Sheraton Hotel- Life Safety Report, Raul M. Farfan Jun 2016

Sheraton Hotel- Life Safety Report, Raul M. Farfan

Fire Protection Engineering: Culminating Experience Project Reports

This report evaluates the prescriptive life safety requirements for levels one (1) through four (4) of the Sheraton Hotel in downtown Phoenix. In addition, this report discusses two fire scenarios that evaluate the tenability during egress the in pre-function area on level two (2) and in the main ballroom on level three (3) of the hotel.

The prescriptive standards/codes used to evaluate the hotel are the International Building Code (IBC), International Fire Code (IFC), and applicable standards from the National Fire Protection Association (NFPA). Performance based analysis were conducted using Pathfinder, CFast, and Fire Dynamic Simulator (FDS). Two fire scenarios …


Building X- Fire Protection System And Life Safety Evaluation, Anthony W. Sublett Jun 2016

Building X- Fire Protection System And Life Safety Evaluation, Anthony W. Sublett

Fire Protection Engineering: Culminating Experience Project Reports

The fire protection and life safety systems for Building X were evaluated for compliance in accordance with applicable nuclear power plant non-power block regulatory requirements, NEIL, INPO, IBC, and NFPA design requirements, codes, and standards. Building X is a one-story building with two internal balconies with 10 occupants per balcony, which is made of non-combustible materials that also has a partial basement with concrete walls (is normally unoccupied), which houses potable water pumps and piping for the facility. Building X falls under the definition of mixed occupancy per the International Building Code (IBC) and the Life Safety Code (LSC). Since …


Analysis Of Costco, San Francisco, Ian Levine Jun 2016

Analysis Of Costco, San Francisco, Ian Levine

Fire Protection Engineering: Culminating Experience Project Reports

This report provides an in-depth analysis of the fire safety systems and design considerations of the Costco store located at 450 10th Street in San Francisco, California, satisfying the requirements for completion of the FPE 596 – Culminating Experience in Fire Protection Engineering academic series. The building is introduced, followed by an analysis of the building structure, alarm and detection, egress, and sprinkler systems are designed based on prescriptive code. These systems are then analyzed from a performance based perspective to gain understanding of how the systems will respond to a challenging design fire. Their response is used to determine …


Office High Rise Building- Fire Protection And Life Safety Analysis, Fabio Renato Zocal Mazza Jun 2016

Office High Rise Building- Fire Protection And Life Safety Analysis, Fabio Renato Zocal Mazza

Fire Protection Engineering: Culminating Experience Project Reports

This project developed the traditional prescriptive-based design analysis of the fire protection features of an existing office high rise building in the city of Sao Paulo, in Brazil. The analysis was then complemented by performance-based analysis of the building. The building is a high rise office located in a metropolitan area, provided also with underground car parking garages and a small theater. The fire protection analysis was conducted based on the local Sao Paulo state fire codes, mainly the Sao Paulo State enactment (Decreto Nº56.819/2011) and Sao Paulo Fire Department Technical Instructions; and, in addition to the local codes, the …


3-Bay Aircraft General Maintenance Hangar- United States Air Force, Zach Ataiyan Jun 2016

3-Bay Aircraft General Maintenance Hangar- United States Air Force, Zach Ataiyan

Fire Protection Engineering: Culminating Experience Project Reports

This report contains a prescriptive design analysis and a performance based design analysis for a newly constructed United States Air Force 3-Bay Aircraft General Maintenance Hangar and support spaces.

The prescriptive design analysis reviews the code requirements for fire suppression, fire alarm, life safety, and structural fire protection. Additionally, the hydraulic demands of the fire suppression system, and the voltage drop and power supply requirements of the fire alarm systems were calculated. The results of the analysis portray a compliant prescriptive design of the fire protection systems.

The performance based design analysis evaluates the hazards in the 3-bay facility for …


Monticello Office Building- Fire And Life Safety Analysis, Mark James Masciarelli Jun 2016

Monticello Office Building- Fire And Life Safety Analysis, Mark James Masciarelli

Fire Protection Engineering: Culminating Experience Project Reports

A Fire and Life Safety analysis was performed on the existing Monticello Office Building located in Delaware, USA. The Monticello Office Building is a mixed use building that contains office space to support a population of 700 people, dining facilities to accommodate approximately 400 people, and a conference area for up to 125 people. The building is composed of two major components; a five (5) story office wing and a one (1) and two (2) story amenities wing that mainly houses the food service, dining, kitchen, retail and conference areas. A prescriptive analysis of this building was performed to determine …


Maintenance Shop Building- Comprehensive Fire Protection Evaluation, Theodore P. Stanton Mar 2016

Maintenance Shop Building- Comprehensive Fire Protection Evaluation, Theodore P. Stanton

Fire Protection Engineering: Culminating Experience Project Reports

The purpose of this report is to analyze the fire protection systems and features of the Maintenance Shop Building (MSB), which is a two story office and training building on the campus of a large industrial facility in central California. The goal of the fire protection systems and features of the Building is to provide occupants with reasonable assurance of safety from fire. This goal can be met by ensuring that occupants not intimate with the initiation of a fire will be able to safely escape from the Building in the event of the fire.

The ability of the MSB’s …


Technical Area 3 - 40; Physics Building- Fire And Life Safety Analysis, Parker Fellows Mar 2016

Technical Area 3 - 40; Physics Building- Fire And Life Safety Analysis, Parker Fellows

Fire Protection Engineering: Culminating Experience Project Reports

A Fire Protection Engineering Analysis was performed on TA‐3‐0040, Physics Building at the Los Alamos National Laboratory in Los Alamos, New Mexico. The goal of the analysis has two parts; first, to examine the buildings fire protection features from a code based prescriptive analysis and second, to examine the building and fire protection features using a performance based design analysis.

Building 40 is a 2 story structure approximately 187,000 square feet. The building was constructed in the mid‐1950s with a first floor, basement, partial sub‐basement, and various mezzanines. Originally, this building was constructed as a non‐combustible type IIB structure according …


Taylor Place- Fire Life Safety Report, Christopher Thomas Mar 2016

Taylor Place- Fire Life Safety Report, Christopher Thomas

Fire Protection Engineering: Culminating Experience Project Reports

This document is a Fire and Life Safety Report on the Taylor Place Dormitory located in Phoenix, Arizona as part of the Arizona State University (ASU) downtown campus. The building was evaluated on a prescriptive basis based on the current City of Phoenix building codes and further evaluated on using performance based methods from the Society of Fire Protection Engineers (SFPE) Handbook and National Fire Protection Association (NFPA) 101 Life Safety Code®.

These building features and systems were evaluated using prescriptive methods:

General construction, fire resistive construction and fire resistive separations Occupancy, Life safety features and building egress Smoke management …


Micro-Mechanics: Fire And Life Safety Evaluation, Michael Beam Mar 2016

Micro-Mechanics: Fire And Life Safety Evaluation, Michael Beam

Fire Protection Engineering: Culminating Experience Project Reports

The purpose of this report is to perform a fire and life safety evaluation of an existing building, Micro-Mechanics. The current codes and standards are used to evaluate the following prescriptive fire protection systems including: Occupancy and Hazard Classification, Structural Fire Protection, Egress Analysis, Fire Detection, Alarm and Communication Systems, and Fire Suppression Systems. An evaluation of possible special hazards is discussed to determine if any extra precautions need to be taken to prevent uncontrollable fire or explosions. A performance based analysis is used to evaluate the effectiveness of the prescriptive building systems. Using a combination of computer models including …


Fire Hazard Analysis Of Technical Area 53 Building 1, Los Alamos National Lab, Brett L. Noakes Jun 2015

Fire Hazard Analysis Of Technical Area 53 Building 1, Los Alamos National Lab, Brett L. Noakes

Fire Protection Engineering: Culminating Experience Project Reports

This is an analysis of a 1970’s vintage building as it is compared to current building codes and standards. The purpose of this document is to assess if the current, as found construction of an existing building could achieve the sometimes more restrictive modern building codes. Both a prescriptive analysis and a performance-based analysis were completed to verify life-safety concerns and criteria as well as construction criteria. The prescriptive analysis compared existing, as found construction to current codes and standards while the prescriptive analysis used modern fire modeling techniques to see how likely fire scenarios would challenge the structure, if …


Fire Protection Analysis Of Warren J. Baker Center For Science, Aric E. Carracino Jun 2015

Fire Protection Analysis Of Warren J. Baker Center For Science, Aric E. Carracino

Fire Protection Engineering: Culminating Experience Project Reports

A prescriptive and performance based analysis was performed on the Warren J Baker Center for Science on the California Polytechnic San Luis Obispo campus. The code based analysis included reviewing the building’s egress components, structural fire protection, fire sprinkler system, and fire alarm system. This included the requirements of the California Building Code, as well as applicable NFPA codes. Analysis of the egress components of the building revealed several dead end corridors within the building that exceed the maximum allowed length of 50 feet. In addition, the student workspace areas on Level 3 require two exits, but are only provided …


Fire And Life Safety Report- Battalion Headquarters Complex (Ueph), Mathew Mershimer Jun 2015

Fire And Life Safety Report- Battalion Headquarters Complex (Ueph), Mathew Mershimer

Fire Protection Engineering: Culminating Experience Project Reports

This fire and life safety report covers a Battalion Headquarters Complex that is used for housing military troops. This is a complete review of the building with prescriptive based fire protection along with performance base review of the building. The prescriptive fire protection covers egress analysis of the space, passive fire protection (i.e. fire walls and doors) and active fire protection (i.e. fire alarm and fire sprinklers). The performance based section looks at the prescriptive requirements and sees if these would be enough for the application at hand. The building fire protection and life safety are covered by three different …


Fire And Life Safety Evaluation & Analysis- Bonderson Engineering Projects Center, Garrett Brown Mar 2015

Fire And Life Safety Evaluation & Analysis- Bonderson Engineering Projects Center, Garrett Brown

Fire Protection Engineering: Culminating Experience Project Reports

A Fire and Life Safety Analysis of the Bonderson Engineering Projects Center, (BEPC) Building 197 on the California Polytechnic State University, San Luis Obispo (Cal Poly) Campus is performed. Both prescriptive and performance based methods and metrics are utilized to evaluate the facility with respect to current fire and building standards and codes. Prescriptive fire protection features and systems analyzed include: building construction type and design, structural fire protection features and requirements, occupancy classification and egress analysis, fire detection, alarm, and communication systems, and fire suppression systems The prescriptive based design requirements largely met the code and installation requirements with …


Solar Energy Research Center- Lawrence Berkeley National Laboratory!, Shellie Prescott Mar 2015

Solar Energy Research Center- Lawrence Berkeley National Laboratory!, Shellie Prescott

Fire Protection Engineering: Culminating Experience Project Reports

This report covers both a prescriptive and performance-based review of fire and life safety systems for the Solar Energy Research Center at the Lawrence Berkeley National Laboratory. The primary subjects covered are egress, fire alarm systems, and sprinkler systems. A unique feature and focal point for this report is the SERC east exit stair. This stair was originally designed as a glass atrium, but for various reasons cannot be utilized as an atrium. The east exit stair has a special VESDA detection system, is the most remote location for the sprinkler system, and is a primary exit for all three …


Culminating Project Report- Warren J. Baker Center For Science And Mathematics, Blake Johnson Mar 2015

Culminating Project Report- Warren J. Baker Center For Science And Mathematics, Blake Johnson

Fire Protection Engineering: Culminating Experience Project Reports

This report analyzes the fire protection features of the Warren J. Baker Center for Science and Mathematics on the Cal Poly San Luis Obispo campus in San Luis Obispo, CA. The prescriptive analysis of the structural fire protection, egress, fire suppression, and fire alarm, detection, and communication systems shows that the building meets the requirements of current codes and standards. The performance based analysis includes simulating design fire scenarios in the atrium using computer modeling (CFAST, FDS) and the results of these models show that the atrium meets the tenability criterion for the calculated evacuation time of occupants.


Fire And Life Safety Analysis- Building 310- The Landing, Tyler Paller Mar 2015

Fire And Life Safety Analysis- Building 310- The Landing, Tyler Paller

Fire Protection Engineering: Culminating Experience Project Reports

The purpose of this report is to analyze Building 310 with regards to fire and life safety. Analysis was done both prescriptively and from a performance based design standpoint. The prescriptive based analysis includes review of the building’s design with regards to egress, fire alarm systems, suppression systems, and structural fire protection. The building was reviewed against current NFPA codes and the International Building Code to examine compliance. The performance-based analysis consists of two different fire scenarios that were examined. The goal was to show that the building met safety criteria and does not pose undue risk to occupants. This …


Fire Protection And Life Safety Engineering Analysis- Center For Science And Mathematics, Orelvis Gonzalez Cruz Mar 2015

Fire Protection And Life Safety Engineering Analysis- Center For Science And Mathematics, Orelvis Gonzalez Cruz

Fire Protection Engineering: Culminating Experience Project Reports

The Life Safety and Fire Protection systems in Cal Poly’s Center for Science and Mathematics (CSM) were analyzed and evaluated in this project, according to the requirements of the applicable codes and pertinent standards. The evaluation was conducted through a prescriptive-based approach, in conjunction with a performance-based approach. On one hand, the prescriptive-based approach considered the analysis of the Structural Fire Protection and Means of Egress in the building and the existing Fire Detection/Alarm and Fire Suppression Systems. On the other hand, the performance-based approach included an Egress Analysis, which assessed the Required Safe Egress Time (RSET) and the Available …


Fire And Life Safety Analysis- Uw Medicine Lake Union Phase 3.1, Marge Hong Jun 2014

Fire And Life Safety Analysis- Uw Medicine Lake Union Phase 3.1, Marge Hong

Fire Protection Engineering: Culminating Experience Project Reports

This report provides a summary of the fire protection and life safety features for UW Medicine Lake Union, a research and laboratory building, in accordance with Seattle Building Code (SBC), International Building Code (IBC), and Life Safety Code (NFPA 101). The objective of this report is to identify if UW Medicine Lake Union meets both the prescriptive and performance based code. The primary fire safety goal is to provide life safety system that reduced the risk of fire-related injuries and loss of life due to fire. The prescriptive analysis is used to identify the building integrity per code. This evaluates …


Westside Christian High School, Michael Stewart Jun 2014

Westside Christian High School, Michael Stewart

Fire Protection Engineering: Culminating Experience Project Reports

The building I have chosen to use as the model for exemplifying the components of a wet fire suppression system is Westside Christian High School (WCHS). This building completed construction in January of 2014 and is located at: 8200 SW Pfaffle Street Tigard, Oregon 97223. The existing structure was previously owned and occupied by City Bible Church who will now lease space from the High school during and after construction. The renovations include the addition of space for music, art classes, fitness center, gym, science labs, and others. The renovations will also be widening existing rooms and hallways. The core …


Fire Protection Analysis Robert And Margrit Modavi Center For The Performing Arts- Uc Davis, Jeffrey Paterson Jun 2014

Fire Protection Analysis Robert And Margrit Modavi Center For The Performing Arts- Uc Davis, Jeffrey Paterson

Fire Protection Engineering: Culminating Experience Project Reports

This document is the report of the culminating experience as part of the master’s program in fire protection engineering at the California Polytechnic State University, San Luis Obispo. This report contains a life safety analysis of the fire protection systems of a chosen project building. The building examined is the Robert and Margrit Mondavi Center for the Performing Arts, located on the University of California Davis campus. The building was constructed in 2002 where the first performance occurred in October 2002. A large portion of the report applies prescriptive code requirements to evaluate compliance with current codes and standards. The …


Hotel- Georgia, Rock Toler Jun 2014

Hotel- Georgia, Rock Toler

Fire Protection Engineering: Culminating Experience Project Reports

The State of Georgia modifies the International Building Code through State amendments, to require a fire resistance rating between residential occupancies and all other occupancies. This fire and life safety analysis report will substantiate the necessity for the barrier in a mixed-use hotel occupancy. The first-half of the report addresses the prescriptive-based code requirements, reporting a compliant design was presented. Then the performance portions primary objective was established, maintain a tenable environment for egressing guest room occupants. Three conditions were evaluated to define a tenable environment, carbon monoxide levels, temperature, and visibility limits. Selecting the location of the fire required …


Fire And Life Safety Analysis Of The Grant M. Brown Engineering Building- Cal Poly, Daniel Gregory Blanchat Jun 2014

Fire And Life Safety Analysis Of The Grant M. Brown Engineering Building- Cal Poly, Daniel Gregory Blanchat

Fire Protection Engineering: Culminating Experience Project Reports

This fire and life safety analysis was performed on the Grant M. Brown Engineering Building in order to determine if the building meets the life safety goals set forth by a prescriptive and performance based analysis. This building was built to a strict set of codes and standards. For the prescriptive analysis the buildings egress design, fire detection and alarm systems, fire sprinkler system, occupancy classification, construction type, and structural fire protection are evaluated in terms of the life safety of the occupants. In the performance based design analysis four computer based programs were used to model egress and fire …


Comprehensive Fire And Life Safety Analysis- Moa Public Works Building- Anchorage, Alaska, Andrew J. Bigalke Jun 2014

Comprehensive Fire And Life Safety Analysis- Moa Public Works Building- Anchorage, Alaska, Andrew J. Bigalke

Fire Protection Engineering: Culminating Experience Project Reports

This report is a Comprehensive Fire and Life Safety Analysis addressing both prescriptive and performance based engineering analysis of the MOA Public Works building located in the Municipality of Anchorage, Alaska. The Public Works building was originally built in 1997 under the code requirements of the Uniform Building Code, as a Type II-N building. An addition was constructed in 2002 using the International Building Code (IBC), 2000 Edition. A prescriptive analysis is performed using the requisite building code and standards currently adopted by the State of Alaska, and by the Municipality of Anchorage. The currently adopted building codes and standards …


Fire Protection And Life Safety Evaluation- Hinesville Cboc Va Clinic, Jeff Dew Jun 2014

Fire Protection And Life Safety Evaluation- Hinesville Cboc Va Clinic, Jeff Dew

Fire Protection Engineering: Culminating Experience Project Reports

The Hinesville MOB will be analyzed throughout the course of this report to determine if it meets the prescriptive-based requirements set forth by local and national regulating bodies. Further, a performance-based approach will be taken to assess the buildings ability to sustain life while a safe and timely evacuation occurs. It will be determined that the Hinesville MOB does comply with all regulations set forth for fire and life safety. In some cases its construction and systems may exceed the required minimum standards. It will contain 100% coverage with an automatic sprinkler system, be equipped with adequate emergency notification system, …


Fire And Life Safety Analysis- Cal Poly Recreation Center, Connor Mcgill Jun 2014

Fire And Life Safety Analysis- Cal Poly Recreation Center, Connor Mcgill

Fire Protection Engineering: Culminating Experience Project Reports

The purpose of this fire and life safety analysis is to determine whether Cal Poly’s Recreation Center meets fire safety goals. The primary fire safety goal is to provide building occupants with an environment that is tenable and allows for safe egress in the event of a fire, and reduce the likelihood of any catastrophic fire event. This goal can be achieved by protecting the occupants not intimate with the initial fire development and improving survivability of those occupants intimate with the initial fire development, NFPA 101, 2012. A prescriptive-based design approach and a performance-based design approach are used to …


Fire Protection And Life Safety Analysis- Dell Medical School Academic Building, David Gramlich Jun 2014

Fire Protection And Life Safety Analysis- Dell Medical School Academic Building, David Gramlich

Fire Protection Engineering: Culminating Experience Project Reports

This report is on the Dell Medical School Academic Building located in Austin, Texas. The life safety and prescriptive based code requirements are summarized within this report. It also includes conceptual fire protection and fire alarm system design. This report mentions University of Texas System Owner’s Design Guidelines that exceed the required code requirements. This report was developed when the building was in the Design Development stage. Since, code deficiencies have been addressed, and changes have been made to the building during the remainder of the design process, this report does not reflect the actual construction or protection strategies used …


Construction Warehouse, Ben Johnson Jun 2014

Construction Warehouse, Ben Johnson

Fire Protection Engineering: Culminating Experience Project Reports

The purpose of this report is to provide a comprehensive evaluation of the fire protection and life safety design of a warehouse building that serves a large construction project. The results and conclusions from this evaluation are documented herein and supported by analysis when necessary. The gross floor area per story of the construction warehouse is 39,000 ft2. This building is used as a warehousing facility in support of a large construction project. Rack storage of Group A plastics is permitted in this facility to a height of 20 ft. beneath a 24 ft. ceiling on the main floor. Shelf …


Orangeburg Assembly Hall Of Jehovah's Witnesses- Fire Protection And Life Safety Design Analysis, Justin B. Biller Mar 2014

Orangeburg Assembly Hall Of Jehovah's Witnesses- Fire Protection And Life Safety Design Analysis, Justin B. Biller

Fire Protection Engineering: Culminating Experience Project Reports

In partial fulfillment of the requirements for the Degree of Masters of Science in Fire Protection Engineering, a prescriptive and performance-based engineering analysis was performed on the Orangeburg Assembly Hall of Jehovah’s Witnesses. The building was recently constructed and completed in 2013 in Orangeburg, South Carolina to serve as a center for education of Jehovah’s Witnesses on Biblical principles for daily life. More than 300 congregations throughout Georgia and the Carolinas will use the Assembly Hall for their semi-annual assemblies and conventions, with an estimated annual attendance of 190,000 per year. Prescriptive analyses were conducted based primarily upon the provisions …


Fire Protection Life Safety Analysis- Bachelor Enlisted Quarters, Kyle C. Leadon Mar 2014

Fire Protection Life Safety Analysis- Bachelor Enlisted Quarters, Kyle C. Leadon

Fire Protection Engineering: Culminating Experience Project Reports

This Bachelor Enlisted Quarters (BEQ) shall be constructed, arranged, equipped, maintained, and operated in accordance with this report and applicable criteria to ensure a minimum level of life safety and property protection is provided from actual and potential fire hazards. The goal is to ensure the occupants are provided with an environment that is reasonably safe from fire. We accomplish this goal by protecting occupants not intimate with the initial fire development, and by improving the survivability of occupants intimate with the initial fire development. The protection described in this report takes on many forms, from active protection, such as …