four senior-level undergraduate students in the Interdisciplinary Senior Project Design course in the Engineering Department of California Polytechnic State University: San Luis Obispo have worked to develop a prosthetic socket cooling system, namely for veteran Taylor Morris and exclusively for a transfemoral prosthetic socket, under the Quality of Life+ Laboratory. This cooling system will utilize the thermoelectric effect known as the Peltier effect to transmit heat generated from the residual limb to the surrounding environment by means of forced convection over small aluminum heat sinks. Two measurement devices have also been developed to, one, measure the heat …


Physical Testing Of Potential Football Helmet Design Enhancements, Michael Jeremy Schuster Jun 2016

Physical Testing Of Potential Football Helmet Design Enhancements, Michael Jeremy Schuster

Master's Theses

Football is a much loved sport in the United States. Unfortunately, it is also hard on the players and puts them at very high risk of concussion. To combat this an inventor in Santa Barbara brought a new design to Cal Poly to be tested.

The design was tested in small scale first in order to make some preliminary conclusions about the design. In order to fully test the helmet design; however, full scale testing was required. In order to carry out this testing a drop tower was built based on National Operating Committee on Standards for Athletic Equipment, NOCSAE, …


Development Of An Elderly Female Torso Finite Element Model For Restraint System Research And Development Applications, Anil Kalra Kalra Jan 2016

Development Of An Elderly Female Torso Finite Element Model For Restraint System Research And Development Applications, Anil Kalra Kalra

Wayne State University Dissertations

Elderly females are found to be one of the most vulnerable segments of population during motor vehicle crashes and their population is increasing in the coming decades. Current design of restraint systems as well as other passive safety measures are designed based on anthropomorphic details of younger population. Developing another dummy representing elderly female population is a costly effort, while a finite element (FE) model of elderly female with similar anthropomorphic details and age- and gender-specific material properties can be a better alternative solution. The current research focuses on the development of a FE model of an elderly female torso, …


Biomechanical Investigation Of Elite Place-Kicking, Chase M. Pfeifer Nov 2015

Biomechanical Investigation Of Elite Place-Kicking, Chase M. Pfeifer

Department of Mechanical and Materials Engineering: Dissertations, Theses, and Student Research

Many studies aim to understand the fundamentals of kicking commonly displayed by soccer players [4,6,10,16,17,18,24,25,28,29,30,34,36,38,40]. Of those studies, most are limited to a two-dimensional (2D) analysis using high-speed cameras for position tracking or utilizing electromyography to observe the activity of select muscles [4,6,18,25,29,36]. The few studies that investigate kicking using a three-dimensional (3D) model are limited in their position tracking capabilities and focus mainly on joint flexion potentials and foot speed.

This dissertation is a comprehensive biomechanical analysis (kinematic and EMG) of the field-goal place-kicking techniques of four elite kickers in American football. Data were compared and contrasted with ball …


Synergy-Based Two-Level Optimization For Predicting Knee Contact Forces During Walking, Gil Serrancolí, Allison Kinney, Josep M. Font-Llagunes, Benjamin J. Fregly Jul 2015

Synergy-Based Two-Level Optimization For Predicting Knee Contact Forces During Walking, Gil Serrancolí, Allison Kinney, Josep M. Font-Llagunes, Benjamin J. Fregly

Mechanical and Aerospace Engineering Faculty Publications

Musculoskeletal models and optimization methods are combined to calculate muscle forces. Some model parameters cannot be experimentally measured due to the invasiveness, such as the muscle moment arms or the muscle and tendon lengths. Moreover, other parameters used in the optimization, such as the muscle synergy components, can be also unknown. The estimation of all these parameters needs to be validated to obtain physiologically consistent results. In this study, a two-step optimization problem was formulated to predict both muscle and knee contact forces of a subject wearing an instrumented knee prosthesis. In the outer level, muscle parameters were calibrated, whereas …


Development Of A Muscle Model Parameter Calibration Method Via Passive Muscle Force Minimization, Allison Kinney, Benjamin J. Fregly Jul 2015

Development Of A Muscle Model Parameter Calibration Method Via Passive Muscle Force Minimization, Allison Kinney, Benjamin J. Fregly

Mechanical and Aerospace Engineering Faculty Publications

Computational predictions of subject-specific muscle and knee joint contact forces during walking may improve individual rehabilitation treatment design. Such predictions depend directly on specified model parameter values. However, model parameters are difficult to measure non-invasively. Methods for muscle model parameter calibration have been developed previously. However, it is currently unknown how the musculoskeletal system chooses muscle model parameter values. Previous studies have hypothesized that muscles avoid injury during walking by generating little passive force and operating in the ascending region of the force-length curve. This hypothesis suggests that muscle model parameter values may be selected by the body to minimize …


The Influence Of Neuromusculoskeletal Model Calibration Method On Predicted Knee Contact Forces During Walking, Gil Serrancolí, Allison Kinney, Benjamin J. Fregly, Josep M. Font-Llagunes Jun 2015

The Influence Of Neuromusculoskeletal Model Calibration Method On Predicted Knee Contact Forces During Walking, Gil Serrancolí, Allison Kinney, Benjamin J. Fregly, Josep M. Font-Llagunes

Mechanical and Aerospace Engineering Faculty Publications

This study explored the influence of three model calibration methods on predicted knee contact and leg muscle forces during walking. Static optimization was used to calculate muscle activations for all three methods. Approach A used muscle-tendon model parameter values (i.e., optimal muscle fiber lengths and tendon slack lengths) taken directly from literature. Approach B used a simple algorithm to calibrate muscle-tendon model parameter values such that each muscle operated within the ascending region of its normalized force-length curve. Approach C used a novel two-level optimization procedure to calibrate muscle-tendon, moment arm, and neural control model parameter values while simultaneously predicting …


Manipulating The Mass Distribution Of A Golf Putter, Paul J. Hessler Jr. May 2015

Manipulating The Mass Distribution Of A Golf Putter, Paul J. Hessler Jr.

Senior Honors Projects

Putting may appear to be the easiest but is actually the most technically challenging part of the game of golf. The ideal putting stroke will remain parallel to its desired trajectory both in the reverse and forward direction when the putter head is within six inches of the ball. Deviation from this concept will cause a cut or sidespin on the ball that will affect the path the ball will travel.

Club design plays a large part in how well a player will be able to achieve a straight back and straight through club head path near impact; specifically the …


Estimation Of Outer-Middle Ear Transmission Using Dpoaes And Fractional-Order Modeling Of Human Middle Ear, Maryam Naghibolhosseini Feb 2015

Estimation Of Outer-Middle Ear Transmission Using Dpoaes And Fractional-Order Modeling Of Human Middle Ear, Maryam Naghibolhosseini

Dissertations, Theses, and Capstone Projects

Our ability to hear depends primarily on sound waves traveling through the outer and middle ear toward the inner ear. Hence, the characteristics of the outer and middle ear affect sound transmission to/from the inner ear. The role of the middle and outer ear in sound transmission is particularly important for otoacoustic emissions (OAEs), which are sound signals generated in a healthy cochlea, and recorded by a sensitive microphone placed in the ear canal. OAEs are used to evaluate the health and function of the cochlea; however, they are also affected by outer and middle ear characteristics. To …


A Multi-Directional Treadmill Training Program For Improving Gait, Balance, And Mobility In Individuals With Parkinson’S Disease: A Case Series, Kimberly Smith, Kurt Jackson, Kimberly Edginton Bigelow, Lloyd L. Laubach Jan 2015

A Multi-Directional Treadmill Training Program For Improving Gait, Balance, And Mobility In Individuals With Parkinson’S Disease: A Case Series, Kimberly Smith, Kurt Jackson, Kimberly Edginton Bigelow, Lloyd L. Laubach

Mechanical and Aerospace Engineering Faculty Publications

Treadmill training is a commonly used intervention for improving gait in people with Parkinson’s disease (PD). However, little is known about how treadmill training may also influence balance and other aspects of mobility.

The purpose of this case series was to explore the feasibility and possible benefits of multi-directional treadmill training for individuals with PD. Four participants (62.3 ± 6.5 yrs, Hoehn & Yahr 2-4) performed 8 weeks of treadmill training 3 times per week. Weeks 1-4 included forward walking only, while weeks 5-8 included forward and multi-directional walking. Participants were tested every 4 weeks on 4 separate occasions. Outcome …


How Sensitive Is The Deltoid Moment Arm To Joint Center Changes With Rtsa?, David Walker, Allison Kinney, Aimee Struk, Benjamin J. Fregly, Thomas Wright, Scott Banks Sep 2014

How Sensitive Is The Deltoid Moment Arm To Joint Center Changes With Rtsa?, David Walker, Allison Kinney, Aimee Struk, Benjamin J. Fregly, Thomas Wright, Scott Banks

Mechanical and Aerospace Engineering Faculty Publications

The goal of this study was to assess the sensitivity of the deltoid muscle moment arms as a function of joint configuration for an existing RTSA subject. High variations were found for all three deltoid components. Variation over the entire abduction arc was greatest in the anterior and lateral deltoid, while the posterior deltoid moment arm was mostly sensitive to joint center changes early in the abduction arc. Moment arm changes of 10-16mm represent a significant amount of the total deltoid moment arm. This means there is an opportunity to dramatically change the deltoid moments arms through surgical placement of …