Open Access. Powered by Scholars. Published by Universities.®
- Discipline
-
- Operations Research, Systems Engineering and Industrial Engineering (38)
- Industrial Engineering (29)
- Mechanical Engineering (25)
- Other Operations Research, Systems Engineering and Industrial Engineering (24)
- Systems Engineering (19)
-
- Manufacturing (12)
- Electrical and Computer Engineering (9)
- Computer Engineering (7)
- Other Mechanical Engineering (7)
- Applied Mechanics (6)
- Civil and Environmental Engineering (6)
- Heat Transfer, Combustion (6)
- Arts and Humanities (5)
- Electrical and Electronics (5)
- Operational Research (5)
- Aerospace Engineering (4)
- Architecture (4)
- Computer-Aided Engineering and Design (4)
- Construction Engineering and Management (4)
- Education (4)
- Electro-Mechanical Systems (4)
- Materials Science and Engineering (4)
- Risk Analysis (4)
- Social and Behavioral Sciences (4)
- Acoustics, Dynamics, and Controls (3)
- Biomedical Engineering and Bioengineering (3)
- Business (3)
- Construction Engineering (3)
- Keyword
-
- Performance Based Design (99)
- Fire Dynamics Simulator (FDS) (78)
- RSET (76)
- ASET (74)
- Life Safety Code (64)
-
- Performance-Based Design (29)
- Fire Dynamics Simulator (21)
- Life Safety (21)
- Pathfinder (20)
- Available Safe Egress Time (ASET) (18)
- Prescriptive Analysis (18)
- Egress (17)
- Required Safe Egress Time (RSET) (17)
- Fire Protection (14)
- Fire Alarm (12)
- Fire Dynamic Simulator (FDS) (12)
- Fire Modeling (11)
- Smoke Control (11)
- FDS (10)
- Fire Protection Engineering (10)
- Prescriptive Design (10)
- Building Code (9)
- Design (9)
- Fire Suppression (8)
- Fire and Life Safety Analysis (8)
- Performance Based Analysis (8)
- Prescriptive Based Design (8)
- Building Fire Protection (7)
- Design Fire (7)
- Life Safety Analysis (7)
- Publication Year
- Publication
-
- Fire Protection Engineering: Culminating Experience Project Reports (194)
- Industrial and Manufacturing Engineering (36)
- Master's Theses (18)
- Mechanical Engineering (12)
- Computer Science and Software Engineering (9)
-
- Biomedical Engineering (8)
- Liberal Arts and Engineering Studies (6)
- BioResource and Agricultural Engineering (5)
- General Engineering (4)
- Architectural Engineering (3)
- Computer Engineering (3)
- College of Engineering Summer Undergraduate Research Program (2)
- Construction Management (2)
- Industrial Technology and Packaging (2)
- Materials Engineering (2)
- STAR Program Research Presentations (2)
- Chemistry and Biochemistry (1)
- Electrical Engineering (1)
- Publication Type
Articles 211 - 240 of 310
Full-Text Articles in Other Engineering
Westside Christian High School, Michael Stewart
Westside Christian High School, Michael Stewart
Fire Protection Engineering: Culminating Experience Project Reports
The building I have chosen to use as the model for exemplifying the components of a wet fire suppression system is Westside Christian High School (WCHS). This building completed construction in January of 2014 and is located at: 8200 SW Pfaffle Street Tigard, Oregon 97223. The existing structure was previously owned and occupied by City Bible Church who will now lease space from the High school during and after construction. The renovations include the addition of space for music, art classes, fitness center, gym, science labs, and others. The renovations will also be widening existing rooms and hallways. The core …
Fire Protection Analysis Robert And Margrit Modavi Center For The Performing Arts- Uc Davis, Jeffrey Paterson
Fire Protection Analysis Robert And Margrit Modavi Center For The Performing Arts- Uc Davis, Jeffrey Paterson
Fire Protection Engineering: Culminating Experience Project Reports
This document is the report of the culminating experience as part of the master’s program in fire protection engineering at the California Polytechnic State University, San Luis Obispo. This report contains a life safety analysis of the fire protection systems of a chosen project building. The building examined is the Robert and Margrit Mondavi Center for the Performing Arts, located on the University of California Davis campus. The building was constructed in 2002 where the first performance occurred in October 2002. A large portion of the report applies prescriptive code requirements to evaluate compliance with current codes and standards. The …
Fire Analysis Of The Walter F. Dexter Building- Cal Poly, San Luis Obispo, Jeff Jenkins
Fire Analysis Of The Walter F. Dexter Building- Cal Poly, San Luis Obispo, Jeff Jenkins
Fire Protection Engineering: Culminating Experience Project Reports
The purpose of this report is to provide a fire analysis of the Walter F. Dexter Building on the California Polytechnic State University, San Luis Obispo Campus. The report will detail egress analysis, notification systems, and building construction in a prescriptive approach. The report will also include a performance based analysis of the building with a designed fire scenario. This performance based analysis will show that in one of the most likely fire scenarios for the building, there is still ample time for the occupants to escape safely.
Hotel- Georgia, Rock Toler
Hotel- Georgia, Rock Toler
Fire Protection Engineering: Culminating Experience Project Reports
The State of Georgia modifies the International Building Code through State amendments, to require a fire resistance rating between residential occupancies and all other occupancies. This fire and life safety analysis report will substantiate the necessity for the barrier in a mixed-use hotel occupancy. The first-half of the report addresses the prescriptive-based code requirements, reporting a compliant design was presented. Then the performance portions primary objective was established, maintain a tenable environment for egressing guest room occupants. Three conditions were evaluated to define a tenable environment, carbon monoxide levels, temperature, and visibility limits. Selecting the location of the fire required …
Fire And Life Safety Analysis Of The Grant M. Brown Engineering Building- Cal Poly, Daniel Gregory Blanchat
Fire And Life Safety Analysis Of The Grant M. Brown Engineering Building- Cal Poly, Daniel Gregory Blanchat
Fire Protection Engineering: Culminating Experience Project Reports
This fire and life safety analysis was performed on the Grant M. Brown Engineering Building in order to determine if the building meets the life safety goals set forth by a prescriptive and performance based analysis. This building was built to a strict set of codes and standards. For the prescriptive analysis the buildings egress design, fire detection and alarm systems, fire sprinkler system, occupancy classification, construction type, and structural fire protection are evaluated in terms of the life safety of the occupants. In the performance based design analysis four computer based programs were used to model egress and fire …
Comprehensive Fire And Life Safety Analysis- Moa Public Works Building- Anchorage, Alaska, Andrew J. Bigalke
Comprehensive Fire And Life Safety Analysis- Moa Public Works Building- Anchorage, Alaska, Andrew J. Bigalke
Fire Protection Engineering: Culminating Experience Project Reports
This report is a Comprehensive Fire and Life Safety Analysis addressing both prescriptive and performance based engineering analysis of the MOA Public Works building located in the Municipality of Anchorage, Alaska. The Public Works building was originally built in 1997 under the code requirements of the Uniform Building Code, as a Type II-N building. An addition was constructed in 2002 using the International Building Code (IBC), 2000 Edition. A prescriptive analysis is performed using the requisite building code and standards currently adopted by the State of Alaska, and by the Municipality of Anchorage. The currently adopted building codes and standards …
Fire Protection And Life Safety Evaluation- Hinesville Cboc Va Clinic, Jeff Dew
Fire Protection And Life Safety Evaluation- Hinesville Cboc Va Clinic, Jeff Dew
Fire Protection Engineering: Culminating Experience Project Reports
The Hinesville MOB will be analyzed throughout the course of this report to determine if it meets the prescriptive-based requirements set forth by local and national regulating bodies. Further, a performance-based approach will be taken to assess the buildings ability to sustain life while a safe and timely evacuation occurs. It will be determined that the Hinesville MOB does comply with all regulations set forth for fire and life safety. In some cases its construction and systems may exceed the required minimum standards. It will contain 100% coverage with an automatic sprinkler system, be equipped with adequate emergency notification system, …
Fire And Life Safety Analysis- Cal Poly Recreation Center, Connor Mcgill
Fire And Life Safety Analysis- Cal Poly Recreation Center, Connor Mcgill
Fire Protection Engineering: Culminating Experience Project Reports
The purpose of this fire and life safety analysis is to determine whether Cal Poly’s Recreation Center meets fire safety goals. The primary fire safety goal is to provide building occupants with an environment that is tenable and allows for safe egress in the event of a fire, and reduce the likelihood of any catastrophic fire event. This goal can be achieved by protecting the occupants not intimate with the initial fire development and improving survivability of those occupants intimate with the initial fire development, NFPA 101, 2012. A prescriptive-based design approach and a performance-based design approach are used to …
Horned Lark Management For The Protection Of Lettuce Sprouts, Taylor Wetzel, Eduardo Morales, Kyle Suguitan
Horned Lark Management For The Protection Of Lettuce Sprouts, Taylor Wetzel, Eduardo Morales, Kyle Suguitan
Mechanical Engineering
The following document is the Final Project Report. Following the Critical Design Report, the top idea was taken and modified once again to suit the needs of the sponsor. Details regarding the changes are outlined throughout Chapter 3.
The provided background section explains why there is a need for a new device at Tanimura and Antle that will suit the customer's needs better than current methods and existing products. The top ideas picked for the Conceptual Design Review are the presented to reiterate the problems that were depicted in them and why they were not selected as part of the …
Design Analysis Of An Air Force Fuel Cell Maintenance Hangar, Andrew Carmean
Design Analysis Of An Air Force Fuel Cell Maintenance Hangar, Andrew Carmean
Fire Protection Engineering: Culminating Experience Project Reports
A Fuel Cell Maintenance Hangar (FCMH) was constructed in 2013 based on a 2012 design; Figure 1.1.1 is a rendering shown below. This report evaluates the design for life safety, and property protection systems. The facility was designed based on Air Force standard prescriptive methods; the resultant design is compared to minimum prescriptive methods and to as-built drawings. In addition, the property protection design criteria were evaluated by simulating the maximum expected design fire in a hangar bay 1 using Fire Dynamics Simulator (FDS). Section 1 consists of a general overview of the FCMH including descriptions of the facility and …
Fire Protection And Life Safety Analysis- Dell Medical School Academic Building, David Gramlich
Fire Protection And Life Safety Analysis- Dell Medical School Academic Building, David Gramlich
Fire Protection Engineering: Culminating Experience Project Reports
This report is on the Dell Medical School Academic Building located in Austin, Texas. The life safety and prescriptive based code requirements are summarized within this report. It also includes conceptual fire protection and fire alarm system design. This report mentions University of Texas System Owner’s Design Guidelines that exceed the required code requirements. This report was developed when the building was in the Design Development stage. Since, code deficiencies have been addressed, and changes have been made to the building during the remainder of the design process, this report does not reflect the actual construction or protection strategies used …
Construction Warehouse, Ben Johnson
Construction Warehouse, Ben Johnson
Fire Protection Engineering: Culminating Experience Project Reports
The purpose of this report is to provide a comprehensive evaluation of the fire protection and life safety design of a warehouse building that serves a large construction project. The results and conclusions from this evaluation are documented herein and supported by analysis when necessary. The gross floor area per story of the construction warehouse is 39,000 ft2. This building is used as a warehousing facility in support of a large construction project. Rack storage of Group A plastics is permitted in this facility to a height of 20 ft. beneath a 24 ft. ceiling on the main floor. Shelf …
Fire And Life Safety Analysis- Af Child Development Center, Judy Biddle
Fire And Life Safety Analysis- Af Child Development Center, Judy Biddle
Fire Protection Engineering: Culminating Experience Project Reports
The purpose of this fire and life safety report is to determine whether The Air Force (AF) Child Development Center (CDC) Standard Design meets fire safety goals based on an increased child-to staff ratio and provide a prescriptive based analysis of the of the existing codes that the building was constructed under. The primary fire safety goal is to provide building occupants with an environment that is reasonably safe from fire. A prescriptive-based design approach and a performance-based design approach are used to evaluate building safety in regards to occupant protection, structural integrity, and systems effectiveness. The prescriptive-based approach is …
Fully Accessible Raised Garden Beds, Ethan Lockwood
Fully Accessible Raised Garden Beds, Ethan Lockwood
Liberal Arts and Engineering Studies
The Ranch, a local nonprofit that is a community gathering location for recreation and education, providing outdoor employment opportunities for area residents with developmental disabilities and a unique experience for volunteers and visitors., was lacking a farming and gardening environment that was fully accessible for all people including those in wheelchairs. This project provided substantial background research for the mission of The Ranch, demonstrated sustainable design, secured material donations, CAD modeled raised beds, and provided meaningful employment during the construction of the raised beds. The project resulted in three different raised bed designs that are all in use by The …
Orangeburg Assembly Hall Of Jehovah's Witnesses- Fire Protection And Life Safety Design Analysis, Justin B. Biller
Orangeburg Assembly Hall Of Jehovah's Witnesses- Fire Protection And Life Safety Design Analysis, Justin B. Biller
Fire Protection Engineering: Culminating Experience Project Reports
In partial fulfillment of the requirements for the Degree of Masters of Science in Fire Protection Engineering, a prescriptive and performance-based engineering analysis was performed on the Orangeburg Assembly Hall of Jehovah’s Witnesses. The building was recently constructed and completed in 2013 in Orangeburg, South Carolina to serve as a center for education of Jehovah’s Witnesses on Biblical principles for daily life. More than 300 congregations throughout Georgia and the Carolinas will use the Assembly Hall for their semi-annual assemblies and conventions, with an estimated annual attendance of 190,000 per year. Prescriptive analyses were conducted based primarily upon the provisions …
Fuzz Pedal Design Project, Kyle Schaefer
Fuzz Pedal Design Project, Kyle Schaefer
Biomedical Engineering
The purpose of this project was to design and build a high quality, yet affordable, analog “fuzz” guitar pedal kit to be sold to other members of Cal Poly’s Audio Engineering Society. The Audio Engineering Society (AES) has hosted pedal-building projects in the past, but my project partner Michael Twardochleb first had the idea to build an original kit to be officially affiliated with the club. Michael had built other pedals of his own in the past, making him an excellent partner to have for this project. Our design was based on the classic Vox Tonebender’s circuit, which was in …
Fire Protection Life Safety Analysis- Bachelor Enlisted Quarters, Kyle C. Leadon
Fire Protection Life Safety Analysis- Bachelor Enlisted Quarters, Kyle C. Leadon
Fire Protection Engineering: Culminating Experience Project Reports
This Bachelor Enlisted Quarters (BEQ) shall be constructed, arranged, equipped, maintained, and operated in accordance with this report and applicable criteria to ensure a minimum level of life safety and property protection is provided from actual and potential fire hazards. The goal is to ensure the occupants are provided with an environment that is reasonably safe from fire. We accomplish this goal by protecting occupants not intimate with the initial fire development, and by improving the survivability of occupants intimate with the initial fire development. The protection described in this report takes on many forms, from active protection, such as …
Fire Protection Analysis Of Campus Building, Mackenzie Hill
Fire Protection Analysis Of Campus Building, Mackenzie Hill
Fire Protection Engineering: Culminating Experience Project Reports
A prescriptive and performance based analysis has been conducted on a College Campus Building in Southern California. This building is still in the approvals process and has been designed to meet the design standards in the 2010 California Building Code (CBC) and relevant NFPA codes. The building is proposed to be the center of operations as well as having administration facilities for the College. It will house an administrative office, production and support facilities. The project is three stories and includes a balcony that does not qualify as a story. The top floor is greater than 30 feet from grade …
Fire And Life Safety Analysis- Center For Science And Mathematics Building #52, Laura Radle
Fire And Life Safety Analysis- Center For Science And Mathematics Building #52, Laura Radle
Fire Protection Engineering: Culminating Experience Project Reports
The purpose of this fire and life safety analysis is to determine whether Cal Poly’s Center for Science and Mathematics (CSM) meets fire safety goals. The primary fire safety goal is to provide building occupants with an environment that is reasonably safe from fire. This goal can be achieved by protecting the occupants not intimate with the initial fire development and improving survivability of those occupants intimate with the initial fire development, (NFPA 101, 2006). A prescriptive-based design approach and a performance-based design approach are used to evaluate building safety. The prescriptive-based approach is used to evaluate the building’s structural …
Mixed‐Use Commercial And Residential Podium Building, Gene Voloshenko
Mixed‐Use Commercial And Residential Podium Building, Gene Voloshenko
Fire Protection Engineering: Culminating Experience Project Reports
This report provides a summary of the principal fire protection and life safety features for a mixed use commercial and residential Podium Building for compliance with the 2000 International Building Code (IBC) and the 2003 NFPA 101 “Life Safety Code”. IBC permits compliance with the prescriptive Code requirements using Alternative Solutions that will achieve at least the minimum level of performance required by the IBC as defined by the objectives and functional statements and as described in the NFPA 101 Chapter 5. Alternative solutions for this project were modeled using the Fire Dynamics Simulator (FDS). One of the primary recommendations …
Fire Protection Analysis Of The Bonderson Engineering Projects Center, John Cote
Fire Protection Analysis Of The Bonderson Engineering Projects Center, John Cote
Fire Protection Engineering: Culminating Experience Project Reports
A Fire and Life Safety Analysis of the Bonderson Engineering Projects Center (BEPC) located on the Cal Poly campus is performed. Prescriptive and Performance Based approaches are used to evaluate the BEPC for compliance with the current fire and building code requirements. The fire protection systems and features of the BEPC analyzed include the following: Egress Systems, Fire Detection, Alarm, and Communications Systems, Fire Suppression Systems, and Structural Fire Protection Systems. Prescriptive analyses are performed to determine if the as-built design meets the requirements of the code. Performance-Based analyses are performed to provide insight to the prescriptive design utilized in …
Telecommunications Network Switching Facility, Eric Kumar
Telecommunications Network Switching Facility, Eric Kumar
Fire Protection Engineering: Culminating Experience Project Reports
This report is on a mission critical telecommunications network switching facility located in Southern Mississippi. The life safety and property preservation measures are summarized in this report. The prescriptive design approaches for various fire and life safety systems in telecommunications facilities were evaluated against the performance based approaches studied in the Cal Poly Fire Protection Engineering curriculum. Majority of the prescriptive approaches are in accordance with the performance based solutions, however the smoke management system’s performance and prescriptive design yields a significant discrepancy. For the smoke management system, a difference in the flow rates is observed between the exhaust and …
Fire And Life Safety Evaluation Of The Providence Pavilion, Oscar J. Zuniga
Fire And Life Safety Evaluation Of The Providence Pavilion, Oscar J. Zuniga
Fire Protection Engineering: Culminating Experience Project Reports
The fire and life safety systems of the Providence Pavilion, a four-story addition to the Providence Medford Medical Center in Medford, Oregon, are examined for compliance with applicable design and construction codes and standards and are found to comply with codes and conform to standards. The prescriptive requirements for occupancy classification, construction type, structural fire protection, egress systems, fire alarms, and fire protection are reviewed. Three different fire scenarios are developed and are then employed to study the fire and life safety systems’ performance using fire and egress modeling tools and simulations. Using this performance-based approach, the fire and life …
Culminating Project- U.S. Federal Courthouse, Joshua W. Elvove
Culminating Project- U.S. Federal Courthouse, Joshua W. Elvove
Fire Protection Engineering: Culminating Experience Project Reports
The purpose of this report is to select and evaluate a building for compliance with prescriptive and performance based requirements, that apply the concepts learned from previous courses taken as part of the master’s fire protection engineering degree curriculum at Cal Poly, San Luis Obisbo. The report discusses applicable code requirements for building construction, egress, fire alarm initiation and notification, and fire suppression and evaluates the building’s performance, including occupant movement, when subjected to two assumed fires. Fire Dynamics Simulator (FDS) was used to generate data used during the performance analysis. The performance analysis reveals that meeting prescriptive requirements doesn’t …
Fire Protection Analysis Of A Fresno Elementary School, Garen Lencioni
Fire Protection Analysis Of A Fresno Elementary School, Garen Lencioni
Fire Protection Engineering: Culminating Experience Project Reports
This report details the fire and life safety analysis of a Fresno Elementary School. Both prescriptive and performance based analysis were used to determine compliance with the building codes and fire codes which the building was constructed under. The prescriptive analyses included evaluation of the egress system, structural fire protection requirements, fire detection and alarm system and fire suppression systems. The prescriptive analyses were done to show the code requirements and how the building complies with them. The performance analyses were done to analyze the performance of the building in the event of a fire scenario. Three fire scenarios were …
Barbeque Grill Temperature Distribution Design Improvement, Peter Gobell, Connor Mcgill, Thomas Willson
Barbeque Grill Temperature Distribution Design Improvement, Peter Gobell, Connor Mcgill, Thomas Willson
Mechanical Engineering
Team License to Grill set out to asses Bull Outdoor Products, Inc.’s barbeques and quantify the apparent uneven temperature distribution or “hot spots” and “cold spots” across the grill. This testing was accomplished with the design and fabrication of a test fixture allowing for accurate and repeatable temperature collection across the barbeque. With results that matched the sponsor’s claims of hot and cold spots, an engineering model was made using heat transfer and thermodynamic equations. Once the model somewhat resembled the experimental data, it was used to suggest different modifications that would allow for better temperature distribution. It was discovered …
Comparing Class A Compressed Air Foam Systems (Cafs) Against Plain Water Suppression In Live Fire Gas Cooling Experiments For Interior Structural Firefighting, Sean Carter Mitchell
Comparing Class A Compressed Air Foam Systems (Cafs) Against Plain Water Suppression In Live Fire Gas Cooling Experiments For Interior Structural Firefighting, Sean Carter Mitchell
Master's Theses
Wildland fire services have successfully integrated compressed air foam systems (CAFS) into their fire suppression arsenal over the last few decades to effectively increase the firefighting ability of water. Many urban fire departments have done the same, but far more still rely on plain water to extinguish Class A fires. Many claims have been made about the advantages and disadvantages of firefighting foams, but only limited research has been conducted on the subject to date. Fire departments need more information, beyond that provided by foam suppliers and CAFS equipment manufacturers, to make an independent decision on whether or not to …
Evaluation Of Thermophile Algae In Horizontal Photo-Bioreactor, Olivier Schmied
Evaluation Of Thermophile Algae In Horizontal Photo-Bioreactor, Olivier Schmied
BioResource and Agricultural Engineering
No abstract provided.
Dedion Axle Senior Project, Nick Schraan, Mark Shushnar, William Swenson, Ramy Tall
Dedion Axle Senior Project, Nick Schraan, Mark Shushnar, William Swenson, Ramy Tall
Mechanical Engineering
The sponsor, EV Grid Inc. is a company looking to the future with the development of a vehicle to grid infrastructure. The vehicle in development is a Ford E-250 Van which had been converted to electric drive with a front motor, rear drive layout. The sponsor wanted to move the electric motor to the rear and develop an axle to support this change. By eliminating the driveshaft, a more efficient use of battery space could be utilized. The goal of this project is to design and fabricate a prototype deDion rear axle which incorporates a system of drive components that …
Fire Protection Analysis Of The ‘Center For The Arts’ Building', Steven W. Carman
Fire Protection Analysis Of The ‘Center For The Arts’ Building', Steven W. Carman
Fire Protection Engineering: Culminating Experience Project Reports
In partial fulfillment of the requirements for the Degree of Masters of Science in Fire Protection Engineering, a prescriptive and performance-based analysis was performed on a building housing the Center for the Arts. The building was constructed in 1947 in California as an automobile dealership and repair shop under the provisions of the then-controlling Uniform Building Code. It subsequently underwent several occupancy changes and has since served as a beauty school, gymnastics center, and currently as a performing and visual arts center. Prescriptive analyses were conducted based primarily upon the provisions of the 2010 California Building and Fire Codes, and …