Open Access. Powered by Scholars. Published by Universities.®
- Institution
-
- University of Dayton (17)
- Wayne State University (12)
- University of South Florida (11)
- Old Dominion University (8)
- University of Denver (8)
-
- University of Nevada, Las Vegas (4)
- Washington University in St. Louis (4)
- City University of New York (CUNY) (3)
- University of Nebraska at Omaha (3)
- California Polytechnic State University, San Luis Obispo (2)
- New Jersey Institute of Technology (2)
- University of Kentucky (2)
- American University in Cairo (1)
- Bucknell University (1)
- Duquesne University (1)
- Embry-Riddle Aeronautical University (1)
- Florida Institute of Technology (1)
- Mississippi State University (1)
- University of Louisville (1)
- University of Nebraska - Lincoln (1)
- University of Texas Rio Grande Valley (1)
- West Virginia University (1)
- Wright State University (1)
- Keyword
-
- Biomechanics (14)
- Daniel Felix Ritchie School of Engineering and Computer Science (7)
- Kinematics (6)
- Mechanical and Materials Engineering (6)
- Electromyography (3)
-
- Gait (3)
- Amputee (2)
- Finite element (2)
- Finite element analysis (2)
- In Vitro (2)
- Knee (2)
- Knee kinematics (2)
- Model (2)
- Optimization (2)
- Pelvis (2)
- Prosthetic (2)
- Rehabilitation (2)
- Therapy (2)
- Total knee arthroplasty (2)
- Total knee arthroplasty (TKA) (2)
- Transfemoral (2)
- Traumatic brain injury (2)
- Walking (2)
- 3D Printed (1)
- 3D Stem Cell Culture (1)
- 9DoF (1)
- ADL (1)
- AGING (1)
- Abduction (1)
- Accelerometer (1)
- Publication Year
- Publication
-
- Mechanical and Aerospace Engineering Faculty Publications (17)
- USF Tampa Graduate Theses and Dissertations (11)
- Wayne State University Dissertations (10)
- Electronic Theses and Dissertations (8)
- McKelvey School of Engineering Graduate Student Theses & Dissertations (4)
-
- Theses and Dissertations (4)
- UNLV Theses, Dissertations, Professional Papers, and Capstones (4)
- Mechanical & Aerospace Engineering Theses & Dissertations (3)
- Publications and Research (3)
- UNO Student Research and Creative Activity Fair (3)
- Dissertations (2)
- Human Movement Studies & Special Education Theses & Dissertations (2)
- Wayne State University Theses (2)
- Best Integrated Writing (1)
- Biomedical Engineering Faculty Publications (1)
- Center for Orthopaedic Biomechanics: Faculty Scholarship (1)
- College of Engineering & Technology (Batten) Posters (1)
- Department of Mechanical and Materials Engineering: Dissertations, Theses, and Student Research (1)
- Discovery Day - Daytona Beach (1)
- Graduate Theses, Dissertations, and Problem Reports (ETD) (1)
- Honors Theses (1)
- Human Movement Studies & Special Education Faculty Publications (1)
- Living Kinematics of the Knee (1)
- Master's Theses (1)
- Mechanical Engineering (1)
- Rehabilitation Sciences Faculty Publications (1)
- Theses and Dissertations--Biomedical Engineering (1)
- Publication Type
Articles 61 - 87 of 87
Full-Text Articles in Biomechanics
Development Of A Muscle Model Parameter Calibration Method Via Passive Muscle Force Minimization, Allison Kinney, Benjamin J. Fregly
Development Of A Muscle Model Parameter Calibration Method Via Passive Muscle Force Minimization, Allison Kinney, Benjamin J. Fregly
Mechanical and Aerospace Engineering Faculty Publications
Computational predictions of subject-specific muscle and knee joint contact forces during walking may improve individual rehabilitation treatment design. Such predictions depend directly on specified model parameter values. However, model parameters are difficult to measure non-invasively. Methods for muscle model parameter calibration have been developed previously. However, it is currently unknown how the musculoskeletal system chooses muscle model parameter values. Previous studies have hypothesized that muscles avoid injury during walking by generating little passive force and operating in the ascending region of the force-length curve. This hypothesis suggests that muscle model parameter values may be selected by the body to minimize …
The Influence Of Neuromusculoskeletal Model Calibration Method On Predicted Knee Contact Forces During Walking, Gil Serrancolí, Allison Kinney, Benjamin J. Fregly, Josep M. Font-Llagunes
The Influence Of Neuromusculoskeletal Model Calibration Method On Predicted Knee Contact Forces During Walking, Gil Serrancolí, Allison Kinney, Benjamin J. Fregly, Josep M. Font-Llagunes
Mechanical and Aerospace Engineering Faculty Publications
This study explored the influence of three model calibration methods on predicted knee contact and leg muscle forces during walking. Static optimization was used to calculate muscle activations for all three methods. Approach A used muscle-tendon model parameter values (i.e., optimal muscle fiber lengths and tendon slack lengths) taken directly from literature. Approach B used a simple algorithm to calibrate muscle-tendon model parameter values such that each muscle operated within the ascending region of its normalized force-length curve. Approach C used a novel two-level optimization procedure to calibrate muscle-tendon, moment arm, and neural control model parameter values while simultaneously predicting …
An Investigation Of The Relationship Between Axonal Injury, Biomarker Expression And Mechanical Response In A Rodent Head Impact Acceleration Model, Yan Li
Wayne State University Dissertations
In the United States 1.4 million people sustain traumatic brain injury (TBI) each year, resulting in 235,000 hospitalizations and 50,000 fatalities annually. Traumatic axonal injury (TAI) is a serious outcome of TBI that accounts for 40-50% of hospitalizations due to head injury and one third of the mortality due to TBI, and it is difficult to diagnose and evaluate. The purpose of this dissertation is to determine mechanical injury predictors for TAI and identify potential biomarkers to evaluate TAI.
In this dissertation, a modified Marmarou impact acceleration injury model was developed to allow the monitoring of velocity of the impactor …
A Multi-Directional Treadmill Training Program For Improving Gait, Balance, And Mobility In Individuals With Parkinson’S Disease: A Case Series, Kimberly Smith, Kurt Jackson, Kimberly Edginton Bigelow, Lloyd L. Laubach
A Multi-Directional Treadmill Training Program For Improving Gait, Balance, And Mobility In Individuals With Parkinson’S Disease: A Case Series, Kimberly Smith, Kurt Jackson, Kimberly Edginton Bigelow, Lloyd L. Laubach
Mechanical and Aerospace Engineering Faculty Publications
Treadmill training is a commonly used intervention for improving gait in people with Parkinson’s disease (PD). However, little is known about how treadmill training may also influence balance and other aspects of mobility.
The purpose of this case series was to explore the feasibility and possible benefits of multi-directional treadmill training for individuals with PD. Four participants (62.3 ± 6.5 yrs, Hoehn & Yahr 2-4) performed 8 weeks of treadmill training 3 times per week. Weeks 1-4 included forward walking only, while weeks 5-8 included forward and multi-directional walking. Participants were tested every 4 weeks on 4 separate occasions. Outcome …
How Sensitive Is The Deltoid Moment Arm To Joint Center Changes With Rtsa?, David Walker, Allison Kinney, Aimee Struk, Benjamin J. Fregly, Thomas Wright, Scott Banks
How Sensitive Is The Deltoid Moment Arm To Joint Center Changes With Rtsa?, David Walker, Allison Kinney, Aimee Struk, Benjamin J. Fregly, Thomas Wright, Scott Banks
Mechanical and Aerospace Engineering Faculty Publications
The goal of this study was to assess the sensitivity of the deltoid muscle moment arms as a function of joint configuration for an existing RTSA subject. High variations were found for all three deltoid components. Variation over the entire abduction arc was greatest in the anterior and lateral deltoid, while the posterior deltoid moment arm was mostly sensitive to joint center changes early in the abduction arc. Moment arm changes of 10-16mm represent a significant amount of the total deltoid moment arm. This means there is an opportunity to dramatically change the deltoid moments arms through surgical placement of …
Deltoid Moment Arms During Abduction: A Subject-Specific Musculoskeletal Modeling Study In Healthy Shoulders And Shoulders With Rtsa, David Walker, Allison Kinney, Aimee Struk, Benjamin J. Fregly, Thomas Wright, Scott Banks
Deltoid Moment Arms During Abduction: A Subject-Specific Musculoskeletal Modeling Study In Healthy Shoulders And Shoulders With Rtsa, David Walker, Allison Kinney, Aimee Struk, Benjamin J. Fregly, Thomas Wright, Scott Banks
Mechanical and Aerospace Engineering Faculty Publications
Reverse total shoulder arthroplasty (RTSA) is increasingly used in the United States since approval by the FDA in 2003. RTSA relieves pain and restores mobility in arthritic rotator cuff deficient shoulders. Though many advantages of RTSA have been demonstrated, there still are a variety of complications (implant loosening, shoulder impingement, infection, frozen shoulder) making apparent much still is to be learned how RTSA modifies normal shoulder function. The goal of this study was to assess how RTSA affects deltoid muscle moment generating capacity post-surgery using a subjectspecific computational model driven by in vivo kinematic data.
A Novel Approach To Estimation Of Patient-Specific Muscle Strength, David Walker, Allison Kinney, Benjamin J. Fregly, Thomas Wright, Scott Banks
A Novel Approach To Estimation Of Patient-Specific Muscle Strength, David Walker, Allison Kinney, Benjamin J. Fregly, Thomas Wright, Scott Banks
Mechanical and Aerospace Engineering Faculty Publications
Current modeling techniques have been used to model the Reverse Total Shoulder Arthroplasty (RTSA) to account for the geometric changes implemented after RTSA. Though these models have provided insight into the effects of geometric changes from RTSA these is still a limitation of understanding muscle function after RTSA on a patient-specific basis. The goal of this study sought to overcome this limitation by developing an approach to calibrate patient-specific muscle strength for an RTSA subject.
Skeletal Muscle Contraction Simulation: A Comparison In Modeling, Jonathan M. Ford
Skeletal Muscle Contraction Simulation: A Comparison In Modeling, Jonathan M. Ford
USF Tampa Graduate Theses and Dissertations
Computer generated three-dimensional (3-D) models are being used at increasing rates in the fields of entertainment, education, research, and engineering. One of the aspects of interest includes the behavior and function of the musculoskeletal system. One such tool used by engineers is the finite element method (FEM) to simulate the physics behind muscle mechanics. There are several ways to represent 3-D muscle geometry, namely a bulk, a central line of action and a spline model. The purpose of this study is to exmine how these three representations affect the overall outcome of muscle movement. This is examined in a series …
Formulation To Predict Lower Limb Muscle Forces During Gait, Gil Serrancolí, Jonathan P. Walter, Allison Kinney, A. Barjau, Benjamin J. Fregly, Josep M. Font-Llagunes
Formulation To Predict Lower Limb Muscle Forces During Gait, Gil Serrancolí, Jonathan P. Walter, Allison Kinney, A. Barjau, Benjamin J. Fregly, Josep M. Font-Llagunes
Mechanical and Aerospace Engineering Faculty Publications
The human body has more muscles than Degrees of Freedom (DoF), and that leads to indeterminacy in the muscle force calculation. This study proposes the formulation of an optimization problem to estimate the lower-limb muscle forces during a gait cycle of a patient wearing an instrumented knee prosthesis. The originality of that formulation consists of simulating muscle excitations in a physiological way while muscle parameters are calibrated. Two approaches have been considered. In Approach A, measured contact forces are applied to the model and all inverse dynamics loads are matched in order to get a physiological calibration of muscle parameters. …
Optimization Problem Formulation For Predicting Knee Muscle And Contact Forces During Gait, Gil Serrancolí, Jonathan P. Walter, Allison Kinney, Benjamin J. Fregly, Josep M. Font-Llagunes
Optimization Problem Formulation For Predicting Knee Muscle And Contact Forces During Gait, Gil Serrancolí, Jonathan P. Walter, Allison Kinney, Benjamin J. Fregly, Josep M. Font-Llagunes
Mechanical and Aerospace Engineering Faculty Publications
The human body has more muscles than degrees of freedom (DOF), which leads to indeterminacy in the muscle force calculation. In this study, an optimization problem to estimate the lower-limb muscle forces during a gait cycle of a patient wearing an instrumented knee prosthesis is formulated. It consists of simulating muscle excitations in a physiological way while muscle parameters are calibrated.
Design And Development Of A Stair Ascension Assistive Device For Transfemoral Amputees, Casey Michael Barbarino
Design And Development Of A Stair Ascension Assistive Device For Transfemoral Amputees, Casey Michael Barbarino
Master's Theses
Transfemoral amputees around the world experience increased difficulty in climbing stairs due to lack of muscle, balance, and other factors. The loss of a lower limb greatly diminishes the amount of natural force generation provided that is necessary to propel oneself up stairs. This study investigated possible solutions to the problem of stair ascension for transfemoral amputees by the means of designing and developing an externally attachable device to a prosthesis. The number of amputations from military service has greatly increased since 2008, which shows there is a clear need for assistive devices (Wenke, Krueger, & Ficke, 2012). With the …
Changes In In Vivo Knee Contact Forces Through Gait Modification, Allison Kinney, Thor F. Besier, Amy Slider, Scott L. Delp, Darryl D. D'Lima, Benjamin J. Fregly
Changes In In Vivo Knee Contact Forces Through Gait Modification, Allison Kinney, Thor F. Besier, Amy Slider, Scott L. Delp, Darryl D. D'Lima, Benjamin J. Fregly
Mechanical and Aerospace Engineering Faculty Publications
Gait modification represents a non-invasive method for reducing knee joint loading in patients with knee osteoarthritis. Previous studies have shown that a variety of gait modifications are effective in reducing the external knee adduction moment. The external knee adduction moment is often used as a surrogate measure of medial compartment force. However, a recent study showed that reductions in the external knee adduction moment do not guarantee reductions in medial compartment loads. Therefore, direct measurement of changes in knee contact force is important for determining the effectiveness of gait modifications. A previous study found that medial thrust gait and walking …
Biomechanical Testing On Cadaveric Spines For Different Treatments That Affect Lumbar Stability, Sabrina Alejandra Gonzalez Blohm
Biomechanical Testing On Cadaveric Spines For Different Treatments That Affect Lumbar Stability, Sabrina Alejandra Gonzalez Blohm
USF Tampa Graduate Theses and Dissertations
Stenosis is one of the most common causes for spinal surgery. Laminectomy decompression and fusion are surgical procedures prescribed for this condition. The intention of this work was to investigate the effects of a laminectomy decompression, followed by fusion, on a lumbar functional spinal unit (FSU) through in vitro dynamic (±8Nm at 0.125Hz) and quasi-static (±7.5Nm at 0.1Hz) biomechanical tests, for flexion, extension, bending and rotation motions.
Six FSUs where disarticulated from four human cadaveric lumbar spines (63 ± 12 years) and were tested under the following sequence: (1) intact, (2) laminectomy decompression, and (3) Pedicle Screw System (PSS), using …
Evaluation Of Transfer Technologies To Preserve Shoulder Function In Sci, Karen Michelle Mann
Evaluation Of Transfer Technologies To Preserve Shoulder Function In Sci, Karen Michelle Mann
USF Tampa Graduate Theses and Dissertations
This study investigated a series of independent unassisted and device-assisted transfers from a wheelchair to vehicle mock-up and vice versa while simultaneously capturing kinematic, kinetic and electromyographic (EMG) data of impaired volunteers. The study provides a venue for observation and evaluation of upper extremity (UE) joint stresses, muscular force and functional demands associated with transfers in persons with spinal cord injury (SCI) to ultimately prevent UE injury, minimize excessive stress, preserve functionality and limit pain. If people with SCI lose function of their UEs, due to pain and/or degeneration, they must then rely on others for everyday tasks.
Five paraplegic …
Football Helmet Fitment And Its Effect On Helmet Performance, Ron Jadischke
Football Helmet Fitment And Its Effect On Helmet Performance, Ron Jadischke
Wayne State University Theses
A method and system to objectively quantify helmet fitment was designed and developed. It measures the pressure between the energy-absorbing material in the helmet and the athlete's head. This system is also capable of measuring surface pressure during impact events. A volunteer-based field study was conducted to quantify how helmets were fitting athletes in a real-life setting. The helmets fit athletes in varying degrees of tightness and evenness. Most athletes (59%) had the highest pressures in the frontal area and 29% had the highest pressure in the occipital area. A large-sized helmet on the Hybrid III headform represented how most …
Contact Pressure Distribution Of Osteochondral Defects Of The Knee: Effects Of Non-Vertical Walls, Scott Ensminger
Contact Pressure Distribution Of Osteochondral Defects Of The Knee: Effects Of Non-Vertical Walls, Scott Ensminger
Wayne State University Theses
Purpose: To examine the relationship between well-shouldered osteochondral defects and
defects of different geometries by studying their effects on rim stress concentration and
load redistribution in the human knee.
Methods: Ten fresh-frozen cadaveric knees were mounted at 30° of flexion in a materials
testing machine. Digital electronic pressure sensors were placed in the medial and lateral
compartments of the knee. Dynamic pressure readings were recorded throughout the
loading and holding phases as each knee was loaded to 700N and held for 5 seconds.
Artificial defects were created in each knee to simulate well-shouldered defects and
beveled-defects. Loading was repeated for …
Effectiveness Of Group Kickboxing As A Means To Improve Gait And Balance In Individuals With Ms, Kurt Jackson, Kimberly Edginton Bigelow, Christina Cooper, Harold L. Merriman
Effectiveness Of Group Kickboxing As A Means To Improve Gait And Balance In Individuals With Ms, Kurt Jackson, Kimberly Edginton Bigelow, Christina Cooper, Harold L. Merriman
Mechanical and Aerospace Engineering Faculty Publications
In recent years, there has been a particular emphasis on identifying and delivering appropriate therapeutic interventions that address the significant balance and gait impairments that affect individuals with multiple sclerosis (MS). Group interventions implemented in community settings have been especially of interest, including tai chi classes. Recently, the authors conducted a preliminary study to examine whether group kick-boxing, which requires more vigorous movements, might be a feasible intervention. Initial findings showed promise and led the authors to pursue a more rigorous follow-up study, with the objective of determining whether a 5-week group kickboxing class improved clinical measures of balance and …
Muscle Contributions To Frontal And Transverse Plane Whole-Body Angular Momentum, Richard R. Neptune, Craig P. Mcgowan, Allison Kinney
Muscle Contributions To Frontal And Transverse Plane Whole-Body Angular Momentum, Richard R. Neptune, Craig P. Mcgowan, Allison Kinney
Mechanical and Aerospace Engineering Faculty Publications
The purpose of this study was to build upon previous work by analyzing how gravity and individual muscles contribute to frontal and traverse plane whole-body angular momentum. Identifying which muscles are responsible for generating angular momentum has important implications for the diagnosis and treatment of movement disorders.
Finite Element Reconstruction Of Real World Aortic Injury In Near-Side Lateral Automotive Crashes With Conceptual Countermeasures, Aditya Neelakanta Belwadi
Finite Element Reconstruction Of Real World Aortic Injury In Near-Side Lateral Automotive Crashes With Conceptual Countermeasures, Aditya Neelakanta Belwadi
Wayne State University Dissertations
Traumatic rupture of the aorta (TRA) remains the second most common cause of death associated with motor vehicle crashes after brain injury. On an average, nearly 8,000 people die annually in the United States due to blunt injury to the aorta. It is observed that more than 80% of occupants who suffer an aortic injury die at the scene due to exsanguination into the chest. With the advent of more accurate and established human body finite element (FE) models, FE crash reconstruction methods may become a valuable tool when assessing crash scenarios and occupant injury mechanisms.
The current study is …
A Multi-Species Analysis Of Biomechanical Responses Of The Head To A Shock Wave, Richard Bolander
A Multi-Species Analysis Of Biomechanical Responses Of The Head To A Shock Wave, Richard Bolander
Wayne State University Dissertations
Shock wave induced brain injury remains a field of research that has great consequences for the rehabilitation of soldiers and civilians that are exposed to an explosion. As such, for the research to be successful in developing strategies to mitigate the effects of these injuries, appropriate research methods need to be developed. Animal models are currently employed to understand the brain's response to a shock wave exposure. Unfortunately no criteria have been established that indicates in what way the mechanical inputs that the cells in an animal's brain are subjected to are similar to a human. The purpose of this …
Computational Simulation Of Skull Fracture Patterns In Pediatric Subjects Using A Porcine Model, Christina Devito Wagner
Computational Simulation Of Skull Fracture Patterns In Pediatric Subjects Using A Porcine Model, Christina Devito Wagner
Wayne State University Dissertations
In cases of suspected child abuse with skeletal trauma, it is often the role of the injury biomechanist, forensic pathologist, clinical radiologist, and forensic anthropologist to determine the mechanism of injury when the child victims cannot speak for themselves. This is a challenging task, especially for the head, as comprehensive biomechanical data on skull fracture in infants and children do not currently exist, and frequently the determination regarding cause of injury is based on anecdotal evidence from the medical literature and unsubstantiated eyewitness accounts. The current process may result in unreliable autopsy interpretation and miscarriages of justice due to a …
Development Of Software To Estimate Pressures On The Residual Limbs Of Amputees By Means Of A Pylon Mounted Transducer, Malli K. Yalamanchili
Development Of Software To Estimate Pressures On The Residual Limbs Of Amputees By Means Of A Pylon Mounted Transducer, Malli K. Yalamanchili
UNLV Theses, Dissertations, Professional Papers, and Capstones
The alignment of prosthesis has been recognized as one of the main factors that determine successful prosthetic outcomes for trans-tibial amputees. Alignment is defined as the relative position and orientation of the prosthetic components. Misalignment can result in changes in the position and orientation of the joints of the leg and moments experienced by them during gait, increases in energy use, and discomfort or even tissue breakdown at the socket/stump interface. Hence it is very important to align the prosthesis in correct manner. Gait analysis can be used to examine the effects of incorrect alignment of the prosthesis during gait. …
Pre-Swing Deficits In Forward Propulsion, Swing Initiation And Power Generation By Individual Muscles In Hemiparetic Walking, Carrie L. Peterson, Allison Kinney, Steven A. Kautz, Richard R. Neptune
Pre-Swing Deficits In Forward Propulsion, Swing Initiation And Power Generation By Individual Muscles In Hemiparetic Walking, Carrie L. Peterson, Allison Kinney, Steven A. Kautz, Richard R. Neptune
Mechanical and Aerospace Engineering Faculty Publications
Clinical studies of hemiparetic walking have shown pre-swing abnormalities in the paretic leg suggesting that paretic muscle contributions to important biomechanical walking subtasks are different than those of non-disabled individuals. Three-dimensional forward dynamics simulations of two representative hemiparetic subjects with different levels of walking function classified by self-selected walking speed (i.e., limited community=0.4–0.8 m/s and community walkers=>0.8 m/s) and a speed-matched control were generated to quantify individual muscle contributions to forward propulsion, swing initiation and power generation during the pre-swing phase (i.e., double support phase proceeding toe-off). Simulation analyses identified decreased paretic soleus and gastrocnemius contributions to forward propulsion …
Relationships Between Muscle Contributions To Walking Subtasks And Functional Walking Status In Persons With Post-Stroke Hemiparesis, Allison Kinney, Carrie L. Peterson, Steven A. Kautz, Richard R. Neptune
Relationships Between Muscle Contributions To Walking Subtasks And Functional Walking Status In Persons With Post-Stroke Hemiparesis, Allison Kinney, Carrie L. Peterson, Steven A. Kautz, Richard R. Neptune
Mechanical and Aerospace Engineering Faculty Publications
Walking speed is commonly used to predict stroke severity and assess functional walking status (i.e., household, limited community and community walking status) post-stroke. The underlying mechanisms that limit walking speed (and functional walking status by extension) need to be understood to improve post-stroke rehabilitation. Previous experimental studies have shown correlations between paretic plantarflexor output during the pre-swing phase and walking speed and suggest that the paretic hip flexors can compensate in some hemiparetic subjects. Modeling and simulation studies of healthy walking have shown that the ankle plantarflexors, soleus (SOL) and gastrocnemius (GAS), and uniarticular hip flexors (IL) are essential contributors …
Fabrication Of Ankle-Foot Orthoses Using Selective Laser Sintering Technology, Allison Kinney, M. C. Faustini, Richard R. Neptune, R. H. Crawford, S. J. Stanhope
Fabrication Of Ankle-Foot Orthoses Using Selective Laser Sintering Technology, Allison Kinney, M. C. Faustini, Richard R. Neptune, R. H. Crawford, S. J. Stanhope
Mechanical and Aerospace Engineering Faculty Publications
Passive dynamic ankle-foot orthoses (AFOs) are often prescribed to improve gait performance for those with various neuromuscular disorders. Designs and materials used for AFOs range from simple polypropylene braces to advanced custom carbon fiber dynamic AFOs that passively store and release mechanical energy during gait. AFO designs vary in the shape and length of the foot component as well as the stiffness and length of the tibial component, depending on the desired functional outcomes. However, the current fabrication technology is not ideally suited for refined customization of AFO characteristics to optimize performance, or for rapid lowcost, high volume manufacturing and …
Development And Analysis Of A Software Package To Quantify In Vivo Polyethylene Wear After Total Hip Arthroplasty, Allison Kinney, Catherine G. Ambrose
Development And Analysis Of A Software Package To Quantify In Vivo Polyethylene Wear After Total Hip Arthroplasty, Allison Kinney, Catherine G. Ambrose
Mechanical and Aerospace Engineering Faculty Publications
Since the first total hip arthroplasty (THA) in 1938, THA evolved and developed into one of the major concentrations of orthopaedic research. The typical hip implant device used today incorporates a femoral and an acetabular component that serve to replicate the anatomical and mechanical functions of the natural hip joint. However, several problems exist that can effect the function of the implant device. Wear in the polyethylene liner of the acetabular component of the total hip replacement device is known as one of the major factors that affects the longevity of total hip replacement devices. Both manual and computer-aided techniques …
Microscale Investigation Of Thermo-Fluid Transport In The Transition Fil, Region Of An Evaporating Capillary Meniscus Using A Microgravity Environment, Kenneth D. Kihm, Jeffrey S. Allen, Kevin P. Hallinan, David M. Pratt
Microscale Investigation Of Thermo-Fluid Transport In The Transition Fil, Region Of An Evaporating Capillary Meniscus Using A Microgravity Environment, Kenneth D. Kihm, Jeffrey S. Allen, Kevin P. Hallinan, David M. Pratt
Mechanical and Aerospace Engineering Faculty Publications
In order to enhance the fundamental understanding of thin film evaporation and thereby improve the critical design concept for two-phase heat transfer devices, microscale heat and mass transport is to be investigated for the transition film region using state-of-the-art optical diagnostic techniques. By utilizing a microgravity environment, the length scales of the transition film region can be extended sufficiently, from submicron to micron, to probe and measure the microscale transport fields which are affected by intermolecular forces. Extension of the thin film dimensions under microgravity will be achieved by using a conical evaporator made of a thin silicon substrate under …