Open Access. Powered by Scholars. Published by Universities.®
Biochemistry, Biophysics, and Structural Biology Commons™
Open Access. Powered by Scholars. Published by Universities.®
- Institution
-
- University of Nebraska - Lincoln (53)
- Augustana College (27)
- University of Kentucky (26)
- City University of New York (CUNY) (24)
- The Texas Medical Center Library (19)
-
- Virginia Commonwealth University (13)
- Old Dominion University (12)
- Wilfrid Laurier University (11)
- Western University (10)
- University of Missouri, St. Louis (9)
- Wayne State University (9)
- Universitas Indonesia (8)
- University of Arkansas, Fayetteville (8)
- University of Nebraska Medical Center (7)
- University of South Florida (7)
- Claremont Colleges (6)
- Duquesne University (6)
- Lawrence University (6)
- Louisiana State University (6)
- Northwestern College, Iowa (6)
- University at Albany, State University of New York (6)
- University of Connecticut (6)
- University of Nevada, Las Vegas (6)
- University of Texas at El Paso (6)
- California Polytechnic State University, San Luis Obispo (5)
- Kennesaw State University (5)
- Michigan Technological University (5)
- Technological University Dublin (5)
- West Virginia University (5)
- Dartmouth College (4)
- Keyword
-
- Bioinformatics (70)
- Genome (27)
- Meiothermus ruber (25)
- Annotation (24)
- GENI-ACT (21)
-
- Protein (19)
- Evolution (10)
- Genomics (9)
- Machine learning (9)
- Biochemistry (8)
- Epigenetics (8)
- Genetics (8)
- Proteomics (8)
- Humans (7)
- Microbiome (7)
- Computational Biology (6)
- Killifish (6)
- Teaching (6)
- Transcriptomics (6)
- ABC transporter (5)
- Biology (5)
- Machine Learning (5)
- MicroRNA (5)
- Molecular dynamics (5)
- Protein folding (5)
- Protein structure (5)
- SARS-CoV-2 (5)
- Software (5)
- Structural biology (5)
- Systems biology (5)
- Publication Year
- Publication
-
- Biomedical Imaging and Biosignal Analysis Laboratory (26)
- Meiothermus ruber Genome Analysis Project (26)
- Dissertations, Theses, and Capstone Projects (19)
- Dissertations and Theses (Open Access) (17)
- Theses and Dissertations (16)
-
- Electronic Theses and Dissertations (15)
- Athletic Performance Research (11)
- Biochemistry Publications (10)
- Theses and Dissertations (Comprehensive) (9)
- Graduate Theses and Dissertations (8)
- Molecular and Cellular Biochemistry Faculty Publications (8)
- Wayne State University Dissertations (8)
- Makara Journal of Science (7)
- Theses & Dissertations (7)
- USF Tampa Graduate Theses and Dissertations (7)
- Killifish Research Review (6)
- Protein Domains (6)
- Chemistry & Biochemistry Faculty Works (5)
- Dissertations, Master's Theses and Master's Reports (5)
- Honors Scholar Theses (5)
- Legacy Theses & Dissertations (2009 - 2024) (5)
- Master's Theses (5)
- Symposium of Student Scholars (5)
- Articles (4)
- Biology Faculty Publications (4)
- Department of Biological Sciences Publications (4)
- Graduate Theses, Dissertations, and Problem Reports (ETD) (4)
- LSU Doctoral Dissertations (4)
- Publications and Research (4)
- UNLV Theses, Dissertations, Professional Papers, and Capstones (4)
- Publication Type
- File Type
Articles 451 - 460 of 460
Full-Text Articles in Biochemistry, Biophysics, and Structural Biology
Flash Artifact Suppression In Two-Dimensional Ultrasound Imaging, Richard Yung Chiao, Gregory Ray Bashford, Mark Peter Feilen, Cynthia Andrews Owen
Flash Artifact Suppression In Two-Dimensional Ultrasound Imaging, Richard Yung Chiao, Gregory Ray Bashford, Mark Peter Feilen, Cynthia Andrews Owen
Biomedical Imaging and Biosignal Analysis Laboratory
Flash artifacts in ultrasound flow images are suppressed to achieve enhanced flow discrimination. Flash artifacts typically occur as region of elevated signal strength (brightness or equivalent color) within an image. A flash suppression algorithm included the steps of estimating the flash within an image and then suppressing the estimated flash. The mechanism for flash suppression is spatial filtering. An extension of this basic method used information from adjacent frames to estimate the flash and/or to smooth the resulting image sequence. Temporal information from adjacent frames is used as an adjunct to improve performance.
Evaluation Of Multiple Models To Distinguish Closely Related Forms Of Disease Using Dna Microarray Data: An Application To Multiple Myeloma, Johanna S. Hardin, Michael Waddell, C. David Page, Fenghuang Zhan, Bart Barlogie, John Shaughnessy, John J. Crowley
Evaluation Of Multiple Models To Distinguish Closely Related Forms Of Disease Using Dna Microarray Data: An Application To Multiple Myeloma, Johanna S. Hardin, Michael Waddell, C. David Page, Fenghuang Zhan, Bart Barlogie, John Shaughnessy, John J. Crowley
Pomona Faculty Publications and Research
Motivation: Standard laboratory classification of the plasma cell dyscrasia monoclonal gammopathy of undetermined significance (MGUS) and the overt plasma cell neoplasm multiple myeloma (MM) is quite accurate, yet, for the most part, biologically uninformative. Most, if not all, cancers are caused by inherited or acquired genetic mutations that manifest themselves in altered gene expression patterns in the clonally related cancer cells. Microarray technology allows for qualitative and quantitative measurements of the expression levels of thousands of genes simultaneously, and it has now been used both to classify cancers that are morphologically indistinguishable and to predict response to therapy. It is …
A Neural Network Method For Protein Classification, Arie D. Jones
A Neural Network Method For Protein Classification, Arie D. Jones
All-Inclusive List of Electronic Theses and Dissertations
The investigation detailed in this paper attempts to utilize a Leaming Vector Quantization network in order to classify a set of mitochondrial proteins based upon their amino acid sequence. The Learning Vector Quantization network uses a nearest neighbor approach to classification. Input vectors are fed into the network, which produces output vectors. Those output vectors are then matched by means of a distance bias to a corresponding classification vector. The learning and test sets consisted of thirteen similar mitochodrial proteins from seventy-two different species. This provided a pool of over nine hundred proteins to use. Half of the species were …
Ultrasound Based Quantitative Motion Measurement Using Speckle Size Estimation, James D. Hamilton, Larry Y. L. Mo, Gregory R. Bashford
Ultrasound Based Quantitative Motion Measurement Using Speckle Size Estimation, James D. Hamilton, Larry Y. L. Mo, Gregory R. Bashford
Biomedical Imaging and Biosignal Analysis Laboratory
An ultrasound system determines the relative movement in a first direction (F1) of first matter, such as blood flow, and second matter, such as an artery wall, in a subject under study (S). A beam (B1) of ultrasound waves defining a plurality of beam positions (BP1 and BP2) and beam axes (A1 and A2) are moved in scan direction having components parallel to direction F1. First and second blocks of data representing the first and second matter, respectively, are generated. A processor (20) performs an estimation of speckle size on first data to obtain a first result, and performs analysis …
Method And Apparatus For Adaptive Filtering By Counting Acoustic Sample Zeroes In Ultrasound Imaging, Gregory R. Bashford, Edward D. Nonnweiler, David D. Becker, David John Muzilla
Method And Apparatus For Adaptive Filtering By Counting Acoustic Sample Zeroes In Ultrasound Imaging, Gregory R. Bashford, Edward D. Nonnweiler, David D. Becker, David John Muzilla
Biomedical Imaging and Biosignal Analysis Laboratory
An ultrasound imaging system having an adaptive spatial filter the filter coefficients of which, for particular image parameter sample, are determined by counting the number of neighboring image parameter samples having zero or near-zero values. If the number of zero or near-zero values in a data window is greater than a predetermined threshold, the data in the window is passed, not filtered. This filter has two advantages over other spatial filters. First, image parameter data samples having only zero or near-zero neighboring values (i.e., isolated "point noise") are not smeared. Second, boundaries such as the edge of color in a …
Method And Apparatus For Controlling Acoustic Signal Bandwidth In An Ultrasonic Diagnostic Imaging System, Jeffrey R. Resnick, Gregory R. Bashford
Method And Apparatus For Controlling Acoustic Signal Bandwidth In An Ultrasonic Diagnostic Imaging System, Jeffrey R. Resnick, Gregory R. Bashford
Biomedical Imaging and Biosignal Analysis Laboratory
An ultrasonic imaging system includes a receive beamformer that generates analog receive signals and a scan converter. A receive signal processing path interconnects the receive beamformer and the scan converter, and this processing path included both an A/D converter characterized by a selectable sampling rate and at least one filter characterized by at least one filter parameter. The filter parameter is selected as a function of the sampling rate to provide enhanced image quality.
Method And Apparatus For Three-Dimensional Ultrasound Imaging Of Biopsy Needle, Syed Omar Ishrak, Mir Said Seyed-Bolorforosh, William Thomas Hatfield, Todd Michael Tillman, Brian Peter Geiser, Gregory R. Bashford, Michael Joseph Washburn
Method And Apparatus For Three-Dimensional Ultrasound Imaging Of Biopsy Needle, Syed Omar Ishrak, Mir Said Seyed-Bolorforosh, William Thomas Hatfield, Todd Michael Tillman, Brian Peter Geiser, Gregory R. Bashford, Michael Joseph Washburn
Biomedical Imaging and Biosignal Analysis Laboratory
A method and an apparatus for three-dimensional ultrasound imaging of a needle-like instrument, such as a biopsy needle, inserted in a human body. The instrument is visualized by transmitting ultrasound beams toward the instrument and then detecting the echo signals using a linear array of transducer elements. The problem of ultrasound being reflected from a biopsy needle in a direction away from the transducer array is solved by steering the transmitted ultrasound beams t increase the angle at which the beams impinge upon the biopsy needle. Ideally the ultrasound beams are perpendicular to the needle. This increases the system's sensitivity …
Method And Apparatus For Controlling Acoustic Signal Bandwidth In An Ultrasonic Diagnostic Imaging System, Jeffrey R. Resnick, Gregory R. Bashford
Method And Apparatus For Controlling Acoustic Signal Bandwidth In An Ultrasonic Diagnostic Imaging System, Jeffrey R. Resnick, Gregory R. Bashford
Biomedical Imaging and Biosignal Analysis Laboratory
An ultrasonic imaging system includes a receive beam former that generates analog receive signals and a scan converter. A receive signal processing path interconnects the receive beamformer and the scan converter, and this processing path includes both an A/D converter characterized by a selectable sampling rate and at least one filter characterized by at least one filter parameter. The filter parameter is selected as a function of the sampling rate to provide enhanced image quality.
Ultrasound Three- Dimensional Velocity Measurements By Feature Tracking, Gregory R. Bashford, Olaf T. Von Ramm
Ultrasound Three- Dimensional Velocity Measurements By Feature Tracking, Gregory R. Bashford, Olaf T. Von Ramm
Biomedical Imaging and Biosignal Analysis Laboratory
This article describes a new angle-independent method suitable for three-dimensional (3-D) blood flow velocity measurement that tracks features of the ultrasonic speckle produced by a pulse echo system. In this method, a feature is identified and followed over time to detect motion. Other blood flow velocity measurement methods typically estimate velocity using one- (1-D) or two-dimensional (2-D) spatial and time information. Speckle decorrelation due to motion in the elevation dimension may hinder this estimate of the true 3-D blood flow velocity vector. Feature tracking is a 3-D method with the ability to measure the true blood velocity vector rather than …
Some Field Instruments And Their Applications, G. W. Goldsmith
Some Field Instruments And Their Applications, G. W. Goldsmith
University Studies (University of Nebraska) (1888–1984)
Physiology and ecology depend for their constructive development largely upon the applications of physico-chemical concepts to living organisms and their environment, to their life processes, reactions, and interrelations. A concept is valuable biologically in so far as it can be applied and used as a tool for better understanding of the phenomena related to life. Ecology, as the study of the relations between organisms and their environment and of the interrelations of organisms, depends primarily upon the findings of physiology (Clements, 1905). But to apply physicochemical concepts and hence make them of value to the physiologist or ecologist commonly requires …