Open Access. Powered by Scholars. Published by Universities.®
- Discipline
-
- Operations Research, Systems Engineering and Industrial Engineering (38)
- Industrial Engineering (29)
- Mechanical Engineering (25)
- Other Operations Research, Systems Engineering and Industrial Engineering (24)
- Systems Engineering (19)
-
- Manufacturing (12)
- Electrical and Computer Engineering (9)
- Computer Engineering (7)
- Other Mechanical Engineering (7)
- Applied Mechanics (6)
- Civil and Environmental Engineering (6)
- Heat Transfer, Combustion (6)
- Arts and Humanities (5)
- Electrical and Electronics (5)
- Operational Research (5)
- Aerospace Engineering (4)
- Architecture (4)
- Computer-Aided Engineering and Design (4)
- Construction Engineering and Management (4)
- Education (4)
- Electro-Mechanical Systems (4)
- Materials Science and Engineering (4)
- Risk Analysis (4)
- Social and Behavioral Sciences (4)
- Acoustics, Dynamics, and Controls (3)
- Biomedical Engineering and Bioengineering (3)
- Business (3)
- Construction Engineering (3)
- Keyword
-
- Performance Based Design (99)
- Fire Dynamics Simulator (FDS) (78)
- RSET (76)
- ASET (74)
- Life Safety Code (64)
-
- Performance-Based Design (29)
- Fire Dynamics Simulator (21)
- Life Safety (21)
- Pathfinder (20)
- Available Safe Egress Time (ASET) (18)
- Prescriptive Analysis (18)
- Egress (17)
- Required Safe Egress Time (RSET) (17)
- Fire Protection (14)
- Fire Alarm (12)
- Fire Dynamic Simulator (FDS) (12)
- Fire Modeling (11)
- Smoke Control (11)
- FDS (10)
- Fire Protection Engineering (10)
- Prescriptive Design (10)
- Building Code (9)
- Design (9)
- Fire Suppression (8)
- Fire and Life Safety Analysis (8)
- Performance Based Analysis (8)
- Prescriptive Based Design (8)
- Building Fire Protection (7)
- Design Fire (7)
- Life Safety Analysis (7)
- Publication Year
- Publication
-
- Fire Protection Engineering: Culminating Experience Project Reports (194)
- Industrial and Manufacturing Engineering (36)
- Master's Theses (18)
- Mechanical Engineering (12)
- Computer Science and Software Engineering (9)
-
- Biomedical Engineering (8)
- Liberal Arts and Engineering Studies (6)
- BioResource and Agricultural Engineering (5)
- General Engineering (4)
- Architectural Engineering (3)
- Computer Engineering (3)
- College of Engineering Summer Undergraduate Research Program (2)
- Construction Management (2)
- Industrial Technology and Packaging (2)
- Materials Engineering (2)
- STAR Program Research Presentations (2)
- Chemistry and Biochemistry (1)
- Electrical Engineering (1)
- Publication Type
Articles 121 - 150 of 310
Full-Text Articles in Other Engineering
Effect Of Aerogel On The Thermal Performance Of Corrugated Composite Sandwich Structures, Jacob Dillon Chess
Effect Of Aerogel On The Thermal Performance Of Corrugated Composite Sandwich Structures, Jacob Dillon Chess
Master's Theses
Current insulation solutions across multiple industries, especially the commercial sector, can be bulky and ineffective when considering their volume. Aerogels are excellent insulators, exhibiting low thermal conductivities and low densities with a porosity of around 95%. Such characteristics make aerogels effective in decreasing conductive heat transfer within a solid. These requirements are crucial for aerospace and spaceflight applications, where sensitive components exist among extreme temperature environments. When implemented into insulation applications, aerogel can perform better than existing technology while using less material, which limits the amount of volume allocated for insulation. The application of these materials into composites can result …
Prescriptive And Performance Analysis Of Cold Machine Shop, John Kline
Prescriptive And Performance Analysis Of Cold Machine Shop, John Kline
Fire Protection Engineering: Culminating Experience Project Reports
The purpose of this report is to analyze the fire and life safety aspects of the Cold Machine Shop located on the central coast of California. This report includes both a prescriptive and performance based analysis.
The prescriptive analysis will evaluate the building as follows, to ensure compliance with standard codes: 1)Egress analysis and design using NFPA 101, "Life Safety Code", 2)Fire detection, alarms, and communication systems using NFPA 72, "National Fire Alarm and Signaling Code", 3)Water-based fire suppression systems using NFPA 13, " Standard for Installation of Sprinkler Systems" and NFPA 14, " Standard for the Installation of Standpipe …
An Analysis Of The Life Safety And Fire Protection Features Of A New Hotel On California’S Central Coast, James Henahan
An Analysis Of The Life Safety And Fire Protection Features Of A New Hotel On California’S Central Coast, James Henahan
Fire Protection Engineering: Culminating Experience Project Reports
This report examines the fire protection and life safety features of a new, 3-story plus basement, hotel on California’s Central Coast. These features are examined from both a prescriptive, code-driven perspective, as well as from a performance-based design point of view.
The prescriptive analysis includes exit configuration and capacity, the NFPA 13 sprinkler system, the NFPA 72 fire alarm system, and the building construction types. All were found to be acceptable when compared against the applicable codes the building is subject to, with the exception of some of the load- bearing exterior walls.
The performance-based component examines the affect two …
University Student Services Center, Ivan Orlando Mendoza
University Student Services Center, Ivan Orlando Mendoza
Fire Protection Engineering: Culminating Experience Project Reports
The building was found to be generally compliant with the requirements set forth in the codes and standards, any discrepancies are addressed within the report in their respective sections. The prescriptive-based analysis was performed using the appropriate NFPA standards, the Life Safety Code (LSC) and the International Building Code (IBC).
The building is three storied and has an overall gross floor area of 101,579 sq ft. It is classified as a mixed occupancy use with a calculated total occupant load of 2,866 occupants and is being evaluated as a Type II-B structure as defined in the IBC. It is protected …
Bipartite Graph Packing Problems, Collin Christopher Wong
Bipartite Graph Packing Problems, Collin Christopher Wong
Computer Science and Software Engineering
The overarching problem of this project was trying to find the maximal number of disjoint subgraphs of a certain type we can pack into any graph. These disjoint graphs could be of any type in the original problem. However, they were limited to be T2 trees for my research (T2 trees are defined in section 2.1 of the paper). In addition, most of my work was focused on packing these T2 trees into constrained bipartite graphs (also defined in section 2.1 of the paper).
Even with these specific constraints applied to the overall problem, the project still …
Chrome Extension To Explore Modular Homepage, Griffin T. Cloonan, Landon E. Woollard, Nick A. Ponce
Chrome Extension To Explore Modular Homepage, Griffin T. Cloonan, Landon E. Woollard, Nick A. Ponce
Computer Science and Software Engineering
This was an exploratory project, intended to develop skills developing extension based web applications. We spent our time building a modular, customizable homepage extension for google chrome. The bulk of our work was focused towards structure and function, as a result, the project is not highly appealing visually. We worked with foreign concepts in a foreign environment in an attempt to learn new skills on the fly.
Next Generation Protocol: Innovating A Resilient Future, Andrew Steven Rudnick, Jamie Cannady, Joe Decesaro, Juan A. Ortiz Salazar
Next Generation Protocol: Innovating A Resilient Future, Andrew Steven Rudnick, Jamie Cannady, Joe Decesaro, Juan A. Ortiz Salazar
Materials Engineering
Conventional practices do not account for product life beyond end-of-sale – these practices are not sustainable. We have developed an end-of-life protocol that includes a metric that we call the Recovery Rating. The objectives of this Next Generation Protocol, beyond supporting the United Nations’ Sustainable Development Goals, are to encourage the production of goods designed for recovery and to promote the collaboration between consumers, the public, and the private sector to recover goods at their end-of-life. The Recovery Rating that we propose evaluates and quantifies recovery potential of products. The Recovery Rating, which is normed against embodied energy from the …
Shyh Wang Hall- Lbnl Building 59, Mike Torkelson
Shyh Wang Hall- Lbnl Building 59, Mike Torkelson
Fire Protection Engineering: Culminating Experience Project Reports
This report details the fire and life safety analysis of Shyh Wang Hall, a new building at the Lawrence Berkeley National Laboratory. Wang Hall houses offices, high performance computers, and associated mechanical space. The building is constructed as a Type IIB structure and includes four stories. Both prescriptive-based and performance-based design is considered.
The prescriptive analysis considers the fire and life safety features as required by applicable codes, including the Department of Energy requirements. The building is protected by fire detection and alarm system as well as automatic sprinklers. The prescriptive design meets the code requirements with the possible exception …
Life Safety And Fire Analysis - Aircraft Hangar, Frederick J. Tanis Jr.
Life Safety And Fire Analysis - Aircraft Hangar, Frederick J. Tanis Jr.
Fire Protection Engineering: Culminating Experience Project Reports
A hangar originally built in 1958 then modified and expanded over the years was evaluated using both the prescriptive requirements and a performance analysis. For the prescriptive analysis the building was evaluated against the 2015 International Building Code and the current NFPA codes and in a few cases the Department of Defense (DoD) Unified Facilities Criteria (UFC). During the prescriptive analysis a few areas were identified that do not meet the current codes due to areas being broken up into separate rooms and hallways and rooms being separated by security doors that only allow unobstructed travel in one direction. These …
Warren J. Baker Center For Science And Mathematics (Csm)- Fire Protection Analysis, Neal Larsen
Warren J. Baker Center For Science And Mathematics (Csm)- Fire Protection Analysis, Neal Larsen
Fire Protection Engineering: Culminating Experience Project Reports
Analyzing the fire protection features of the Warren J. Baker Center for Science and Mathematics Building 180, located on Cal Poly Campus in San Luis Obispo California was done using two methods. The prescriptive based analysis of the building focused on the building design, egress, structural fire protection, fire suppression, fire alarm and detection systems to determine if current codes and standards were meet. The performance based analysis discusses certain methods and design fire scenarios that are present within the building and the building’s ability to protect occupants until they can exit safely. The performance based analysis was done using …
General Purpose Laboratory Building 33- Lawrence Berkeley National Laboratory, Nicholas Tran
General Purpose Laboratory Building 33- Lawrence Berkeley National Laboratory, Nicholas Tran
Fire Protection Engineering: Culminating Experience Project Reports
A detailed study of the fire and life safety systems in the General Purpose Laboratory at the Lawrence Berkeley National Laboratory was performed. The prescriptive and performance-based methods for fire and life safety requirements were analyzed in accordance with the applicable codes. The prescriptive items examined included the egress capacities, fire suppression systems, fire detection and notification systems, and structural construction requirements. The performance-based models utilized studied fire growth and its impact on the fire suppression systems as well as time to egress for the occupants. The General Purpose Laboratory was found to be compliant with the prescriptive requirements in …
Fire Protection And Life Safety Analysis- Building 192 – Engineering Iv, Donald Joseph Wood
Fire Protection And Life Safety Analysis- Building 192 – Engineering Iv, Donald Joseph Wood
Fire Protection Engineering: Culminating Experience Project Reports
A Fire Protection and Life Safety Analysis has been performed on California Polytechnic State University Building 192 – Engineering IV as part of a culminating project in the Masters of Science in Fire Protection Engineering program at California Polytechnic State University. This analysis consists of a prescriptive analysis based on current codes and standards as well as a performance-based analysis.
A prescriptive analysis evaluates compliance with modern codes and standards and consists of the following five parts: 1)Egress Design and Analysis, 2)Structural Fire Protection, 3)Water-based Fire Suppression, 4)Fire Detection and Alarm Systems, and 5)Smoke Control Systems
The purpose of the …
Fire And Life Safety Analysis- College Campus Building, Jacob Ludeman
Fire And Life Safety Analysis- College Campus Building, Jacob Ludeman
Fire Protection Engineering: Culminating Experience Project Reports
A Fire and Life Safety Analysis was performed as an academic exercise as part of the MS Fire Protection Engineering Program of California Polytechnic State University, San Luis Obispo. The project is a culminating report with regards to prescriptive based and performance based aspects for the fire and life safety analysis of a project building. These analyses were performed on a building located on a college campus in Southern California and is to remain nameless upon the request of the owner and architect. The building is in the School of Physical Sciences at the University it resides. The building houses …
Construction Innovation Center- Fire And Life Safety Analysis, Matthew Atwell
Construction Innovation Center- Fire And Life Safety Analysis, Matthew Atwell
Fire Protection Engineering: Culminating Experience Project Reports
In this report you will find the analysis of existing fire protection systems and features that are installed in the Construction Innovation Center at California Polytechnic State University, San Luis Obispo. The Buildings construction was completed in 2008 and is separated into three separate buildings A, B, and C connected by an exterior balcony. This report is separated into two separate analysis Prescriptive and Performance.
The Prescriptive analysis reviews the buildings means of egress, fire alarm systems, the suppression systems, and the structural fire protection. The Prescriptive-based analysis of the Construction Innovation Center confirms that the building meets the requirements …
Building 43: Recreation Center - Cal Poly San Luis Obispo, Daniel Gonzalez
Building 43: Recreation Center - Cal Poly San Luis Obispo, Daniel Gonzalez
Fire Protection Engineering: Culminating Experience Project Reports
The purpose of this project is to analyze the Fire Protection systems of the Recreation Center on campus at California Polytechnic State University, San Luis Obispo. Only the building itself is analyzed in this project. This report provides both a prescriptive-based and performance-based analysis of the building. The prescriptive-based analysis includes an overview of the structural components and their fire resistance, the sprinkler system, the fire alarm system, as well as an egress analysis. The performance-based analysis consists of three different potential fire scenarios, with the first being modeled with both Pathfinder and Pyrosim. Resources used are the building’s floor …
Beauchemin Residence, Hannah E. Rogers
Beauchemin Residence, Hannah E. Rogers
Architectural Engineering
The following report details the structural engineering completed on the Beauchemin Residence, as well as the associated drawings, details, and special considerations. The Beauchemin Residence is an existing single story wood frame building on raised wood floor, located in the city of San Clemente. The scope of work includes calculations for a new roof, new walls (gravity & lateral), retrofit of the existing foundation, new foundation, and providing calculations. The process and progression of the structural design is documented, and correlated to the final product in the Appendix A & B.
Astrobee: Air Sampling Device And Zero Robotics Game, Bryce Van Ross
Astrobee: Air Sampling Device And Zero Robotics Game, Bryce Van Ross
STAR Program Research Presentations
Astrobee is a free-flying, 1'x1'x1' cuboid robot that is planned to be onboard the International Space Station (ISS) by February 2019. Astrobee will be the successor of the current ISS free-flyer, SPHERES. Free-flying robots possess a range of potential. They can facilitate work for astronauts aboard the ISS by performing rudimentary tasks and housekeeping (e.g., record-keeping, sensor analysis, etc.) efficiently. Free-flyers also act as innovative testbeds for guest scientists to perform zero-gravity control theory research. In recent years, SPHERES has hosted annual Zero Robotics (ZR) programming competitions in collaboration with MIT, challenging middle and high school students to write code …
Fire And Life Safety Analysis Of The Production Facility (Pf)- 870, Nolan Baker
Fire And Life Safety Analysis Of The Production Facility (Pf)- 870, Nolan Baker
Fire Protection Engineering: Culminating Experience Project Reports
The purpose of the fire and life-safety analysis was to perform a prescriptive-based and performance based analysis on the fire and life safety systems in the Production Facility (PF) at Sandia National Laboratories (SNL). The prescriptive-based analysis determined if the building met applicable code requirements for existing life safety systems. The performance-based analysis consisted of a series of fire scenarios to ensure the fire and life safety systems allowed adequate egress time for occupants in the event of a fire. The prescriptive-based analysis was based on the Life Safety Code (LSC) and the International Building Code (IBC). The occupancy of …
Sandia National Laboratories' Building 858/North Fabrication Facility, Daniel Garcia
Sandia National Laboratories' Building 858/North Fabrication Facility, Daniel Garcia
Fire Protection Engineering: Culminating Experience Project Reports
In this report, a fire protection and fire hazard analysis has been performed on a semi- conductor facility, abbreviated as the Fab, located on Kirtland Air Force Base in Albuquerque, New Mexico. The Fab is part of the MESA complex which is operated by the NTESS Corporation for the Department of Energy (DOE) at Sandia National Laboratories. The prescriptive analysis of this report addresses the various fire protection systems in the facility such as fire suppression, and fire alarm. The prescriptive analysis is based on national codes and standards from the National Fire Protection Association (NFPA) and from the International …
Pubwc Bathroom Review App, Clay Jacobs
Pubwc Bathroom Review App, Clay Jacobs
Computer Science and Software Engineering
For my senior project, I developed an iOS application to allow users to find, rate, and review nearby public restrooms. The app takes advantage of crowdsourced data to collect bathroom and review information. I also created a REST API to interface with the backend database that could be used to port the application to other platforms.
Dci Data Center Building- Fire Protection Analysis, Bryan Hathaway
Dci Data Center Building- Fire Protection Analysis, Bryan Hathaway
Fire Protection Engineering: Culminating Experience Project Reports
A fire protection analysis utilizing prescriptive and performance based design was performed for the existing building (DCIB) located in Minnesota. A new tenant is investigating converting the DCIB from a building used for data center, to an office building which will utilize an open office concept.
A prescriptive analysis of the building was performed to determine the life safety, fire suppression, fire alarm and structural requirements to ensure compliance with current applicable codes and standards. The prescriptive requirements are outlined and reviewed in Section 1 through Section 5 of this analysis. Modifications to the DCIB are required to achieve the …
Woodward Willis Building- Fire And Life Safety Evaluation, Jordan Nerat
Woodward Willis Building- Fire And Life Safety Evaluation, Jordan Nerat
Fire Protection Engineering: Culminating Experience Project Reports
This project report is an academic exercise, completed as part of the MS Fire Protection Engineering program at California Polytechnic State University. This project is a culminating report with regards to life safety analysis of the Woodward Willis Building located in Detroit Michigan, which utilizes the fundamental and applied courses of the fire protection engineering program.
The analysis is based on a prescriptive analysis of the building and its features, and also a performance analysis which entails the life safety aspect of the building. The analysis of the building is performed in accordance with NFPA 101 Life Safety Code 2015 …
Taft Community College- New Student Center- Fire And Life Safety Analysis, Matthew Winston
Taft Community College- New Student Center- Fire And Life Safety Analysis, Matthew Winston
Fire Protection Engineering: Culminating Experience Project Reports
The following report is a fire and life safety investigation into a new facility. The planned facility is a new Student Center at Taft Community College. The prescriptive requirements as set forth by the most up to date codes and standards chosen for the project are met. The building has been properly classified with respect to occupancy and construction type. Appropriate design for interior partitions and exterior walls have been identified. Interior finish requirements are elaborated so that adherence to these guidelines is made clear. The fire sprinkler system has an adequate supply of water from the municipal water supply …
Child Development Center- Fire Protection Analysis, Tyler Ball
Child Development Center- Fire Protection Analysis, Tyler Ball
Fire Protection Engineering: Culminating Experience Project Reports
This report contains two separate forms of analysis, Prescriptive-Based Analysis and Performance-Base Analysis. The Prescriptive Analysis discusses an overview of the building and its features whereas the Performance-Based Analysis discusses the building meeting applicable codes and standards as discussed in NFPA 101 Life Safety Code 2012 Edition, Unified Facilities Code (UFC), International Building Code (IBC) 2012 Edition, and the SFPE Handbook of Fire Protection Engineering. The Child Development Center (CDC) was analyzed as a new construction building. There are also noted assumptions within the report where necessary information about the building could not be obtained due to information restrictions from …
Warren J. Baker Center For Science Building Review, John Pagliero
Warren J. Baker Center For Science Building Review, John Pagliero
Fire Protection Engineering: Culminating Experience Project Reports
This report is a focused review and discussion of the life safety and fire protection design of Cal Poly Building 180: The Warren J. Baker Center for Science in partial fulfillment for the requirements of a Master’s of Science degree in Fire Protection Engineering at Cal Poly, San Luis Obispo. The report focuses on discussion areas specific to the curriculum of the Cal Poly Fire Protection Master’s program, including analysis of egress, structural fire protection, detection, alarm and automatic protection designs in comparison to current and effective codes and standards. This report also includes a, performance based, tenability analysis for …
Los Angeles Air Force Base Fitness Center, Colin White
Los Angeles Air Force Base Fitness Center, Colin White
Fire Protection Engineering: Culminating Experience Project Reports
The purpose of this report is to evaluate the life safety features of the Los Angeles Air Force Base Fitness Center, located on Los Angeles Air Force Base in El Segundo, California. This report is produced in partial fulfillment of the requirements of a Master’s of Science in Fire Protection Engineering from the Fire Protection Engineering Program at California Polytechnic State University’s San Luis Obispo Campus. This analysis approaches life safety in the fitness center from two angles. First, a prescriptive approach is used to evaluate the building’s compliance with current codes and standards that govern construction and maintenance of …
Maumus Center- Fire Protection Engineering Analysis, Tyler Mobley
Maumus Center- Fire Protection Engineering Analysis, Tyler Mobley
Fire Protection Engineering: Culminating Experience Project Reports
This report is a fire protection engineering analysis of the Maumus Center, a science center and planetarium, in Arabi, Louisiana. The objective of this analysis is to outline the code defined requirements and to confirm the minimum level of safety from fire is attained. Analyzed in the report are the design requirements prescribed in the adopted building and life safety codes, and the performance of the prescribed design. The prescriptive review addresses the building construction in regards to fire protection, the means of egress, the water‐based fire suppression system, and the fire alarm system. The performance review incorporates the goals …
Recreation Center- Cal Poly- Fire And Life Safety Analysis, Hao Yan
Recreation Center- Cal Poly- Fire And Life Safety Analysis, Hao Yan
Fire Protection Engineering: Culminating Experience Project Reports
This report discusses the fire and life safety analysis of the existing fire protection features installed in the Recreation Center building on the California Polytechnic State University. The analysis is conducted using two different approaches, the prescriptive analysis of the building and the performance-based design analysis.
The prescriptive analysis approach will examine installed fire protection features and systems in accordance with the International Building Code, such as structural fire protection, water-based suppression system, alarm and detection system, egress system, smoke control, and fire safety management plan. The egress system failed when the old gym area was used as a fixed …
Acme Semiconductor Foundry- Fab Expansion- Fire Protection Engineering Analysis Report, Jacob Epstein
Acme Semiconductor Foundry- Fab Expansion- Fire Protection Engineering Analysis Report, Jacob Epstein
Fire Protection Engineering: Culminating Experience Project Reports
The ACME Semiconductor Foundry – Fab Expansion is a new four story addition to an existing four story foundry facility. The Fab Expansion is approximately 154,500 square feet in footprint area that is connected to an existing four-story Fab Building. This report has been prepared to identify the building’s fire protection and life safety features that must be provided in accordance with the applicable codes and standards. The ACME Semiconductor Fab Expansion will contain multiple separated uses and will be required to be constructed with Type I-B construction. Building Construction Documents are provided in Appendix A showing compliance with the …
Orfalea College Of Business- Fire & Life Safety Analysis, Napoleon E. Nino
Orfalea College Of Business- Fire & Life Safety Analysis, Napoleon E. Nino
Fire Protection Engineering: Culminating Experience Project Reports
This report details the prescriptive and performance based analyses performed on the Orfalea College of Business building, located on the Cal Poly San Luis Obispo campus. Designed in accordance with the 1985 Uniform Building Code (UBC), this building is evaluated for compliance with the requirements prescribed under relevant codes in place as of 2016. The main function of this building is to serve both academic and administrative purposes, including classrooms and staff offices. Aspects of the building analyzed include: Egress Systems, Structural Fire Protection, Smoke Management, Fire Detection, Fire Notification, and Fire Suppression The prescriptive analysis demonstrates the lack of …