Open Access. Powered by Scholars. Published by Universities.®
- Discipline
-
- Operations Research, Systems Engineering and Industrial Engineering (38)
- Industrial Engineering (29)
- Mechanical Engineering (25)
- Other Operations Research, Systems Engineering and Industrial Engineering (24)
- Systems Engineering (19)
-
- Manufacturing (12)
- Electrical and Computer Engineering (9)
- Computer Engineering (7)
- Other Mechanical Engineering (7)
- Applied Mechanics (6)
- Civil and Environmental Engineering (6)
- Heat Transfer, Combustion (6)
- Arts and Humanities (5)
- Electrical and Electronics (5)
- Operational Research (5)
- Aerospace Engineering (4)
- Architecture (4)
- Computer-Aided Engineering and Design (4)
- Construction Engineering and Management (4)
- Education (4)
- Electro-Mechanical Systems (4)
- Materials Science and Engineering (4)
- Risk Analysis (4)
- Social and Behavioral Sciences (4)
- Acoustics, Dynamics, and Controls (3)
- Biomedical Engineering and Bioengineering (3)
- Business (3)
- Construction Engineering (3)
- Keyword
-
- Performance Based Design (99)
- Fire Dynamics Simulator (FDS) (78)
- RSET (76)
- ASET (74)
- Life Safety Code (64)
-
- Performance-Based Design (29)
- Fire Dynamics Simulator (21)
- Life Safety (21)
- Pathfinder (20)
- Available Safe Egress Time (ASET) (18)
- Prescriptive Analysis (18)
- Egress (17)
- Required Safe Egress Time (RSET) (17)
- Fire Protection (14)
- Fire Alarm (12)
- Fire Dynamic Simulator (FDS) (12)
- Fire Modeling (11)
- Smoke Control (11)
- FDS (10)
- Fire Protection Engineering (10)
- Prescriptive Design (10)
- Building Code (9)
- Design (9)
- Fire Suppression (8)
- Fire and Life Safety Analysis (8)
- Performance Based Analysis (8)
- Prescriptive Based Design (8)
- Building Fire Protection (7)
- Design Fire (7)
- Life Safety Analysis (7)
- Publication Year
- Publication
-
- Fire Protection Engineering: Culminating Experience Project Reports (194)
- Industrial and Manufacturing Engineering (36)
- Master's Theses (18)
- Mechanical Engineering (12)
- Computer Science and Software Engineering (9)
-
- Biomedical Engineering (8)
- Liberal Arts and Engineering Studies (6)
- BioResource and Agricultural Engineering (5)
- General Engineering (4)
- Architectural Engineering (3)
- Computer Engineering (3)
- College of Engineering Summer Undergraduate Research Program (2)
- Construction Management (2)
- Industrial Technology and Packaging (2)
- Materials Engineering (2)
- STAR Program Research Presentations (2)
- Chemistry and Biochemistry (1)
- Electrical Engineering (1)
- Publication Type
Articles 91 - 120 of 310
Full-Text Articles in Other Engineering
Study Of Fragility Functions For Assessing Damage To Water Pipe Networks Caused By Earthquake Loading, Dylan Joseph Merlo
Study Of Fragility Functions For Assessing Damage To Water Pipe Networks Caused By Earthquake Loading, Dylan Joseph Merlo
Master's Theses
The performance of water lifelines during seismic events is an area of ongoing research. In this study we evaluate eight (8) different seismic events and the impact that ground shaking and ground deformations had on water pipeline systems. The overall goal of this work is to provide municipalities and utility providers with tools for mitigating the consequences of seismic hazards on water lifeline systems by analyzing the accuracy of damage estimation models. Three (3) different repair rate models are evaluated using data collected from the seismic events and compared to observed repair rate data. Results are analyzed to examine the …
Fire Protection And Life Safety Analysis Of A Chicago Hotel, Thomas Hampton
Fire Protection And Life Safety Analysis Of A Chicago Hotel, Thomas Hampton
Fire Protection Engineering: Culminating Experience Project Reports
The following report contains an analysis of the life safety and fire protection features of a Chicago Hotel. The report is intended to meet the requirements for the Culminating Experience of the Cal Poly Master of Science Fire Protection Engineering Program.
The Chicago Hotel building chosen for the analysis is a mixed-use 7-story hotel. On the 1st, 2nd, and 7th floors of the building are spaces for mercantile and restaurant tenants as well as other spaces necessary for the operation of the building such as back of house space for the hotel, storage, employee locker rooms, hotel and retail lobbies, …
Cal Poly Engineering Iv Building, Kai Liu
Cal Poly Engineering Iv Building, Kai Liu
Fire Protection Engineering: Culminating Experience Project Reports
This report analyzes the fire protection systems of Engineering IV building at California Polytechnic State University, San Luis Obispo. It is a cumulative project of the Fire Protection Engineering Program at Cal Poly. The report consists of a prescriptive analysis and a performance-based design analysis. The building contains dry laboratories, classrooms, offices, and administrative spaces. The building is a three-story structure. There is an atrium that connects the first floor to the third floor. However, the building has a horizontal enclosure to separate the connection between the second floor and the third floor.
The prescriptive analysis is based on the …
Elewexe – Building 172b, California Polytechnic State University – San Luis Obispo, Anna M. Santoro
Elewexe – Building 172b, California Polytechnic State University – San Luis Obispo, Anna M. Santoro
Fire Protection Engineering: Culminating Experience Project Reports
California Polytechnic State University at San Luis Obispo recently finished constructing a new multimillion student housing project on campus. One of the six buildings, elewexe or 172B, from this housing complex was selected for a full evaluation of the fire and life safety systems using both prescriptive and performance based approaches. The building is a Type II-B four story dormitory with an R-2 occupancy classification.
For the prescriptive approach, the building was evaluated against the most current editions of the IBC and relevant NFPA code editions for building requirements, sprinkler design and fire alarm and detection. When looking at the …
Second Baptist Church, Cypress Campus, David Kalinec
Second Baptist Church, Cypress Campus, David Kalinec
Fire Protection Engineering: Culminating Experience Project Reports
This report was created as part of the Master of Science Fire Protection Engineering degree program at California Polytechnic State University at San Luis Obispo. This project summarized the covered subjects during the course of each quarter of the program. The site chosen for this project is Second Baptist Church, Cypress Campus, located in Cypress, TX. This building was chosen because Churches are mixed use buildings that include assembly occupancies and large occupant loads.
A prescriptive-based code evaluation was performed on the building according to the 2012 editions of the international building code and fire code, adopted at the time …
Fire And Life Safety Analysis: Robert E Kennedy Library, Cal Poly San Luis Obispo Campus, Christopher Olmstead
Fire And Life Safety Analysis: Robert E Kennedy Library, Cal Poly San Luis Obispo Campus, Christopher Olmstead
Fire Protection Engineering: Culminating Experience Project Reports
This report provides a fire safety analysis on the Robert E. Kennedy Library located on the Cal Poly University campus San Luis Obispo, California. In the course of this analysis, a prescriptive and performance-based approached was used. The goal was to review and obtain an understanding of the features of the building’s design and use that provide fire safety. During the analysis, areas of deficiency will be identified. Recommendations will be made based on the analysis and the nature of the deficiencies.
The overall goal is to abide by the NPFA Life Safety standard: (1) Protection of occupants not intimate …
Fire And Life Safety Analysis: San Francisco Museum Of Modern Art, Jason Woo
Fire And Life Safety Analysis: San Francisco Museum Of Modern Art, Jason Woo
Fire Protection Engineering: Culminating Experience Project Reports
A fire and life safety analysis was conducted to fulfill a requirement for the Master of Science Degree in Fire Protection Engineering from California Polytechnic State University. A prescriptive and performance-based analysis was conducted on the San Francisco Museum of Modern Art. The SFMOMA is a 10-story, 460,000 𝑓𝑡2 , Type 1A mixed occupancy building. Located in the northwest corner of San Francisco, SFMOMA houses a collection of over 33,000 works of painting, sculpture, design and media making it one of the largest museums in the world for modern and contemporary art.
Four features of the prescriptive based analysis include: …
Research Laboratory: Fire, Explosion, And Life Safety Analysis, Dennis A. Tuma
Research Laboratory: Fire, Explosion, And Life Safety Analysis, Dennis A. Tuma
Fire Protection Engineering: Culminating Experience Project Reports
This culminating report is a fire, explosion, and life safety evaluation of a Research Laboratory ("Laboratory") where significant quantities of flammable, combustible, and hazardous materials are used and stored. The report's initial portion provides a prescriptive-based analysis using applicable sections of the 2016 California Building Standard Codes and National Fire Protection Association (NFPA) standards. Because of the unique challenges to hazardous laboratory spaces, the prescriptive- based analysis includes both a review of codes applicable to all occupancies (e.g., egress, fire-resistance, building area), and codes applicable to Group H and L occupancies (e.g., electrical area classification maps, control areas). Unfortunately, detailed …
Powell Building, David John Devinney
Powell Building, David John Devinney
Fire Protection Engineering: Culminating Experience Project Reports
A detailed study of the fire and life safety systems was performed on the Powell Building located in Oak Ridge, TN. This report consists of both prescriptive and performance-based analysis. The prescriptive based analysis reviews the fire and life safety requirements in accordance with the applicable codes. The prescriptive portion of this report included life safety, fire suppression systems, fire alarm and detection systems, and structural fire protection. The performance-based analysis was used with viable fire scenarios to ensure that occupants could safely egress the building. This was accomplished by comparing the Required Safe Egress Time (RSET) with the Available …
New Campus Life Center Fire Protection Evaluation, Shawn R. Block
New Campus Life Center Fire Protection Evaluation, Shawn R. Block
Fire Protection Engineering: Culminating Experience Project Reports
This project report is a fire and life safety evaluation of a newly constructed building. The new Campus Life Center (CLC) building is located on the campus of Emory University in Atlanta, Georgia. The CLC is a student center where students, staff, and guests can gather to socialize, study, eat and attend conferences. The prescriptive requirements were based on the Georgia State Fire Codes, adopted on January 2014 and served as code of record for this facility. Occupant classification was established from both International Building Code (IBC) and Life Safety Code (LSC), NFPA 101, to determine construction type, interior finish …
Residential Seismic Retrofit Cost For Home Located In Tustin, California, Sara Clark
Residential Seismic Retrofit Cost For Home Located In Tustin, California, Sara Clark
Construction Management
Seismically retrofitting a residential home not only protects the homeowner, but also helps them prepare for the future. Needless to say, many older homes are not up to the 2018 International Residential Code. As a result, many owners are uninformed about how much it will cost to retrofit their home and what changes will have to be made. The solution for this is determining a cost per square foot ratio that will help homeowners calculate an estimate for the retrofit of their home. Additionally, it is important to break this cost down into what specific changes need to be made. …
Building B: Fire And Life Safety Analysis, Joseph Radford Sellers
Building B: Fire And Life Safety Analysis, Joseph Radford Sellers
Fire Protection Engineering: Culminating Experience Project Reports
A fire and life safety analysis was performed on Building B at the Y-12 National Security Complex in Oak Ridge, TN. This report was completed as a fulfillment of one of the requirements for the Masters of Science in Fire Protection Engineering Program from the California Polytechnic State University (Cal Poly) in San Luis Obispo, CA. The analysis consisted of a prescriptive, or code-based analysis, and a performance-based analysis.
The prescriptive analysis composed of four main areas: Life Safety, Fire Alarm and Detection, Structural Fire Protection, and Fire Suppression. The prescriptive analysis was performed to determine if Building B is …
Military Maintenance Hangar, Eliot Jordan
Military Maintenance Hangar, Eliot Jordan
Fire Protection Engineering: Culminating Experience Project Reports
This report describes the building code compliance of a military aircraft hangar. The facility is evaluated for both prescriptive code compliance and for a performance-based compliance via the use of design fires analyzed with computer programs Fire Dynamics Simulator (FDS) and occupant egress analyzed with Pathfinder software as well as hand calculations utilizing Excel.
The prescriptive code analysis is done based upon a combination of Unified Facilities Criteria, International Building Code, and NFPA 101 codes and standards. Prescriptive compliance was checked against the building non separated occupancies of S-1 and B. The building was evaluated for building construction type IIB. …
Fire Protection Analysis: Engineering Iv, Building 192, Cal Poly State University, San Luis Obispo, Paul Jenkins
Fire Protection Analysis: Engineering Iv, Building 192, Cal Poly State University, San Luis Obispo, Paul Jenkins
Fire Protection Engineering: Culminating Experience Project Reports
This report is an analysis of the fire protection capabilities of Engineering IV (Building 192) at Cal Poly University in San Luis Obispo, CA. The overall objective of this report was to assess whether the building and its fire protection systems supported the evacuation of occupants from the building in a safe manner before conditions became untenable during a fire event. The assessment was accomplished by performing a prescriptive and performance analysis.
The purpose of the prescriptive analysis was to determine whether the building egress components and fire protections systems were designed, built, and installed in compliance with all the …
Raysun's Infrared Raisin Dryer, Lucas Kensinger, Saraith Aispuro, Joe Vanacore
Raysun's Infrared Raisin Dryer, Lucas Kensinger, Saraith Aispuro, Joe Vanacore
General Engineering
The RaySuns senior project team was tasked with lowering the drying costs of raisins for River Ranch Raisins. In doing so, we explored several options for cutting costs: utilizing automation and exploring new drying technologies were our primary focus. We eventually planned a modular infrared heating mechanism which would be easy to automate in future projects. After manufacturing and testing an infrared heating mechanism, it was found that infrared drying could significantly cut costs versus the previous natural gas fired dryer tunnels while leaving room for automation. The infrared dryer was also shown to have the potential to create high-quality …
Culminating Course Progress Report For The Na893 Community Support Center, Yokosuka Naval Base, Japan, Kazuo Miura
Culminating Course Progress Report For The Na893 Community Support Center, Yokosuka Naval Base, Japan, Kazuo Miura
Fire Protection Engineering: Culminating Experience Project Reports
This is the culminating project report for the Fire Project Engineering Master’s of Science at California Polytechnic at San Luis Obispo. This project will consider a project for the US military in Japan, JFY893 Community Support Facility, Yokosuka Naval Base. The subject facility consists of a library, education center, family services, and other community services. The Library shall serve as the Main Base Library, keep and store books and provide library services for active duty population, dependents and retirees. The Education Center provides services for advancing of the academic, technical, and vocational education of military personnel of all grades and …
New Stanford Hospital, Fpe 2020 Student
New Stanford Hospital, Fpe 2020 Student
Fire Protection Engineering: Culminating Experience Project Reports
This report is the compiled culminating project for the Fire Protection Engineering Master’s Program at Cal Poly, SLO. Addressed herein is the fire protection and life safety approach for the New Stanford Hospital in Palo Alto, California in accordance with the 2012 NFPA 101 – Life Safety Code and the 2016 California Building and Fire Codes. This includes review of building occupancies, construction type, fire-resistive ratings, means of egress, and fire protection systems. The objective of this report is to review the impact of major fire scenarios on life, property, and operations.
The New Stanford Hospital is a Type IA …
Dynamic Procedural Music Generation From Npc Attributes, Megan E. Washburn
Dynamic Procedural Music Generation From Npc Attributes, Megan E. Washburn
Master's Theses
Procedural content generation for video games (PCGG) has seen a steep increase in the past decade, aiming to foster emergent gameplay as well as to address the challenge of producing large amounts of engaging content quickly. Most work in PCGG has been focused on generating art and assets such as levels, textures, and models, or on narrative design to generate storylines and progression paths. Given the difficulty of generating harmonically pleasing and interesting music, procedural music generation for games (PMGG) has not seen as much attention during this time.
Music in video games is essential for establishing developers' intended mood …
Mad Jack Alpine Touring Model Design, Austin Gasbarra, Gillian Stargensky, Madeleine Mccool, Brannon Smudz
Mad Jack Alpine Touring Model Design, Austin Gasbarra, Gillian Stargensky, Madeleine Mccool, Brannon Smudz
Mechanical Engineering
Skiing is a sport enjoyed by millions of people every year, yet ski boots are very uncomfortable and cost- prohibitive, resulting in a low conversion rate of first-time skiers to lifetime skiers. Additionally, Alpine Touring (AT) is seeing a surge in popularity as ski resorts become more expensive, but few companies are developing affordable products in this realm. Mad Jack Snow Sports has developed a product that they believe addresses some of the main issues associated with skiing, but they want to develop their product line further. The problem statement and scope state that the purpose of this project is …
Fire Protection System Analysis Of Warren J. Baker Center Of Science And Mathematics, Jacob Dentici
Fire Protection System Analysis Of Warren J. Baker Center Of Science And Mathematics, Jacob Dentici
Fire Protection Engineering: Culminating Experience Project Reports
This report analyzes the different fire protection systems and features of the Warren J. Baker Center for Science and Mathematics at the California Polytechnic State University, San Luis Obispo campus. This building is used for lectures, laboratories, study spaces, faculty spaces, and storage spaces for the students and faculty at the Cal Poly campus. Typically, there are science and math courses taught within this building. The building is a 6-story structure, that is not classified as a high-rise due to the location of fire department access and has a five-story atrium located on levels 2 through 6. There are two …
Gaslamp Hotel-Fire Protection/Life Safety Analysis, Garner A. Palenske
Gaslamp Hotel-Fire Protection/Life Safety Analysis, Garner A. Palenske
Fire Protection Engineering: Culminating Experience Project Reports
The Gaslamp Hotel was analyzed for fire protection/life safety using two different methodologies; a prescriptive approach and a performance-based approach. Both considered the same features of the building. The prescriptive analyses studied the variation of the building’s fire protection/life safety components from those required by the applicable codes and standards. This included building construction, fire resistance, fire suppression, fire detection, smoke control system, and egress systems. The results of the analysis indicate that the building complies with the requirements of the applicable codes and standards, with three exceptions relating to occupant egress: 1) The first-floor bar area: One exit is …
Silverton Timeshare Tower “The Berkley”, Kevin Murphy
Silverton Timeshare Tower “The Berkley”, Kevin Murphy
Fire Protection Engineering: Culminating Experience Project Reports
The Berkley (aka the Silverton Timeshare Tower) was reviewed for compliance with the code of record. This included review of the full architectural set of drawings, as well as the available Fire Protection Report and Amendments that were issued prior to and during construction. This analysis has been slowly performed throughout the extent of my graduate career at California Polytechnic State University, San Luis Obispo (Cal Poly), and has been in depth for each applicable area of study. Each of the studies performed will be reviewed in the applicable sections below, be it for prescriptive analysis of the existing facility …
Cal Poly State University Robert E. Kennedy Library Fire Protection Analysis Report, Timothy Anderson
Cal Poly State University Robert E. Kennedy Library Fire Protection Analysis Report, Timothy Anderson
Fire Protection Engineering: Culminating Experience Project Reports
This report determines whether or not the fire protection and life safety features of Robert E. Kennedy Library are consistent with the fire protection objectives established in nationally recognized fire protection codes and standards. This analysis is performed to establish a technical baseline for identification of fire protection deficiencies.
Kennedy Library is the campus student library at California Polytechnic State University. The facility provides resources and services in a variety of media to meet the needs of university students and faculty.
This analysis consists of a prescriptive analysis and a performance-based analysis. The prescriptive analysis is an analysis of the …
Building V: Fire And Life Safety Analysis, Andrew Ko
Building V: Fire And Life Safety Analysis, Andrew Ko
Fire Protection Engineering: Culminating Experience Project Reports
A fire and life safety analysis was completed for Building V as part of a culminating project in the California Polytechnic State University at San Luis Obispo Fire Protection Engineering Master’s Degree Program. This report will detail both a prescriptive design based on the 2013 California Building Code and applicable standards as well as a performance based analysis based on a design fire scenario.
The prescriptive design will discuss four main components of compliance: 1) Structural Fire Protection, 2) Fire Alarm, 3) Fire Sprinkler, and 4) Means of Egress. Structural fire protection analysis is separated into four parts: type of …
Fire Protection Engineering Final Report: Baylor Scott & White Medical Center, College Town, Tx, Jonathan Lo
Fire Protection Engineering Final Report: Baylor Scott & White Medical Center, College Town, Tx, Jonathan Lo
Fire Protection Engineering: Culminating Experience Project Reports
This report examines the Baylor, Scott & White Medical Center in College Station, TX. This hospital is a 324,070 square feet midrise building of Type I-A construction and Group I-2 occupancy, with a basement and five above-grade floors. Publicly-available, simplified floor plans were obtained from the internet, and a prescriptive- and performance-based analysis was formed around these plans. It should be noted that these online plans may not contain all information and details in that are found in architectural plans, and that assumptions were made in order to ‘fill in the gaps’ and proceed with this report. For example, on …
Atx Storage: Fire And Life Safety Analysis, Perla Salcedo
Atx Storage: Fire And Life Safety Analysis, Perla Salcedo
Fire Protection Engineering: Culminating Experience Project Reports
The following report is a fire and hazard protection analysis of a new building. This new building is a self-storage building called ATX Storage locate in Austin, TX. The prescriptive requirements set by the codes and standards used at time of construction of the building have been met. The building has been properly classified with respect to occupancy as S1, Group B and R-3 and construction type II A Sprinklered. Appropriate design for interior partitions and exterior wall have been identified. Interior finish requirements have been analyzed for a better understanding of aesthetics guidelines. Based on the sprinkler drawing calculations, …
The Spheres, Justin Milne
The Spheres, Justin Milne
Fire Protection Engineering: Culminating Experience Project Reports
The Spheres, an architectural masterpiece surrounded by a high-rise building complex, is in the heart of South Lake Union in Seattle, Washington. The Spheres building pushes limitations in building design on all levels. With hexecontahedron panels tessellated over the façade of its three spherical glass glaze greenhouse globes, the design affords futuristic personality, alongside energy efficacy while sustaining life within the building. While building innovations within The Spheres are certainly notable within all disciplines of Architecture, Engineering, and Construction, the contents of this report refer to fire protection engineering and code consulting elements.
In meeting The Spheres' required fire safety …
A Fire Protection Analysis Of Kipp Academy Of Opportunity, Shahrzad Alaei
A Fire Protection Analysis Of Kipp Academy Of Opportunity, Shahrzad Alaei
Fire Protection Engineering: Culminating Experience Project Reports
The purpose of this report is to analyze and assess the life safety and fire protections systems of the KIPP Academy of Opportunity (KAO) charter school located in South Los Angeles. KAO is a 3-story building with a total area of 27,429 ft2 that was originally built in 2003 to serve 400 students.
Two separate fire and life safety assessments were performed in this project to ensure the building meets the requirements by the building code and fire safety standards. The prescriptive based analysis includes assessment of structural design, construction materials, egress design, fire alarm, communication system, fire suppression system, …
Fire And Life Safety Analysis: Building 171a – Poly Canyon Village, Delaney Seeburger
Fire And Life Safety Analysis: Building 171a – Poly Canyon Village, Delaney Seeburger
Fire Protection Engineering: Culminating Experience Project Reports
A fire and life safety analysis was performed in fulfillment of one of the requirements for the Master of Science Degree in Fire Protection Engineering from California Polytechnic State University San Luis Obispo (Cal Poly). The analysis consisted of a prescriptive and a performance-based analysis. These analyses were performed on Building 171A which is part of the Cal Poly San Luis Obispo campus. The prescriptive analysis consisted of four distinct areas of focus: 1) Structural Fire Protection, 2) Water-Based Suppression Systems, 3) Fire Alarm and Detection Systems, 4) Egress Analysis and Design Prescriptive analyses are performed to determine whether a …
A Fire Protection Life Safety Analysis Of Permian Oil Plaza, Nick Francis
A Fire Protection Life Safety Analysis Of Permian Oil Plaza, Nick Francis
Fire Protection Engineering: Culminating Experience Project Reports
The Permian Oil Plaza (POP) is a four story building located in Midland, TX. This facility was designed to provide over 200,000 square feet of office space to approximately 500 employees. The building was constructed of unprotected non-combustible (Type II-B) building materials and was completed in late 2015. An assessment of the building’s fire and life safety systems was performed to ensure these systems were designed and installed in a manner that meets, or exceeds, the intent of pertinent building codes and fire safety standards. This assessment included a prescriptive based analysis, as well as a performance-based analysis. The prescriptive …