Tnt Equivalence Of Binary Energetics, Gracie Mae James Apr 2024

Tnt Equivalence Of Binary Energetics, Gracie Mae James

Undergraduate Research Conference at Missouri S&T

TNT equivalency is a standard used to measure and quantify the effects of energetic materials. Using these equivalencies, the safety factors for minimum distances and storage of explosives are determined. Having a known TNT equivalence of energetic materials also helps estimate potential blast damage and risks for individuals. The TNT equivalencies for numerous energetic materials, such as binaries, have no published values, but are regularly used in industry, military, and research testing. To determine TNT equivalence, three tests will be performed: 1) a plate dent test, 2) air blast tests to measure air overpressure and calculate impulse, and 3) velocity …


Aerial Radiation Detection Identification And Measurement System Detector Material Comparison Study, Benjamin C. Troxell, Kacey D. Mcgee, Christina L. Dugan Apr 2022

Aerial Radiation Detection Identification And Measurement System Detector Material Comparison Study, Benjamin C. Troxell, Kacey D. Mcgee, Christina L. Dugan

Faculty Publications

The 20th Chemical Biological Radiological Nuclear and Explosives Command (CBRNE) currently utilizes an airborne sodium iodide gamma and beta detection system to map radiation fields over large areas of interest. The 20th CBRNE explored emergent detector technologies utilizing two detection materials; thallium-activated cesium iodide and high purity germanium (HPGe). These detectors were simulated at various altitudes and compared to background measurements. The sodium iodide detector failed to provide isotopic discrimination at distance. The thallium-activated cesium iodide CsI(Tl) detector provided sufficient absolute efficiency and energy resolution to identify isotopics at distance. The HPGe detector provided the best energy resolution. However, current …


Thin Safety Margin: The Sefor Super-Prompt-Critical Transient Experiments, Ozark Mountains, Arkansas 1970–1971, Jerry Havens, Collis Geren Oct 2021

Thin Safety Margin: The Sefor Super-Prompt-Critical Transient Experiments, Ozark Mountains, Arkansas 1970–1971, Jerry Havens, Collis Geren

Arkansas Scholarly Editions

Thin Safety Margin charts the history of SEFOR, a twenty-megawatt reactor that operated for three years in the rural Ozark Mountains of Arkansas as part of an internationally sponsored program designed to demonstrate the Doppler effect in plutonium-oxide-fueled fast reactors. Authors Jerry Havens and Collis Geren draw upon this history to assess the accidental explosion risk inherent in using fast reactors to reduce the energy industry’s carbon dioxide emissions.

If a sufficiently powerful fast-neutron explosion were to cause the containment of a reactor such as SEFOR’s to fail, the reactor’s radiotoxic plutonium fuel could vaporize and escape into the surrounding …